Presentation is loading. Please wait.

Presentation is loading. Please wait.

LHQ01 IL Curing Miao Yu 01/31/2013. LHQ IL Packing for Curing 2.

Similar presentations


Presentation on theme: "LHQ01 IL Curing Miao Yu 01/31/2013. LHQ IL Packing for Curing 2."— Presentation transcript:

1 LHQ01 IL Curing Miao Yu 01/31/2013

2 LHQ IL Packing for Curing 2

3 3

4 4

5 Shrink wrap after painting Matrix 5

6 Curing Spacer Install 6

7 Coil Rotation 7

8 Coil in the curing mold 8

9 Curing Press Mandrel pressure (pump psi) Platen pressure (pump psi) Gap (mm) 15007000.076~0.102 275010000~0.038 3100015200 9 Based on the simulation, 1500 pump psi should give ~1.5 MPa to the mandrel 2280 pump psi should give ~20 MPa to the coil azimuthally

10 After curing 10

11 Coil Measurement 11 A (mm)B (mm)C (mm)D (mm)E (mm) Nominal412.63422.40451.67480.02573.80 Before curing412.67421.36450.83486.39580.19 After curing412.6421.66450.70480.85574.80

12 12 A (mm)B (mm)C (mm)D (mm)E (mm)F (mm) Nominal382.64390.69404.64407.32421.67448.20 Before curing383.57388.55404.62407.08421.65452.49 After curing382.88391.52405.96408.1422.59448.33

13 Pole Gap 13 G1 (mm) G2 (mm) G3 (mm) G4 (mm) G5 (mm) G6 (mm) G7 (mm) G8 (mm) Total (mm) Before winding1.524 12.192 Before curing1.431.411.441.471.5 1.451.6911.891 After curing1.261.611.81.841.731.841.671.6513.4 LE RE Before curing, total gap size decreases by 0.301 mm from 12.192 mm After curing, total gap size increases by 1.208 mm from 12.192 mm Need to find out LQ coil gap size?


Download ppt "LHQ01 IL Curing Miao Yu 01/31/2013. LHQ IL Packing for Curing 2."

Similar presentations


Ads by Google