Project: Pulse meter Idea: Use noninvasive infrared light to probe blood pressure and pulse rate in a finger tip. Uses: A variant of this device is used.

Slides:



Advertisements
Similar presentations
An Electronic System Power Supply Example
Advertisements

Lecture 4: Signal Conditioning
1 Electronic Circuits OP AMPs. 2 Electronic Circuits Operational amplifiers are convenient building blocks that can be used to build amplifiers and filters.
To Get a Perfect “A”… An Engr. 311 Project by Corrin Meyer.
Describe and analyze the operation of several types of comparator circuits. Describe and analyze the operation of several types of summing amplifiers.
FREQUENCY SHIFT KEYING
Introduction to electronics lab ENGRI 1810 Using: Solderless prototype board (white board) Digital multimeter (DMM) Power Supply Signal Generator Oscilloscope.
Electricity and Circuits
Pulse Detector Ramiro Duarte, Clayton Greenbaum Prof. Betty Lise Anderson.
Alex Bode Emmanuel Cordova Mikel Dualos Christa Hamilton Medical Instrumentation Spring 2011.
Revision analog electronics
Oscillators with LC Feedback Circuits
Relaxation Oscillators
Experiment 11: An Inverting Amplifier
Part A: Controlling Oscillation Frequency with Capacitors and Resistors Part B: Diodes and Light Experiment Timer.
Design Realization lecture 14 John Canny/Dan Reznik 10/9/03.
Learning about AC signals ES 110. Basic Components  Function generator  LED  Relay  Speaker  Pot  Ohm ’ s Law  Drawing the circuit  Schematic.
1 Announcements l Bring motors to lab this week. l Bring eight 1N4001 diodes to lab per team. Get them at the Scientific Supply Store (2 nd Floor Sciences.
Lightning Detector Michael Bloem December 5, 2002 Engr 311.
M.S.P.V.L. Polytechnic College, Pavoorchatram
Pulse Width Modulation (PWM) LED Dimmer Circuit
Op-Amp Oscillator. Reading Schematics: Battery What’s this?
Pulse oximetry is the noninvasive measurement of arterial blood oxygen saturation and heart rate. The Pulse Ox use a spectrophotometric probe. The pulse.
Designs and Implementation Ring Detector circuit Design: Ring Detector circuit Design:
Pulse Width Modulation (PWM) LED Dimmer Circuit
Content Op-amp Application Introduction Inverting Amplifier
Integrator Op Amp Amplifier
Electricity, Electronics And Ham Radio “Kopertroniks” By Nick Guydosh 4/12/07.
ELECTRONICS PRIMER. Assignment: WEB-based Electronics Tutorial Basic definitions Components Ohm's Law LEDs and Transistors Additional electronics tutorials.
Lab #5 Overview Activity #1 - Simulation of an Op-Amp inverting amplifier Activity #2 - Build and Test the Op-Amp inverting amplifier Activity #3 - Determining.
Chapter 2 Basic Concepts of Electronics. Figure 2.1 Electric current within a conductor. (a) Random movement of electrons generates no current. (b) A.
electronics fundamentals
Electricity and Magnetism Topic 5.2 Electric Circuits.
Ch4 Electronic Components Circuit/Schematic Symbols.
Electric Currents Topic 5.2 Electric Circuits. Electromotive Force Defining potential difference Defining potential difference The coulombs entering a.
Project: Pulse meter Idea: Use noninvasive infrared light to probe blood pressure and pulse rate in a finger tip. Uses: A variant of this device is used.
Chapter 19 Electronics Fundamentals Circuits, Devices and Applications - Floyd © Copyright 2007 Prentice-Hall Chapter 19.
Created by Jimmie Fouts Houston County Career Academy for.
Alternating Current Electricity Lesson 11. Learning Objectives To know what is meant by alternating current. To know how to calculate the rms value of.
Some Concepts from the Labs RC Filter and LabVIEW lab Function generator and internal resistance Root-Mean-Square (rms) value of a sinusoidal voltage Oscilloscope.
CHAPTER 11 Op-Amp Applications. Objectives Describe and Analyze: Audio mixers Integrators Differentiators Peak detectors Comparators Other applications.
Feedback: Part C – Oscillators Slides taken from:
Electronic Components Circuit/Schematic Symbols. RESISTOR Resistors restrict the flow of electric current, for example a resistor is placed in series.
Introduction to Operational Amplifiers
Non - Inverting Amplifier
Project: Repressilator
OPTICAL SENSORS 13 JULY 2004 Chung Hsieh. Basics Operation An Light Emitting Diode (LED) sends out light which bounces back from the target. Exciting.
UCLA IEEE NATCAR 2004 SUMMER CLASS Magnetic Sensors & Power Regulation.
1.0 LINEAR DC POWER SUPPLY The importance of DC Power Supply Circuit For electronic circuits made up of transistors and/or ICs, this power source.
BASIC INSTRUMENTS - oscilloscopes
1 COMPARATORS Function: Compares two input voltages and produces an output in either of two states indicating the greater than or less than relationship.
Reverse Parking Sensor Circuit.
EXAMPLE 2 – PHOTODIODE A photodiode is a semiconductor device that converts light into current. The current is generated when photons are absorbed in the.
Lab 3 Slide 1 PYKC 19 May 2016 EA1.3 - Electronics Laboratory Experiment 3 Operational Amplifiers Peter Cheung Department of Electrical & Electronic Engineering.
Feedback: Part C – Oscillators Slides taken from:
(3) Signal Conditioning
The university of Lahore Department of computer Engineering Electric Network Analysis Project Tittle : Audio tone IR transmitter and receiver Group.
(EVENING ON TO MORNING OFF)
Pulse Detector Ramiro Duarte, Clayton Greenbaum Frank Paynter
SUN SET TO SUN RISE LIGHTING SWITCH (EVENING ON TO MORNING OFF)
Fault detection Lecture (3).
Potential Divider Aims What is a potential divider
Op Amps and Voltage Dividers
Chapter 4 – Operational Amplifiers – Part 2
8.5 Modulation of Signals basic idea and goals
Which of the following devices or circuits changes an alternating current into a varying direct current signal? A. Transformer B. Rectifier C. Amplifier.
Electricity and Circuits
Electronic systems 7.
Presentation transcript:

Project: Pulse meter Idea: Use noninvasive infrared light to probe blood pressure and pulse rate in a finger tip. Uses: A variant of this device is used routinely in hospitals and is called a pulse-oximeter. Components: – Comparator – Amplifiers and filters – Light emitting diodes and photosensors

Operational Amplifier LM358 Opamp is used in many circuits to compare voltages, amplify voltages, or to amplify currents. One physical DIP package contains two opamps. Each opamp has many transistors, but we can usually ignore the internal complexity. Opamps require power to run, in our case +5 volts on pin 8 and -5 volt on pin 4. From:

LM358 as an amplifier Vout= Vin * (1 + Rout/Rin) Vout is limited to being no bigger than +9 volt and no smaller than -1 volt. Special case: if you leave out Rin and make Rout=zero (a wire) then Vout=Vin. Then why bother? LM358 acts a current amplifier with a gain of several million. From

LM358 as an amplifier and high-pass filter Let  =RC. And f be the sine wave frequency of the signal generator. Define  =2  f. Vout= Signal_gen * (1 + Rout/Rin) *  /sqrt(1+     ) See plot for  =1, Rin=infinity At zero frequency there is zero output. Another way of say this is that the circuit ‘blocks’ steady (DC) signals. This circuit is very useful for getting rid of unwanted steady signals which tend to be amplified too much and block the desired small, changing signal.

LM358 as an amplifier and band-pass filter Let  =RC and   =RoutCout. And f be the sine wave frequency of the signal generator. Define  =2  f. Vout= Signal_gen*(1+Rout/Rin)*  /sqrt(1+     )*  /sqrt(1+      ) This circuit is very useful for getting rid of unwanted steady signals which tend to be amplified too much and block the desired small, changing signal. It also gets rid of noise at higher frequencies.

IR LED and IR sensor The clear device to the left is an infrared emitting LED. amount of light  amount of current L = k*I Wavelength (color) sets voltage. For IR, V is around 1.2 volts Only works one direction Use your cell phone camera to see if it operates. The black device to the right is an IR sensor (phototransistor) Current flows when light is absorbed: I = k*L Your finger absorbs more IR if there is more blood. Each heart beat sends more blood into your finger and changes the IR absorption, but the change is small.

LM358 testing part 1 Testing: – Build a noninverting amplifier with a gain of 101 using resistors between 100 ohms and 1Mohm. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generator to produce a 0.01 volt amplitude sine wave, then hook one scope probe to the input. You may need to build a two-resistor voltage divider to make an amplitude this small. – Measure the output as you vary frequency. Is it constant?

LM358 testing part 2 Testing: – Build a noninverting amplifier with a gain of 11. A high pass filter at 1 radian/sec and low pass at 100 radians/sec. Use power supply voltages of +5 and -5 volts. – Test it by connecting the input to the waveform generator and the output to the scope as shown below. – Set up the waveform generator to produce a 0.1 volt amplitude square wave, then hook one scope probe to the input, another to the output and explain what you see as you vary the frequency. – Vary Cout and show what happens to the output at higher frequencies.

LM358 testing part 3 Testing: – Build a comparator as shown to the right. The circuit compares two – voltages – Vout = 5 volts if Vin>Vthreshold Vout = -5 volts if Vin<Vthreshold – Test it by connecting the input Vin to the waveform generator with a frequency of around 1 Hz and output amplitude of around 1 volt. – Adjust the potentiometer until the LED blinks.

LED and sensor testing Build the circuit shown, noting that the long lead of each device is marked with an asterisk. Hook the scope up to the output between the 20k resistor and the photosensor. Be sure that the LED and sensor point at each others rounded ends. Putting your finger between the two should result in a voltage change. How much?

Overall Scheme Use sensor to detect blood flow Amplify and filter sensor output so that easier to detect the heart beat. Use a comparator to detect actual beat and blink an LED. Optional -- implement an auto threshold circuit to replace the potentiometer. Optional – build an oscillator and make the circuit beep for every heart beat. Note that cold fingers have very little blood flow, so the circuit works poorly.