Extended Detector Cutoff Considerations WFIRST Project Office May 09 2011 1.

Slides:



Advertisements
Similar presentations
CMSC 2006 Orlando Active Alignment System for the LSST William J. Gressler LSST Project National Optical Astronomy Observatory (NOAO) Scott Sandwith New.
Advertisements

Development of Sensitive Long-wave Infrared Detector Arrays for Passively Cooled Space Missions Craig McMurtry, Donald Lee, James Beletic, Chi-Yi A. Chen,
11 Components of Optical Instruments Lecture Spectroscopic methods are based on either: 1. Absorption 2. Emission 3. Scattering.
Observational techniques meeting #7. Detectors CMOS (active pixel arrays) Arrays of pixels, each composed on a photodetector (photodiode), amplifier,
Solar Orbiter EUV Spectrometer
Solar Orbiter Payload Working Group Mid-term meeting November 2002, ESTEC 1. PDD Activities - Status of PDD inputs - Discussion of each instrument.
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
Chandra X-Ray Observatory CXC Paul Plucinsky CUC September Overall Status of the Instrument 2.Update on Controlling the FP Temperature ACIS Ops.
1 PHYSICS Progress on characterization of a dualband IR imaging spectrometer Brian Beecken, Cory Lindh, and Randall Johnson Physics Department, Bethel.
Impact of Cost Savings Ideas on NGAO Instrumentation December 19, 2008 Sean Adkins.
1 NGAO Instrumentation Studies Overview By Sean Adkins November 14, 2006.
Telescopes (Chapter 6). Based on Chapter 6 This material will be useful for understanding Chapters 7 and 10 on “Our planetary system” and “Jovian planet.
IRMS Optical Subsystem Review. The Charter Confirm that the MOSFIRE design is a feasible baseline for IRMS (yes) Verify that the MOSFIRE design can achieve.
Millimetron mision sensitivities and instrumentation concept
EPIC PN background spectra for low surface brightness sources Michael Bauer (MPE), Wolfgang Pietsch (MPE) & Ginevra Trinchieri (INAF)
1 NGAO Science Instrument Reuse Part 1: NIRC2 NGAO IWG December 12, 2006.
Summer Fun with Optics Stephen Muchovej UC Berkeley CARA - REU Program.
Rachel Klima (on behalf of the MASCS team) JHU/APL MASCS/VIRS Data Users’ Workshop LPSC 2014, The Woodlands, TX March 17,2014 MASCS Instrument & VIRS Calibration.
Grazing-incidence design and others L. Poletto Istituto Nazionale per la Fisica della Materia (INFM) Department of Electronics and Informatics - Padova.
WFIRST Instrument reference information July 1, 2015.
Sergey Mekhontsev National Institute of Standards and Technology Optical Technology Division, Gaithersburg, MD Infrared Spectral Radiance Scale.
Interim progress summary: ITER Imaging X-ray crystal spectrometer design Sam Davis - UKAEA Robin Barnsley - ITER.
Presentation EddiCam consortium, FF, Madrid 13/06/2002 Eddington programmatic status Fully approved by SPC as part of ESA’s science program as project.
STATUS REPORT OF FPC SPICA Task Force Meeting March 29, 2010 MATSUMOTO, Toshio (SNU)
Galactic Bulge Time On Target May These charts examine the compatibility of a 500 day microlensing program with a 6 month SNe observing program.
Chile Sky Background at ESO/la Silla in the Visible and Near IR Leonardo Vanzi -Olivier R. Hainaut European Southern Observatory La Silla - Chile.
6/11/2012 Building on NEAT concept - M. Gai - INAF-OATo 1 Building on NEAT concept M. Gai – INAF-OATo (a) Extension of science case (b) Payload implementation.
UV-Vis Absorption Spectroscopy
NIRSpec Operations Concept Michael Regan(STScI), Jeff Valenti (STScI) Wolfram Freduling(ECF), Harald Kuntschner(ECF), Robert Fosbury (ECF)
3.1 Optomechanical systems (1) Scientific and engineering resources are available to carry out the optomechanical work on DECam. The highly distributed.
Progress Report Geo-CAPE Coastal Ecosystem Dynamics Imager (CEDI) IRAD Repackaging Study Jason Budinoff / GSFC Cathy Marx / GSFC May 12, 2011.
DRM1 design description SDT 5/17/12 1. WFIRST DRM candidate design summary At SDT6 2/2-3/2012 consensus for full-up mission, aka “DRM1” was: 1.3m aperture,
K band History Science workshop determined efficiency improvements necessary for K Band: weather, observing requests, mapping programs. Only enough funds.
WFIRST 10  m Pixel Pitch Detector Considerations March 10, /10/
Jörn Helbert Planetary Emissivity Laboratory Facing the heat – Obtaining near infrared real emissivity spectra at Venus surface temperatures.
GBT Focal Plane Array Development Program Steven White Program Manager.
Optical & Radiometric Conceptual Design of EMAS Thermal Port Upgrade Kickoff Meeting June 29, 2010 Roy W. Esplin.
Page 1 MIRAC3-BLINC Magellan results MIRAC4-BLINC plans Static and Deformable Secondaries Phil Hinz and Bill Hoffmann Steward Observatory Giovanni Fazio.
PACS IHDR 12/13 Nov 2003 Filters1 N. Geis MPE. PACS IHDR 12/13 Nov 2003 Filters2 PACS Filter Scheme Filter scheme with 5 or 6 filters in series in each.
FELT 1 Study of the capability and configuration of a fixed mirror Extremely Large Telescope (FELT) Low cost path to large telescope Primary concern is.
SNAP Calibration Program Steps to Spectrophotometric Calibration The SNAP (Supernova / Acceleration Probe) mission’s primary science.
A Modular K-Band Focal Plane Array for the Green Bank Telescope Matt Morgan National Radio Astronomy Observatory 9/28/2007.
START NICMOS COOLING SYSTEM ACTIVITY SUMMARY. 1/25/01Ken Pulkkinen2 START NCS ACTIVITY Applicable SMOV Requirements: J NICMOS Cooling System.
PVPhotFlux PACS Photometer photometric calibration MPIA PACS Commissioning and PV Phase Plan Review 21 st – 22 nd January 2009, MPE Garching Markus Nielbock.
TIPS - Oct 13, 2005 M. Sirianni Temperature change for ACS CCDs: initial study on scientific performance M. Sirianni, T. Wheeler, C.Cox, M. Mutchler, A.
Optical characteristics of the EUV spectrometer for the grazing-incidence region L. Poletto, G. Tondello Istituto Nazionale per la Fisica della Materia.
17.1 Atmosphere Characteristics
WFIRST DRM2 candidate design – payload summary At SDT7 3/1-2/2012 consensus for concepts w/out overlap w/ other mission, aka “DRM2” was: 1.1m aperture,
Astronomical Observational Techniques and Instrumentation
11-Jun-04 1 Joseph Hora & the IRAC instrument team Harvard-Smithsonian Center for Astrophysics The Infrared Array Camera (IRAC) on the Spitzer Space Telescope.
K-Band Focal Plane Array Project Engineering Overview Matt Morgan National Radio Astronomy Observatory 2/27/2008.
2/6/2016 DCH-1 JWST/MIRI Space Telescope Science Institute The Infrared Sky: Background Considerations for JWST Dean C. Hines & Christine Chen MIRI Instrument.
Introduction NICMOS (Near-Infrared Camera and Multi-Object Spectroscopy) was installed on the Hubble Space Telescope during SM2 in 1997 and has been the.
Observations of Near Infrared Extragalactic Background (NIREBL) ISAS/JAXAT. Matsumoto Dec.2-5, 2003 Japan/Italy seminar at Niigata Univ.
Upgrade PO M. Tyndel, MIWG Review plans p1 Nov 1 st, CERN Module integration Review – Decision process  Information will be gathered for each concept.
WFIRST Large-cell structure concept design Preview Work in progress 3/4/2016Robin Lafever1.
“Phase C” Design of the JWST/FGS Tunable Filter Imager TIPS/JIM June 15, 2006 Alex Fullerton STScI / UVic.
1 Airborne Science Program EMASHSI Kick Off Meeting Interfaces NASA Ames Research Center University of California Santa Cruz Airborne Science & Technology.
Increased Thermal Background for the post-NCS NICMOS TIPS – June 19, 2003 Megan Sosey NICMOS.
PACS IIDR 01/02 Mar 2001 Optical System Design1 N. Geis MPE.
NIRSpec - the JWST Multi-Object Spectrograph P. Ferruit (ESA), S. Arribas (CSIS), S. Birkmann (ESA), T. Böker (ESA), A. Bunker (Oxford), S. Charlot (IAP),
Astronomical Spectroscopic Techniques. Contents 1.Optics (1): Stops, Pupils, Field Optics and Cameras 2.Basic Electromagnetics –Math –Maxwell's equations.
Astronomical Spectroscopic Techniques
30-Nov-2006 Jean-Marc Defise - CSL
C.Baltay and S. Perlmutter December 15, 2014
Planck instruments’ reach coldest temperature in outer space
Detective Quantum Efficiency Preliminary Design Review
New Debris Disks With Spitzer Space Telescope
SLHC Non-Inner Detector Upgrades
CHEOPS - CHaracterizing ExOPlanet Satellite
Presentation transcript:

Extended Detector Cutoff Considerations WFIRST Project Office May

WFIRST Payload 2 Detector baseline: H2RG with 2.1  m cutoff based on current EDU development activities –Testing on devices to date indicate excellent performance Payload thermal zones based on 2.1  m cutoff Instrument Optics & Filter Wheel (cooled by radiation off of the housing) <180K Telescope Optics <240K Focal Planes (cooled by FPA radiator) <120K Instrument Cavity created to shield instrument during 45˚ rolls FPA Radiator <110K

Imaging Channel –A longer imaging channel cutoff wavelength can be viewed as having impacts in a few categories. –Detector dark current: At a given temperature, the dark current will increase for longer cutoffs. –For 2.0  m to 2.5  m at 120K, dark current increase is on the order of ~100x. –To keep the same dark current, the temperature would have to be decreased by ~ 20-30K. »The detector Focal Plane Array (FPA) is already the coldest component, and would require a radiator area increase by ~2.5x to achieve this lower temperature. –A dark current increase will affect all observations in all wavelength bands. –Instrument/detector cavity (FPA to cold pupil): The optical beam fills only a small solid angle at the detector. Most of the detector solid angle views an effective instrument cold shroud temperature. –This thermal radiation is absorbed over the entire pass band of the detector. –With the addition of 2.0  m to 2.5  m band with a 180K shroud, the in-band internal emissions increase is on the order of ~2000x. –To keep the same cold shroud contribution, the temperature would have to be decreased by ~35K. »Would require detailed modeling of a specific design to validate the performance feasibility –Telescope: The filters will only allow in-band radiation to reach the detectors from upstream optical components. The WFIRST DRM has no filters that pass radiation beyond 2.0 microns. If we add filters that pass radiation between 2.0 and 2.5 microns, the background in this band will be ~100x higher than the Zodiacal background (when keeping the telescope and optics temperature constant). This extra background only affects observations made in the 2.0 to 2.5 micron filters band pass. Options: –Accept telescope internal emissions noise in 2.0 to 2.5 band. –Cool telescope by ~40K to make its internal emissions a fraction of Zodi min (design, fabrication, test implications). 2.5 Micron Cutoff Wavelength Design Impacts 3

Imaging Channel (continued) –Filters: The extension of band pass to 2.5 microns will require at least one or perhaps two additional filters. –Requires increasing the size of an already large filter wheel assembly, –Or tradeoffs with other filter requirements, –Or two filter wheel assemblies. The filter wheel mechanism(s) become more challenging. –Design and test temperatures must be lowered to be consistent with instrument/detector cavity temperature. –Schedule impact of colder testing. Spectrometer Channel Trade study required to evaluate fabricating two kinds of detectors with different cutoffs vs. increased cooling for spectrometer channel. Optical material properties shortcomings in the 2.0 to 2.5 band make extending performance into the 2.0 to 2.5 micron band very challenging. Assumption used here is that the same detectors as the imager will be used, band limited to 2.1 micron cutoff if necessary. 2.5 Micron Cutoff Wavelength Design Impacts 4

Rough cost estimate for extending imager long-wavelength coverage from 2.0 microns to 2.5 microns: $50M to $80M Rough estimate does not entertain extended spectrometer channel band pass. Assumption is that appropriate additional cooling for the spectrometer channels would be included for devices with 2.5 micron cutoff, while maintaining the 2 micron science band pass cutoff. Considerations –Increase in focal plane arrays radiators cooling power (size vs heatpipes etc.) Labor, fabrication, test, FOV constraints vs observatory pointing –Lower telescope temperature Material, parts, processes qualification assurance Cryo figuring of optics, test, metrology Additional assembly-level test time –Extended observatory thermal vacuum testing –Larger filter wheel or 2 filter wheels –Colder filter wheel(s) –Additional filters to cover 2.0 to 2.5 micron band Cost Impacts From Extension To 2.5 Microns 5