Measuring CCD-Forked Sensor GS 754B. Leuze electronic | GS 754B-27mm | Stand: 2011 NEW Features:  Robust zinc die-cast housing  Flush integrated optics.

Similar presentations


Presentation on theme: "Measuring CCD-Forked Sensor GS 754B. Leuze electronic | GS 754B-27mm | Stand: 2011 NEW Features:  Robust zinc die-cast housing  Flush integrated optics."— Presentation transcript:

1 Measuring CCD-Forked Sensor GS 754B

2 Leuze electronic | GS 754B-27mm | Stand: 2011 NEW Features:  Robust zinc die-cast housing  Flush integrated optics cover  Turning connector 90°  Well-defined bearing faces for distortion-free fastening  Switching output parameterisable PNP, NPN, Push-Pull  Teach input parameterisable for PNP and NPN logic  Protection class IP 65 (previously IP 54)  Detection of transparent objects Measuring CCD-Forked Sensor GS 754B/…-27mm

3 Turning connector 90° M12, 5pin Flush integrated optics cover Leuze electronic | GS 754B-27mm | Stand: 2011 NEWS in detail: Well-defined bearing faces Measuring CCD-Forked Sensor GS 754B/…-27mm

4 Leuze electronic | GS 754B-27mm | Stand: 2011 Measuring CCD-Forked Sensor GS 754B/…-27mm Key Features:  Measurement field: 25mm  Mouth width: 27mm (previously with protection glasses = 27mm)  Mouth depth: 42mm  Resolution: 0,1mm (mode 1…5) / 0,014mm (mode 7)  Repeatability: ± 0,03mm  Linearity: ± 0,36mm  Minimum object diameter: 0,5mm  Response time: min. 12ms (mode 7) min. 2,5ms (mode 7 + foil „F“)

5 Leuze electronic | GS 754B-27mm | Stand: 2011 Measuring CCD-Forked Sensor GS 754B/…-27mm Interface options  Analog output, Pin 4: 4 … 20mA, 2 … 10V (mode 1…5 = calibrated values) 0 … 21,37mA, 0,04 … 9,8V (mode 7 = not calibrated, direct transfered from CCD-array, 14µm steps)  Serial output, Pin 4:RS 232  Serial output, Pin 2 + Pin 4: RS 422  Config. In- or Output:Pin 2 (PNP, NPN, Push-Pull or TeachIn)

6 Leuze electronic | GS 754B-27mm | Stand: 2011 Edge measuring: opaque medium CCD-array-signal Calculation of min/max values Threshold value set between minima/maxima Signal across threshold = measured edge All pixels are readed by the AD-convertor U s x x Measuring CCD-Forked Sensor GS 754B/…-27mm Response time: minimally 12ms (mode 7) Resolution: 0,1mm (mode 1…5) / 0,014mm (mode 7) Repeatability: ± 0,03mm

7 Leuze electronic | GS 754B-27mm | Stand: 2011 Edge measuring: transparent medium The first detected signal which is lower than the threshold value gives measured edge position! There are no arithmetic instructions – „without AD- converter direct to the comparator“ Response time: minimally 2,5ms (mode 7) Resolution: 0,1mm (mode 1…5) / 0,014mm (mode 7) Repeatability: ± 0,03mm U s 1 Measuring CCD-Forked Sensor GS 754B/…-27mm 1

8 Leuze electronic | GS 754B-27mm | Stand: 2011 Fields of applications Edge detection Web guiding Positioning Diameter measuring Single and multiple object detection Non-continuous objects Transparent objects Measuring CCD-Forked Sensor GS 754B/…-27mm

9 Leuze electronic | GS 754B-27mm | Stand: 2011 Measuring CCD-Forked Sensor GS 754B/… - Applications Edge detection and Position control  Detection of opaque, not transparent medium, …  …as well as transparent foils …  Transmission degree: 11 %  respectively foils with a thickness of ≥ 0,1mm

10 Leuze electronic | GS 754B-27mm | Stand: 2011 Measuring CCD-Forked Sensor GS 754B/… - Applications Non-continuous objects  Special analysis function „Edge analysis at patched objects“ Evaluation of the „first“ incoming edge

11 Leuze electronic | GS 754B-27mm | Stand: 2011 Diameter and Position Analysis  Detection of up to 3 objects with diameter > 0,5mm  Resolution 0,1mm - mode 1-5  Resolution 0,014mm if mode 7 is chosen Measuring CCD-Forked Sensor GS 754B/… - Applications

12 Leuze electronic | GS 754B-27mm | Stand: 2011 Config. table: Measuring CCD-Forked Sensor GS 754B/…-27mm

13 Leuze electronic | GS 754B-27mm | Stand: 2011 Selection table: Measuring CCD-Forked Sensor GS 754B/…-27mm New B-types 50115807501158065011580950115803 New B-types GS 754B/D24-27-S12 GS 754B/D3-27-S12 GS 754B/V4-27-S12 GS 754B/C4-27-S12 RS232 x RS422 x OutputAnalog Voltage x Analog Current x PNP, NPN, Push-Pull x xx InputTeach: PNP or NPN Logic x xx Edgexxxx Detection ofDiameterxxxx Transparent objectsxxxx OptionsParametrisation interface 10/18... 30 V DC1111 GND3333 earth5555 Pin assignmentInput / Output2 22 Analog output 44 TxD4 Tx- 2 Tx+ 4

14 Leuze electronic | GS 754B-27mm | Stand: 2011 Overview – cross reference – „previous / new“: Measuring CCD-Forked Sensor GS 754B/…-27mm New B-types 50115807501158065011580950115803 New B-types GS 754B/D24-27-S12 GS 754B/D3-27-S12 GS 754B/V4-27-S12 GS 754B/C4-27-S12 previous types 50104280501042815010320650102981 previous types GS 754 M/D-29/42-104-S12GS 754 M/D-29/42-204-S12 GS 754 M/V-29/42-504-S12GS 754 M/V-29/42-604-S12