2 INVENTORY Teledyne ~ 80 Pitch Adapters SLAC 87 Pitch Adapters No flight TMCM’s have been manufactured using any Pitch Adapters from these two lots. MIP-1 yield is currently 0% from a production lot of 18 boards.

3 PARLEX, SAN JOSE Parlex to provide lot to lot data today. Lots manufactured early 2004 are acceptable. ExpressTech has always been the plater.

4 LOT 6228-01X NOV. 15, 2004 Sample size 1 Au thickness microinches: –Spread: 22.1 – 21.4 –Mean: 21.7 microinches –Dwg spec. 10 microinches Au

5 LOT 6228-01X NOV. 15, 2004 Sample size 1 Ni thickness microinches –Spread 130.3 – 168.5 –Mean 149.4 microinches –Dwg spec. 150 microinches Ni

6 LOT 5887-04 SEPT. 9, 2004 Sample size 1 Au thickness microinches –Spread: 24.9 – 30.6 –Mean: 27.8 microinches –Dwg spec. 10 microinches Au

7 LOT 5887-04 SEPT. 9, 2004 Sample size 1 Ni thickness microinches –Spread: 162.1 – 204.7 –Mean: 183.4 –Dwg spec. 150 microinches Ni