Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer.

Slides:



Advertisements
Similar presentations
Focusing monochromators/analyzers Asymmetric diffraction geometry of the monochromator Dispersive double crystal monochromator Two wavelength sandwich.
Advertisements

Stanford Synchrotron Radiation Lightsource Sources and Optics for XAS Apurva Mehta.
Pair Spectrometer Design Optimization Pair Spectrometer Design Optimization A. Somov, Jefferson Lab GlueX Collaboration Meeting September
Upcoming Review of the Hall D Photon Beam and Tagger Richard Jones, University of Connecticut, for the GlueX collaboration GlueX Collaboration Meeting.
OL 750 Measurement Systems
Hardware Progress Doug Abernathy ARCS Instrument Scientist ARCS IDT Meeting Lujan Center, LANL September 30, 2002 SNS Instrument SystemsArgonne/Oak Ridge.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
SNS Experimental FacilitiesOak Ridge X /arb Neutron Instruments for Materials Research T.E. Mason Experimental Facilities Division Spallation Neutron.
HYSPEC Hybrid Spectrometer Instrument Development Team April, 2002 A High Performance Hybrid Spectrometer for the Single Crystal Studies at the Pulsed.
Neutron Generation and Detection Lee Robertson Instrument & Source Division Oak Ridge National Laboratory 17 th National School on Neutron and X-ray Scattering.
Managed by UT-Battelle for the Department of Energy Current and Future Instrument Development Projects at Oak Ridge Lee Robertson Instrument DevelopmentGroup.
Polarized Beams Using He-3 at the NCNR Triple-Axis Spectrometers Ross Erwin Tom Gentile Wangchun Chen Sarah McKenney.
HPS Test Run Setup Takashi Maruyama SLAC Heavy Photon Search Collaboration Meeting Thomas Jefferson National Accelerator Facility, May 26-27,
Progress on the New High Intensity Cold Neutron Spectrometer, MACS C. Broholm 1,2, T. D. Pike 1,2, P. K. Hundertmark 1,2, P. C. Brand 2, J. W. Lynn 2,
Conceptual Design: MACS is designed to maximize the efficiency for energy resolved surveys of Q-space in the sub-thermal energy range. Two innovations.
Neutron Conversion Factors E (meV) =  -2 (Å -2 ) E (meV) = k 2 (Å -2 ) E (meV) =  10 6  -2 (m 2 /  sec 2 ) T (K) = E (meV)
Designer and Manufacturer of Scientific Instruments Since 1985.
SHMS Optics and Background Studies Tanja Horn Hall C Summer Meeting 5 August 2008.
HYSPEC HYSPEC INSTRUMENT DESIGN – OUTLINE  The two “models” considered for HYSPEC – inside & outside (Mark)  A breakdown of the components of the two.
HYSPEC Recent progress and polarization analysis capabilities ORNL: B. Winn, V. Ovidiu Garlea, M. Graves- Brook, Peter Jiang, X. (Tony) Tong BNL: L. Passell,
Yuri Kamyshkov/ University of Tennessee Mini-Workshop, WU St. Louis, February 11, 2011 (Playing with various factors)
Proposal for a High Intensity Chopper Spectrometer at LANSCE Science requiring high sensitivity neutron spectroscopy Limitations of current instrumentation.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST February 17, 2003Timothy D. Pike1 Developing MACS A Third Generation Cold Neutron Spectrometer.
Simulations of the double funnel construction for LET. Comparison with a single funnel The aim was to optimise the double funnel configuration to give.
HYSPEC options for wide angle TOF neutron polarization analysis with polarized 3 He L. Passell, V.J. Ghosh, L.D. Cooley, I. Zaliznyak, S.M. Shapiro, W.J.
On the way to neutron scattering at 40 T Report from this workshop Discussions with NSF/DOE/SNS Letter of Intent to SNS Conceptual design project proposal.
Choosing the Right Neutron Spectrometer Dan Neumann NIST Center for Neutron Research
DECam Daily Flatfield Calibration DECam calibration workshop, TAMU April 20 th, 2009 Jean-Philippe Rheault, Texas A&M University.
Building MACS  Goals of the MACS project  Funding and time line  Technical overview  Possible IDG contributions  Process for IDG involvement in MACS.
Can Multipole Magnetic Fields Play a Useful Role in Transporting, Polarizing and Focusing Neutron Beams on Small Samples? V. J. Ghosh A.U. Luccio L. Passell.
HYSPEC 1 Instrument design, shielding/background simulations for Hyspec Vinita J. Ghosh.
Start Counter Collaboration Meeting September 2004 W. Boeglin FIU.
HYSPEC IDT HYSPEC - Hybrid Spectrometer for the Single Crystal and Polarized Neutron Studies at the SNS Steve Shapiro and Igor Zaliznyak Center for Neutron.
The HYSPEC Polarized Beam Spectrometer Barry Winn, Mark Hagen, Mark Lumsden, Melissa Graves-Brook David Anderson, Xin Tony Tong B2.5, rm G, 3:15-3:30 PM.
1 Data Acquisition What choices need to be made?.
Projected performance of NPDGamma and new systematics introduced by SM polarizer Christopher Crawford University of Kentucky NPDGamma Collaboration Meeting.
Polarized Neutrons in ANSTO – From LONGPOL to Pelican, Taipan, Sika, Platypus and Quake Dehong Yu and Shane Kennedy Bragg Institute, ANSTO, Australia.
MACS Concept and Project Status Making best use of CW source MACS-imizing incident flux MACS-imizing detection efficiency From concept to reality Collin.
HYSPEC HYSPEC: A High Performance Polarized Beam Hybrid Spectrometer at the SNS Beamline 14B I.Zaliznyak 1, S. Shapiro 1, L. Passell 1, V. Ghosh 1, W.
David Winogradoff Haverford College NCNR, NIST Ivan Schroder
HYSPEC IDT Polarized Beam Operation of the Hybrid Spectrometer at the pulsed Spallation Neutron Source. Outline HYSPEC: project timeline and place in the.
1 Status of FNPB Geoff Greene / Nadia Fomin University of Tennessee.
The NCNR Spin-Polarized Triple-Axis Spectrometer (SPINS) The SPINS instrument is located at the heart of the cold neutron guide hall of the NIST Center.
MACS –a New High Intensity Cold Neutron Spectrometer at NIST September 24, 2002Collin L. Broholm Timothy D. Pike 1 Scientific Program and Requirements.
Parameters of the new diffractometer “ARES” Aleksey E. Sokolov PNPI NRC “KI”
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
Conceptual design and performance of high throughput cold spectrometer : MACS Why MACS Layout and key elements Performance Data collection Scientific program.
Past and Future Insights from Neutron Scattering Collin Broholm * Johns Hopkins University and NIST Center for Neutron Research  Virtues and Limitations.
MCNSI meeting, February 2006 Contents: People –V. Ryukhtin left for part time only Multichannel focusing benders – continuation –resolution functions.
NMI3 meeting, ISIS, September 26-29, 2005 Contents: Overview of new capabilities of the RESTRAX software Numerical optimizations of TAS parameters Virtual.
A New High Intensity Cold Neutron Spectrometer at NIST J. A. Rodriguez 1,3, P. Brand 3, C. Broholm 2,3, J.C. Cook 3, Z. Huang 3, P. Hundertmark 3, J. Lynn.
Parameters of the new diffractometer TEX Responsible: Yu.Kibalin, I.Golosovsky.
CAPABILITIES Desire to measure lattice and spin dynamics in small single crystals:  Need high flux at sample position.  Low background Science Needs:
Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on work from: France:POMME B. Bonin et al. Nucl. Inst.
Photon Source and Tagger Richard Jones, University of Connecticut GlueX Detector ReviewOctober 20-22, 2004, Newport News presented by GlueX Tagged Beam.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline BNL’s HYSPEC project and its place in the.
HYSPEC IDT Introduction to HYSPEC: Overview of the Conceptual Design and Top Level Specifications. Outline Overview of the HYSPEC layout and principal.
Neutron Scattering Group March, 2001 A High Performance Hybrid Spectrometer for the Single Crystal Spectroscopy at the Pulsed SNS  Scientific case and.
HYSPEC IDT Options for polarization analysis with 3 He for the Hybrid Spectrometer (HYSPEC) L. Passell, V.J. Ghosh, I. Zaliznyak, S. Shapiro, W. Leonhardt,
HYSPEC IDT HYSPEC: Our Instrument at the Spallation Neutron Source. Outline Spallation Neutron Source (SNS) and the BNL Overview of the SNS instrument.
Moving the NPDGamma Experiment to the SNS FnPB Christopher Crawford University of Kentucky overview of NPDGamma transition to the SNS expected.
HYSPEC IDT Polarized Beam Mode for the Hybrid Spectrometer (HYSPEC) at the Spallation Neutron Source. Outline Polarization analysis and the HYSPEC place.
October, 2001 Hybrid Spectrometer for Single Crystal Studies at the Pulsed SNS: an update. n Principal features of the proposed hybrid spectrometer. n.
New optics for X’Pert PRO
The NPDGamma Experiment at the SNS FnPB
OL 750 Measurement Systems
MIRACLES budget: Summary of the 3 configurations
Scope Setting Meeting MIRACLES
Fig. 1 Phonon dispersion along Q = [2 + H, −2 + H, 0] (L = 0 ± 0
USAXS/USANS and slit smeared instruments in general
Presentation transcript:

Neutron Scattering Group February, 2001 A High Performance Instrument for the Single Crystal Spectroscopy at the Pulsed SNS. n What is the spectrometer we want and what is its place in the proposed SNS instrument suite? n Main criteria for the optimal design of an instrument at the pulsed source. n Hybrid (crystal monochtomator) versus chopper spectrometer: general considerations and Monte-Carlo results. L. Passel, V.Ghosh, Brookhaven National Laboratory L. L. Daemen, P. Seeger, Los Alamos National Laboratory Igor Zaliznyak Outline

Neutron Scattering Group Neutron spectrometer for studies of the low-energy coherent excitations in single crystals. Common requirements for a single crystal neutron spectrometer: Transmission function for both primary (monochromator) and secondary (analyzer) spectrometers should be close enough to 1 within the acceptance range, and vary smoothly over a substantial energy range, typically from 5meV to 100meV. Both spectral (energy resolution) and angular (~ wavevector resolution) acceptances of the monochromator and analyzer should be flexible and easily adjusted, typical resolutions are 1% to 5%. Scattering volume seen by a detector should be well defined and easily adjustable depending on the sample size, to minimize the background. Efficient use of the large incident neutron beam by focusing it on the sample is very important, and should be previewed.

Neutron Scattering Group SNS workshop on Inelastic Neutron Scattering: where is the instrument we want?

Neutron Scattering Group What is a flagship inelastic instrument at a spallation neutron source? MAPS at ISISProposed chopper spectrometer at SNS SNS should be equipped with the top of the line instruments, which will be the best performers in their class SNS spectrometers should rely on the latest technology, and feature original and innovative design Direct geometry chopper spectrometer?

Neutron Scattering Group What is it that we want to study? Coherent low-energy excitations in single crystals Different coherent static phases, ordered and weakly disordered states Magnetic vs structural scattering: polarization-dependent cross-section Reasonably small samples CuGeO3 sample from Masa Arai group, used for measurements on MAPS

Neutron Scattering Group How does the instrument we discuss fit SNS floor layout? Follows a long, 30 m to 50 m neutron guide meV direct geometry high resolution (~1%) chopper spectrometer (Abernaty) is more compact (at ~11m guide).

Neutron Scattering Group What are the general guidelines for the optimal design of an instrument at the pulsed spallation source? Pulsed nature of the neutron beam should be used The monochromatic “useful” neutron current through the sample should be maximized Solid angle accepted by the secondary spectrometer should be made as large as possible The direct view of the source by the sample should be avoided Scattering volume seen by a detector should be reduced to minimum, determined by the sample size Note: once the time structure of the neutron beam is used for either the monochromator or the analyzer, no additional gain will result from using it for both.

Neutron Scattering Group Optimization of the neutron optics for the chopper spectrometer: MC results. Basic layout for the direct geometry disc chopper spectrometer Optimized layout: curved guide loses ~6%, tapered section gain <1.4

Neutron Scattering Group Two layouts for the low-energy direct geometry spectrometer: TOF vs PG crystal monochromator.

Neutron Scattering Group MC simulation for the PG(002) monochromator transmission and focusing properties. Perfectly collimated beam Beam from 3  c supermirror guide Ei=14.7meV

Neutron Scattering Group Punchline: pro’s and con’s of a crystal monochromator hybrid spectrometer. Advantages The flux at the sample is maximized for all incident neutron energies by using the segmented crystal with vertical focusing Moving the sample and its environment out of the direct beam should significantly reduce the background in the detector bank The wavevector acceptance of the analyzer is very flexible and easily adjustable in the crystal reciprocal space (avoid the blank spots, etc.) The wavevector resolution may be easily controlled by adding collimators, a very high Q-resolution is possible The spectrometer is open for various kinds of the focussing options at the monochromator: 2D focusing, focusing with the asymmetrically cut perfect crystals, etc. The spectrometer can be fitted with the polarization analysis using the available technology: a Heusler crystal monochromator for the high- energy incident neutrons and an array of bender polarizers for the scattered neutrons. The pulsed time structure of the neutron beam is used in full

Neutron Scattering Group Punchline: pro’s and con’s of a crystal monochromator hybrid spectrometer. Disadvantages Need to move an extremely bulky back end with detector bank, covering a significant solid angle Coupling between the resolution functions of the primary and secondary spectrometers Smaller than 1 and energy dependent reflectivity of the monochromator? Smaller solid angle coverage of the detector bank?