Determination of the Congener Distribution in Aroclors to the Sub-ppm Level Coreen HamiltonKatharine Kaye Dale HooverBrian Fowler Axys Analytical Services,

Slides:



Advertisements
Similar presentations
Protein Quantitation II: Multiple Reaction Monitoring
Advertisements

Analysis of PCB Congeners in SRRTTF Program – Analytical Limits and Considerations SRRTTF PCB Workshop Spokane WA, Jan.13-14, 2015 Presented by Richard.
I n t e g r i t y - S e r v i c e - E x c e l l e n c e Headquarters U.S. Air Force 1 Direct Sampling Ion Trap Mass Spectrometry Rob R. Smith Oak Ridge.
PCBs, PCDD/Fs AND PBDEs IN SPIDER CRABS: COMPARISON WITH MUSSEL AND SEA BASS CONTAMINATION Conclusion  The highest contaminant levels in spider crab muscle.
1 THE NATIONAL DIOXIN AIR MONITORING NETWORK MEASUREMENTS OF CDDs, CDFs AND COPLANAR PCBs AT 18 RURAL, 8 NATIONAL PARKS, AND 2 SUBURBAN AREAS OF THE UNITED.
Vista Analytical Laboratory 1104 Windfield Way, El Dorado Hills, CA 95762, USA (916) Quantitative Analysis of Endocrine.
Validation Part 2: Cleaning validation
Summary 1 l The Analytical Problem l Data Handling.
Chapters 3 Uncertainty January 30, 2007 Lec_3.
Detect Limits as Representation for a Standard VAP Rule Discussion Dawn Busalacchi Risk Assessor, DERR, Central Office VAP Rule Discussion Dawn Busalacchi.
Laboratory requirements Dioxin Workshop, Leon Mexico Richard Turle Analysis and Air Quality Division Environmental Science and Technology Centre Environment.
Polychlorinated Biphenyls (PCBs) Toxic Substance Control Act Environmental Compliance Assistance Workshop September 13 th, 2005 Raj Aiyar (404)
Introduction to PCB Congeners Presented by Jamie Fox.
PCB 101 Spokane River Forum May 25, 2011
Quality Assessment 2 Quality Control.
Advances in Capillary Columns For Gas Chromatographic Applications
©2012 Waters Corporation MKT12XXX ©2012 Waters Corporation MESURMENT OF ACCUMULATION OF HYDROXYLATED POLYCHLORINATED BIPHENYL (OH-PCBs) IN HUMAN URINE.
Evolution of an Analytical Method for Brominated Flame Retardants K.A. MacPherson, T.M. Kolic and E. J. Reiner Ministry of the Environment –Toronto, Ontario.
Introduction to Analytical Chemistry
Distributions of 3,3 ’,4,4 ’,5-PeXB in FeCl 3 tetra-, penta-, hexa-, and hepta-XB. in FeCl 3 Etching liquid Etching waste Steel plant converter dust iron.
Measuring PCBs in Lake Ontario Surface Water Using Full-Scan Congener Methods Frederick Luckey U.S. Environmental Protection Agency, Region 2 Simon Litten.
ENVIRONMENTAL MONITORING OF DIOXIN LIKE COMPOUNDS IN THE UNITED STATES Commission for Environmental Cooperation of North America Fourth Workshop on Sources.
LC-MS/MS Analysis of Naphthenic Acids in Environmental Waters Coreen Hamilton, Million B. Woudneh & Guanghui Wang Presented at Workshop on Analytical Strategies.
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
1 / 9 ASTM D19 Method Validation Procedures William Lipps Analytical & Measuring Instrument Division July, 2015.
Rob Harvey Nate Birth.  When the physical markings of a fired bullet recovered from a crime scene are too mutilated for visual comparison or the firearm.
CONGENER SPECIFIC ANALYSIS OF POLYCHLORINATED BIPHENYLS IN THE ENVIRONMENT AND HUMAN SAMPLES T. Nakano 1, K. Tanno 2, H. Kitamoto 1, C. Matsumura 1, M.
The Separation of Beryllium from Spectral Interfering Elements in Inductively Coupled Plasma – Atomic Emission Spectroscopic Analysis Daniel R. McAlister.
HP Labs Escondido, CA Methanol and Ethanol Analysis/ J. Picker The Ultimate Gourmet Martini.
DIOXIN 2003 BOSTON SESSION SUMMARY REPORT Rapid Screening Methods Keith Worrall & Takeshi Nakano.
Organochlorine pollutants in sediments in Escambia Bay and River Johan Liebens Dept. of Earth and Environmental Sciences Carl Mohrherr (ret.) Center for.
Determination of 209 Congeners and Congener Groups by HRGC/HRMS using a Single GC Column: Details of EPA Method 1668A Brian Fowler Axys Analytical Services.
Evaluation of Intrinsic Biodegradation and Amendments to Support Enhanced Monitored Natural Recovery of Sediments Tom Krug and David Himmelheber, Geosyntec.
Polybrominated diphenyl ethers by HRGC/HRMS Coreen Hamilton Brian Fowler Louis Haviland Axys Analytical Services, Ltd.
Application of Method 1668A to the Analysis of Dioxin-Like PCBs and Total PCBs in Human Tissue and Environmental Samples Coreen Hamilton, Todd Fisher,
1 Analytical Methods for Perchlorate: Current Technology and Possibilities for the Future David J. Munch Daniel P. Hautman Office of Ground Water and Drinking.
National Institute for Agro- Environmental Sciences, Japan Nobuyasu SEIKE Temporal Trend of POPs Residue in Japanese Agricultural Soils.
William Kou Jonathan Mertz.  Each sample can cost $200 - $400 for one sample, for one isotope ratio.  Standards are precious and expensive  The data.
RIGHT SOLUTIONS | RIGHT PARTNER HRMS Centre of Excellence Brief introduction of the HRMS laboratory.
Preliminary Scoping Effort. Presentation Objectives Identify need for additional sources of future funding Provide background on how elements were identified.
SRRTTF Interpretation of Low Level PCB Data Project Objectives and Impact on +Blank Correction Procedures.
Overview of analytical chemistry Chemistry 321, Summer 2014.
 Routine viral diagnostics: indirect and direct detection of viruses. ◦ Indirect detection: serological tests; ◦ Direct detection:  Viral antigens;
International Office for Water Alice James - WG E (6), Brussels, 6 July 2009 International Office for Water Alice James - WG E (6), Brussels, 6 July 2009.
California Ambient Dioxin Air Monitoring Program (CADAMP) Kathy Gill Air Resources Board Monitoring and Laboratory Division California Environmental Protection.
Aroclor Analysis and the Challenge of Matrix Interference “Using a Holistic approach in the Laboratory to analyze uncommon matrices with Confidence and.
Levey Jennings Chart Activity Staff Meeting Topic.
Evolution GC-MS/MS: Pesticide analysis in canola oil Evolution GC-MS/MS: Pesticide analysis in canola oil Vivian Watts 1, Ingo Christ 1, Mark Misunis 2.
이 장 우. 1. Introduction  HPLC-MS/MS methodology achieved its preferred status -Highly selective and effectively eliminated interference -Without.
CHAPTER 6 Gases and Vapors. Learning Objectives Describe the various properties of the chemicals that are most important to the practice of industrial.
Techniques of Volumetric Analysis
Chemical Analysis of Fat Particles Mike Delaney, MWRA Outfall Monitoring Science Advisory Panel April 1, 2013 Update on Outfall monitoring.
Clean Water Act Methods Overview of EPA’s CWA Method Activities
PCBs Belong to 12 POPs (UNEP) Minimisation and phase-out programmes:
Gregory J. Cavallo, P.G. Thomas J. Fikslin, Ph.D.
Analysis of Low Concentrations of PAH and Alkyl PAH
Concentrations of Solutions
Mass Spectrometry Vs. Immunoassay
GERDA meeting Dubna 27-29/06/2005
GC-TRIPLE QUADRUPOLE MASS SPECTROMETRY MS/MS vs GC-HRMS FOR THE ANALYSIS OF POLYCHLORINATED DIOXINS AND FURANS UNIVERSITY OF MURCIA Agricultural Chemistry.
Representative Measurements – AQ-Workshop Bucharest, July 2008
The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners Charles Neslund, Scientific Officer, Eurofins Lancaster.
PCB Concentrations in the Ambient Waters of the Delaware Estuary and Coastal Waters: Implications for TMDLs for PCBs Thomas J. Fikslin and Gregory Cavallo.
Volume 65, Issue 2, Pages (January 2017)
Systems of Equations.
DETERMINATION OF GLUCOSE IN BLOOD STREAM
Quality Control Lecture 3
Average Atomic Mass.
Aroclors, Homologs and Congeners – An Evaluation of the Options for PCB Analysis and a Comparison of the Interpretive Value Charles Neslund, Scientific.
Presentation transcript:

Determination of the Congener Distribution in Aroclors to the Sub-ppm Level Coreen HamiltonKatharine Kaye Dale HooverBrian Fowler Axys Analytical Services, Ltd.

Presentation Outline 1.GOAL OF THE STUDY 2.ANALYTICAL APPROACH 3. DESCRIPTION OF METHOD 1668A 4.APPLICATION OF THE METHOD TO AROCLOR FORMULATIONS 5.RESULTS 6.CONCLUSIONS

Study Goals Determination of the congener composition of commercial Aroclor products.Determination of the congener composition of commercial Aroclor products. Input to risk assessment studies at contaminated sites.Input to risk assessment studies at contaminated sites. Both dioxin-like congener concentrations and other congener concentrations are of interest.Both dioxin-like congener concentrations and other congener concentrations are of interest.

Dioxin-like Congeners 12 “toxic” congeners12 “toxic” congeners Non-ortho substituted (coplanars): 77, 81, 126 and 169Non-ortho substituted (coplanars): 77, 81, 126 and 169 mono-ortho substituted 105, 114, 118, 123, 156, 157, 167, 189mono-ortho substituted 105, 114, 118, 123, 156, 157, 167, 189 Present in Aroclors at much lower concentrations (about 2 orders of magnitude lower) than the ortho-substituted congeners)Present in Aroclors at much lower concentrations (about 2 orders of magnitude lower) than the ortho-substituted congeners)

Analytical Approach “Concentrated” solutions ( ppm) of each Aroclor“Concentrated” solutions ( ppm) of each Aroclor “Dilute” solutions (5 to 10 ppm) of each Aroclor“Dilute” solutions (5 to 10 ppm) of each Aroclor Add 13 C labeled internal standardsAdd 13 C labeled internal standards Analysis by EPA Method 1668aAnalysis by EPA Method 1668a –SPB Octyl GC Column –DB1 GC Column –Fractionation on Carbon, DB1 GC Column

EPA Method 1668A Isotope dilution quantification for the 12 dioxin- like congeners and a few moreIsotope dilution quantification for the 12 dioxin- like congeners and a few more Internal standard quantification for all other congenersInternal standard quantification for all other congeners Low pg detection for dioxin-like congeners in all sample matricesLow pg detection for dioxin-like congeners in all sample matrices Minimizes interferencesMinimizes interferences

Application to Aroclors High concentration solutions to ensure detection of minor congenersHigh concentration solutions to ensure detection of minor congeners MS Source interferences when a large congener presentMS Source interferences when a large congener present Monitor lock mass channels and do not use impacted dataMonitor lock mass channels and do not use impacted data

Results Results 125 Congeners uniquely resolved on SPB Octyl GC Column125 Congeners uniquely resolved on SPB Octyl GC Column 185 Congeners uniquely or almost resolved on SPB Octyl plus DB-1 Columns185 Congeners uniquely or almost resolved on SPB Octyl plus DB-1 Columns Most dioxin-like congeners are always resolved and reliably quantified on SPB OctylMost dioxin-like congeners are always resolved and reliably quantified on SPB Octyl 77, 105, 114, 118, 167, 189, 156/157 (as a pair)77, 105, 114, 118, 167, 189, 156/157 (as a pair)

Interferences InterferencesPCB # Cl’s SPB Octyl (#Cl’s) DB-1 (# Cl’s) /115 (5) 86/125 (5) (5) 109 (5) /166 (6) 129 (6) 129 (6) /198 (6) 170 (7) 170 (7)

Results (cont’d) The 156/157 pair can be separated on a DB-1 columnThe 156/157 pair can be separated on a DB-1 column The four remaining dioxin-like congeners (81, 123, 126, 169) may need more workThe four remaining dioxin-like congeners (81, 123, 126, 169) may need more work Aroclor is a worst case situationAroclor is a worst case situation Depends on which AroclorDepends on which Aroclor

AROCLOR 1260 PCB-126 on SPB-Octyl GC Column Before Carbon Column Fractionation AROCLOR 1232 PCB-126 on SPB-Octyl GC Column No Carbon Column Fractionation AROCLOR 1260 PCB-126 on SPB-Octyl GC Column After Carbon Column Fractionation MASS: MASS: MASS:

AROCLOR 1260 PCB-129 on DB-1 GC Column Before Carbon Column Fractionation AROCLOR 1260 PCB-126 on DB-1 GC Column Before Carbon Column Fractionation AROCLOR 1260 PCB-126 on DB-1 GC Column After Carbon Column Fractionation MASS: MASS: MASS:

CONCENTRATIONS OF CONGENERS IN AROCLORS,ppm

PRECISION

ACCURACY Assumed to be high for the dioxin-like congeners due to isotope dilution technique.Assumed to be high for the dioxin-like congeners due to isotope dilution technique. Comparison to Aroclor data and toxicity data in the literature.Comparison to Aroclor data and toxicity data in the literature.

CONCLUSIONS CONCLUSIONS Use of HRGC/HRMS, carbon fractionation columns and multiple GC columns allowed isolation and quantification of dioxin-like congeners in eight Aroclor formulations.Use of HRGC/HRMS, carbon fractionation columns and multiple GC columns allowed isolation and quantification of dioxin-like congeners in eight Aroclor formulations. Quantification of dioxin-like congeners and total PCBs and was obtained from the same data set.Quantification of dioxin-like congeners and total PCBs and was obtained from the same data set.

CONCLUSIONS (cont’d) CONCLUSIONS (cont’d) Fractionation on carbon was needed for reliable quantification of some congeners.Fractionation on carbon was needed for reliable quantification of some congeners. A high degree of precision is achieved by use of isotope dilution quantification and HRMS, even for the low concentration dioxin-like congeners. Accuracy can only be inferred.A high degree of precision is achieved by use of isotope dilution quantification and HRMS, even for the low concentration dioxin-like congeners. Accuracy can only be inferred.

Acknowledgements Terry Smith, EPA Dale Rushneck, Interface, Inc.