Three Phase Motors Maths

Slides:



Advertisements
Similar presentations
“Power Factor” In Transmission System
Advertisements

EE 212 Passive AC Circuits Lecture Notes 2b EE 212.
Chapter 12 RL Circuits.
Electronics Inductive Reactance Copyright © Texas Education Agency, All rights reserved.
EE20A - Electromechanical Energy Conversion Induction Machine
Sinusoidal Steady-State Power Calculations
Power Electronics Dr. Imtiaz Hussain Assistant Professor URL :
Alternating Current Circuits
Three-Phase Induction Motor Stator. Three-Phase Alternating Current.
AC Review Discussion D12.2. Passive Circuit Elements i i i + -
Lesson 37 AC Generators II
Power Factor and Power Factor Correction
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Lesson 26 AC Power and Power Factor
LOGO LINEAR CIRCUIT ANALYSISSAJID HUSSAIN QAZI MEHRAN U.E.T, KHAIRPUR CAMPUS A.C POWERS AND POWER FACTOR.
Example 10.6 Calculating Power in Parallel Loads
Chapter 7 Copyright © The McGraw-Hill Companies, Inc. Permission required for reproduction or display.
Chapter 4 Electrical Principles
Power Triangle.
AC POWER ANALYSIS Tunku Muhammad Nizar Bin Tunku Mansur
Fundamentals of Electric Circuits Chapter 11
AC MOTOR INDUCTION MOTOR.
Example 1 A 9375 kVA, 13,800 kV, 60 Hz, two pole, Y-connected synchronous generator is delivering rated current at rated voltage and unity PF. Find the.
Chapter 22 Alternating-Current Circuits and Machines.
Technical Presentation on the new Power Saving Unit (PSU) Introduced By View Power.
Engineering Practice Electric Fitting Resistance Electrical resistance is the ratio of voltage drop across a resistor to current flow through the resistor.
POWER FACTOR CORRECTION
Fundamentals of Electric Circuits Chapter 11
Power in AC Circuits ELEC 308 Elements of Electrical Engineering
FOWLER CHAPTER 9 LECTURE 9 POWER IN AC CIRCUITS. POWER IN RESISTIVE CIRCUITS, CHAP 9 WITH A RESISTIVE LOAD, CURRENT AND VOLTAGE ARE IN PHASE. F.9.1 THIS.
Unit 5 An Introduction to Mechanical Engineering: Part One Electrical and Electronic Systems 5.2 – key points Kirchhoff postulated that in any circuit.
1 Chapter 11 AC Power Analysis 電路學 ( 二 ). 2 AC Power Analysis Chapter Instantaneous and Average Power 11.2Maximum Average Power Transfer 11.3Effective.
AC POWER ANALYSIS Instantaneous & Average Power
Chapter 7 AC Power Analysis
Alpha College of Engg & Tech Khatraj, Gandhinagar EEE( ) 1 st SEM EE-A Group 5 1 KOTADIA SMIT SATISHKUMAR ( ) 2 BHANUSHALI SHREYABEN.
Capacitors in AC Circuits. In a capacitor in a dc circuit, charge flows until the capacitor is charged. In an ac circuit with a capacitor, charge flows.
1 FOUNDATION DEGREE Course FE 101 and SC1107 COMPLEX R,L and C LOADS and the POWER WAVEFORMS.
Lecture19 Examples Presented by Robert Trajkovski.
Lab 13 – Complex Power EE 188L. Instantaneous Power Time domain.
1 11/17/2015 Power Quality Correction. 2 11/17/2015 Power Quality Correction.
1 ELECTRICAL TECHNOLOGY EET 103/4  Define and explain sine wave, frequency, amplitude, phase angle, complex number  Define, analyze and calculate impedance,
Induction Machine The machines are called induction machines because of the rotor voltage which produces the rotor current and the rotor magnetic field.
EET 221 Synchronous Machines Rafiqi.
Chapter 8 Alternating Current Circuits. AC Circuit An AC circuit consists of a combination of circuit elements and an AC generator or source An AC circuit.
Magnetic field due to an electric current
AC POWER ANALYSIS. 2 Content Average Power Maximum Average Power Transfer Complex Power Power Factor Correction.
BASIC ELECTRICAL TECHNOLOGY DET 211/3
FUNDAMENTAL OF ELECTRICAL POWER SYSTEMS (EE 270)
Power Factor Correction
KAIST NUCLEAR & QAUNTUM NICIEL SEMINAR 1 / 23 Review on Power Factor Young Seung LEE 04/26/2005 SEMINAR.
1 Chapter 3 AC Power Analysis. 2 AC Power Analysis Chapter 3 3.1Instantaneous and Average Power 3.2Maximum Average Power Transfer 3.3Effective or RMS.
Lesson 12a: Three Phase Induction Motors
Hafizism february 2007 EMT462 Electrical System Technology LECTURE V mohd hafiz ismail level II jejawi.
Chapter 5 Alternating Current
Lesson 3: Ac Power in Single Phase Circuits
THREE-PHASE INDUCTION MOTOR
Lesson 22: AC Power Factor and Power Factor Correction
Lesson 21: AC Power and Power Triangle
Sinusoidal Excitation of Circuits
Lesson 34: AC Generators II
Electric Machine Induction Motor
AC MACHINE Hasnizah Aris.
Session - 10 Basics of Power Power in D.C and Power in A.C.
Three Phase Induction Motors
Three Phase Induction Motors
Utilisation of Electrical Energy
Utilisation of Electrical Energy
Utilisation of Electrical Energy
ELL100: INTRODUCTION TO ELECTRICAL ENGG.
EEE 3230 POWER SYSTEM ANALYSIS
Presentation transcript:

Three Phase Motors Maths

Poles and Speed

Power input to the Rotor S = slip, either % or pu n = Synchronous speed (the speed the rotating mag flux rotates at and the speed the rotor is trying to get to. (rps or Hz) nR = Rotor speed. (rps or Hz) nS = Slip speed (rps or Hz) T = torque (Nm) FR = Frequency of the rotor currents. (Hz) F = supply frequency (Hz) p = No of pairs of poles P = Power (W) ER = Rotor emf at standstill (V) RR = Rotor resistance (Ω) XR = Rotor reactance (Ω)

Power developed by the rotor = 2nRT

Power Factor It is common to define the Power Factor – PF - as the cosine of the phase angle between voltage and current - or the "cosφ". PF = cos φ where PF = power factor φ = phase angle between voltage and current

The power factor defined by IEEE and IEC is the ratio between the applied active (true) power - and the apparent power, and can in general be expressed as: PF = P / S where PF = power factor P = active (true or real) power (Watts) S = apparent power (VA, volts amps)

Example - Power Factor A industrial plant draws 200 A at 400 V and the supply transformer and backup UPS is rated 200 A × 400 V = 80 kVA. If the power factor - PF - of the loads is only 0.7 - only 80 kVA × 0.7 = 56 kW

What is the PF issue? Any power factor less than 1 means that the circuit's wiring has to carry more current than what would be necessary with zero reactance in the circuit to deliver the same amount of (true) power to the resistive load

A low power factor is expensive and inefficient and some utility companies may charge additional fees when the power factor is less than 0.95. A low power factor will reduce the electrical system's distribution capacity by increasing the current flow and causing voltage drops.

"Leading" or "Lagging" Power Factors Power factors are usually stated as "leading" or "lagging" to show the sign of the phase angle. With a purely resistive load current and voltage changes polarity in step and the power factor will be 1. Electrical energy flows in a single direction across the network in each cycle. Inductive loads - transformers, motors and wound coils - consumes reactive power with current waveform lagging the voltage. Capacitive loads - capacitor banks or buried cables - generates reactive power with current phase leading the voltage.