Isocyanate Comparative Sampling Method Ann Anderson – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Arlington Assembly Plant Larry Hunt.

Similar presentations


Presentation on theme: "Isocyanate Comparative Sampling Method Ann Anderson – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Arlington Assembly Plant Larry Hunt."— Presentation transcript:

1

2 Isocyanate Comparative Sampling Method Ann Anderson – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Arlington Assembly Plant Larry Hunt – GM Regional IH

3 DuPont 2K Clear Coat Paint part A (resin, solvent, additives) + part B (HDI monomer, IPDI monomer, HDI polymer, IPDI polymer, solvent, adds.) HDI polymer, IPDI polymer, solvent, adds.)______________________________ = 2 Part Polyurethane (A+B)

4 Common Sample Methods for Isocyanate  Impinger  Glass Fiber Filter Cassette  Asset EZ4

5 Midget Impingers

6 Isocyanate Sample Method Pros and Cons  Impinger –Inconvenient for Personal samples. –Contains liquid solution that can leak –Glass impinge may break –Least desired sample collection for employee

7 Filter Cassette & Parts

8 Isocyanate Sample Method Pros and Cons  Filter Cassettes –Easy to use in the field –Short Shelf life –Filters place in desorption container –Storage and shipping with temperature control, on ice.

9 Asset EZ4 Dry Sampler

10 Isocyanate Sample Method Pros and Cons  Asset EZ4 Dry Sampler –Denuder selection collects the vapors phase –Filter collects the aerosol particulates –Low detection limits, high capacity –Forms Stable derivatives –Low flow rate challenge to maintain pre and post calibration –Shipping: no temperature control and longer shelf life.

11 Sample Train for Stand for Tests

12

13 Asset Tubes & Cassettes for Isocyanate Tests

14 Tool to Remove Cassette Top  Cassette Wrench

15 Preparation to Open Cassette to Remove Filter

16 Cassette Filter Pad Removal

17 Vile for Filter from Cassette

18 Samples Ready to Ship

19 Results for Comparison Sample General Area samples inside Booth B Vestibule - - approx. 5 ft. off floor, Not a work area B booth inside vestibule. Employees not in this area. Five feet off the floor on a stand RH00028 9 0.50 mg/m 3 Isophorone Diisocyanate (IPDI) (CAS# 4098- 71-9)< 0.84 ppb 5.0 ppb Methylene Bisphenyl Isocyanate (MDI) (CAS# 101-68-8)< 0.3 ppb 5.0 ppb Hexamethylene Diisocyanate (HDI) (CAS# 822-06-0)0.9 ppb 5.0 ppb RH00029 8 0.50 mg/m 3 Isophorone Diisocyanate (IPDI) (CAS# 4098- 71-9) < 0.1 ppb5.0 ppb Methylene Bisphenyl Isocyanate (MDI) (CAS# 101-68-8) < 0.09 ppb5.0 ppb Hexamethylene Diisocyanate (HDI) (CAS# 822-06-0) 0.94 ppb5.0 ppb General Area samples inside a Vestibule area - - approx. 5 ft off floor, Not a work area A booth inside vestibule area. Employees not in this area. Five feet off the floor on a stand RH00029 0 0.50 mg/m 3 Isophorone Diisocyanate (IPDI) (CAS# 4098- 71-9)< 0.84 ppb 5.0 ppb Methylene Bisphenyl Isocyanate (MDI) (CAS# 101-68-8)< 0.3 ppb 5.0 ppb Hexamethylene Diisocyanate (HDI) (CAS# 822-06-0)< 0.45 ppb 5.0 ppb RH00029 9 0.50 mg/m 3 Isophorone Diisocyanate (IPDI) (CAS# 4098- 71-9) < 0.13 ppb5.0 ppb Methylene Bisphenyl Isocyanate (MDI) (CAS# 101-68-8) < 0.12 ppb5.0 ppb Hexamethylene Diisocyanate (HDI) (CAS# 822-06-0) 0.36 ppb5.0 ppb

20 Wentzville Assembly Sample Method

21 Sample at Wentzville

22 Calibration Pocket Pump Wentzville

23 Data Calibration Pocket Pump SURVEY 259688 RLH000094 POCKET PUMP 32115 POST CAL 09-30-2015 ProductDEFENDER 510 Serial Number129638 SampleDryCal mL/min DryCal Avg. mL/min Time 1208.34208.3415:49:45 2208.33208.3415:49:54 3208.36208.3415:50:04 4208.31208.3415:50:13 5208.32208.3315:50:22 6208.40208.3415:50:32 7208.43208.3615:50:41 8208.35208.3615:50:51 9208.44208.3615:51:00 10208.41208.3715:51:10

24 Summary  Sampling with GFF Cassette –Temperature Control –No data on Total Isocyanate available  Sampling with Asset EZ4 –No temperature Requirements –Low Flow Rate challenge –Easy for Personal samples –Total Isocyanate data and detection level

25 Recommendation  Sample for isocyanate with the Asset method  Provide Pocket sample pumps for isocyanate testing.

26


Download ppt "Isocyanate Comparative Sampling Method Ann Anderson – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Rick Hurd – IH Tech/Ergo Arlington Assembly Plant Larry Hunt."