SoLID Magnet Options Paul E. Reimer 06 June 2011 Physics Division Argonne National Laboratory The real work has been done not by me but by a growing Monte.

Slides:



Advertisements
Similar presentations
Robert Michaels HAMC Hall A Analysis Workshop 09 C HAMC = Hall A Monte Carlo ROOT / C++ Design Somewhat like SAMC & genercone For HRS only. Uses LeRose.
Advertisements

General Considerations Jian-ping Chen SoLID-SIDIS Collaboration Meeting.
Panda Solenoid Timelines. General Layout constraints and HOLD POINTS.
SoLID Magnet Options (and unstudied calorimeter thoughts) Paul E. Reimer 28 January 2011 Physics Division Argonne National Laboratory.
SoLID Baffle and Background Update Zhiwen Zhao UVa 2013/05/23.
A polarized solid state target for photon induced double polarization experiments at ELSA H. Dutz TR16 Bommerholz Hartmut Dutz, S. Goertz, A.
Quadrupole Magnetic Design for an Electron Ion Collider Paul Brindza May 19, 2008.
Physics 1402: Lecture 21 Today’s Agenda Announcements: –Induction, RL circuits Homework 06: due next MondayHomework 06: due next Monday Induction / AC.
Ricardo GoncaloZEUS Week - London June Neutral Current 99/00 e + p Analysis Status Ken Long Matthias Moritz Henning Scnurbusch Ricardo Gonçalo Thanks.
MARS flux simulations - update Sergei Striganov Fermilab June 3, 2009.
GlueX Simulations Status Report on CD3 geometry Richard Jones GlueX Collaboration Meeting, Newport News, January 10-12, 2008.
Magnetic Field Studies Dan Karmgard for the HCAL RBX Group.
1 Stratified sampling This method involves reducing variance by forcing more order onto the random number stream used as input As the simplest example,
Optimization of the SiD Detector ? Adam Para, Sept. 18, 2006.
Induction and Inductance Chapter 30 Magnetic Flux.
Zhiwen Zhao (UVa), Paul Reimer (ANL) SoLID Collboration Meeting 2013/03.
SoLID Simulation Zhiwen Zhao 赵志文 University of Virginia 2011/8/9
E. Todesco PROPOSAL OF APERTURE FOR THE INNER TRIPLET E. Todesco CERN, Geneva Switzerland With relevant inputs from colleagues F. Cerutti, S. Fartoukh,
LCWS14 Benoit CURE - CERN/PH Dept.1 International Workshop on Future Linear Colliders October 2014 Organized by the Vinca Institute of Nuclear.
Proposed SoLID Organization Structure Chair EB GEM-US Magnet GEM-China Heavy Cherenkov Light Cherenkov Calorimeter Large Angle Calorimeter Forward Reconstruction/
1 Lesson 3: Choosing from distributions Theory: LLN and Central Limit Theorem Theory: LLN and Central Limit Theorem Choosing from distributions Choosing.
14 August Magnetic Field in the ATLAS Muon Spectrometer Masahiro Morii for the ATLAS Group Harvard University Laboratory for Particle Physics and.
SoLID Simulation Zhiwen Zhao UVa Hall A Collaboration Meeting 2011/6/10 1 Introduction Simulation framework Simulation study Introduction Simulation framework.
Zhiwen Zhao (UVa), Paul Reimer (ANL), Many Thanks to Eugene Chudakov, Xin Qian, Jian-Ping Chen, Whit Seay, Robin Wines, Javier Gomez, Will Oren, Rolf Ent.
SoLID baffle update Zhiwen Zhao 2013/04/02. Current Baffle The total distance from plane 1 to 6 is 150cm which is a few cm overlapping with endcap nose.
SoLID simulation Zhiwen Zhao Uva SoLID Collaboration Meeting 2011/6/2 1.
M. Gilchriese - November 12, 1998 Status Report on Outer Support Frame W. Miller Hytec, Inc E. Anderssen, D. Bintinger, M. Gilchriese LBNL.
Optimising Cuts for HLT George Talbot Supervisor: Stewart Martin-Haugh.
S.J. Brooks RAL, Chilton, OX11 0QX, UK Extending FETS with a Ring Electron models are not sufficient for simulating the beam.
Cherenkov Counters for SoLID Z.-E. Meziani on behalf of Simona Malace & Haiyan Gao (Duke University) Eric Fuchey (Temple University) SoLID Dry Run Review,
CEA DSM Irfu - F. KIRCHER - [Seoul Workshop, Feb 16-18, 2009] 1 ILD detector magnet: LoI version F. Kircher, O. Delferrière CEA Saclay, DSM/Irfu/SACM.
Magnets Paul E. Reimer 21 June Paul E. Reimer Magnets First Magnet Dual magnet spectrometer Proposal:SM3 coils and SM12 iron to construct first.
SoLID simulation Zhiwen Zhao UVa 2011/03/25 1. GEMC, written by Maurizio Ungaro, used for CLAS12 2.
SHMS Spectrometer Update Hall C 2008 Users Meeting Paul Brindza January 18, 2008.
RAL, Apr H.Weerts SiD Workshop Summary, Next Steps & Life beyond the LOI H.Weerts Argonne National Lab.
Optics, Tracking, and TOF Status/Update/Roadmap Xin Qian KRL Caltech.
Overview of SoLID Jian-ping Chen SoLID Collaboration Meeting June 13-14, 2012.
Blue Skies Magnets 1.Vertical orbit-excursion FFAG 2.Omni-Magnet for FETS 3MeV ring February 2013Stephen Brooks, ASTC meeting1.
HL-LHC IR Corrector Magnets Design & Construction Activity Giovanni Volpini on behalf of the LASA team CERN, 9 October 2014.
SoLID magnet and yoke by using CLEO-II Zhiwen Zhao 2012/07.
2 July 2002Realistic Fields for a Ring Cooler Magnet System -- S.Kahn Page 1 Realistic Fields for a Ring Cooler Steve Kahn 2 July 2002 NuFact’02 Meeting.
Reducing the Iron in the Endcap Yoke of CLIC_SiD Benoit Curé, Konrad Elsener, Hubert Gerwig, CERN CERN, June 2014 Linear Collider Detector Magnet Meeting.
SoLID Background Update Zhiwen Zhao UVa 2013/11/08 1.
Faraday’s Law of Induction Magnetic flux  = A B cos   B A A changing magnetic flux generates an induced voltage (emf = electromotive force) V = [emf]
Muons, Inc. 14 Jan 2010 S. Kahn--IR Quads 1 IR Quadrupoles with Exotic Materials Steve Kahn, Muons Inc. Bob Palmer, BNL Don Summers, Ole Miss.
SoLID Simulation Update Zhiwen Zhao University of Virginia SoLID Collaboration Meeting 2011/10/14 Introduction GEMC Update Simulation Study Summary Introduction.
Update/Overview of SoLID Jian-ping Chen, Jefferson Lab SoLID Collaboration Meeting Dec , 2012.
Magnetic Field Task Dietrich Liko. Overview A lot of progress in the last two weeks I try to summarize the status Discussion on additional.
Magnetic Fields in s/f/ePHENIX John Haggerty Brookhaven National Laboratory.
Practical aspects of small aperture quadrupoles Dr Ben Leigh Tesla Engineering Ltd.
PVDIS baffle Zhiwen Zhao 2013/10/15. Intro Previously, I couldn’t obtain an ideal baffle with the code (makebaf5.C) For the writeup, we used “BaBar more1.
Decision trees. A decision tree is a planning and decision making tool. Decision trees are probability and outcome maps of a scenario. Decision trees.
Shielding the turbomolecular pump and the vacuum gauge 11 June 2013 Kiril Marinov ASTeC, MaRS, DL 1.
Kitakami Side AHCAL Assembly or anywhere in any detector.
2016/9/30 Yasuhiro Infra/CFS mini-ws
Discussion of modification to DID field for detectors with TPC
Summary of Muon Studies Yoke Discussion
Bill Wisniewski SuperB Frascati Meeting September 30, 2010
Target and Horn status report
PVDIS Overview.
DESIGN OPTIONS FOR ORBIT CORRECTORS IN D2 and Q4
SoLID Simulation Zhiwen Zhao (UVa) SoLID Jlab Physics Division
PROPOSAL OF APERTURE FOR THE INNER TRIPLET
CLEO II Magnet in Hall A for SoLID
T. Markiewicz / SLAC MAP at SLAC Working Meeting 2 July 2014
How magnet opening affects PVDIS acceptance
SoLID SIDIS He3 target collimator optimization
Lesson 4: Application to transport distributions
Orbit Correctors in D2 and Q4 Design options
IR Beam Transport Status
Presentation transcript:

SoLID Magnet Options Paul E. Reimer 06 June 2011 Physics Division Argonne National Laboratory The real work has been done not by me but by a growing Monte Carlo Group including: Simona Malace, Seamus Riordan, Lorenzo Zana, Zhiwen Zhao and many others.

Magnet Principles  Must be affordable –Coils already exist –Hopefully comes with useable material for the barrel and upstream flux return yoke  Large enough to give reasonable acceptance –For both PV- and SI-DIS experiments –1.5m radius seems to work –Smaller may work 02 June 2011 Paul E. Reimer 2  Additional current density at coil ends is desirable

Flux Return Design Constraints  Up and down stream coil forces must balance  PV- and SI-DIS angular acceptance  Low Field Detector Area –How large? Extension Ring for reconfiguration? –Max field I this area? –Length of Nose cone? Magnet Principles  Must be affordable –Coils already exist –Hopefully comes with useable material for the barrel and upstream flux return yoke  Large enough to give reasonable acceptance –For both PV- and SI-DIS experiments –1.5m radius seems to work –Smaller may work 02 June 2011 Paul E. Reimer 3  Additional current density at coil ends is desirable

Flux Return Design Constraints  Up and down stream coil forces must balance  PV- and SI-DIS angular acceptance  Low Field Detector Area –How large? Extension Ring for reconfiguration? –Max field I this area? –Length of Nose cone? Magnet Principles  Must be affordable –Coils already exist –Hopefully comes with useable material for the barrel and upstream flux return yoke  Large enough to give reasonable acceptance –For both PV- and SI-DIS experiments –1.5m radius seems to work –Smaller may work 02 June 2011 Paul E. Reimer 4  Additional current density at coil ends is desirable

Flux Return Design Constraints  Up and down stream coil forces must balance  PV- and SI-DIS angular acceptance  Low Field Detector Area –How large? Extension Ring for reconfiguration? –Max field I this area? –Length of Nose cone? Magnet Principles  Must be affordable –Coils already exist –Hopefully comes with useable material for the barrel and upstream flux return yoke  Large enough to give reasonable acceptance –For both PV- and SI-DIS experiments –1.5m radius seems to work –Smaller may work 02 June 2011 Paul E. Reimer 5  Additional current density at coil ends is desirable

Magnets under consideration or “The usual suspects”  Babar  CLEO  ZEUS  CDF  MEGA (Hall D)  New Hall D design 02 June 2011 Paul E. Reimer 6

Magnet Comparison BaBarCLEOZEUSCDFGlue-XNew Old SLAC New Cryostat Inner Radius 150 cm 86 cm150 cm Whatever we need Length345 cm350cm245cm500 cm Central Field 1.49T1.5T1.8T1.47T Flux Return Iron Yes No Cool IconYes No Variation in Current density with z? 2x more in end than central 4.2% more in end than central 40% more in end than central NoYes Available Probably Not?? Probably One will be available Wild guess-- $5M 02 June 2011 Paul E. Reimer 7

Last collaboration meetings and plan of action  Determine if any of the magnets will work –Proof of principle for BaBar magnet from Eugene –Worry: Other magnets do not have current density gradient of BaBar—may cause acceptance problems  Plan 1.Generate other magnets’ field maps with Poisson 2.Quick test of “Worry” above by looking at field integral 3.Check acceptance with Monte Carlo for these field maps a.Switch to GEANT 4 Monte Carlo b.Validate GEANT 4 Monte Carlo by comparison with Eugene’s GEANT 3 Monte Carlo of BaBar c.Generate baffle designs for alternate coils d.Compare a Figure of Merit (after deciding what the FOM is) 1.Decide which magnet to pursue and get it! 02 June 2011 Paul E. Reimer 8

Progress since Last set of meetings  Plan Generate other magnets’ field maps with Poisson Complete for BaBar, CLEO, CDF, ZEUS 02 June 2011 Paul E. Reimer 9

Progress since Last set of meetings  Plan Generate other magnets’ field maps with Poisson Quick test of “Worry” above by looking at field integral 02 June 2011 Paul E. Reimer 10 Paul E. Reimer Credit: Zhiwen and Seamus Qualitatively as expected— Those with less even current density have fields that fall off faster. How does this affect the acceptance?

Progress since Last set of meetings  Plan Generate other magnets’ field maps with Poisson Quick test of “Worry” above by looking at field integral –Check acceptance with Monte Carlo for these field maps Switch to GEANT 4 Monte Carlo Validate GEANT 4 Monte Carlo by comparison with Eugene’s GEANT 3 Monte Carlo of BaBar These two steps involved the most effort and represent a major milestone in this project, but I have no good plot to show you here June 2011 Paul E. Reimer 11 SIDIS Proposal GEANT 3 GEANT 4

Progress since Last set of meetings  Plan 1.Generate other magnets’ field maps with Poisson 2.Quick test of “Worry” above by looking at field integral 3.Check acceptance with Monte Carlo for these field maps Switch to GEANT 4 Monte Carlo Validate GEANT 4 Monte Carlo by comparison with Eugene’s GEANT 3 Monte Carlo of BaBar Generate baffle designs for alternate coils Compare a Figure of Merit (after deciding what the FOM is) 02 June 2011 Paul E. Reimer 12

Conclusion  The status of the magnets in which we are interested has not changed  We now have a tool based in GEANT 4 which will allow for quantitative decisions on magnet acceptance.  Based on results and benchmarks from this tool we can choose a primary magnet to pursue. 02 June 2011 Paul E. Reimer 13