CCNA1 v3 Module 9 v3 A+ Type 1 JEOPARDY K. Martin.

Similar presentations


Presentation on theme: "CCNA1 v3 Module 9 v3 A+ Type 1 JEOPARDY K. Martin."— Presentation transcript:

1

2 CCNA1 v3 Module 9 v3 A+ Type 1 JEOPARDY K. Martin

3 CCNA1 v3 Module 9 RouterModesWANEncapsulationWANServicesRouterBasicsRouterCommands 100 200 300 400 500RouterModesWANEncapsulationWANServicesRouterBasicsRouterCommands 100 200 300 400 500 Type 1 Type 1 a Type 1 b Type 1 Type 1 c Type 1 Type 1 d Type 1 e Type 1 Type 1 f 100 200 300 400 500 100 200 300 400 500 ► ► ► F i n a l J e o p a r d y ◄ ◄ ◄

4 CCNA1 v3 Module 9 Question If EPA regulations change after a technician become certified, he must: Type 1 a 100 A: What is comply with any future changes in the law? 100 200 300 400 500 CCNA1 v3 Module 9

5 Question A: What is When the compressor does not run? Using the system-dependent (passive) recovery process, when should you access both high and low sides of the system for recovery? CCNA1 v3 Module 9 Type 1 a 200 100 200 300 400 500

6 CCNA1 v3 Module 9 Question 100 200 300 400 500 A: What is Nov. 15, 1993? Small appliance recovery equipment manufactured after _____________ must be EPA certified. CCNA1 v3 Module 9 Type 1 a 300

7 CCNA1 v3 Module 9 Question 100 200 300 400 500 A: What is the pressure/temp chart only works if the pressure and temp are known and stable? When checking for non-condensables in a recovery cylinder, you should allow temp of cylinder to stabilize to room temp because: CCNA1 v3 Module 9 Type 1 a 400

8 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is non-pressurized container? A standard vacuum pump designed for evacuation and dehydration can be used as a recovery device only on a: Type 1 a 500

9 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is the type of refrigerant in the system? Before beginning refrigerant recovery, it is always necessary to know: Type 1 b 100 200 300 400 500

10 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is a non pressurized container? The system-dependent (passive) recovery process for small appliance captures refrigerant into a: Type 1 b 200

11 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is a pressurized recovery tank? The self-contained (active) recovery process for small appliance captures refrigerant into a: Type 1 b 300

12 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is 80% on both? Small appliance recovery equipment made BEFORE Nov. 15 1993 must recover _____% of refrigerant on operating and _____% on non-operating compressors. Type 1 b 400

13 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is 80% on non-operating and 90% on operating compressors? Small appliance recovery equipment made AFTER Nov. 15 1993 must recover _____% of refrigerant on operating and ______ % on non-operating compressors. Type 1 b 500

14 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is heat the compressor and strike it with a rubber mallet? When recovering refrigerant into a non- pressurized container and compressor is not working, you need to: Type 1 c 100

15 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is recovered if it’s a regulated refrigerant? When filling a graduated charging cylinder, refrigerant vented off top of cylinder must be: Type 1 c 200

16 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is for refrigerant leaks and oil level? What recovery equipment recovery practices should be performed on a regular basis? Type 1 c 300

17 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is service valve? All appliances must have a __________ __________ valve for recovering and charging refrigerants. Type 1 c 400

18 CCNA1 v3 Module 9 4 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is check vacuum pump for leaks, check recovery device for leaks, check amperage draw of recovery device Recovery equipment fittings must be equipped with ____ ______ fittings, which can be manually or automatically closed. Type 1 c 500

19 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is pressure / temp chart ? One way to identify refrigerant is by using the : Type 1 d 100

20 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is self-contained or system-dependent? For small appliances, you may use either a _____-__________ or a ______-_________ recovery system. Type 1 d 200

21 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is tank inlet valve? Before opening a self-contained recovery device, make sure the _________is open. Type 1 d 300

22 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is excessive air or noncondensables? Before opening a self-contained recovery device, make sure the tank does not contain _________ or ___________. Type 1 d 400

23 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is a checking pressure inside the tank? Checking for air and noncondensables can be done by: Type 1 d 500

24 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is high side of the system? When using a system-dependant recovery process with an operating compressor, run the compressor and recover from the: Type 1 e 100

25 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is access both high and low sides of the system? When using a system-dependant recovery process with an non-operating compressor, you may need to: Type 1 e 200

26 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 What is defrost heater? Operating the _____________ will help to vaporize any trapped liquid refrigerant and will speed the recovery process. Type 1 e 300

27 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is ammonia, hydrogen, water, methyl formate, methyl chloride, and sulfur dioxide? Which refrigerants are not covered by EPA? Type 1 e 400

28 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is a straight piece of tubing with a piercing valve? What does a service aperture on a small appliance typically look like? Type 1 e 500

29 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What are not opening the tank inlet valve or having excess air? What are 2 things that can cause high discharge pressure: Type 1 f 100

30 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is room temp? What temp must a cylinder be at to check for excess air? Type 1 f 200

31 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is can be manually or automatically closed when disconnecting hoses to prevent refrigeration loss? Low loss fittings are required on recovery equipment. What do they do? Type 1 f 300

32 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What is self-contained or system dependant? These 2 types of recovery devices can be used on small appliances: Type 1 f 400

33 CCNA1 v3 Module 9 Question 100 200 300 400 500 CCNA1 v3 Module 9 A: What are Those used in campers, recreational vehicles, or in systems built before 1950? Which refrigerants are not covered in EPA 608? Type 1 f 500

34 CCNA1 v3 Module 9 Question A: What is 132 Mb using a 32 bit bus and 264 Mb using a 64 bit bus? Data transfer performance using a PCI bus. Final Jeopardy CCNA1 v3 Module 9 100 200 300 400 500