Contrast sensitivity testing maybe a better estimate of real life visual performance when compared to Snellen acuity testing Contrast sensitivity maybe.

Slides:



Advertisements
Similar presentations
Daniel B. Roth, Henry L. Feng, Kunjal K. Modi, Howard F
Advertisements

Falls prevention. As you get older, so do your eyes This can affect your life in many ways.
Innovative Color Vision Testing (simultaneous congenital & acquired)
Psychology 4051 Spatial Vision.
Comparison of corneal astigmatism measured with 3 devices Mariko Shirayama, M.D, Li Wang, M.D, PhD, Mitchell P. Weikert, M.D, Douglas D. Koch, M.D. Cullen.
Understanding of Age-Related Macular Degeneration Diagnosis and Patient Use of Computers Tina Saparia 1, AC Roch-Levecq 2, BL Broday 2 1.University of.
Copyright restrictions may apply JAMA Ophthalmology Journal Club Slides: Diabetes Eye Screening in Minority Populations Owsley C, McGwin G Jr, Lee DJ,
Sponsored by the National Eye Institute,
A R A V I N D E Y E C A R E S Y S T E M Diseases of lens Sr.Krishnaveni.
Assessment and Management of Patients With Eye and Vision Disorders
Ruth Lapid-Gortzak MD PhD 1,2, Jan Willem van der Linden BOpt 2, and Ivanka J. van der Meulen MD 1,2 1 Department of Ophthalmology, Academic Medical Center,
Copyright restrictions may apply JAMA Ophthalmology Journal Club Slides: Macular Edema After Cataract Surgery Diabetic Retinopathy Clinical Research Network.
Driving and vision. The importance of good vision for driving can not be overemphasised.
The Effect of the Restor Multifocal IOL on Frequency Doubling Perimetry Elizabeth Yeu, MD1, Elizabeth Woznak, BS2, Nicole Kesten, BS2, Steven VL Brown,
Optometry Get Your Glasses On!. What IS an Optometrist? O An optometrist has an O.D. (Oculus Doctor). O O.D.’s can: O Examine/diagnose patients O Prescribe.
Elvin H. Yildiz, Elisabeth J. Cohen, Ajoy S. Virdi, Kristin M. Hammersmith, Peter R Laibson, and Christopher J. Rapuano Cornea Service, Wills Eye Institute,
Visual Impairment and Fall. In a 2-year follow-up population-based study, impaired visual acuity was a risk factor for fall in disabled elderly (odds.
Dr. Peter J.E. Verdegem Chief Scientific Officer.
Presented by: Sarah Wong Orthoptist II Orthoptic Unit QA 2011.
The Impact of Cataract Surgery in Patients with Low Vision Irene C. Kuo, MD Clinical Research Methods July 23, 2010.
Health outcome conference July 2004 Quality Assurance in Ophthalmic Service Monitoring Cataract Surgery Outcome Dr. Goh Pik Pin Consultant Ophthalmologist.
Abby El-Shafei Dr. Penny Asbell Ophthalmology Dept. Mount Sinai School of Medicine.
Hong Kong Eye Hospital Ms Frenchy Chiu Dr Victoria Wong IOL master
The Aging Visual System. There are normal age-related changes in the eye and visual system Decreased pupil size (miosis) – decreases illuminance but increases.
Characterization of Higher Order Ocular Aberrations (HOA) In ‘Normal’ Versus Myopic Eyes To Study The Effect Of Myopia On Higher Order Aberrations Amit.
Aging and the Senses Dr. Jan Park Oklahoma Cooperative Extension Service Oklahoma State University.
Age and Visual Impairment Decrease Driving Performance as Measured on a Closed-Road Circuit 學生:董瑩蟬.
Evaluation of refractive error measurements obtained by three different aberrometers Radha Ram, BA Li Wang, MD, PhD Mitchell P. Weikert, MD, MS Disclosure:
Endothelial Dystrophy Association with Hyperopia Glenn W. Thompson, M.D. Timothy P. Page, M.D. Authors have no financial interest.
S Gollamudi 1, M Cohler 2, E Hocking 2, J Linn 1, P Gunvant 2 1) Eye Specialty Group Memphis, Tennessee 2) Southern College of Optometry, Memphis, Tennessee.
Phoebe D. Lenhart, M.D. 1, Amy K. Hutchinson, M.D. 1, Michael J. Lynn, M.S. 2, Scott R. Lambert M.D. 1 1 Department of Ophthalmology, Emory University,
Rajendra Gyawali Consultant optometrist, Male’ Eye Clinic Maldives
Khairidzan Mohd Kamal MD
Predicting visual performance from wavefront quality metrics in cataract Konrad Pesudovs Katja Ullrich NH&MRC Centre for Clinical Eye Research, Flinders.
Cataract Extraction with Pseudoaccommodating Intraocular Lens in Patients with Previous Radial Keratotomy Ross Bloomberg, MD Niraj Shah, BS William Martin,
Endothelial Keratoplasty in Patients With an Anterior Chamber Intraocular Lens: A Montreal Experience Georges M. Durr, MD 1,2 Johanna Choremis, MD, FRCSC.
Comparison of Central Corneal Thickness and Peripheral Corneal Thickness using Sheimpflug system, Optical Coherence Tomography and Ultrasound Pachymetry.
Prospective, Randomized, Double-Blind Study Comparing Nepafenac 0.1% (Nevanac™) and Bromfenac Sodium 0.09% (Xibrom™) in Post-Op Cataract Patients Hon-Vu.
Efficacy of Bromfenac 0.09% in Prevention and Treatment of Pseudophakic CME When Used Preoperatively and Postoperatively by Melissa M. Cable, MD, FAAO,
Introduction  Selective Laser Trabeculoplasty (SLT) uses a Q-Switched frequency- doubled (532 nm), low energy Nd:YAG laser, which targets melanocytes.
DEVELOPING AND VALIDATION OF AN ARABIC VERSION OF THE VISUAL FUNCTIONING INDEX VF14 FOR CATARACT PATIENTS Abdulrahman Al-Muammar, MD, FRCSC King Abdul.
Department of Ophthalmology Rudolf Foundation Clinic Vienna Head: Prof. Dr. Susanne Binder YEWHI-Study - A Comparison Between Blue Light Filtering and.
Charles D Cohn, MD; Jay C Bradley, MD;
Blindness or low vision effects more than 3 million Americans 40 years and older, and this number is projected to reach 5.5 million by In addition.
Multifocal Intraocular Lenses Abdullah Al-assiri Mansour Farooqui Abdulrahman Al-Muammar Saudi Ophthalmology Meeting 2009.
Evaluation of Corneal Tomography in Primary Pterygium Sahil Goel, MD (Presenting Author), Murugesan Vanathi MD *The authors have no financial interests.
10 year follow up of LASIK surgery for low to high levels of myopia Qasim Qasem FRCS, Caitriona Kirwan MRCOpth, Michael O’Keefe FRCS. Institutional Affiliations:
Sherman W. Reeves, MD, MPH 1,3,4 ; Jacob A. Kozisek, OD 1,2 ; Noumia Cloutier-Gill, OD 1,2 ; David R. Hardten, MD 1,2,3,4 Accuracy of Scheimpflug Imaging.
Visual and IOP Outcomes after PRK in Pigment Dispersion Syndrome [Poster Number: P190] Kraig S. Bower, Denise A. Sediq, Charles D. Coe, Keith Wroblewski,
Prospective Multi-center Study of Reliability in Vascular Laboratory Testing of Venous Reflux Phase 1 of the INVEST study (INvestigating Venous Evaluation.
Comparison of Central Corneal Thickness, Anterior Chamber Depth, and Central Corneal Power Measurements between Two Scheimpflug Imaging Systems Yuichi.
Purpose  Amblyopia is a developmental disorder of the visual cortex affecting 2-3% of the population  Previous investigations by Ciuffreda, Levi, and.
Copyright restrictions may apply JAMA Ophthalmology Journal Club Slides: Awareness and Knowledge of Emergent Ophthalmic Disease Uhr JH, Mishra K, Wei C,
Preliminary Results after Cataract Surgery with the Aspheric Acrysof ReSTOR IOL to Correct Presbyopia Meeting of the ASCRS Chicago 8-10 February 2007 R.M.M.A.
Vision Changes with Aging Mark Swanson, OD, MSPH Associate Professor.
Clinical Effectiveness Of Contrast Sensitivity Function In Patients With Primary Open Angle Glaucoma (POAG) And Ocular Hypertension (OHT ) MOUSUMI SAIKIA.
Minimizing Risk in Visian ICL Implantation.
Accommodative Response to Desktop & Handheld Video Displays Yu-Chi Tai, PhD, James Kundart, OD, MEd, FAAO, John R. Hayes, PhD, James Sheedy OD, PhD, FAAO.
Macular Pigment and its Contribution to Spatial Vision Mukunda C Akkali 1, John M Nolan 1, Stephen Beatty 1, Veronica O’Dwyer 2, Peter A Davison 2, Grainne.
The Relationship between Macular Pigment and Visual Performance Mukunda C Akkali 1, John M Nolan 1, Stephen Beatty 1, Veronica O’Dwyer 2, Peter A Davison.
Effect of Previous Argon Laser Trabeculoplasty on Selective Laser Trabeculoplasty ASCRS 2011 Lawrence F. Jindra, MD Columbia University Winthrop University.
The effect of inter-letter spacing on reading Yu-Chi Tai, John Hayes, James Sheedy College of Optometry Pacific University, Forest Grove, Oregon ABSTRACT.
Lifestyle and Refractive Factors Associated with Progressive Addition Lens Preference The Center for Ophthalmic Optics Research, The Ohio State University.
Poster# P36 Comparison of Techniques of Measuring Anterior Chamber Depth and Corneal Curvature in Indian Eyes Sujata Das, MS, FRCS Anjula Kumari, B.Optom.
CORNEAL ENDOTHELIAL PROFILE AFTER FERRARA RING IMPLANTATION Leonardo Torquetti, MD, PhD Paulo Ferrara, MD, PhD Paulo Ferrara Eye Clinic Belo Horizonte.
Invest. Ophthalmol. Vis. Sci ;57(8): doi: /iovs Figure Legend:
L. Espandar, MD ; M. D. Mifflin, MD; M. Moshirfar MD, FACS
From: Higher Contrast Requirement for Letter Recognition and Macular RGC+ Layer Thinning in Glaucoma Patients and Older Adults Invest. Ophthalmol. Vis.
Comparison of corneal powers obtained from four different devices
Khairidzan Mohd Kamal MD
Presentation transcript:

Contrast sensitivity testing maybe a better estimate of real life visual performance when compared to Snellen acuity testing Contrast sensitivity maybe decreased in patients with early disease entities like macular degeneration, glaucoma and cataract and post refractive surgery (1-3) Clinically numerous contrast sensitivity tests are available some that measure contrast sensitivity function at various spatial frequencies example quick CSF, CSV 1000, M&S systems. Where as The Evans Letter Contrast Test (ELCT) may be more useful in cases with decreased vision.. Pinakin Gunvant Davey PhD, OD, FAAO, Raymond Maeda OD, FAAO, Aaron Seitz, PhD 2 1 Western University of Health Sciences, College of Optometry, Pomona, California, USA 2 Psychology, UC Riverside, Riverside, CA, United States Introduction Assessment of Evans letter contrast sensitivity in measuring log contrast sensitivity. Bibliography Methods Questions or comments contact Dr. Pinakin Gunvant Davey or Results Forty two individuals were tested twice using the Evans Letter Contrast Test. (28 ocular healthy and 14 with disease glaucoma, macular degeneration or cataract) The mean age of the study participants were 43 years (SD 16). Acknowledgement Conclusion and Discussion  The Evans Letter Contrast Test provides a quick and easy method of estimating lowest log contrast and may be useful test in identifying decreased contrast sensitivity in individuals with ocular pathology. (B) Statistical Analysis A B C  Altman and Bland agreement plots were generated to evaluate the agreement between the contrast sensitivity function and to investigate the tests re-test repeatability obtained using the Evans Low Contrast Test.  95% limits of agreement were calculated.  The difference in measurements of first and repeat measurements was assessed using paired samples t-test.  The mean log contrast of attempt 1 and attempt 2 was and (standard deviation 0.17 and 0.08 respectively).  The mean difference between the groups was not statistically significant (paired samples t-test: t statistic =0.36; p value =0.72).  The Altman and Bland Plots show a non significant bias of between each tests indicating overall there is no systematic error Results Purpose We would like to thank Good-lite company for graciously providing instrument support for research activity. Funding NIH1R01EY The purpose of this study was to evaluate the short term repeatability of the Evans Letter Contrast Test in measuring lowest log contrast appreciated in healthy and eyes with ocular pathology. 1) N Yamane, K Miyata, T Samej, T Hiraoka,T Kiuchi, F Okamoto, Y Hirohara, T Mihashi, T Oshika. Ocular Higher-Order Aberrations and Contrast Sensitivity after Conventional Laser In Situ Keratomeuesis. Invest Ophthalmol Vis Sci Nov;45(11): ) A Ghaith, J Daniel, R Stulting, K Thompson, M Lynn, MS. Contrast Sensitivity and Glare Disability After Radial Keratotomy and Photorefractive Keratotomy Arch Ophthalmol Jan;116(1):12-8 3) D Evans, D Gherghel D, J Bartlett, S Hosking.Contrast Sensitivity Improves Following Brimonidine Therapy in Primary Open-Angle Glaucoma: A Case for Neuroprotection? Br J Ophthalmol Dec;87(12): Evans Low Contrast Test The Evans Letter Contrast Test (ELCT) chart presents Sloan Letters optotypes line size of 20/630 (a testing distance of 1m) varying contrast in sets of 3 letters of equal contrast level. All triplets are balanced for letter difficulty and differ in contrast by 0.15 log contrast step. Study participants were tested at 13 feet in a dark environment and the retro illuminated box provided the background illumination for the ELCT chart. (see figure below chart 1) The ELCT test is backlit by the ESV-3000 testing instrument, which provides a uniform luminance of 85 cd/m2. Figure to the left Provides the information of letters on each ELCT chart and percent contrast and log contrast of each of the triplet optotypes