MPGD (RD-51) Workshop Nikhef, Amsterdam, April 16-18 2008 1 Penning Effect on Gas Amplification Factor Ozkan SAHIN Uludag University Physics Department.

Slides:



Advertisements
Similar presentations
General Characteristics of Gas Detectors
Advertisements

Drew Rotunno Mentor: Dr. Itzik Ben-Itzhak, Bethany Joachim Bethany Joachim.
Radiation Detection ionization chambers (dosimeters, pulse chambers, particle track chambers) scintillation detectors semiconductor detectors photographic.
Program Degrad.1.0 Auger cascade model for electron thermalisation in gas mixtures produced by photons or particles in electric and magnetic fields S.F.Biagi.
GM COUNTER.
Recent R&D workon Micromegas detector Recent R&D work on Micromegas detector Liang Guan University of Science and Technology of China NanChang.
Drift velocity Adding polyatomic molecules (e.g. CH4 or CO2) to noble gases reduces electron instantaneous velocity; this cools electrons to a region where.
OPOLEOpole University Institute of Physics, Plasma Spectroscopy Group I am from.. 1.
Program Degrad.2.4 Auger cascade model for electron thermalisation in gas mixtures produced by photons or particles in electric and magnetic fields Uludag.
Maximilien Chefdeville NIKHEF, Amsterdam RD51, Amsterdam 17/04/2008
Principles of Radiation Detection
INTERACTION OF IONISING RADIATION WITH MATTER
Proportional Counters
Ionization. Measuring Ions A beam of charged particles will ionize gas. –Particle energy E –Chamber area A An applied field will cause ions and electrons.
Detectors. Measuring Ions  A beam of charged particles will ionize gas. Particle energy E Chamber area A  An applied field will cause ions and electrons.
Surface and volume production of negative ions in a low-pressure plasma E. Stoffels, W.W. Stoffels, V.M. Kroutilina*, H.-E. Wagner* and J. Meichsner*,
TRAINING COURSE ON RADIATION DOSIMETRY: Instrumentation 1 – Gas detectors / Part 1 Anthony WAKER, University of Ontario Instutute of Technology Wed. 21/11/2012,
Type of Material: Instrumentation Review
Zerguerras T. – IPNO – RDD – 14/06/2013 RD51 Collaboration Meeting July, Zaragoza 5-6th /12 New results on gas gain fluctuations in a Micromegas.
Measurement of gas gain fluctuations M. Chefdeville, LAPP, Annecy TPC Jamboree, Orsay, 12/05/2009.
Status of PNPI R&D for choice of the MUCH tracking base detector (this work is supported by INTAS) ■ Introduction ■ MICROMEGAS ■ GEM ■ MICROMEGAS+GEM ■
High Harmonic Generation in Gases Muhammed Sayrac Texas A&M University.
Simulation of the spark rate in a Micromegas detector with Geant4 Sébastien Procureur CEA-Saclay.
Tools for Nuclear & Particle Physics Experimental Background.
Hi Dave, The reason I do not like binary gas combinations of Argon and CO2 or Argon CH4 in proportional chambers is that they are not Penning Mixtures.
1 Ankit D. Mohapatra, Dr. Marcus Hohlmann Florida Institute of Technology, Melbourne, Florida Barry University, 8-9 March, 2013.
Systematic studies on the rate capability of MWPC operated in Xe/CO 2 D. Gonzalez-Diaz for the CBM-TRD group March, 2008.
Sunbeds and stars... Ionization, excitation and line spectra.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Stanford, Mar 21, 2005P. Colas - Micromegas TPC1 Results from a Micromegas TPC Cosmic Ray Test Berkeley-Orsay-Saclay Progress Report Reminder: the Berkeley-Orsay-
Geant4 Simulation of Neutrons interaction with GEM-foil and gas Gabriele Croci, Matteo Alfonsi, Serge Duarte Pinto, Leszek Ropelewski, Marco Villa (CERN)
1 TRD-prototype test at KEK-FTBL 11/29/07~12/6 Univ. of Tsukuba Hiroki Yokoyama The TRD prototype is borrowed from GSI group (thanks Anton).
Ionization Detectors Basic operation
2nd RD51 Collaboration Meeting, Paris, October PENNING TRANSFERS Ozkan SAHIN Uludag University Physics Department Bursa -Turkey 2nd RD51 Collaboration.
Experimental and Numerical studies on Bulk Micromegas SINP group in RD51 Applied Nuclear Physics Division Saha Institute of Nuclear Physics Kolkata, West.
Digital primary electron counting: W, Fano Factor, Polya vs Exponential M. Chefdeville, NIKHEF, Amsterdam RD51, Paris, October 2008.
April 22nd, 2004Nigel Lockyer / Young-Kee Kim1 Drift Chambers AMY experiment at e + e - TRISTAN collider CDF experiment B = 3 T B = 1.4 T.
Damping of the dust particle oscillations at very low neutral pressure M. Pustylnik, N. Ohno, S.Takamura, R. Smirnov.
Performance Studies of BULK Micromegas with Different Amplification Gaps Purba Bhattacharya 1, Sudeb Bhattacharya 1, Nayana Majumdar 1, Supratik Mukhopadhyay.
Snowmass, August, 2005P. Colas - InGrid1 M. Chefdeville a, P. Colas b, Y. Giomataris b, H. van der Graaf a, E.H.M.Heijne c, S.van der Putten a, C. Salm.
A. SarratTPC jamboree, Aachen, 14/03/07 1 Full Monte Carlo of a TPC equipped with Micromegas Antony Sarrat CEA Saclay, Dapnia Motivation Simulation content.
High rate studies of TRD at GSI (update) D. Gonzalez-Diaz, GSI
December 10, The Parallel Plate Chamber CERN Presentation Wout Kremers Detector R&D NIKHEF.
Xe-based detectors: recent work at Coimbra C.A.N.Conde, A.D. Stauffer, T.H.V.T.Dias, F.P.Santos, F.I.G.M.Borges, L.M.N.Távora, R.M.C. da Silva, J.Barata,
EUDET Meeting, Munich – October 18, Ongoing activities at Saclay David Attié D. Burke; P. Colas; E. Delagnes; A. Giganon; Y. Giomataris;
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Özkan ŞAHİN & Tadeusz KOWALSKI Uludağ University, Physics Department, Bursa – TURKEY Faculty of Physics and Applied Computer Science, AGH University of.
Construction and Characterization of a GEM G.Bencivenni, LNF-INFN The lesson is divided in two main parts: 1 - construction of a GEM detector (Marco Pistilli)
IEEE/NSS Oct 22, Electron Counting and Energy Resolution Study from X-ray conversion in Argon Mixtures with an InGrid-TimePix detector. D. ATTIÉ.
T. Zerguerras- RD51 WG Meeting- CERN - February Single-electron response and energy resolution of a Micromegas detector T. Zerguerras *, B.
Mesh transparancy and gas gain studies in micromegas detectors Fabian Kuger University of Würzburg, Germany July 06 th 2013 RD 51 Collaboration Meeting.
Özkan ŞAHİN Uludağ University Physics Department Bursa – TURKEY Survey of transfer rates using Zaragoza (Xe – TMA) and Krakow (Ar – CO 2 ) measurements.
Penning transfers: survey of available data, life-time of excited states, pressure dependence Ozkan SAHIN Uludag University Physics Department Bursa -TURKEY.
Update on THGEM project for RICH application Elena Rocco University of Eastern Piedmont & INFN Torino On behalf of an Alessandria-CERN-Freiburg-Liberec-
Gas detectors in a ZDC (at LHC) Edwin Norbeck and Yasar Onel University of Iowa For7 th CMS Heavy-Ion meeting at Delphi June 2003.
Endplate meeting – September 13, Gas issues for a Micromegas TPC for the Future Linear Collider David Attié D. Burke; P. Colas;
Geiger-Mueller Counters Darwin L. Boyd Kent State University School of Technology.
Development of a Single Ion Detector for Radiation Track Structure Studies F. Vasi, M. Casiraghi, R. Schulte, V. Bashkirov.
The digital TPC: the ultimate resolution P. Colas GridPix: integrated Timepix chips with a Micromegas mesh.
Influence of pulse parameters and cathodic cage size on plasma nitriding DEPARTMENT OF PHYSICS QUAID-I-AZAM UNIVERSITY ISLAMABAD, PAKISTAN Prof.
R&D Collaboration, CERN – September 10, Micromegas Performance and Ageing studies David Attié MPGD. Towards an R&D Collaboration,
Thorsten Lux. Charged particles X-ray (UV) Photons Cathode Anode Amplification Provides: xy position Energy (z position) e- CsI coating 2 Gas (Mixture)
Max Chefdeville, NIKHEF, Amsterdam
Activities on straw tube simulation
Elettra Sincrotrone Trieste
Secondary avalanches in gas mixtures
Improvements to magboltz and degrad data bases
Updates on the Micromegas + GEM prototype
Geiger-Mueller Tubes By: Daniel Hancock.
Presentation transcript:

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning Effect on Gas Amplification Factor Ozkan SAHIN Uludag University Physics Department Bursa-Turkey Micro-Pattern Gas Detectors (RD-51) Workshop Nikhef, Amsterdam, April

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Energy resolution is one of the fundamental counter parameters and it depends on both the number of produced ion pairs by an incident ionizing particle (W) and Fano factor (F) values It is expected that Penning mixtures would improve the detector energy resolution because of lower W and F values. Penning gas mixtures consist of a rare gas (in most cases Ar) and an admixture, usually molecular gases, which is present in a relatively low concentration. Introduction

MPGD (RD-51) Workshop Nikhef, Amsterdam, April The excitation energy of a metastable state of a rare gas should be higher than the ionization potential (I) of the admixture to enable an effcient transfer of energy stored in excited metastable state to ionization of the admixture. As a result of the energy transfer, the number of electron- ion pairs produced in the mixture increases, lowering thus the mean energy required to form an ion pair, and the Fano factor. We were interested mostly in low admixture concentrations because the possible Penning transfers are more efficient under such conditions. Introduction

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Excitation and ionization levels for Ar and iC 4 H 10 As the energies of the argon metastable states are 11.55, 13.0 and 14.0 eV only molecular gases having I less than eV can make a good Penning mixture with argon as the main gas. Isobutane (I =10.70 eV) added to argon forms one of the most effcient Penning mixtures. ion = 10.7 eV ion = 15.7 eV S - Level Exc. = eV Exc. 1 = 7.4 eV ARGON ISOBUTANE P- Level Exc. = 13.0 eV D - Level Exc. = 14.0 eV Exc. 2 = 9.7 eV Exc. 3 = 17 eV

MPGD (RD-51) Workshop Nikhef, Amsterdam, April A schematic view of the experimental setup and proportional counter * I. K. Bronic, B. Grosswendt NIM B 142 (1998) The inner diameter of the stainless-steel counter is 5 cm, the length is 15 cm, and it was placed in a copper shield, 8 cm in diameter. The anode was a stainless-steel wire of 25  m in diameter. Gas gain measurement The measurements of the gas gains were made in argon based mixtures in a proportional counter at different total gas pressures *.

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Measurements of the mean gas gains in argon-isobutane mixtures performed at total gas pressures of 30, 60 and 90 kPa. Gas gain measurement

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Measured and calculated (without Penning effect) gas gains Magboltz calculation Experiment

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Isobutane ionisation Argon ionisation Isobutane exc. Argon S level exc. Argon P level exc. Argon D level exc. Excitation and ionization frequencies of Ar and iC 4 H 10

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Gain including photon term Photon term Main gain Calculation The probabilities of Penning transfers have been calculated by fitting experimental data using Minuit in Root. The first Townsend coefficients including Penning transfers

MPGD (RD-51) Workshop Nikhef, Amsterdam, April // ar-96.7-iso-3.3 at 30kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-95-iso-5 at 30kPa NO. NAME VALUE ERROR 1 prob e e-05 // photon term 2 prob e e-03 // including all transfers // ar-90-iso-10 at 30kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-80-iso-20 at 30kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-70-iso-30 at 30kPa NO. NAME VALUE ERROR 1 prob e e-03 // including all transfers ~29.5% ~18.9% ~25.8% ~18.8% ~14.6% Transfer probabilities

MPGD (RD-51) Workshop Nikhef, Amsterdam, April // ar-97.5-iso-2.5 at 60kPa NO. NAME VALUE ERROR 1 prob e e-05 // photon term 2 prob e e-03 // including all transfers // ar-95-iso-5 at 60kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-90-iso-10 at 60kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-80-iso-20 at 60kPa NO. NAME VALUE ERROR 1 prob e e-03 // including all transfers ~29.4% ~25.4% ~24.0% ~26.3% Transfer probabilities

MPGD (RD-51) Workshop Nikhef, Amsterdam, April // ar-97.8-iso-2.2 at 90kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-96.7-iso-3.3 at 90kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-93.4-iso-6.6 at 90kPa NO. NAME VALUE ERROR 1 prob e e-06 // photon term 2 prob e e-03 // including all transfers // ar-90-iso-10 at 90kPa NO. NAME VALUE ERROR 1 prob e e-03 // including all transfers // ar-80-iso-20 at 90kPa NO. NAME VALUE ERROR 1 prob e e-03 // including all transfers ~37.7% ~38.4% ~42.5% ~45.8% ~47.3% Transfer probabilities

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Townsend coefficient versus E field (with and without Penning effect) Penning transfers start

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Variation of Penning impact on Alpha with E field 30 kPa 90 kPa 60 kPa Increasing pressure increase Penning transfer probabilities

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Measured and calculated (with Penning effect) gas gains at 30 kPa Magboltz calculation Our calculation Experiment transfers ~29.5% photon term = e-04 transfers ~18.9% photon term = e-04 transfers ~25.8% photon term = e-05 transfers ~18.8% photon term = e-05

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning impact on gas gains at 30 kPa Gain

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Measured and calculated (with Penning effect) gas gains at 60 kPa Magboltz calculation Our calculation Experiment transfers ~29.4% photon term = e-04 transfers ~24.0% photon term = e-05 transfers ~25.4% photon term = e-05 transfers ~26.3%

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning impact on gas gains at 60 kPa Gain

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Measured and calculated (with Penning effect) gas gains at 90 kPa Magboltz calculation Our calculation Experiment transfers ~37.7% photon term = e-05 transfers ~42.5% photon term = e-06 transfers ~38.4% photon term = e-05 transfers ~47.3%

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Penning impact on gas gains at 90 kPa Gain

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Variation of Penning impact on gas gains with pressure Gain

MPGD (RD-51) Workshop Nikhef, Amsterdam, April Conclusion  Penning transfers on first Townsend coefficients and gas gain factors are important at lower admixture concentrations.  Systematics calculation on Penning transfer probabilities are going on.  Calculations will be performed for other Penning mixtures..