1 Beam Wire Scanner for PS/SPS/PSB Current status and Schedule Dmitry Gudkov BE-BI-ML

2  Status of the Beam Wire Scanner prototypes for SPS  Electric Motor for the Beam Wire Scanners  Beam Wire Scanner Prototype for Booster. Integration Study  Beam Wire Scanner Prototype for Booster. Schedule  Beam Wire Scanners for PS/SPS/PSB. Series Production. Schedule Contents

3 Beam Wire Scanner prototypes for SPS PrototypeLocationTests foreseenPicture Prototype 1SPS Tests with beam Prototype 2ML Lab  RF test, Calibration (BE-BI-BL)  Vacuum tests (TE-VSC-BVO) Leak tightness test Outgassing Residual gas analysis  Tests of optical system (BE-BI-BL)  Vacuum-mechanical tests (TE-VSC-BVO, BE-BI-ML) Cold welding (bearings) Outgassing (bearings in motion) Bake-out  Mechanical reliability (˜10000 cycles.) (BE-BI-ML, BE-BI-BL)  Thermal test (BE-BI-ML, BE-BI-BL) Test benchesBL Lab Qualification of control system Qualification of electrical motor

4 Electric Motor for the Beam Wire Scanners Requirements for new motor selection: New motor will be the same in beam wire scanners for PS/SPS/PSB so should provide torque sufficient to accelerate the wire to linear speed 20 m/s in both configurations: 182.5 mm (PS/SPS) and 150 mm (PSB) mm forks; The desired motor should be based on the standard market solution which will be available for many years; The rotor will be located in vacuum and must be vacuum compatible; the use of any glue, other adhesives or insulating materials is not possible. Solid core rotor should be used. The minimum motor air gap should be large enough to allow the introduction of a low magnetic permeability stainless steel wall (vacuum chamber) with the thickness of 0.3 mm. The moment of inertia of the rotor should be minimized in order to reduce the required acceleration torque; Features for mounting the rotor on the shaft (key-slots, holes, etc.) should be considered in the design; The whole motor must withstand an ionizing radiation of 1 kGy/year. Once the motor is selected and approved the detailed design of the prototype for PSB can be launched as well as design for series production for PS/SPS/PSB The motor currently used is obsolete and will not be available for purchasing

5 Beam Wire Scanner prototype for Booster. Integration study Paolo Magagnin Can be used as input for detailed mechanical design With “short” motor With “long” motor

6 Beam Wire Scanner Prototype for PS Booster. Schedule

7 Series Production of Beam Wire Scanners (PS, SPS, PSB). Schedule PS x 5; SPS x 5; PSB x 8 (18 instruments in total)

8 Thank you for your attention! Questions? …Discussion...