Green Power Tools: Assessment Tools to Support Green Remediation Goals April 5, 2011 www.brownfields2011.org.

Similar presentations


Presentation on theme: "Green Power Tools: Assessment Tools to Support Green Remediation Goals April 5, 2011 www.brownfields2011.org."— Presentation transcript:

1 Green Power Tools: Assessment Tools to Support Green Remediation Goals April 5, 2011 www.brownfields2011.org

2 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA1 Agenda Presenters:  Susan Flakus, Innovative Technical Solutions, Inc.  Steve Dyment, USEPA, Office of Superfund Remediation and Technical Innovation (OSRTI)  Joe Siperstein, OhioLumex Company  Yi Wang, ZymaX Forensics/DPRA  David Sullivan, TRC www.brownfields2011.org

3 Lumex Field Applications: Mercury Mine Watershed RI EPA Superfund Site April 5, 2011 Susan Flakus Senior Project Manager sflakus@itsi.com www.brownfields2011.org

4 www.brownfieldstsc.org Mercury Mine Site Watershed RI Sediment and soil samples collected from transects along 6 miles of streambed and floodplain and reservoir with deep sediments. Field laboratory with OhioLumex RA-915 with RP-91C attachment for soils testing. 247 samples split for offsite laboratory analysis by EPA CLP lab for total metals. Mercury results used for dynamic field decisions for additional sample locations. APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA3 www.brownfields2011.org

5 www.brownfieldstsc.org Lumex Soil Test Data Quality Instrument detection limit (0.5 ppb) lower than action level; precision and accuracy goals met. Offsite laboratory analysis by EPA method 7473 to confirm total metal result (at least 10%). Field chemist trained; pass proficiency test. PE samples provided, confirmed by EPA QA. Multi-point calibration curve performed daily, traceable to National Institute of Standards and Technology (NIST) standards. Duplicate samples tested (at least 10%). APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA4 www.brownfields2011.org

6 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA5 www.brownfields2011.org Lumex Soil Field Test Operations.

7 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA6 www.brownfields2011.org Lumex Soil Sample Preparation

8 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA7 www.brownfields2011.org Lumex Soil Testing

9 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA8 www.brownfields2011.org Weighing soil sample.

10 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA9 www.brownfields2011.org Field Chemist performs QC check.

11 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA10 www.brownfields2011.org Lumex Soil Sample Result.

12 www.brownfieldstsc.org APRIL 3-5, 2011 | PHILADELPHIA, PENNSYLVANIA11 www.brownfields2011.org Comparison of Lumex and CLP Lab Mercury Results EPA Mercury Mines Superfund Site Remedial Investigation, Central Coast, California

13 On-Site Mercury Soil Testing Joseph Siperstein, Ohio Lumex Brownfields 2011 Ohio Lumex Company

14 www.brownfieldstsc.org MERCURY DETERMINATION mercury content in ambient air, detecting mercury spills mercury determination in aqueous samples, EPA method 1631 direct (no digestion) analysis of soil,complex matrixes, EPA method 7473 mercury monitoring for indoor air (‘Instant’ NIOSH 6009 results) mercury determination in natural gas or industrial emmisions monitoring FIELD or LABORATORY APPLICATIONS with RA-915 + Air – 2 ng/m 3 range -- 0.000005 - 0.1mg/m 3 liquids – 0.5 ng/l solids – 0.5 µg/kg background correction Zeeman effect with HF polarization modulation size and weight 460x210x110 mm; 7.5 kg power supply 220/110 Vac, 50/60 Hz; 10/14 Vdc RP91 RP91C RA 915 www.brownfields2011.org

15 www.brownfieldstsc.org MERCURY DETERMINATION RA 915 Pyro with RA-915 + Reference material Мass, mgMeasured value, ppb Certificate value, ppb Deviation, % NIST 1630a (Coal) 60 140 99 92 105±23-9 DOLT-2 (Fish liver) 50 110 1860 2070 2140±240-8 DORM-1 (Fish) 50 100 860 780 798±74+4 IAEA 140 (Sea plant) 80 170 28 32 29±70 BCR-150(Dry milk) 52 96 109 8.4 7.9 7.9 9.4±1.7-14 BCR-184(Beef) 29 59 100 2.3 2.5 3.1 2.6±0.60 www.brownfields2011.org

16 www.brownfieldstsc.org ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + 1. Best selectivity for Mercury (Zeeman correction). 2. Lowest Quantification Limit, 3. Real time measurements with MS Windows dataloging. 4. Wide measurement range, 0.000005 - 0.1mg/M 3 5. Internal calibration and field performance verification cell 6. Simple to operate 7. Low maintenance with 48 hours repair/replacement policy www.brownfields2011.org

17 www.brownfieldstsc.org ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + DIRECT MERCURY DETERMINATION IN BIOLOGICAL SAMPLES A, abs. Time, sec Mercury determination in a sample of hair. A – sample weight 12 mg B – sample weight 6 mg 1 – analytical signal 2 – background absorption www.brownfields2011.org

18 www.brownfieldstsc.org ANALYTICAL INSTRUMENTATION Continuous Mercury Emission Monitoring with OL-915-CEM DIRECT MERCURY DETERMINATION IN THE FIELD Field laboratory Insertion of a sample in the instrument. Analysis time 1 minute. No autosampler required. Throughput up to 30 samples per hour. www.brownfields2011.org

19 www.brownfieldstsc.org DIRECT MERCURY DETERMINATION IN THE FIELD MERCURY DETERMINATION with RA-915 + Gas production site Landfill siteSpill ANALYTICAL INSTRUMENTATION www.brownfields2011.org

20 www.brownfieldstsc.org MERCURY DETERMINATION with RA-915 + ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + On-Site mercury soil testing for Environmental Technology Verification Program Milestone DMA 254 MERCURY DETERMINATION with RA-915 + www.brownfields2011.org

21 www.brownfieldstsc.org MERCURY DETERMINATION with RA-915 + ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + On-Site mercury soil testing for Environmental Technology Verification Program MERCURY DETERMINATION with RA-915 + www.brownfields2011.org

22 www.brownfieldstsc.org MERCURY DETERMINATION with RA-915 + ANALYTICAL INSTRUMENTATION MERCURY DETERMINATION with RA-915 + MERCURY DETERMINATION with RA-915 + During the Demonstration, the RA-915+/RP-91C combination exhibited the following desirable characteristics of a field mercury measurement device: (1)good accuracy compared to SRMs, (2)good precision, (3) good sensitivity, (4) high sample throughput, (5) low measurement costs, and ease of use. The Demonstration findings collectively indicated that the RA-915+/RP-91C combination is a reliable field measurement device for mercury in soil and sediment. www.brownfields2011.org