For the past several years, one of the primary focuses of our research group has been the development of novel ion-exchange systems for the purpose of.

Slides:



Advertisements
Similar presentations
OFFLINE COMPOSITION MEASURING SENSORS
Advertisements

EDTA Titrations. Chelation in Biochemistry Chelating ligands can form complex ions with metals through multiple ligands. This is important in many areas,
Ion Sources Some characteristics of ion sources (especially in high precision work): It should have high efficiency in generating ions of the element of.
Capillary Electrophoresis and Capillary Electrochromatography
Protein Purification Molecular weight Charge Solubility Affinity.
Chromatography for Protein purification 1
ACADs (08-006) Covered Keywords analytical balance, conductivity bridge with flow cell, inductively coupled plasma analyzer, in-line sodium monitor, ion.
1 Atomic Absorption Spectroscopy Atomic Emission Spectroscopy Lecture 18.
Chapter 10 ATOMIC EMISSION SPECTROMETRY
Atomic Emission Spectroscopy
Inductively Coupled Plasma Mass Spectrometry or ICP-MS
Ion-Pair Chromatography In addition to the aqueous buffer and an organic solvent that is typical for reversed-phase, the mobile phase contains a counter.
Electrolysis Amy Jewel, Rob Larkin and Todd Haurin “Water will be the coal of the future.” -Jules Verne, 1874.
Atomic Emission Spectroscopy. Chem Introduction Atomic absorption is the absorption of light by free atoms. An atomic absorption spectrophotometer.
1 Atomic Absorption Spectroscopy. 2 Atomic Transitions: Excitation and Emission.
Molecular Fluorescence Spectroscopy
Atomic Emission Spectroscopy
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Mass Spectroscopy Mass Spectrometry ä Most useful tool for molecular structure determination if you can get it into gas phase ä Molecular weight of.
Atoms Smallest electrically neutral particle of an element that retains the properties of that element.
Atomic Emission - AES M* → M + hn Thermal excitation M → M*
Chapter 2 Chemical Foundations.
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Chapter 8 An Introduction to Optical Atomic Spectroscopy
Redox.  Redox involves two simultaneous reactions ◦ An oxidation and a reduction  Oxidation involves a loss of electrons  Reduction involves a gain.
B IOCHEMICAL INSTRUMENTAL ANALYSIS -11 Dr. Maha Al-Sedik.
Physical Science Applications in Agriculture Unit Physical Science Systems.
Atomic Emission Spectroscopy
Atomic Emission Spectrometry
Content page Introduction of Electrolysis Properties of sea water Compositions of sea water Electrode Electrolysis of sea water Chlorine gas Hydrogen.
Mass spectrometry Ions are analyzed on the basis of their m/z Chlorine has 2 isotopes, 35 Cl and 37 Cl, in the approximate ratio of 3 :1. Electrons are.
6- PRENTICE HALL ©2007 Pearson Education, Inc. Upper Saddle River, NJ CRIMINALISTICS An Introduction to Forensic Science, 9/E By Richard Saferstein.
Ion exchange chromatography
to Optical Atomic Spectroscopy
Proteins I BCH 302 [practical].
Adv. Inst. Techs.  flame emission (eg flame photometer) known as low temperature emission ( K) ◦ first form of spectroscopy ◦ used in commercial.
For the past several years, one of the primary focuses of our research group has been the development of novel ion-exchange systems for the purpose of.
Blotting techniques are based Complementarity and Hybridization Blotting techniques are used to answer questions like oHow do we find genes of interest.
Accuracy of the Debye-Hückel limiting law Example: The mean activity coefficient in a mol kg -1 MnCl 2 (aq) solution is 0.47 at 25 o C. What is the.
Electrochemical cell. Parts of a Voltaic Cell The electrochemical cell is actually composed to two half cells. Each half cell consists of one conducting.
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
Chemical Basis of Life. Matter – Anything that occupies space and has mass Mass – The amount of matter in an object (kg) Weight – Gravitational force.
Mass spectrometry (Test) Mass spectrometry (MS) is an analytical technique that measures masses of particles and for determining the elemental composition.
Electrochemistry.
Atomic Fluorescence Spectroscopy. Background l First significant research by Wineforder and Vickers in 1964 as an analytical technique l Used for element.
C3 General Revision Aaaahhh!!!. The Periodic Table of the Elements. The Periodic Table lists the chemical elements in increasing atomic number. The Periodic.
CHEMISTRY. Composition of Matter Matter - Everything in universe is composed of matter Matter: anything that occupies space or has mass Mass – quantity.
10.3 Half-reactions and electrodes
Elements Pure substances that cannot be broken down chemically into simpler kinds of matter More than 100 elements (92 naturally occurring)
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
Chemistry 4631 Instrumental Analysis Lecture 18 Chem 4631.
Chapter 18 Electrochemistry Lesson 1. Electrochemistry 18.1Balancing Oxidation–Reduction Reactions 18.2 Galvanic Cells 18.3 Standard Reduction Potentials.
Chapter 29 Mass Spectrometry. 29 A Principles of mass spectrometry In the mass spectrometer, analyte molecules are converted to ions by applying energy.
CHEMISTRY REVIEW. Composition of Matter Matter - Everything in universe is composed of matter Matter is anything that occupies space or has mass Mass.
Environmental Systems
WESTERN BLOT Reagents: 2x SDS buffer Running buffer Transfer buffer
Agarose Gel Electrophoresis
ELECTRO-ANALYTICAL TECHNIQUES   POTENTIOMETRIC TECHNIQUES Principle Electrochemical techniques/ Electrochemical methods are generally used for determination.
Flame Emission Spectrometry
Chapter 6 INORGANIC ANALYSIS
Mass Spectroscopy. Mass Spectroscopy Mass Spectrometry Most useful tool for molecular structure determination if you can get it into gas phase Molecular.
Instrumental Chemistry
Advanced Higher Chemistry Unit 2(e)
Exploring a Combinatorial Approach
Agarose Gel Electrophoresis
Electrogravimetry in electrogravimetry the product is deposited quantitatively on an electrode by an electrolytic reaction and the amount of the product.
Capillary Electrophoresis and Capillary Electrochromatography
Chapter 2 The Chemistry of Life
M.Prasad Naidu MSc Medical Biochemistry, Ph.D,.
Agarose Gel Electrophoresis
Presentation transcript:

For the past several years, one of the primary focuses of our research group has been the development of novel ion-exchange systems for the purpose of metal remediation from aqueous systems. Expanding on hints from Mother Nature, we chose to explore the metal chelation abilities of proteins and, in particular, their constituent amino acids. In order to simplify these ion-exchange systems, short-chain homopolymers consisting of repeating monomers of a specified amino acid residue have been used. These systems exhibit many of the characteristics for an ideal ion-exchanger – strong binding; fast, efficient release and structural stability. These biologically-based systems also have the added benefit of being environmentally friendly, unlike many traditional exchange systems which require harsh extraction agents. Developing Fluorescence- based Sensors Questions? Shelly. M+M+ M+M+ M+M+ M+M+ M+M+ M+M+ M+M+ Support The Bonded-Phase Ion-Exchange System Visit us! On the web: In the Lab: Welch and Metallomic Studies with PAGE-LA-ICPMS Questions? Isaac. Questions? Ram. Questions? Haley. ETV-ICP-MS for Isobars and Isotopes Questions? Adam. Creating Chemical-free Remediation Systems Column 3-electrode potentiostat Clean Effluent Stream Metal Recovery Stream valve Reference Electrode E applied Auxiliary Electrode An electrical potential is used to change the binding characteristics of the column. M n+ Oxidation Reduction M n+ Free metal can be bound and released by exposing the ligand to successive reduction and oxidation cycles. Flow Working Electrodes Counter Electrodes Scale up of the electrochemical reactor to practical size requires consideration of materials, geometry, operating conditions, and overall cost. First Vaporization Stage Second Vaporization Stage One problem with ICP-MS is elements of the same nominal mass (isobaric interference). ETV can be used to separate some problematic elements based on their differing volatilities. Rb and Sr can be separated to remove the isobar at mass 87. The time of flight design is able to offer excellent isotope ratio precision as a result of simultaneous ion extraction from the plasma. However, difficulties have been encountered with ratio accuracy. Factors that cause this and possible fixes are actively being researched. ICP-MS is the cutting edge technology for atomic spectrometry. It can offer part per trillion detection limits, over 5 orders of magnitude of linear response, and works for almost all elements in the periodic table. It uses an inductively coupled plasma (~8,000 K) as the ionization source. Our ICP-MS uses a time of flight system for mass analysis. Though many labs rely on solution nebulization for sample introduction, this is not always the best technique. It can be problematic for some matrices (e.g. salty solutions, organic solutions, and solids or slurries). An alternative is electrothermal vaporization (ETV). This uses a carbon tube to vaporize the sample before introduction to the ICP-MS. Vaporization temperatures of up to 3,000 o C can be achieved in a controlled manner. It can handle a wide variety of sample types, and generally has higher sample introduction efficiency than nebulizers. To ICP-MS Sample Internal Standards for ICP- TOF-MS 238 U/(IS) ΔIP %RSD r = Δmass %RSD r = U/(IS) A B Graphical Illustration of %RSD By definition, a small change in the ratio between two elements as a condition changes, is indicative of a good analyte-IS pair. The %RSD of these ratios is used as a quantitative measure of internal standard compatibility. Each point on the scatter plots illustrated in the example plot above represents a ratio of 238 U and one of approximately 100 IS considered. Analyte-to-IS mass separation typically offered the strongest and most consistent relationship to %RSD for all conditions. Determining the Relationship Between %RSD and Chemical Properties Objective: Determine what metals are associated with what proteins, and how strongly they are bound. First, proteins are separated in their native (metal-containing) state by using native PAGE. This separates the proteins based on molecular weight. We push the protein towards metal complexation by using a metal-loaded buffer during separation (Le Chatelier’s Principle). Cathode - Anode + M+M+ M+M+ ProteinA M+M+ Blotting Membranes Gel Next, the separated proteins/metals are transferred to functionalized quartz membranes through a process known as electroblotting. The metalloproteins are attracted to the anode, while the positively charged free metal ions are attracted to the cathode. The membranes are ablated with a laser and the metals are detected by ICPMS. FdFd Fluorescence resonance energy transfer (FRET) can be used to determine various characteristics of metal binding. FRET involves the transfer of energy between a fluorescent donor and an acceptor molecule. The efficiency of the energy transfer is dependent on the distance between the molecules, which can be related to their spectroscopic properties. This concept can be utilized for a metal ion sensor. FaFa M n+ A FRET pair (a donor, F d, and an acceptor, F a ) lie on opposite ends of a peptide chain. A metal ion (M n+ ) then comes into contact with the peptide chain which has specific binding characteristics. FdFd FaFa M n+ hvhv FRET hvhv When the metal binds, the peptide will wrap around the metal, decreasing the two fluorophores’ distance and causing the likelihood of FRET to increase.