Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University,

Slides:



Advertisements
Similar presentations
New calorimetric technology for eRHIC. O.Tsai (UCLA) BNL, March 9, 2010 Updated, June 1, 2010.
Advertisements

1 ALICE EMCal Electronics Outline: PHOS Electronics review Design Specifications –Why PHOS readout is suitable –Necessary differences from PHOS Shaping.
First High p T Physics Prospects with the Photon Spectrometer at ALICE Kenta Shigaki (Hiroshima University ) for the ALICE Collaboration 3 rd Joint Meeting.
Quartz Plate Calorimeter Prototype Ugur Akgun The University of Iowa APS April 2006 Meeting Dallas, Texas.
JWG, 14 October, 2009, Vladislav Manko Status of work and plans of the Russian group in the ALICE Collaboration as of October, 2009.
Description of BTeV detector Jianchun Wang Syracuse University Representing The BTeV Collaboration DPF 2000 Aug , 2000 Columbus, Ohio.
October-November 2003China - ALICE meeting1 PHOS in ALICE A PHOton Spectrometer with unique capabilities for the detection/identification of photons and.
B W Kennedy, CCLRC Rutherford Appleton Laboratory VPTs for the CMS experiment B W Kennedy CCLRC Rutherford Appleton Laboratory St Petersburg, 26 April.
03/27/'07T. ISGC20071 Computing GRID for ALICE in Japan Hiroshima University Takuma Horaguchi for the ALICE Collaboration
JSPS Research Fellow / University of Tsukuba T. Horaguchi Oct for HAWAII /10/15HAWAII
PPARC forum on developments in scintillator technology R M Brown - RAL 1 Scintillating Crystals for Particle Physics Outline  Performance considerations.
Heavy Scitillating Crystals and Glasses for a Combined EM and HCal at ILC Tianchi Zhao University of Washigton Sept. 25, 2007.
PWO/APD Activities at Hiroshima U. Kenta Shigaki (Hiroshima University) 20 July 2004 at CERN.
Physics via Photons at ALICE Kenta Shigaki ( ) for the ALICE Group at Hiroshima University at ATHIC2008 on 13 October 2008 in Tsukuba.
The Design of Barrel Electromagnetic Calorimeter (BEMC) October Lu Jun-guang.
APD, CSP and T-card Characteristics Toru Sugitate / Hiroshima University for PHOS FEE Review / PRR Meeting in Wuhan, China on.
Shashlik type calorimeter for SHIP experiment
PHENIX Fig1. Phase diagram Subtracted background Subtracted background Red point : foreground Blue point : background Low-mass vector mesons (ω,ρ,φ) ~
PANDA electromagnetic calorimeters Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group INSTR08 28 Feb - 05 Mar 2008.
PWO/APD/CSP Development at Hiroshima U. Hiroshima ALICE-PHOS Group (T.Sugitate, K.Shigaki, et al.) 17 August, 2004, at CERN.
Physics in Initial Years at ALICE Kenta Shigaki, Hiroshima University (ALICE Collaboration) 30, October 2007 Workshop on Phenomenology of QGP in Heavy.
1Shanghai 14-20/11/06QM2006 Daicui Zhou PHOSPHO S PHOS, the ALICE PHOton Spectrometer The scientific objectives The design Status & Performance Daicui.
PSD8 September 2008, Glasgow.P R Hobson, Brunel University 1 Avalanche Photodiodes and Vacuum Phototriodes for the Electromagnetic Calorimeter of the CMS.
R&D on W-SciFi Calorimeters for EIC at Brookhaven E.Kistenev, S.Stoll, A.Sukhanov, C.Woody PHENIX Group E.Aschenauer and S.Fazio Spin and EIC Group Physics.
ELECTROMAGNETIC CALORIMETER at CMS EVANGELOS XAXIRIS June 2005 Experimental Physics Techniques.
Setup for hypernuclear gamma-ray spectroscopy at J-PARC K.Shirotori Tohoku Univ. Japan for the Hyperball-J collaboration J-PARC E13 hypernuclear  -ray.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Summary of PHOS Internal Notes (part I) Rafael Diaz Valdes 10/25/20151.
Valery Dormenev Institute for Nuclear Problems, Minsk
The Tungsten-Scintillating Fiber Accordion Electromagnetic Calorimeter for the sPHENIX Detector Craig Woody, for the PHENIX Collaboration Physics Department,
Quest for omega mesons by their radiative decay mode in √s=200 GeV A+A collisions at RHIC-PHENIX ~Why is it “Quest”?~ Simulation Study Real Data Analysis.
T. Sugitate / Hiroshima / PHX031 / Nov.01 The Photon Spectrometer for RHIC and beyond PbWO 4 Crystal Density 8.29 g/cm 3 Radiation length 0.89 cm Moliere.
1 Lead glass simulations Eliane Epple, TU Munich Kirill Lapidus, INR Moscow Collaboration Meeting XXI March 2010 GSI.
Shashlyk FE-DAQ requirements Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA FE-DAQ workshop, Bodenmais April 2009.
Photon Analysis Strategies at ALICE Kenta Shigaki (Hiroshima University ) ALICE Asian Workshop November 5, 2009 Yonsei University, Seoul.
The Case for the Dual Readout Calorimetry for SiD Adam Para, December 4, 2007.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Physics in Initial Years at ALICE Kenta Shigaki, Hiroshima University (ALICE Collaboration) 30, October 2007 Workshop on Phenomenology of QGP in Heavy.
APD. photosensors: L arge A rea A valanche P hoto D iodes (LAAPD) in collaboration with Hamamatsu Photonics CMS 5x5mm 2 10x10mm 2 new excellent performance.
Aerogel Cherenkov Counters for the ALICE Detector G. Paić Instituto de Ciencias Nucleares UNAM For the ALICE VHMPID group.
Concept of NA62 IRC based on PWO scintillation crystals A.Fedorov, M. Korjik, A. Lobko Institute for Nuclear Problems, Minsk, Belarus A. Kourilin JINR,
1 Diodes (APDs) for the Electromagnetic Calorimeter in the ALICE experiment Paola La Rocca University and INFN Catania Characterization of Avalanche Photo.
Edouard Kistenev for the PHENIX Collaboration Calorimetry based upgrade to PHENIX at RHIC CALOR 2012 Santa Fe, NM, June 4-8, 2012.
Mass states of light vector mesons are considered to be sensitive probes of partial chiral symmetry restoration theoretically expected in high energy and/or.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
1 Plannar Active Absorber Calorimeter Adam Para, Niki Saoulidou, Hans Wenzel, Shin-Shan Yu Fermialb Tianchi Zhao University of Washington ACFA Meeting.
Electromagnetic Calorimeter for HADES at SIS100 Pavel Tlustý, NPI Řež Motivation Plans Current status Tests Outlook HADES Collaboration Meeting, Sesimbra,
PbWO 4 crystals Calorimeter Liping Gan University of North Carolina Wilmington.
Systematic measurement of light vector mesons at RHIC-PHNEIX Yoshihide Nakamiya Hiroshima University, Japan (for the PHENIX Collaboration) Quark Matter.
High Performance PbWO 4 - Lead Glass Hybrid Calorimeter at Jefferson Lab M. Kubantsev ITEP, Moscow, Russia/Northwestern University, Evanston, USA A. Gasparian.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
CMS ELECTROMAGNETIC CALORIMETER Jean-Pierre Ernenwein OVERVIEW 6th international conference on advanced technology and particle physics Villa Olmo, Como,
Brett Fadem of Muhlenberg College for the PHENIX Collaboration.
May 10-14, 2010CALOR2010, Beijing, China 1 Readout electronics of the ALICE photon spectrometer Zhongbao Yin *, Lijiao Liu, Hans Muller, Dieter Rohrich,
CALOR 2008 Philippe Rosier – PANDA The Electromagnetic Calorimeter of the future PANDA detector P. Rosier Institut de Physique Nucléaire d’Orsay.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Gamma Spectrometry beyond Chateau Crystal J. Gerl, GSI SPIRAL 2 workshop October 5, 2005 Ideas and suggestions for a calorimeter with spectroscopy capability.
Introduction of my work AYAKO HIEI (AYA) Hiroshima Univ 2008/5/30 me.
Ilhan TAPAN* and Fatma KOCAK
The Electromagnetic Calorimetry of the PANDA Detector at FAIR
FSC status and plans Pavel Semenov IHEP, Protvino
“Performance test of a lead glass
Resolution Studies of the CMS ECAL in the 2003 Test Beam
Mickey Chiu University of Illinois at Urbana-Champaign
First physics from the ALICE electromagnetic calorimeters
Simulation study for Forward Calorimeter in LHC-ALICE experiment
Jet/Photon/Hadron Correlations at RHIC-PHENIX
Mickey Chiu University of Illinois at Urbana-Champaign
SoLID EC photonsensor.
ELECTROMAGNETIC CALORIMETER
Presentation transcript:

Photon Detector with PbWO 4 Crystals and APD Readout APS “April” Meeting in Denver, CO on May 4, 2004 presented by Kenta Shigaki (Hiroshima University, Japan) for the ALICE-PHOS Collaboration

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki2 - Presentation Outline -  physics via photon channels at LHC-ALICE  calorimeters in relativistic heavy ion experiments working environments and performance requirements best scintillation crystal and readout device candidates  basic properties of key components PbWO 4 crystals avalanche photo diode readout system  prototypes of PbWO 4 /APD calorimeter 1 st stage prototypes – 3  3 assemblies basic properties of PbWO 4 crystals and APD readout system 2 nd stage prototype – 16  16 assembly ALICE-PHOS performance evaluation  summary and outlook

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki3 - Physics via Photon Channels at LHC-ALICE -  photons in relativistic heavy ion experiments vital probes of initial/hot/dense phase of collision system direct thermal photons photon HBT correlations jet quenching experimental virtues photons and neutral mesons measured in same detector particle identification to very high transverse momentum  photons: promising though difficult many interesting physics outcome at RHIC many more waiting at LHC even more powerful tool large direct photon rate up to ~ 100 GeV large neutral meson (“background”) suppression

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki4 - ALICE Photon Spectrometer - PHOS: high-granularity high-resolution photon spectrometer PbWO 4 crystals with APD readout |  | < 0.5,  ~ 100 degrees, 17,920 channels photons and neutral mesons  -jet tagging

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki5 - Calorimeters in Relativistic Heavy Ion Exp. -  working environments high particle multiplicity high particle spatial density possibly in (high) magnetic field  performance requirements high two-cluster separation capability with high granularity high energy resolution energy range from ~ 100 MeV to ~ 100 GeV  best scintillation crystal and readout device candidates PbWO 4 (PWO) short radiation length small Moliere radius avalanche photo diode (APD) magnetic-field resistance compactness

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki6 - Basics of PbWO 4 Crystals -  dense, fast, radiation-hard inorganic scintillator density: 8.28 g/cm 3 radiation length: 0.89 cm (shortest as known inorganic scintillator) Moliere radius: 2.2 cm (smallest as known inorganic scintillator) suitable for high-granularity calorimeter refractive index: 2.3  only a few manufacturers available Furukawa (Japan), North Crystal (Russia), RI&NC (Belarus), …  optical and scintillating properties investigated transmittance scintillation light yield temperature dependence scintillation decay time ditto

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki7 - Japanese PbWO 4 Crystals -  manufactured by Furukawa, Co. density 8.28 [g/cm 3 ] radiation length 0.89 [cm] Moliere radius 2.2 [cm] peak emission [ns] refractive index x 20 x 200 mm Y-doped PbWO 4 light yieldmean decay time transmittance measured with Hitachi U3010 spectrophotometer ALICE-PHOS operation point ALICE-PHOS operation point

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki8 - PbWO 4 Crystals from Other Manufacturers -  RI&NC Co. in Minsk, Belarus adopted by CMS investigated; similar properties as Furukawa’s ref. graduation thesis by K.Yokoyama (available only in Japanese)  North Crystal Co. in Apatity, Russia adopted by ALICE-PHOS further tests at Hiroshima being prepared

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki9 - Avalanche Photo Diode Readout System -  advantages over conventional PMT readout magnetic-field resistance compactness low power consumption high quantum efficiency  ALICE-PHOS choices APD: Hamamatsu S8664 (short wavelength enhanced type) basic properties investigated breakdown voltage inverse current pre-amplifier: Bergen/Hiroshima design final decision on rise time and power consumption soon

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki10 - PbWO 4 EMC 1 st Stage Prototypes -  base prototypes – 3  3 assemblies purposes basic properties of PbWO 4 crystals R&D of APD readout system components PbWO 4 crystals: Furukawa (Japan) / RI&NC (Belarus) PMT: Hamamatsu R1450 APD: Hamamatsu S8664 pre-amplifier: Hiroshima ver.1/2 tests in Japan Tohoku-LNS (2002); photons at 0.8 – 1.2 GeV Hiroshima-REFER (2003); electrons at 150 MeV KEK-PS (planned in May/June, 2004); electrons at 1 – 3 GeV

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki11 - PbWO 4 EMC Basic Properties -  energy resolution  E /E = 2.5 %/  E [GeV]  1.3 % with PMT  position resolution  x = 2.3 mm/  E [GeV] with PMT  noise problem with APD at room temperature counts [a.u.] E total = 141 MeV σ/E total = 7.3 % = 2.8 % /  E total energy [MeV]

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki12 - PbWO 4 /APD EMC 2 nd Stage Prototype -  second stage prototype – 16  16 assembly purposes ALICE-PHOS performance evaluation and final design components PbWO 4 crystal: North Crystal (Russia) APD: Hamamatsu S8664 pre-amplifier: Hiroshima ver.2 64 channels in fast timing mode 192 channels in low power consumption mode cooled and stabilized at –25  0.1 ºC tests at CERN PS/SPS (2003): electrons and hadrons at 0.6 – 180 GeV more tests at PS/SPS (planned in June – November, 2004)

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki13 - ALICE-PHOS Performance Evaluation -   E /E = 1.3 %/E [GeV]  3.6 %/  E [GeV]  1.1 % at –  25  C

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki14 - Neutral Meson Measurement Capabilities -  hadron beams at 30 – 70 GeV/c  copper target of 6 cm thickness  invariant mass resolution  m /m = 7 % for  , 3 % for     

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki15 - Summary and Outlook -  high-granularity high-resolution electromagnetic calorimeter PbWO 4 – scintillating crystal with smallest Moliere radius APD – compact and magnetic-field resistant readout  properties of key components investigated  several prototypes fabricated/tested in Japan/Europe energy resolution  E /E ~ 3 %/  E [GeV] clear   and   peaks observed  first (out of 5) ALICE-PHOS module in  64 Russian PbWO 4 crystals + Japanese APD readout system various R&D/design/production work in progress assembly/commissioning/tests planned in 2005  ALICE at LHC starting in 2007

May 4, 2004Photon Detector with PWO and APD / APS Meeting in Denver / Kenta Shigaki16 - ALICE-PHOS Collaboration -  CERN  China(Beijing, Wuhan, Wuhan)  Czech Republic(Prague)  Germany(Münster)  France(Nantes)  Japan(Hiroshima) R.Kohara, K.Hirashita, K.Homma, K.Shigaki, T.Sugitate, D.Toyoda, Y.Tsuchimoto, K.Yokoyama  Norway(Bergen, Oslo)  Poland(Warsaw)  Russia(Dubna, Moscow, Protovino, Sarov)