Acoustic Doppler Technology for Streamflow Data Collection

Slides:



Advertisements
Similar presentations
Introduction to SonTek RiverSurveyor M9 &S5
Advertisements

Water Survey Of Canada Presentation to WMO Meeting on The Assessment of the Performance of Measurement Instrumentation Geneva, Switzerland April 25, 2007.
Darryl Symonds / Jim Rogers 11Jun2014
Quantification of sediment concentrations and fluxes A comparison between optical and acoustic measurements Utrecht, 11 June 2013 – Emile Lemey.
Acoustic Doppler Current Profiler Technology Trevor Lykens, Tim Sisk, Chris Tomichek December 20, 2005.
Butt of Lewis Field Research Facility This research facility, to be located at the Butt of Lewis, will build upon the Hebridean Wave Resource Assessment,
Fish pass assessment by remote control: Towards a framework for quantifying the hydraulics at fish pass entrances Thomas Kriechbaumer 1, Kim Blackburn.
Introduction to Acoustic Measuring Equipment
Maine Water Science Center
ADCP Measurements: Laptop to NWIS via SWAMI
U.S. Department of the Interior U.S. Geological Survey Effective Review of FlowTracker Measurements OSW WebinarMike Rehmel August 27, 2013 (Please Mute.
Hydrologic Measurement Precipitation Evaporation Streamflow Channel Properties Topography GIS datasets Reading: Applied Hydrology Chapter 6.
Techniques and Methods 3-A22
Abstract We quantified turbulent dissipation in the Raritan river using both conventional methods and a novel technique, the structure function method.
Overview of ADCP “Best Practices” Report
ADCP Compass Calibrations
Dan Wagner Hydrologist Arkansas Water Science Center
Review and Rating Discharge Measurements David S. Mueller Office of Surface Water March 2010.
Improved Water Resource Management Using an Acoustic Pulsed Doppler Sensor in a Shallow Open Channel MIKE COOK, PHD Irrigation Australia July
1 4 th International Symposium on Flood Defence: Managing Flood Risk, Reliability and Vulnerability, Toronto, Ontario, Canada, May 6-8, 2008 J. Chen, J.
Discharge Measurements Created by: Jake Jacobson, ID WSC Modified by: Jeff Kitchen, CA WSC.
Get Acquainted with the Latest Versions of LC & SMBA USGS, TRDI, and SonTek Versions David S. Mueller, OSW April, 2013.
Hydrologic Measurement
Wireless Terminals at UPS PAN and LAN in the warehouse PAN and LAN in the warehouse WAN used by drivers WAN used by drivers.
Quality Assurance and Quality Control Processes for Current Measurements From USCG ATONs Jennifer Dussault Qartod II February 28,2005.
Discharge Measurement Equipment and Meter Maintenance September 2011 – Glen Hess ,TESNAR, Oregon (Many slides from USGS Surface Water Field Techniques.
 How are the data used  New data collection technologies  New ways to make the data available.
ChannelMaster Horizontal ADCP
Present by : Juan José Foronda
David S. Mueller U.S. Geological Survey Office of Surface Water
Modernizing operations at the Water Survey of Canada : From field technologies to data production André Bouchard, David Hutchinson, Brian Pessah, Jeff.
SonTek FlowTracker® Basics of Operation
ADCP Acoustic Doppler Current Profiler
Lower Saluda River Instream Flow Study TWC Study Team Workshop December 11, 2007.
Physical limnology WETA151 L6b Instruments. 9/14/2015 WETS150 Timo Huttula 2 ConductivityTemperatureDepth-probe.
Discharge (Q) Define (cfs; m 3 /s or “cumecs”) Why is Q Important? How is it measured?
LC and SMBA Updates Office of Surface Water Hydroacoustics Webinar January 6 and 9, 2008 David S. Mueller.
Cthru Technical Brief Gary Morris Center of Higher Learning Stennis Space Center.
Bertinoro Advanced Training T-RDI: Marine Measurements 1Mar2007.
Glass Flotation Network and Data Storage Lead Acid Battery Acoustic Release Anchor 378 Meter Aperture 32 3-axis vector sensors 12.2 meter spacing 378 meter.
1 BROOKHAVEN SCIENCE ASSOCIATES Abstract Magnet and Girder Integration Lewis Doom, NSLS-II Project National Synchrotron Light Source II (NSLS-II) will.
NOAA’s CENTER for OPERATIONAL OCEANOGRAPHIC PRODUCTS and SERVICES NOAA/NOS/CO-OPS Maritime Services Current Observation Project San Francisco Bay and Vicinity.
Sediment Yield and Channel Processes. Definitions Suspend Sediment – sediment (orgranic or inorganic) which remains in suspension in water for a considerable.
TROLlink Remote Metering Software Kessler Ellis Products
U.S. Department of the Interior U.S. Geological Survey IMPROVING THE QUALITY AND EFFICIENCY OF ADCP STREAMFLOW MEASUREMENTS David S. Mueller U.S. Geological.
Status Report on Bottom-Tracking ADCPs & ADPs David S. Mueller Office of Surface Water.
National Consultation with TNMC 3 May 2005, Bangkok WUP-FIN Phase II – Bank erosion study.
A. Hangan, L. Vacariu, O. Cret, H. Hedesiu Technical University of Cluj-Napoca A Prototype for the Remote Monitoring of Water Parameters.
Implementation of new hydroacoustic technologies in a national operational hydrometric monitoring program : Water Survey of Canada’s HydroAcoustic Technical.
Hydrological Information System
Paul McWilliams – Ocean 101 Spring 2004 Exploring Puget Sound Tides & Currents with the Acoustic Doppler Current Profiler (ADCP) Paul A. McWilliams.
ADCP: White Point Swash
Research and Development US Army Corps of Engineers ACOUSTIC CURRENT DOPPLER PROFILERS (ADCP’s)
Laura Balthazard. Ways to control the robots At the beginning Joystick + radio interface + computer 2.
IN SITU ADCP. ADCP IN SITU Features ADCP IN SITU is used to process data produced by profiling current meters: Instantaneous pressure measurements (on.
SIDE SCAN Theory and Operation
NEMO-O DE NEMO First results from the NEMO Test Site G. Riccobene, for the NEMO Collaboration The NEMO Collaboration is performing the Phase 1 of the project,
2003 HYPACK MAX Training Seminar1 Sample ADCP 112 – Computing Flow Quantities in ADCP Profile The ADCP Profile program displays color- coded flow data.
An Overview of the USGS Instrumentation Committee (ICOM) Date of presentation Your name and contact information here.
Importance of Testing Hydroacoustic Instruments: USGS Case Studies Kevin Oberg National Coordinator for Hydroacoustics USGS Water Mission Area.
ATM-900 Series Acoustic Telemetry Modems Introduction and Overview Communication Group: Justin Manley – Senior Director of Business Development Debbie.
SIDE SCAN Theory and Operation
1 Hydroacoustic Sediment Surrogates and Methods —test results for a small urban river— Mark N Landers, Federal Interagency Sedimentation.
U.S. Geological Survey Office of Surface Water.
Oceanographic and Meteorological (Metocean) Services
Study of Undertow for Different Beach Profile
SS Load = Discharge * SS Concentration
Manned Boat ADCP Deployment
The Instrumentation Unit of The KM3NeT Calibration Unit
Series 5300 Lithium Cell Formation System
Presentation transcript:

Acoustic Doppler Technology for Streamflow Data Collection Don Hayes Richmond, Va.

History Vane Electro-magnetic Velocity Meter Acoustic Velocity Meter Acoustic Doppler Current Profilers

Acoustic Doppler Current Profilers

ADCP Applications Instantaneous Discharge Measurement Continuous Measurement—fixed mount Hydrographic Survey Calibrate and Validate Two-Dimensional Hydrodynamic Models Estimating Sediment Concentrations Using Acoustic Backscatter

Why do people want to use ADCP’s? More accurate measurements Better science (model calibration, water quality studies, etc.) Safety and Efficiency

Theory of Discharge Measurements

Conventional Discharge Measurement Velocity Width Depth This slide illustrates the method used to make conventional discharge measurements (using a Price AA current meter). Mid-Section Method Question for the class: Can someone tell me what the name of the method used in the US (USGS) for Qm’s? Answer: Mid-section method Prior to the 1950, we used a method called the mean-section method, before a study by Young (1950) concluded that the mid-section method was easier to compute and more accurate. Width is computed as half the distance from the current section to the previous section, plus half the distance from the current section to the next section. Therefore the mid-section method. This width is then multiplied by the depth measured to compute an area. Then Q= V*A. In Europe other methods are used – including full profiles using horizontal axis current meters.

Acoustic Profiler Discharge Measurement ADCP Discharge Measurement Discharge is the total volume of water flowing through a given cross-section of water per unit of time. With an ADCP and WinRiver the total volume discharge is computed for each ADCP ensemble (vertical) from a moving boat. There is no need to stop and make individual measurements. ADCP Measures Flow through some arbitrary surface An important feature of this system is that discharge can be measured over an irregular path. Instead of measuring flow through a PLANE like we do with Price AA measurements, with an ADCP (irregular weir) we are measuring flow through a SURFACE. If you project the ship track onto the bed, imagine a surface rising vertically above that projected ship track. The SOFTWARE is computing flow through THAT surface.

Measured and Unmeasured Areas Top estimate Triangular Shore estimate Measured The top and bottom of the profile cannot be measured for the reason just discussed. As the ADCP approaches the edge of the channel the depth of flow will become too shallow for the ADCP to profile. Or in the case where a vertical wall forms the edge of water, the beams from the profiler may impinge on the wall, causing erroneous measurements. Regardless of the type of edge of water, it is necessary to estimate the discharge on both shores and add them to the measured discharge to obtain an accurate estimate of the total discharge. Vertical Shore estimate Bottom estimate

It is not magic Quality Assurance is important

Progression of ADCP Use

Indiana’s Original Tethered Boat Electronics box Handle Foam floats Original design was good –but it was more or less a home-made platform. Needed to have something that work in faster flows and provide a good platform for a variety of situations. Catamaran design Aluminum frame Wireless modems ADCP

OceanScience RiverBoat ADCP Cost is ~$2,500. Comes with ADCP cable and radio/power connectors Can be adapted to other profilers (SonTek) 47 purchased by USGS Slot for rudder

Tennessee Tethered Boat Cost: < $600 US

Nortek BoogieDopp Integrated radio modem interface Deployed from “boogie board” Discharge computation software runs on WinCE (PocketPC) Discharge is computed in real time, post-processing can be done at the office (review of data, velocity profiles) Nortek profiler portion of the project – profiler features

Remote Controlled Boat Prototype running at 18 ft/s

SonTek FlowTracker Keypad LED display 2/4 MB recorder Similar to Aquacalc Measurements stored as binary file (*.wad)

Questions?