Download presentation
Presentation is loading. Please wait.
Published byLesley Underwood Modified over 8 years ago
1
1 Powerware 9120 700 VA – 3kVA Nonstop perfect power for networks, web servers and telecommunications applications
2
2 The Powerware 9120 is the continuation of Powerware’s commitment to delivering innovative technology Developed for global market Meets the uptime demands in a 24/7 world Combines high reliability with low cost of ownership Incorporates proven technology previously only available at high kVA levels Powerware 9120 Applications
3
3 Intelligent power protection for: Telecommunications/PBX Information Technology (heavily configured servers, including UNIX, NT, AS/400, etc.) Internetworking (hubs, routers, ATM switches) Industrial applications Manufacturing process control Banks and security systems And more... Powerware 9120 Applications
4
4 Key Features True double conversion online technology Simple installation and operation Intuitive LCD screen provides real-time updates of UPS status USB-ready for serial & SNMP communications Advanced Battery Management (ABM™) Extended runtime capability with external battery packs Hot-swappable batteries Load segments Network transient protector High Efficiency Mode Robust Overload Tolerance Software Suite CD Ten-year pro-rated warranty (U.S. and Canada) Powerware 9120
5
5 Product Snapshot Rating: 700VA – 3kVA Voltage: 120V (user selectable for 100, 110, 120 and 127 Vac); 230V (user selectable for 200, 208 220, 230 and 240 Vac) Frequency: 50/60 Hz (auto-sensing) Configuration: Tower
6
6 The Powerware 9120 delivers power protection from all 9 of the most common power problems that threaten your equipment and data Power failuresHigh voltage spikes Power sagsFrequency variations Power surgesSwitching transients BrownoutsHarmonic distortion Line noise Series 9 Power Protection
7
7 Product Overview Input 120/140/160 Vac-276 Vac (700-3000VA) Frequency 45 - 65 Hz Output 100/110/120/127 208/220/230/240 Vac +/- 2% Efficiency at full load 86-89% depending on model Overload capability; 100-125% 1 min 126-150% 10 sec Bypass Transfer time <4 ms Battery Internal battery 6 min at full load, 2kVA 12min With one EBC approx. 30 min, with two EBC approx. 60 min at full load Specifications
8
8 True double conversion online design –Meets IEC standard 6204-3 guidelines for Class 1 double conversion online UPS –Total independence and complete isolation between input and output for voltage and frequency Double conversion online is universally recognized as the most reliable topology Powerware 9120
9
9 Front Panel Display Starts Up/Shuts down the UPS UPS ON On Battery On Bypass Alarm LCD Display; 16 characters X 1 line Scroll/meters/UPS select settings Scroll UPS Settings/Select UPS setting parameter User interface Informative user interface with LCD display, four LED and audible alarms Easy to use and configure to meet your application needs
10
10 Powerware 9120 The UPS is only as good as the batteries that support it. Therefore, we rely on the best technology available to prevent unexpected battery disruptions. Hot-swappable batteries Advanced Battery Management™ Extended run time (external battery modules) Accurate battery testing Advanced warning of battery end-of-life
11
11 Hot-Swappable Batteries You can hot-swap batteries without powering down the critical load. This makes it possible to extend the life of your UPS without returning it for service. 1. Remove front panel 2. Remove battery plate 3. Withdraw battery cartridge and replace battery
12
12 Advanced Battery Management (ABM) Doubles battery service life by charging only when needed Optimizes recharge time Does not trickle charge & starve the electrolyte Microprocessor controlled - Only true & automatic battery check (periodic, controlled discharge) for most accurate advanced failure protection Sleep Feature - no unnecessary battery “drain”
13
13 ABM Diagnostics Accurate battery runtime predictions Actual runtimes are compared to ideal runtime curve programmed into UPS Advanced warning When disparity between runtime curves reaches a predetermined point, UPS provides up to 60 days warning of the end of useful battery service life
14
14 ABM: 3-Stage Charger 1. Rapid recharge to approximately 90% Restores batteries quickly UPS is ready for next power outage Adaptive charger control: adjusts battery charging algorithm to quality of AC input 2. Float charge to 100% Completely charges batteries, but prevents overcharging 3. Rest mode With charger turned off, UPS conducts accurate tests to monitor battery health and provide accurate runtime predictions
15
15 Product overview Extended backup times External Battery Modules (EBMs) with two strings of batteries are available for all models One external battery module gives approx 30 min backup time with full load ( > 60 min with 50% load). Recharge time approx 15 hours Two external battery modules gives approx one hour back uptime with full load (> two hours with 50% load). Recharge time approx 24 hours Battery modules dimensions same as UPS dimensions Up to 2 EBMs can be connected to 700/1000/1500VA models Up to 5 EBMs can be connected to 2000/3000VA models
16
16 Backup table Battery Run Time Chart (in minutes full load/half load)* * Up to 2 EBMs can be connected to 700/1000/1500VA models and up to 5 EBMs can be connected to 2000/3000VA models. Runtime chart provides typical information. Runtimes are approximate and may vary with equipment, configuration, battery age, temperature, etc. VAStandard Internal1 EBM2 EBMs3 EBMs4 EBMs5 EBMs Batteries 7007/1834/7064/140 10007/1836/8066/155 15007/1829/6756/130 200012/3449/10793/195140/310192/403240/504 30006/1530/7057/12887/191120/264148/325
17
17 Rear Panel USB Port RS232 Port Communication Expansion Slots Network Transient Protector Battery Connector Cooling Fan Circuit Protector Input Remote Emergency Power Off (REPO) Individual control of two Load Segments Powerware 9120 1000VA Shown
18
18 Rear Panel: 120V & 208V Models
19
19 Rear Panel: 230V Models PW 9120 700i/1000i, 230V PW 9120 1500i, 230V PW 9120 2000i, 230VPW 9120 3000i, 230V
20
20 Load Segments All models have two load segments Power down sequencing of Load Segments Extends runtime for critical devices Power up sequencing of Load Segments Orderly power up of connected devices Scheduled on/off times Turn off equipment for security and power conservation
21
21 During an extended power failure, you can extend runtime for critical devices by shutting down non- vital equipment, such as monitors 60% of load Load Segments: Shutdown
22
22 Load Segment: Rebooting Reboot separate Load Segments without shutting down the entire UPS Load Segment 2: Server 2 Load Segment 1: Server 1 Locked up server
23
23 Power Scheduling Configuration Configure on/off times for each Load Segment or the entire UPS Attach computer that controls UPS to the correct Load Segment Configure power up sequencing Set power down sequence in the event of a power failure Load Segment
24
24 Software Bundle Powerware Software Suite The industry’s most comprehensive software bundle, The Powerware Software Suite, is free and included with every Powerware. Software Wizard guides you through software selection and installation. In addition to multimedia demonstrations, product data sheets, and video clips, the Software Suite contains the following power management software: LanSafe III & CheckUPS Network UPS shutdown software OnliNet™ SNMP-based network UPS shutdown and monitoring software PowerVision® (30-day trial version) UPS performance analysis and monitoring software Foreseer® (demonstration) facility and data center management software Free updates on www.powerware.com
25
25 Product Overview RS232 serial communication port USB port (you cannot work with USB and RS232 at the same time) Slot for Connectivity options (work in parallel with either RS232 port or USB port SNMP/WEB card for option slot AS/400 Relay card for option slot REPO (Remote Emergency Power Off) port shuts off the outputs Remote Interfaces SNMP/Web card shown
26
26 Remote Interface ConnectUPS SNMP/WEB card for option slot Monitor UPS status and meters through browser interface Integration to Network Management Systems with SNMP Manage and control the UPS through Web and SNMP Initiate computer shutdown in case of prolonged power failure
27
27 Remote Interface AS/400 Relay card for option slot Shutdown for IBM AS/400 Integration to industrial environment and building management systems True switching relays 15 pin D connector
28
28 Triple Power Warranty Gold Plans for extended coverage are also available 10-Year Pro-Rated Warranty (2 years inclusive) $25,000 Load Protection Guarantee 60-Day Money Back Guarantee
29
29 Model PowerInput/OutputInput/OutputDimensions NumberRatingVoltage 1 Connection(s) ( H x W x D) Weight Model Selection Guide (Domestic) 700 VA/ 5-15P/ PW9120 700 490 Watts 120 VAC (4) 5-15R 9.6 x 6.2 x 16.2 in. 13.2 lb 1000 VA/ 5-15P/ PW9120 1000 700 Watts 120 VAC (4) 5-15R, (2)5-20R 9.6 x 6.2 x 16.2 in. 16.1 lb 1500 VA/ 5-15P/ PW9120 1500 1050 Watts 120 VAC (4) 5-15R, (2)5-20R 10.8 x 6.7 x 17.5 in. 21.1 lb 2000 VA/ 5-20P/ PW9120 2000 1400 Watts 120 VAC (6) 5-20R 14.2 x 8.6 x 18.6 in.37.2 lb 3000 VA/ L5-30P or Hardwired/ PW9120 3000 2100 Watts120 VAC (4)5-15R, (2)5-20R, 14.2 x 8.6 x 18.6 in.40.5 lb (1) L5-30R or Hardwired PW9120 3000 3000 VA/ 208 VACL6-20P/ 2100 Watts (2)L6-15R, (1)L6-20R, 14.2 x 8.6 x 18.6 in.40.5 lb (1)L6-30R
30
30 Model PowerInput/OutputInput/OutputDimensions NumberRatingVoltageConnection(s) ( H x W x D) Weight Model Selection Guide (International) 700 VA/ IEC-C14 10A/ PW9120 700i490 Watts 230 VAC (4) IEC-C13 9.6 x 6.2 x 16.2 in. 13.2 lb 1000 VA/ IEC-C14 10A/ PW9120 1000i700 Watts 230 VAC (4) IEC-C13 9.6 x 6.2 x 16.2 in. 16.1 lb 1500 VA/ IEC-C14 10A/ PW9120 1500i1050 Watts 230 VAC (4) IEC-C13 10.8 x 6.7 x 17.5 in. 21.1 lb 2000 VA/ IEC-C14 10A/ PW9120 2000i1400 Watts 230 VAC (4) IEC-C13, 14.2 x 8.6 x 18.6 in.37.2 lb (1) IEC-C19 3000 VA/ IEC-C20 16A/ PW9120 3000i2100 Watts230 VAC (1) IEC-C13, 14.2 x 8.6 x 18.6 in.40.5 lb (4) IEC-C13