Introduction to Titration Go to browse and set to full screen.

Slides:



Advertisements
Similar presentations
The Care and Feeding of Burets
Advertisements

Determination of Calcium Carbonate in Eggshells
Purpose Background - The Power of Antacids
SURVEY OF CHEMISTRY LABORATORY I DETERMINATION OF THE DENSITY OF WATER
SURVEY OF CHEMISTRY LABORATORY I CHEM 1151L ANTACID EVALUATION.
Antacids Titration Lab. Teacher Preparation 1.Gather all materials and place them in trays at each lab station. Have extra flasks, beakers & graduated.
Standardising potassium permanganate solution with iron(II) sulfate
Titration By Dr H W Winter.
Pipetting Pipetting involves drawing a liquid into a pipet and allowing liquid to drain from the pipet in a controlled manner. Pipetting is used to quantitatively.
1 Objective:The objective of this experiment is to determine the mass of acetylsalicylic acid (ASA) in an Aspirin tablet. Chemicals Potassium hydrogen.
Laboratory Techniques I: Dilution Go to browse and set to full screen.
Titration Pre-lab.
Volumetric Analysis Apparatus. The Volumetric Flask.
Exp 4C: How Much Acetic Acid is in Vinegar?
Common Laboratory Glassware and Volumetric Glassware Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit.
Volumetric Analysis Apparatus. The Volumetric Flask.
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
CHM 101/102 Laboratory Manual Water Hardness: Determination with EDTA General Chemistry 101/102 Laboratory Manual University of North Carolina at Wilmington.
Introduction to the most commonly used glassware and equipments in the lab.
Introduction to Laboratory Equipment By Douglas Rittmann, Ph.D., P.E. Water/Wastewater Consultant At University of Texas at El Paso CE 4153 January 31,
Laboratory Techniques II: Titration
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 mLs of standarized NaOH solution. Make sure all.
How to do a Manual Titration. Rinse the Burette with 2-3 mL of standardized NaOH solution. Make sure all inside walls including the tip are rinsed. Discard.
Performing a titration A bluffers guide! Preparing a standard solution 4 Accurately weigh a weighing bottle, recording the mass 4 Add approximately x.
COMMON LABORATORY EQUIPMENT. FLASKS, BEAKERS, CYLINDERS Erlenmeyer flask beaker Erlenmeyer flasks and beakers are used for mixing, transporting, and reacting,
MLAB 1335 Immunology Serology Terry Kotrla, MS, MT(ASCP)BB
Experimental Procedure. Overview The supernatant from a saturated calcium hydroxide solution is titrated with a standardized hydrochloric acid solution.
Initial HClFinal HCl HCl added Initial NaOH Final NaOH NaOH added Molarity of NaOH 0.00 mL1.10 mL 3.00 mL5.35 mL 0.85 mL 1.10 mL2.10 mL 1.00 mL0.77 mL.
Lab Equipment. Beaker Beakers are the most versatile glassware in the lab and can be used for just about anything. The volume graduations on beakers should.
I-Ion Exchange Separations: Complexometric Titrations Dr. Prem D. Sattsangi Copyright © 2009.
CHEM 1031 DETERMINATION OF THE PERCENT ACETIC ACID IN A VINEGAR SAMPLE.
Titration and Buffers Chemistry Department Minneapolis Community & Technical College Intro to Chemistry Chem1020 Lab 1.
AcidAcid / Base Titration – K a (HAc)BaseTitration AcidAcid / Base Titration – K a (HAc)BaseTitration Hand in: Pre-Lab and Equilibrium report and Submit.
HCl (aq) + NaOH (aq)  NaCl (aq) + H2O (l)
Acid/Base Titration Thurston High School Chemistry.
Lab Techniques How to do a Manual Titration. Rinse the inside of the Burette Rinse the burette with 2-3 cm 3 of water then with 2-3 cm 3 the solution.
A buret is used to deliver solution in precisely-measured, variable volumes. Burets are used primarily for titration, to deliver one reactant until the.
Some Common Laboratory Glassware Please be careful when using glassware in the laboratory. Wet glassware and wet gloves are slippery. Always read a volume.
Vitamin C tablets vs. Citrus fruit juice
(Introduction ,The Equipment ,The Process , Calculations )
Titration A quantitative experiment to determine the concentration of an acid or a base.
Experiment 8. Thermodynamics of the Dissolution of Borax
Valdosta State University Experiment 5 NaOH Standardization Valdosta State University.
General chemistry Lab 2. Chemistry Analytical Chemistry Gravimetric Analysis Oxidation and Reduction Reactions Oxidation and Reduction Reactions Instrumental.
Preparing Solutions.
Exp. 10 Vinegar Analysis: Acid-Base Titrations Purpose – To use quantitative analysis and titrations to find the concentration of an acid or base. In this.
Quantitative determination of nickel in a compound Go to browse and set to full screen.
Lab Equipment. These GOGGLES are used to protect your eyes from broken glass, chemicals and flames.
枣庄学院化学化工与材料科学学院 Preparation of Solution. 枣庄学院化学化工与材料科学学院 1. Grasp the basic Method and Operation of Preparing Solution 2. Study the Method of Use about.
Lab 24Date: Acids, Bases and Indicators…oh my! Purpose Background Observe a neutralization rxn & work with indicators. Bases will turn red litmus blue.
Lab Glassware Chemistry Ms. Gomez.
Trinity College Dublin, The University of Dublin Titration Demonstration.
Practical Analytical Chemistry (1) Practical (8) Faculty of Pharmacy Department of Pharmaceutical Chemistry.
NEUTRALIZATION TITRATIONS
How much acid is there in a solution
How to do a Manual Titration
Lab Techniques How to do a Titration.
Analysis of vinegar via titration
Introduction to Titration
Laboratory Techniques: Titration
How to do a Manual Titration
Volumetric Analysis Apparatus.
Common Laboratory Glassware
Volumetric Analysis Apparatus.
Acid/Base Titration Purpose- to find the concentration of four HCl samples, by titrating them with 0.100M NaOH Solution(titrant).
Lesson 6.10 Neutralization and Solution Stoichiometry Mrs. Wilson
Procedures Reading from the text.
Mustard Titration Mrs. Wilson
Acid-Base Titration. Acid-Base Titration. Acid-Base Titration.
Presentation transcript:

Introduction to Titration Go to browse and set to full screen.

three 250 mL Erlenmeyer flasks 100 mL beaker (60 mL of acid) 150 mL beaker (80 mL of base) 50 mL beaker waste beaker glass funnel indicator mL volumetric pipet bulb buret stand buret clamp

Pour 20 mL of acid solution into the 50 mL beaker and rinse the mL volumetric pipet with it.

Place the pipet bulb on the end of the pipet. Squeeze the bulb to empty out the air.

Place the pipet into the acid solution, slowly releasing the pressure on the bulb.With a pipet bulb withdraw a small quantities of the acid solution. Watch the solution rise in the pipet, do not let any solution get into the bulb. A blue solution was used just for demonstration purpose.

Make sure to place your index finger on the end of the pipet. Once a small quantity of the acid solution is in the pipet, quickly remove the bulb and press down on the end of the pipet with your index finger.

Invert the pipet to a horizontal position. Turn and rotate the pipet so all inside surfaces have come into contact with the solution.

Drain and discard this solution into the waste beaker. Rinse the mL volumetric pipet three times with a small quantities of the acid solution.

Place the pipet into the acid solution and once the solution is above the calibration mark on the pipet, remove the bulb and press down on the end of the pipet with your index finger. Discard the remaining solution from the 50 mL beaker into the waste beaker and pour the 30 mL of fresh acid solution.

Dry the outside of the volumetric pipet with a Kimwipe.

To obtain an accurate reading, you should have the calibration mark (meniscus) at eye level, i.e., your line of sight should be parallel with the mark.

Once the bottom of the meniscus has reached the calibration mark on the pipet, press down firmly with your finger. Release pressure from your finger very slightly so that the liquid level slowly drops (this may take some practice).

Transfer the mL of the acid solution into the clean (rinsed with distilled water) 250 mL Erlenmeyer flask. Repeat the above process two more times.

Add 2-3 drops of phenolphthalein indicator to each Erlenmeyer flask.

Clamp the buret to the buret stand.

close stopcock open stopcock

Rinse the mL buret using a small quantity of the base solution (use the glass funnel to avoid spillage).

Turn and rotate the buret so all inside surfaces have come into contact with the base solution.

Make sure that the tip of the buret is rinsed! Drain and discard the base solution into the waste beaker. Rinse the buret three times with a small quantities of this solution.

Next, fill the buret with the base solution. Remove the funnel and put the waste beaker under the tip of the buret. Open the stopcock and allow some solution to run through (ensure that the buret tip is filled with the base solution and contains no air bubbles).

Close the stopcock and wait a few seconds for drainage to be complete, then note the reading on the buret to two decimal places (V initial ). V initial = 3.78 mL

Place the Erlenmeyer flask under the tip of buret and put the Kimwipe under the Erlenmeyer flask (white background).

Titrate to the end point.

When you are close to the end point use the drop-by-drop approach and rinse the last drop from the tip of the buret at the side of the Erlenmeyer flask with the distilled water.

End point – light pink. Over titrated end point – dark pink.

Close the stopcock and wait a few seconds for drainage to be complete, then note the reading on the buret to two decimal places (V final ). V final = mL

± 0.02 V initial (mL) V final (mL) V used (mL) End-point Run # light pink Run#2 Run #3 [NaOH] = __________ Rinse the buret with water and clean up your work space.