Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery Ernesto Gomez PhD, Yasha Karant PhD, Veysi.
QUESTION 1: name the a) study and b) orientation Answers: A) This is a CT scan of the head B) This is in the coronal plane * The dark areas are the paranasal.
The importance of MRI, a few numbers  MRI units worldwide in 2003  75 millions scans per year performed  Constant need for over 1000 MRI technologists.
Principles of MRI. Some terms: –Nuclear Magnetic Resonance (NMR) quantum property of protons energy absorbed when precession frequency matches radio frequency.
Equipment Magnetic resonance imaging (MRI) scan requires the use of a very strong magnetic field. Unlike other devices used in radiology, MR imaging.
Surface Reconstruction from 3D Volume Data. Problem Definition Construct polyhedral surfaces from regularly-sampled 3D digital volumes.
Arizona’s First University. Feasibility of Image-Guided SRS for Trigeminal Neuralgia with Novalis.
A Novel Approach To Spectral MRI Tiffany A. Fetzner* Advisor Joseph P. Hornak Rochester Institute of Technology May 8, 1998.
Magnetic Field Studies Dan Karmgard for the HCAL RBX Group.
/mhj In Vivo Quantitative Assessment of Carotid Plaque component with multi-contrast MRI Jannie Wijnen 22 may 2003 using clustering algorithms, implemented.
Psy 8960, Fall ‘06 Gradients and Fields1 Gradients and fields Static magnetic field Gradients –Effect of simultaneous gradients Excitation and slice selection.
MSc project Janneke Ansems Intensity and Feature Based 3D Rigid Registration of Pre- and Intra-Operative MR Brain Scans Committee: Prof. dr.
Haskins fMRI Workshop Part I: Data Acquisition & Preprocessing.
MAGENETIC RESONANCE IMAGINING T2, T5, T7.
CNS 2 IMAGING OF BRAIN ( block). IMAGING MODALITIES PLANE X-RAY CTSCAN MRI ANDIOGRAPHY ULTRASOUND RADIOISOTOPES STUDY.
What Are They? Computed Tomography Angiography (CTA)
Principles of MRI Physics and Engineering
Fundamentals of Image Interpretation Joseph Castillo B.Sc, M.Sc (MRI)
Application of Cone Beam Computed Tomography Imaging to Dental and Maxillofacial Practice. ABSTRACT ID NO: IRIA-1162.
vertebrae.
Optimization of Gamma Knife Radiosurgery Michael Ferris University of Wisconsin, Computer Sciences David Shepard University of Maryland School of Medicine.
Performance Analysis of an Optoelectronic Localization System for Monitoring Brain Lesioning with Proton Beams Fadi Shihadeh (1), Reinhard Schulte (2),
Software Development For Correction of Gradient- Nonlinearity Distortions in MR Images T.S. Lee, K.E. Schubert Computer Science CSUSB R.W. Schulte Radiation.
MRI Correction In 5-7 Minutes Dr. Keith Evan Schubert.
MRI DRAFT Principles of MRI ► Sectional Anatomy ► Provides anatomic and physiologic info ► Non- invasive ► No radiation  Magnetic fields and.
INTRODUCTION In studying the relation between the electric and the magnetic field produced by the current sources of different forms there is a challenging.
Segmentation of Subcortical Sructures in MR Images VPA.
By Lisa Rosenberg.  Discovered in 1950 by Lars Leksell and Börje Larsson  Noninvasive procedure  Uses precise radiation to attack cells  Similar to.
Ron Cohen Ramy Ben-Aroya Ben-Gurion University ICBV 2009 Final Project.
Introduction Magnetic resonance (MR) imaging is recognised as offering potential benefits in the delineation of target volumes for radiotherapy (RT). For.
ExactEstimate 300 msec.
Ch. 3: Geometric Camera Calibration
Pelvic MR scans for radiotherapy planning: Correction of system- and patient-induced distortions Simon J Doran 1, Liz Moore 2, Martin O Leach 2 1 Department.
Image-based modelling
2006 Mouse AHM Mapping 2D slices to 3D atlases - Application of the Digital Atlas Erh-Fang Lee Laboratory of NeuroImage UCLA.
Signal and Noise in fMRI John VanMeter, Ph.D. Center for Functional and Molecular Imaging Georgetown University Medical Center.
Basic MRI Chapter 1 Lecture. Introduction MRI uses radio waves and a magnetic field to make images MRI uses radio waves and a magnetic field to make images.
1 As Clinical Anatomy RADIOLOGY. COURSE GOALS  Understand basics of image generation.  Relate imaging to gross anatomy.  See clinical relationship.
Filtering Objective –improve SNR and CNR Challenges – blurs object boundaries and smears out important structures.
A New Method for Crater Detection Heather Dunlop November 2, 2006.
Magnetic Resonance Imaging (MRI). The Components: A magnet which produces a very powerful uniform magnetic field. A magnet which produces a very powerful.
Quality Control Bushong Chapter 10.
MultiModality Registration Using Hilbert-Schmidt Estimators By: Srinivas Peddi Computer Integrated Surgery II April 6 th, 2001.
COMPARATIVE LATERALIZING ABILITY of MULTIMODALITY MR IMAGING in TEMPORAL LOBE EPILEPSY ¹ Karabekir Ercan, M.D. ¹ ¹ H.Pinar Gunbey, M.D. ¹ ¹ Elcin Zan,
A SIMPLE METHOD TO ASSESS ACCURACY OF DEEP BRAIN STIMULATION ELECTRODE PLACEMENT: PREOPERATIVE MRI AND POSTOPERATIVE CT IMAGE FUSION Marco Metello 1 ;
MAGNETIC RESONANCE IMAGING by PRADEEP V.EPAKAYAL. Mem.no L.
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Medical Image Analysis
MRI in Medicine Prof. E.S. Yang The Jockey Club MRI Engineering Center
Date of download: 10/12/2017 Copyright © ASME. All rights reserved.
Sunday Case of the Day Physics
Date of download: 11/14/2017 Copyright © ASME. All rights reserved.
Orthogonal and Least-Squares Based Coordinate Transforms for Optical Alignment Verification in Radiosurgery Ernesto Gomez PhD, Yasha Karant PhD, Veysi.
Optimization of Gamma Knife Radiosurgery
Source Detection by Count Excess
7.1b. Contrast coronal T1 Wtd MRI 7.1c. Contrast sagittal T1 Wtd MRI
OBLIQUE AXIAL ALONG TANDEM
Thin-section (2.5-mm) axial T1-weighted spoiled gradient-echo gadolinium-enhanced images of the brain obtained at 1.5 T for Gamma knife localization (trigeminal.
USEFULNESS OF MRI IN THE DIAGNOSIS OF SALIVARY GLAND PATHOLOGIES
Effects of ACL interference screws on articular cartilage volume and thickness measurements with 1.5 T and 3 T MRI  M.E. Bowers, B.S., G.A. Tung, M.D.,
Vahe Poghosyan, Andreas A. Ioannides  Neuron 
MEG SAMg2 data superimposed on coronal reformation (A), sagittal reformation (B), and axial MPRAGE MR imaging (C). MEG SAMg2 data superimposed on coronal.
Basics of fMRI and fMRI experiment design
FIGURE 1. Axial views of the midbrain of one Parkinson's disease patient as observed with a standard clinical 3T MRI ... FIGURE 1. Axial views of the midbrain.
MRI basics for radiation oncologists
Presentation transcript:

Tom S. Lee, Keith E. Schubert Reinhard W. Schulte Gradient Non-Linearity Correction of MR Images for Functional Radiosurgery Tom S. Lee, Keith E. Schubert Reinhard W. Schulte

Functional Proton Radiosurgery Functional Neurosurgery Trigeminal Neuralgia Parkinson’s Disease Brain regions (< 1 cm) Proton Radiosurgery accurate to less than 1 mm MRI for target localization Distinguish tissue types Gradient nonlinearity distortions (~2mm)

Obtaining the Images Coronal Plane Axial Plane Sagittal Plane

Problems to Check For Partial Slice Missing Slice Off Center Slice Leaking Slice Extra Features

Canny Edge Detection

Can We Fix It? Air Bubble Leaky Slice

What We Get Coronal Plane Axial Plane Sagittal Plane

Midplanes Average Least Squares

Ideal Planes 1 3a 2 3b

Ideal vs. Measured Planes

Distortion Correction Magnetic Field of Cylinder Sum of spherical harmonics:

Applying Distortion Correction toAxial Plane Corrected Original

Applying Distortion Correction to Coronal Plane Corrected Original

Applying Distortion Correction Sagittal Plane Corrected Original

Results Theoretical vs. corrected points Standard deviations (s) +X face: 0.23503 mm -X face: 0.25168 mm +Y face: 0.15322 mm -Y face: 0.15823 mm +Z face: 0.13548 mm -Z face: 0.14173 mm ~1-2 pixels at 3s