NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3,

Slides:



Advertisements
Similar presentations
Erdem Oz* USC E-164X,E167 Collaboration Plasma Dark Current in Self-Ionized Plasma Wake Field Accelerators
Advertisements

Transverse Emittance and Energy Spread Measurements for IFMIF-EVEDA C. OLIVER Contributors: P. A. Phi NGHIEM, C. Marolles ABI Workshop on Emittance Diagnostics.
05/03/2004 Measurement of Bunch Length Using Spectral Analysis of Incoherent Fluctuations Vadim Sajaev Advanced Photon Source Argonne National Laboratory.
Coherent Radiation from High-Current Electron Beams of a Linear Accelerator and Its Applications S. Okuda ISIR, Osaka Univ Research Institute.
Bunch shape monitor for Linac-4 A.V.Feschenko Institute For Nuclear Research (INR), Moscow , Russia.
1 Laser Beam Coherence Purpose: To determine the frequency separation between the axial modes of a He-Ne Laser All sources of light, including lasers,
Matching and Synchrotron Light Diagnostics F.Roncarolo, E.Bravin, S.Burger, A.Goldblatt, G.Trad.
1 Proposal for a Multi-Optical Transition Radiation System in ATF2 A. Faus-Golfe, D. McCormick IFIC – SLAC 11 June th TB/SGC Meeting.
FACET Machine Performance and Expectations M. Sullivan for the FACET Accelerator group SAREC Review July 25, 2013.
Beam Instrumentation for Linear Colliders What is special about the beam instrumentation of a Linear Collider ? What are the main Instruments ? LC school.
Optical Transition CTF3 & ATF2 Benoit BolzonBI day, 06/12/
Recent Progress in X-ray Emittance Diagnostics at SPring-8 S. Takano, M. Masaki, and H. Sumitomo * JASRI/SPring-8, Hyogo, Japan SES, Hyogo, Japan *
DEVELOPMENT OF A COMBINED TR/DR EMITTANCE STATION FOR FUTURE LINEAR COLLIDERS T. Aumeyr 1, M. Bergamaschi 2, E. Bravin 2, P. Karataev 1, R. Kieffer 2,
Optical diagnostics for beam halo (I) Coronagraph (II) OTR halo monitor for J-PARC T. Mitsuhashi, KEK.
KEK-ATF – Fermilab Collaboration Ideas David Johnson, Alex H. Lumpkin, Vic Scarpine, Manfred Wendt, Fermilab Presented at SLAC January 10, 2011.
Free Electron Lasers (I)
05/05/2004Cyrille Thomas DIAMOND Storage Ring Optical and X-ray Diagnostics.
Beam dynamics on damping rings and beam-beam interaction Dec 포항 가속기 연구소 김 은 산.
Recent Experiments at PITZ ICFA Future Light Sources Sub-Panel Mini Workshop on Start-to-End Simulations of X-RAY FELs August 18-22, 2003 at DESY-Zeuthen,
Transverse Profiling of an Intense FEL X-Ray Beam Using a Probe Electron Beam Patrick Krejcik SLAC National Accelerator Laboratory.
Transverse beam size measurement High energy micron electron beam non-invasive diagnostics based on diffraction radiation G.Naumenko*, A.Potylitsyn, L.Sukhikh.
Institute of Atomic and Molecular Sciences, Academia Sinica, Taiwan National Taiwan University, Taiwan National Central University, Taiwan National Chung.
L. Bobb 1, 2, T. Aumeyr 1, M. Billing 3, E. Bravin 2, N. Chritin 2, P. Karataev 1, T. Lefevre 2, S. Mazzoni 2 1.John Adams Institute at Royal Holloway,
SPATIAL RESOLUTION OF NON- INVASIVE BEAM PROFILE MONITORBASED ON OPTICAL DIFFRACTION RADIATION A.P. Potylitsyn Tomsk Polytechnic University, , pr.
Coherent Diffraction Radiation experiment Konstantin Lekomtsev, Grahame Blair, Gary Boorman, Pavel Karataev, Maximilian Micheler John Adams Institute at.
A.Shapovalov (DESY, Zeuthen) (MEPhI, Moscow, Russia)
1 H. Hayano for the ATF collaboration Low Emittance Beam Generation in ATF H. Hayano for the ATF collaboration BPM electronics improvement emittance tuning.
A.P. Potylitsyn, S.Yu. Gogolev
Y. Roblin, D. Douglas, F. Hannon, A. Hofler, G. Krafft, C. Tennant EXPERIMENTAL STUDIES OF OPTICS SCHEMES AT CEBAF FOR SUPPRESSION OF COHERENT SYNCHROTRON.
PROBLEM 1 Show that the (beam size ^2) varies quadratically with distance in a drift section with no quadrupoles.
New emittance monitor beamline
Kiyoshi Kubo Electron beam in undulators of e+ source - Emittance and orbit angle with quad misalignment and corrections - Effect of beam pipe.
Beam dynamics in IDsBeam-based Diagnostics, USPAS, June 23-27, 2003, J. Safranek Beam Size Measurement m Survey of beam size measurement techniques and.
UCLA Claudio Pellegrini UCLA Department of Physics and Astronomy X-ray Free-electron Lasers Ultra-fast Dynamic Imaging of Matter II Ischia, Italy, 4/30-5/3/
T. Aumeyr 1, L. Bobb 1, 2, M. Billing 3, E. Bravin 2, P. Karataev 1, T. Lefevre 2, S. Mazzoni 2, H. Schmickler 2 1.John Adams Institute at Royal Holloway,
SL/BI 16/05/1999DIPAC’99 -- JJ Gras -- CERN SL/BI -- Adaptive Optics for the LEP 2 SR Monitors G. Burtin, R.J. Colchester, G. Ferioli, J.J. Gras, R. Jung,
Accelerator Laboratory of Tsinghua University Generation, measurement and applications of high brightness electron beam Dao Xiang Apr-17, /37.
2 February 8th - 10th, 2016 TWIICE 2 Workshop Instability studies in the CLIC Damping Rings including radiation damping A.Passarelli, H.Bartosik, O.Boine-Fankenheim,
1/26 WSHQE–October 4-6, 2006 L. Monaco INFN Milano – LASA Photocathode FLASH: Quantum Efficiency (QE) L. Monaco Work supported by the European.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
XFEL Beam Dynamics Meeting Bolko Beutner, DESY First results of micro-bunching and COTR experiments at FLASH Bolko Beutner, Winfried Decking,
J. C. T. Thangaraj Fermi National Accelerator Laboratory, Batavia, Illinois 1 Experimental studies on an emittance exchange beamline at the A0 photoinjector.
ESLS Workshop Nov 2015 MAX IV 3 GeV Ring Commissioning Pedro F. Tavares & Åke Andersson, on behalf of the whole MAX IV team.
ODR Diagnostics for Hadron Colliders Tanaji Sen APC.
OPERATED BY STANFORD UNIVERSITY FOR THE U.S. DEPT. OF ENERGY 1 Alexander Novokhatski April 13, 2016 Beam Heating due to Coherent Synchrotron Radiation.
SPARCLAB: PW-class Ti:Sa laser+SPARC
Emittance measurements for LI2FE electron beams
Collimation Concept for Beam Halo Losses in SIS 100
E-beam scanner experience at FNAL
Show that the (beam size ^2) varies quadratically with distance in a drift section with no quadrupoles.
Beam-beam effects in eRHIC and MeRHIC
Summary of experience with Tevatron synchrotron light diagnostics
ODR/OTR emittance station at ATF2 (KEK)
OTR based measurements for ELI-NP Gamma Beam Source
Application of a Streak camera at PITZ
Bi-plasma interactions on femtosecond time-scales
F. Villa Laboratori Nazionali di Frascati - LNF On behalf of Sparc_lab
Beam size diagnostics using diffraction radiation
INFN and the ILC S. Bertolucci, INFN.
LCLS bunch length monitor utilizing coherent radiation
Gain Computation Sven Reiche, UCLA April 24, 2002
Linac Physics, Diagnostics, and Commissioning Strategy P
First results of micro-bunching and COTR experiments at FLASH
Diagnostics RF and Feedback
Linac Diagnostics Commissioning Experience
Diagnostics overview Beam profile monitors Cherenkov radiators Summary
Injector Diagnostics Status
HALLA APEL REPORT Yves Roblin Hall A colllaboration Meeting
Hall A Beam Parameters Table
CLIC luminosity monitoring/re-tuning using beamstrahlung ?
Presentation transcript:

NON-INTERCEPTING DIAGNOSTIC FOR HIGH BRIGHTNESS ELECTRON BEAMS USING OPTICAL DIFFRACTION RADIATION INTERFERENCE (ODRI) A. Cianchi #1,2, M. Castellano 3, L. Catani 2, E. Chiadroni 3, G. Gatti 3, K. Honkavaara 4, G. Kube 4 1 University of Rome “Tor Vergata” v. della Ricerca Scientifica 1, Rome, Italy 2 INFN- Roma Tor Vergata, v. della Ricerca Scientifica 1, Rome, Italy 3 INFN –LNF, v. E. Fermi 40, Frascati (RM), Italy 4 DESY, Notkestrasse 85, Hamburg, Germany IX International Symposium RREPS - 11

Outlook  Importance of not intercepting diagnostic  Optical Diffraction Radiation vs Optical Diffraction Radiation Interference  Non collinear apertures  Experimental setup  Results  Horizontal polarization

High Brightness Machines [A/(m-rad) 2 ] V. Balandin, N. Golubeva High density power beam can substantially damage or destroy a foil or a wire scanner Possible alternatives are multishots devices ― Wire scanner (intercepting) ― Laser wire

Optical Diffraction Radiation (ODR)  The charge goes into the hole without touching the screen  The electromagnetic field of the moving charge interacts with the metallic screen  No power is deposited on the screen  The angular distribution of the emerging radiation is affected by the beam transverse size, the angular spread and the position inside the slit  Rectangular slit P. Karataev et al., “Beam-Size Measurement with Optical Diffraction Radiation at KEK Accelerator Test Facility”, Phys. Rev. Lett. 93, (2004)

Background noise E. Chiadroni et al., Non-intercepting electron beam transverse diagnostics with optical diffraction radiation at the DESY FLASH facility NIM B 266 (2008) 3789–3796 Mainly Synchrotron radiation, both directly coming for bending magnets and reflected from the vacuum chamber walls

Two slits geometry (ODRI) Optical Diffraction Radiation Interference (ODRI)

Collinear slits Point like beams with different angular spread Possible confusion between the contribution of the angular spread and the beam dimension

Non collinear slits The 50  m offset between the slits is enough to avoid mixing between the contributions of angular spread and beam size

Approximations and formulas  Perfect metal  Filter bandwidth negligible  Beam energy spread negligible  Beam Gaussian both in y and y’  Slit parallelism correction (M. Castellano, E. Chiadroni, A. Cianchi, “Phase control effects in optical diffraction radiation from a slit”, Nuclear Instruments and Methods in Physics Research A 614 (2010) 163–168)  Numerical code

FLASH FLASH is an excellent linac for this experiment:  High energy up to 1 GeV  Large number of bunches (up to 30) with high charge (up to 1 nC)  Frequency repetition 5 Hz  Long collaboration history

Optical System (1) High Sensitivity Hamamatsu Camera  High quantum efficiency  Air Cooling -55˚C  Long exposure time up to 2 hours Interferential filter at 800 nm Interferential filter at 450 nm Glenn-Thompson polarizer Achromat Lens with f=500 mm for DR angular distribution Lens with f=250 mm for beam imaging Hamamatsu CCD camera

Experimental Setup (1) Mirror Lenses Actuator Interferential filters Polarizer Camera holder

center -25 um -50 um -75 um -100 um -125 um -150 um Angular distribution

center +25 um +50 um +75 um +100 um +125 um +175 um Angular distribution (2)

Two different spots OTR beam 78±4 μ m 90±4 μ m ODRI beam 82 μ m 94 μ m,

A divergence of about 320 μ rad can be estimated from a quadrupole-scan emittance measurement carried out under the same experimental conditions RMS Beam Size (  m) 8278 RMS angular spread (  rad) Displacement in respect to the second slit (  m) Misalignment between two slits (  m)

Hardware evolution  New design in the mover Old screen holderNew screen holder

Experimental Setup (2) Mirror Lenses with one apochromatic lens Interferential filter 2 polarizers

Different wavelength 800 nm550 nm

Horizontal polarization Vertical Horizontal

X polarization 550 nm800 nm

Scan with the 1 mm slit 0.5  m slit out off center about -70  m 1 mm slit move range from -66  m to +200  m

To improve  Horizontal polarization features not fully understood  A control of the all known parameters is mandatory in order to make precise measurements  An analytic formula would be better than a MonteCarlo code

Conclusion  ODRI is in developing  ODRI dramatically reduce or eliminate the problem of background  Asymmetric configuration resolves parameters ambiguities  New measurements are foreseen to make a totally non intercepting emittance measurement

Thank you for your attention

Formulas

Multiple fit

Importance of side peaks

All data