Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.

Slides:



Advertisements
Similar presentations
Supplementary Training Modules on Good Manufacturing Practices
Advertisements

Quality is a Lousy Idea-
Analytical Method Development and Validation
Instrumental Analysis
Calibration methods Chemistry 243.
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Accreditation & Validation
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
Summary 1 l The Analytical Problem l Data Handling.
Data Handling l Classification of Errors v Systematic v Random.
Supplementary Training Modules on Good Manufacturing Practice
Types of experimental error
Technical requirements  Sampling  Analysis  Reporting of the results.
Validation of analytical methods
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Kyiv, TRAINING WORKSHOP ON PHARMACEUTICAL QUALITY, GOOD MANUFACTURING PRACTICE & BIOEQUIVALENCE Validation of Analytical Methods Used For Bioequivalence.
CALIBRATION METHODS.
Chemometrics Method comparison
Validation of Analytical Method
Dr. Michael Scheutwinkel
CH915: Elemental Analysis
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Quality WHAT IS QUALITY
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Bias and Errors. Some Terms Used to Describe Analytical Methods Accuracy Precision LOD RDL LOQ Selectivity Sensitivity Linearity Ruggedness.
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Koch, M.: Control Charts© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training.
Quality Assurance How do you know your results are correct? How confident are you?
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Data Analysis: Quantitative Statements about Instrument and Method Performance.
1 Exercise 7: Accuracy and precision. 2 Origin of the error : Accuracy and precision Systematic (not random) –bias –impossible to be corrected  accuracy.
Chimiometrie 2009 Proposed model for Challenge2009 Patrícia Valderrama
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Introduction The importance of method validation
MPA requirements on validation of bioanalytical methods The analytical method should be validated before analysing of specimens from GLP and GCP studies.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Verification of precision and bias
Limit of detection, limit of quantification and limit of blank Elvar Theodorsson.
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning.
Estimating measurement uncertainty
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
CENTRO DE METROLOGIA QUIMICA. DEVELOPMENT OF CERTIFIED REFERENCE MATERIALS (CRMs) IN Intec.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
 Routine viral diagnostics: indirect and direct detection of viruses. ◦ Indirect detection: serological tests; ◦ Direct detection:  Viral antigens;
Copyright © 2015, TestAmerica Laboratories, Inc. All rights reserved. 1 EPAs New MDL Procedure What it Means, Why it Works, and How to Comply Richard Burrows.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Chapter 5 Quality Assurance and
EQUIPMENT and METHOD VALIDATION
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Method Validation of VINDTA 3C (TA/DIC) Marine Scotland Science (MSS) Experience and Concerns Pamela Walsham.
Quality is a Lousy Idea-
World Health Organization
Metals Subgroup Agenda
Quality is a Lousy Idea-
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
What it Means, Why it Works, and How to Comply
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
Режа: 1. Метрология тушунчаси 2. Валидация
Calculating Uncertainties Using Data from precision & bias experiments
ANALYTICAL METHOD VALIDATION
World Health Organization
DICLOFENAC Validation according to requirements
Presentation transcript:

Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology Institute SLAB 2015/11/10, BMICH VER 6

Industrial Technology Institute 2 Introduction An analytical method is the series of procedures from receipt of a sample to the production of the final report. Validation is the process of verifying that a method is fit for purpose.

Industrial Technology Institute 3 Basic Concepts in Method Validation Specificity Analyte Stability Analytical Range Calibration Range Recovery (Accuracy) Precision Limit of Detection (LOD) Limit of Quantification (LOQ) Measurement uncertainty

Industrial Technology Institute 4 Specificity Shows that the detected signal is due to the analyte, not another compounds/ s. Use matrix blanks, reagent blanks for conformation of specificity

5 Example: Confirmation of Identity

Industrial Technology Institute 6 Analyte Stability Analyte stability during sample storage, analyte stability in sample processing, analyte stability in sample extract should be studied.

Industrial Technology Institute 7 Analytical Range Range of the analyte that can be analysed with the proposed selected method.

Industrial Technology Institute 8 Calibration Range If a linear calibration is used, the range in which the response for the anayte shows a linear correlation with the analyte’s concentration should be determined. This is known as linear dynamic range.

Industrial Technology Institute 9 Linear Dynamic Range

Industrial Technology Institute 10 Recovery % Recover of the anlalyte on extraction, clean-up, derivatization and measurement. Can be done with -Certified Reference Material (CRM,s) -Standard Reference materials (SRM,s) -Interlaboratory comparisons -Spiking 20 %, 50 % and 80 %)

Industrial Technology Institute 11 Accuracy (Trueness) How close the result to the expected (assigned) value

12 Example: Accuracy SampleBlank value (mg/L) RM value (mg/L) Mean value RM assigned value: 1.22 ± 0.08 mg/L; Laboratory value for RM: mg/L Mean laboratory Value from RM value certificate mg/L 1.22 mg/L Bias value

13 Accuracy versus Precision Accuracy (Trueness) Precision Accuracy & Precision

Industrial Technology Institute 14 Precision Is measured as “repeatability “ or reproducibility Repeatability Measurement is repeated with a minimum of variations (same person, same laboratory, same equipment, over a short period of time. Reproducibility Measurement is repeated with as much variation as possible. (Different analyst, different laboratory, different equipment, over a long period of time).

Industrial Technology Institute 15 Limit of Detection (LOD) Point where the variability of the measurement is such that it is impossible to distinguish between random fluctuation in the value measured and actual signal. –LOD = Y B + 3XS B Y B = Mean value measured from the blank S B = Standard Deviation of the value measured from the blank

16 Replicate (n)Instrument response Calculated Concentration (ppb) Mean StdDev Times StdDev Detection Limit TBT in Biota Limit of Detection

Industrial Technology Institute 17 Limit of Quantification (LOQ) Point where the measured value could be quantified reliably LOQ = Y B + 10XS B Y B = Mean value measured from the blank S B = Standard Deviation of the value measured from the blank

18 Example: TBT in Biota Replicate (n)Instrument response Calculated Concentration (ppb) Mean StdDev Times StdDev Detection Limit Limit of Quantitation Blk + 5s Blk + 6s Blk + 10s Limit of Quantification (LOQ)

19 Sensitivity- Cadmium Analysis by AAS Cd Concentration (mg/L) Absorbance slope = ± intercept = ± r-square = X X x x x x Sensitivity

20 Measurement Uncertainty Uncertainty estimates should take account of: Overall long-term precision Bias and its uncertainty, including the statistical uncertainty involved in the bias measurements, and the reference material or method uncertainty Calibration uncertainties Any significant effects operating in addition to those listed above

21 Test Method Verification Any standard method shall be verified before being used in the laboratory Verify the Recovery Accuracy Precision ( Repeatability and Reproducibility) LOD and LOQ