November 11 SESAPS 2006 Samir Guragain 1 Calibration, Installation & Commissioning of Sensors for the Alignment of Muon Endcap Chambers in the CMS Experiment.

Slides:



Advertisements
Similar presentations
R. Lee CMS EMU Alignment: 28 Feb, COCOA Simulation and Study of the EMU Alignment System Robert Lee CMS Endcap Alignment Muon EDR 28 February 2002.
Advertisements

Skeleton: Hardware Alignment for EMU meeting James N Bellinger 15-Mar-2009.
First CMS Results with LHC BeamToyoko Orimoto, Caltech 1 First CMS Results with LHC Beam Toyoko Orimoto California Institute of Technology On behalf of.
Hardware activity at SX5 including detector alignment for the next three years Valery Andreev UCLA October 9-10, 2006 UCLA DOE review, task L.
US CMS DOE/NSF Review: May 8-10, Endcap Alignment Dick Loveless DOE/NSF Review 9 May 2001.
Muon Endcap Alignment Software & Calibration February 2006 Muon Endcap Alignment Software & Calibration February 2006 Samir Guragain, Marcus Hohlmann Florida.
MUON_EDR-06 (Alignment) Enrique Calvo Alamillo February 28-March 1, 2002 Link Mechanics: Status.
The RASNIK Alignment System. Particle Physics CERN, Geneva, Swiss.
Analog Alignment Sensors Status report – April 2004 Marcus Hohlmann Florida Tech.
Calibration of clinometers for the alignment of muon chambers in the CMS experiment. Thomas MOSCHOUTIS, Marion RIPERT and Georgia KARAGIORGI with Dr HOHLMANN.
Muon Endcap Alignment Analog Sensor Calibrations & Software Update Samir Guragain, Marcus Hohlmann Florida Tech October 2005 USCMS EMU meeting – Fermilab,
Goal : Setup and monitor “chambers” with resolution of < 200  m Demonstrate System Redundancy Test Setup : 1 SLM Line 1 Transfer Line 1 Transfer Plate.
Goal : Setup and monitor “chambers” with resolution of  < 200  m Demonstrate System Redundancy Test Setup : 1 SLM Line (2 Laser Redundancy) 1 Transfer.
First Reconstruction Results on the Alignment of Muon Endcap Chambers in the CMS Experiment at CERN S. Guragain, G. Baksay, M. Hohlmann Florida Tech 74.
1998 IEEE Nuclear Science Symposium, Toronto, Canada High-Precision, Large-Volume Particle Tracking U. Bratzler* Outline (Example: Muon Tracking in ATLAS)
Muon-raying the ATLAS Detector
Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger,
Novel Semi-Transparent Optical Position Sensors for high-precision alignment monitoring applications Sandra Horvat, F.Bauer, V.Danielyan, H.Kroha Max-Planck-Institute.
Alignment Software from the ME perspective Marcus Hohlmann Florida Tech Muon Alignment meeting during CMS week - CERN, March 15, 2005.
Calibration of Analog Sensors for the Alignment of Muon Chambers in the CMS experiment Marion Ripert, Georgia Karagiorgi, Thomas Moschoutis Dr. L. Caraway,
1 James N. Bellinger University of Wisconsin-Madison 27-November-2009 Status of Transfer Line Reconstruction James N. Bellinger 27-November-2009.
The Compact Muon Solenoid. What does CMS do? The Compact Muon Solenoid is a general purpose particle detector installed at point 5 of the Large Hadron.
Kaori Maeshima (FNAL), Alignment Workshop at CERN: May 17-18, Endcap Alignment Status of Offline Software Alignment CERN 17, 18 May 2001.
Twin Solenoid Study Infinite and Short Models. Infinitive Twin Solenoid Induction in the Detector area B d = µ 0 (i d -i a ) with radius R d Induction.
First CMS Results with LHC Beam
Measurement of the Charge Ratio of Cosmic Muons using CMS Data M. Aldaya, P. García-Abia (CIEMAT-Madrid) On behalf of the CMS Collaboration Sector 10 Sector.
Chamber Alignment Pins Δy = y PG – y nom. vs. Δx = x PG – x nom. M. Hohlmann 1, G. Baksay 1, S. Guragain 1, J. Bellinger 2, D. Carlsmith 2, F. Feyzi 2,
Abstract Beam Test of a Large-area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System V. Bhopatkar, M. Hohlmann, M. Phipps, J. Twigger,
Alignment Meeting, CERN, Sept 19, 2006O.Prokofiev 1 EMU Alignment System Analog Data Analysis for ME+1yME+4 Stations Run: Aug 25-28, 2006 Magnetic field.
Calibration and production of PRAXIAL (*) sensors for the ATLAS muon spectrometer Optical Metrology - SPIE Optical Measurement Systems for Industrial Inspection.
1 James N. Bellinger University of Wisconsin-Madison 2-February-2011 Status and Plans for Endcap Hardware Alignment James N. Bellinger 2-February-2011.
Beam Test of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System Vallary Bhopatkar M. Hohlmann, M. Phipps, J. Twigger, A.
Samir Guragain, Marcus Hohlmann Florida Institute of Technology, Melbourne, FL Z′ Mass Reach MC Analysis USCMS meeting Brown University May 6 – 8, 2010.
Construction and beam test analysis of GE1/1 prototype III gaseous electron multiplier (GEM) detector V. BHOPATKAR, E. HANSEN, M. HOHLMANN, M. PHIPPS,
Reducing the Iron in the Endcap Yoke of CLIC_SiD Benoit Curé, Konrad Elsener, Hubert Gerwig, CERN CERN, June 2014 Linear Collider Detector Magnet Meeting.
EMU Meeting, CERN, Sept 18-19, 2006O.Prokofiev 1 EMU Alignment System Analog Data Analysis for ME+1yME+4 Stations Run: Aug 25-28, 2006 Magnetic field up.
ATLAS Transition Radiation Tracker End-cap Quality Control and the Characterization of Straw Deformations Michael Kagan University of Michigan Supervisor:
THE H8 TEST STAND Conceptual Design Mechanical supports Status of preparation Project schedule 1 (Brandeis, CERN, MPI, Seattle - presented by Sandro Palestini)
1 ATLAS Muon Spectrometer Alignment LHC Days in Split, 5-9 Oct J.Krstic, M.Milosavljevic Institute of Physics, Belgrade D.Fassouliotis,C.Kourkoumelis,
Javier Castillo3rd LHC Alignment Workshop - CERN - 15/06/ Status of the ALICE MUON Spectrometer Alignment Strategies & Results from Cosmic run Javier.
1 James N. Bellinger University of Wisconsin-Madison 15-March-2009 Hardware Alignment.
1 James N. Bellinger Robert Handler University of Wisconsin-Madison 11-Monday-2009 Laser fan non-linearity James N. Bellinger 20-March-2009.
CMS Status & Commissioning Menu: 1 Recent Progress Commissioning Prior to and After First Beam Commissioning with first LHC Events Outlook Wolfgang Funk.
LumiCal High density compact calorimeter at the ILC Wojciech Wierba Institute of Nuclear Physics PAS Cracow, Poland.
A. Parenti 1 RT 2007, Batavia IL The CMS Muon System and its Performance in the Cosmic Challenge RT2007 conference, Batavia IL, USA May 03, 2007 Andrea.
Interaction Region and Detector
Alignment of the CMS Tracker
on behalf of the CLIC active pre-alignment team
Tracking detectors/2 F.Riggi.
Dept. of Physics and Space Sciences, Florida Institute of Technology
A. Zhang, S. Colafranceschi, M. Hohlmann
LumiCal mechanical design, integration with LDC and laser alignment
Integration and alignment of ATLAS SCT
Martin Weber RWTH Aachen 1st LHC Detector Alignment workshop CERN
Z. Szillasi On behalf of GEM Alignment group November 15, 2017
The Compact Muon Solenoid Detector
Hardware-based CMS Alignment
Status and Plans for Endcap Hardware Alignment
Transfer Line and CSC Rφ Reconstruction
Status of Transfer Line Reconstruction University of Wisconsin-Madison
University of Wisconsin-Madison
University of Wisconsin-Madison
University of Wisconsin-Madison
A. Zhang, S. Colafranceschi, M. Hohlmann
University of Wisconsin-Madison
University of Wisconsin-Madison
CMS Week Muon Alignment
University of Wisconsin at Madison
University of Wisconsin-Madison
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

November 11 SESAPS 2006 Samir Guragain 1 Calibration, Installation & Commissioning of Sensors for the Alignment of Muon Endcap Chambers in the CMS Experiment S. GURAGAIN, M. HOHLMANN Dept. of Physics, Florida Institute of Technology, Melbourne, FL 32901

November 11 SESAPS 2006 Samir Guragain 2 An Overview Introduction of the system Sensor calibration method and result First commissioning results Summary & conclusion

November 11 SESAPS 2006 Samir Guragain 3 CMS Detector of Magnetic field 4 Tesla The CMS solenoid 13 m long with an inner diameter of 6 m Total weight t The largest superconducting solenoid ever made Overall diameter 15 m 3 Endcap disks and 4 layers on each side. Overall length 21.6 m -Z

November 11 SESAPS 2006 Samir Guragain 4 Transfer plate R-sensors Z-sensors Note: only small sample of analog sensors shown Clinometers Transfer plate DCOPS ME Alignment System The system monitors the positions of Cathode Strip Chambers relative to each other and to the MABs. The alignment uncertainty should be comparable to the chamber resolution and it is defined as 75  m for ME1/2 and 150  m for the others stations.

November 11 SESAPS 2006 Samir Guragain 5 Calibration method & result Linear mover Prec. dowel pins Precision Reference Bar Distance (cm) Typical Z sensor Response (ME1) Sensor Response (V) Results Sensor response vs distance & Ratio of sensor response to ref. Volt vs distance are linear. Slope = V/cm Error in slope = V/cm Acceptable Error Proximity sensor

November 11 SESAPS 2006 Samir Guragain 6 Installation & Commissioning at CERN Cross hair Laser adjustment to pass it through four CCDs in each DCOPS on Straight Line Monitor (SLM)

November 11 SESAPS 2006 Samir Guragain 7 First commissioning results In summer 2006, all the sensors and readout were installed and commissioned on four positive endcap layers. The detector was closed up and the huge 4 T solenoid magnet of CMS was turned on for the first time ever in Aug-Sep, Data during the magnet test phase I & II were logged successfully at different B-field plateaus and have been analyzed.

November 11 SESAPS 2006 Samir Guragain 8 Z sensor data analysis & Results on axial chamber displacement P1 P2 P3 P6 P5 P4 Z1 Finite element analysis predicts a distortion in Z-direction of endcap disks (outer edges) for about 6 mm that is in good agreement with Z1 laser displacement sensor data for upper point 2 but for lower point 5 and 6 the disk bend deformations are less than predicted. Quadratic dependence with magnetic field was observed 6 laser displacement sensors were mounted on theYE+1 disk but only 3 MABs on YB+2. Z B(T) Displacement (mm)

November 11 SESAPS 2006 Samir Guragain 9 Wire extension potentiometer At 4.0 T: The largest displacement between chambers (ME+1 station) does not exceed ~ 700  m Chamber displacement relative to transfer plates at outer edge is small (  m) Displacements between inner/outer chambers: ME+1: neg. sign => disk face compressed ME+2: pos. sign => disk face expanded ME+3: neg. sign => disk face compressed P1 P2 P3 P4 P5 P6 R2 R3 R sensor data analysis & Results on Radial displacement

November 11 SESAPS 2006 Samir Guragain 10 Capacitive fluid level monitor The bending angle for station ME+1 is larger closer to the center (~ 4 mrad) than at the outer edge of the ME+1 disk (~2.5 mrad). Inclinometer data analysis & Results on tilt angle displacement Z-stop Disk Deformation: The current under- standing of yoke disk deformations due to magnetic forces based on these clinometer measurements

November 11 SESAPS 2006 Samir Guragain 11 B (T) Proximity Sensors monitor the distances between the outer ring of muon chambers on station 1. This is the only ring where chambers do not overlap and tracks cannot be used to interpolate between SLMs. Distances between these chambers increased with magnetic field and reached up to 700  m at 4.0T. Azimuthal displacements vs. B: Proximity sensors PX sensor data analysis & Results on azimuthal displacement

November 11 SESAPS 2006 Samir Guragain 12 DCOPS beam profile 2048 pixels per CCD 14 μm pixel pitch 2048 pixels per CCD 14 μm pixel pitch Digital linear CCD-based Optical Position Sensor (DCOPS) with 4×1-d CCDs CCD 2 CCD 4

November 11 SESAPS 2006 Samir Guragain 13 Summary & conclusion About 400 analog sensors were calibrated precisely at Florida Tech and shipped to CERN for the installation. The performance of the sensors up to 4T solenoid magnet during the test was good and they clearly indicated the flexing of the large absorber disks.The results are in good agreement with the finite element analysis predictions. Now half of the system is ready to go into the underground cavern for final position of the detector.