Optimizing Radiochemical Methods at SRS (Ni-63, I-129, Actinides) Sherrod L. Maxwell, III Westinghouse Savannah River Company.

Slides:



Advertisements
Similar presentations
Ra in Water using MnO2 Resin: New Developments
Advertisements

O AK R IDGE N ATIONAL L ABORATORY U. S. D EPARTMENT OF E NERGY 1 Using Eichrom Resins to Simplify the Analyses for Gallium Content and Atom Percent Fission.
Analysis of Actinide Elements from Large Environmental Samples
Chromatography Components stationary phase (eg., solid matrix) mobile phase (eg., solvent) solute Solutes which interact differently with the stationary.
A Grace company Avoiding Matrix Interferences in Ion Chromatography Using Solid Phase Extraction Alltech Associates, Inc. Brandstraat 12, 9160 Lokeren.
Anomalous Behavior of TEVA Resin Prepacked Columns: A Technical Update Anil Thakkar November 1st 2004 Cincinnati, OH.
A NALYTICAL S EPARATIONS G ROUP Megan Bennett, Ashlee Crable, Sherry Faye, Narek Gharibyan, Julie Gostic, and Chris Klug Subgroup Leader: Ralf Sudowe.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
Measurements of Ra Isotopes via MnO2 Resin
Rapid Actinide Analysis for Large Soil Samples
New Applications of Rapid Column Extraction for Methods at SRS Sherrod L. Maxwell III Savannah River Site.
Analysis of Actinide Elements from Large Samples Henrieta Dulaiova Guebuem Kim Bill Burnett Florida State University and E. Philip Horwitz PG Research.
New Extraction Methods for Urine and Fecal Samples
D. P. DiPrete, C. C. DiPrete, and R. A. Sigg
Technical Updates on UTEVA, TEVA and TRU Resins
Optimizing Radiochemical Methods at SRS
© Copyright, West Valley Nuclear Services Company, LLC (2004) The views expressed by the authors are their own and do not necessarily represent the views.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Gel filtration Chromatography
Rapid Separation Methods for Bioassay Samples S. L. Maxwell, III and D. J. Fauth Westinghouse Savannah River Site.
MnO 2 Resin: Concentration of Radium Isotopes Deok-Soo Moon Bill Burnett Department of Oceanography Florida State University Tallahassee, Florida.
Buffers 4/13/2011. Definitions Weak Acids: all proton donors that are in equilibrium Conjugate Bases: the ions that are left over after a weak acid loses.
The Determination of 226 Ra in Water Samples Anil H. Thakkar Eichrom Technologies, Inc. eichrom TECHNOLOGIES INC.
The Determination Of 226 Ra In Soil Samples Lawrence D. Morris General Engineering Laboratories, Inc. Anil H. Thakkar Eichrom Technologies, Inc.
The Determination of 224 Ra, 226 Ra, & 228 Ra in Water Samples Michael Fern Eichrom Technologies, Inc.
Application of a beryllium specific resin at the Y-12 National Security Complex YGG Darrin K. Mann, D.H. “Bo” Bowman, Thomas J. Oatts, and Vicki.
Determination of Sr-89/Sr-90 in primary cooling water
Analysis of Actinide Elements from Large Samples Henrieta Dulaiova Guebuem Kim Bill Burnett Florida State University and E. Philip Horwitz PG Research.
Radioactive Materials Analytical Laboratory Eichrom Technologies Inc. User Group Meeting May 2001 J.M. Giaquinto, L.D. Bible, D.C. Glasgow, J.M. Keller.
Actinide Analysis from Large- Volume Seawater Samples Bill Burnett & Guebuem Kim Department of Oceanography Florida State University and Phil Horwitz PG.
Rapid Actinide Analysis for Large Soil Samples-Update Sherrod L. Maxwell, III Westinghouse Savannah River Company.
MnO 2 Resin: Concentration of Radium Isotopes Deok-Soo Moon Bill Burnett Department of Oceanography Florida State University Tallahassee, Florida.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
00J ppt Rapid Extraction Methods for the Process Laboratory S. L. Maxwell, III V. D. Jones S. T. Nichols J. Satkowski M. A. Bernard Westinghouse.
Elution and Mounting Techniques for Americium using Eichrom TRU Resin Mitch Abbate Radiochemistry Technical Director Severn Trent Services St. Louis May.
Ulrika Nygren, June 2002 Determination of actinides in emergency preparedness using Diphonix or Actinide resin in combination with gamma spectrometry Ulrika.
General Engineering Laboratories Use of Eichrom Resins for Bioassay Pa-231 Bob Timm - GEL Tim Chandler - GEL Bill Burnett - FSU Mike Schultz - PerkinElmer.
Developments in Environmental Radiochemistry* Environmental Radioactivity Measurement Facility Department of Oceanography Florida State University Tallahassee,
Distribution of radionuclides in soils in surroundings of Bratislava, capital of the Slovak Republic. II. Man-made radionuclides Mátel Ľ., Rosskopfová.
ICP MAKING STANDARDS. NUMBER OF STANDARDS Determine the number of standards necessary for your measurements (Blank, 100ppb, 500ppb, 1000ppb, etc)
The Determination of 226Ra in Water Samples
Working Through Mistakes, Miscues, and Mishaps in Actinide Separations Shane Knockemus US EPA / NAREL Montgomery, AL May 4, 2004.
Updates from Eichrom’s Tech Support Lab Anil Thakkar May 4 th 2004 Charleston, SC.
New Extraction Methods for Actinides in Urine at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Recent Improvements in Rapid Column Separation Methods at SRS S. L. Maxwell, III, D. J. Fauth, R. C. Henderson, J. J. Smiley, S. R. Johnson Westinghouse.
Th, Pu & U Separation Using TEVA and UTEVA Resin
Recent Improvements in Rapid Column Separation Methods at SRS
EIChroM I N D U S T R I E S, I N C. Introduction of Eichrom TEVA Disc: Tc-99 Analysis Anil H. Thakkar, Lawrence Jassin, Michael Fern Eichrom Industries,
New Fecal Method for Plutonium and Americium at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
Optimizing Peak Separation for Simultaneous Pu and U Measurements Shane Knockemus US EPA / NAREL May 3, 2005.
 Extraction of OM  Rock-Eval (Pyrolysis)  Elemental analysis  GC, HPLC & MS  SIRMS.
Rapid actinide measurements in environmental samples Dr Phil Warwick Geosciences Advisory Unit Southampton Oceanography Centre.
On-line Actinide Quantification with Extractive Scintillating Resins Timothy A. DeVol, James E. Roane, Lara D. Hughes Clemson University Eichrom Users’
New Fecal Method for Plutonium and Americium at SRS Sherrod L. Maxwell III and David Fauth Savannah River Site.
One-Column Separation and Analysis of Isotopic Am and Pu in Soil Samples Nidal M. Jadalla, Eberline Services, Albuquerque, NM Anil Thakkar, Eichrom Technologies,
Pyrosulfate fusion vs. TEVA / TRU forcing the issue Shane Knockemus U.S. EPA / NAREL Montgomery, AL November 11, 2002.
MnO 2 Resin and Automated Measurements of Ra Isotopes Bill Burnett Dept. Oceanography Florida State University.
Making dilutions A lot of the time in chemistry, scientists need to make a dilution from a stock solution to use in reactions M 1 V 1 = M 2 V 2 Make sure.
An Improved Method for Determination of Ra-228 * Jamie Christoff & Bill Burnett Department of Oceanography Florida State University “The Double-Pass Approach”
Anil H.Thakkar Eichrom Industries, Inc.. Darien, IL
The Determination of 226Ra in Water Samples
Strontium Extraction from Urine Samples
Solid Phase Extraction Optimization Experiment
Ra in Water using MnO2 Resin: Update
Technical Updates on TRU and TEVA Resins
Technetium-99 in Urine Tabitha Liebrecht & Buzz Vickery
Rapid Emergency Methods for Actinides and Sr-89/90
Eichrom Resin Columns: A New breakthrough
remove 167 mL aliquot for Sr-90 spike with 1 mg stable Sr carrier
National Air and Radiation Environmental Lab
Presentation transcript:

Optimizing Radiochemical Methods at SRS (Ni-63, I-129, Actinides) Sherrod L. Maxwell, III Westinghouse Savannah River Company

Recent Improvements Ni-63 in water method –increase Ni Resin capacity for gravimetric recovery I-129 in water method –adapt to vacuum box for rapid flow Actinides –TEVA+ TRU for waters, air filters, vegetation, soils Pu+Np in same fraction Less Th and Po-210 problems New soil method –Alpha resolution: Am/Cm and Th w/o ashing

Ni-63 in Water Ni resin columns limited in Ni capacity (3 mg ) –Need more Ni capacity for reliable gravimetric carrier recovery –Ni carrier limited to ICP levels –Ni-dimethylglyoxime complex bleeds off resin Adjust pH to 10 instead of 8-9 for higher retention Added prefilter cartridge to catch bleed-off Can use up to ~10 mg Ni carrier Used 8 mg Ni carrier: mg NiO

Ni-63 in Water Evaporation Sample loading

Load complete, Ni complex color at bottom of column During column rising: Ni complex bleed-off caught on prefilter cartridge

Ni column stripping Evaporate/ash NiO

Ni Cartridge Option Ni Resin cartridges instead of columns + disposable reservoirs

10 mg Ni carrier

Ni-63 Method Data LCS SMP-1 SMP-2 DUP SMP-3 MS SMP-4 SMP-5 MS SMP-6 SMP-7 MS BLK 300 mL groundwater samples Ni-63 Spk= 50 pCi Ni carrier = mg NiO NiO Recovery 99.9 % 98.9 % 97.9 % 101.9% 99.9 % 97.4 % 98.9 % Ni-63 Spk Recovery 92.0 % 97.2 % 89.5% 90.4 % avg = 92.3 % (3.4% rsd)

I-129 Method 1 pCi/L MDA; 1.5 liter samples pH adjust /reduce to iodide ion with NaHSO3 Anion exchange-1X8, mesh Flow rate ~25 mL/min Vacuum box loading with inner liner –~ 1 to 1.5 hour loading –speed & ability to deal with slow samples Resin to petri dish Low energy x-ray

I-129 Method Data Typical batch of 1.5L samples I-129 Standard AddedMeasured LCS =16.7 pCi/L15.5 pCi/L MS = 16.7 pCi/L16.0 pCi/L % Recovery LCS93% % Recovery MS96%

TEVA-TRU Separations (Pu, Np, Am, Cm, U)

Alpha Resolution Improvements Resolve™ filters-Eichrom –reduced FWHM, from about keV to about keV –eliminated a lot of filter problems and rework from “bad” lots of filters from other suppliers Strong HCl causes more extractant bleed-off –added small, 3M nitric rinse after strong HCL Th removal and before Pu strip from TEVA – added small, 3M nitric rinse after strong HCL Th removal and before U strip from TRU Resin What about Am-Cm and Th strong HCl solutions containing organic? –Had tried Am/Cm micro-precipitation from 4M HCL with extra HF and no ashing but too often had poor resolution/rework

Alpha Resolution Improvements Am/Cm and Th HCL strip solutions contain organic bleed- off that can affect alpha peak resolution Ashing takes time –Th samples (3-4 hrs) and Am/Cm samples (2-3 hrs) –Prolongs sample preparation Solution: –Use prefilter cartridges when stripping Th or Am/Cm –No ashing required –Dilute Am/Cm to 30 mL with water + 3mL con HF –Dilute Th to 45 mL + 5 mL con HF

Resolution with Filters from “Bad” Lot

Resolution with RESOLVE ™ Filters

Resolve Filters-No Ashing

Summary Ni Resin – Ni capacity expanded using prefilter resin –gravimetric carrier I-129 method-vacuum box –reduced loading times TEVA-TRU Separations for all matrices –Eliminated cerium fluoride filter problems –Am/Cm and Th alpha resolution-no ashing/prefilter cartridge