Means of Egress Part 3 Chapter 4.

Slides:



Advertisements
Similar presentations
Stairway Construction
Advertisements

Code Analysis:Accessibility Colleen MacEachern & Stephanie Novak.
7 | Means of Egress (Life Safety Code)
MEANS OF EGRESS.
Determining the Occupant Load
Fire-Resistive Construction (2nd part)
Means of Egress Talia Ordonez Alex Prodanov Margarita Binkin Team.
DEPARTMENT OF DEVELOPMENT SERVICES BUILDING DIVISION Ronald L. Lynn, Director/Building Official Gregory J. Franklin, Assistant Director Neil Burning, Manager.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
Subpart X Ladders and Stairways 29 CFR Presented By: Joshua C. Rohrig
Week 8 Stairs and Fireplaces. Objectives This chapter discusses stairs and fireplaces: types, sizes, code requirements, design considerations, and how.
Private Stairway A private stairway is a series of steps with straight nosings on plan intended for use solely in connection with one dwelling. Tread Newel.
Stairways and Ladders 1926 Subpart X - Stairways and Ladders
BCT 104 Construction Math Stair Calculations. Stair Codes Important Residential Stair Codes 1. The maximum stair riser is 8". The minimum is 4". 2. The.
Competency: Design and Draw Stair Systems
Stairways & Ladders
of NFPA 101 Life Safety Code Administration Definitions General
Walking-Working Surfaces
`Prepared by Ricardo Brown  Describe what stair construction is.  Define terms associated with stair construction.  Calculate the unit rise, unit.
Accessibility.  A building code is a set of rules that specify the minimum acceptable level of safety for buildings. The main purpose of building codes.
Michigan Department of Licensing and Regulatory Affairs Bureau of Construction Codes.
1 Walking-Working Surfaces This material was produced under grant [SH20856SH0] from the Occupational Safety and Health Administration, U.S. Department.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
1 “Making Rural Development Multifamily Projects Accessible” Based on work by Larry Fleming RD Olympia State Office, April 2014.
IBC 2006 Chapter 5 Building Height and Areas After determining occupancies, the code analysis determines what height and areas are allowable for the occupancy.
OSHA Office of Training & Education
OSHAX.org - The Unofficial Guide to the OSHA1 Stairways and Ladders.
Walking-Working Surfaces
1 Telecom Cabling Ladder safety. 2 OSHA Office of Training & Education ation Telecom Cabling Stairways and Ladders.
Walking-Working Surfaces
FIRE DESIGN OF BUILDINGS VULNERABLE GROUPS. COMPONENTS OF FIRE building materials unattended stoves Loose electrical connections overloaded electrical.
FIRE ESCAPE Christina Joy Chambers IND 5615 Fall 2011.
STAIRS AND STAIR FRAMING
PERFORMANCE & CODE ANALYSIS TIMBer Inc. ·Brooke Fedder · Marie Rottschaeffer· Izzie Molinuevo· Tena Pettit·
Building Codes and Interior Design
© 2008 Delmar, Cengage Learning Property Security, Emergency Response, and Fire Protection Systems Chapter 13.
Means of Egress Chapter 4.
Code Analysis. Identify the relevant codes  Local building code  Local accessibility code (or ADA)  Local fire code (or the NFPA)  Mechanical, electrical.
Fire Safety By Alicia Civile and Alexandra Fernandez.
Decoded 3 – Egress and Life Safety Audio: , Code: Mute your phone (*6 to mute, #6 to unmute) This webinar is being recorded.
ID 440: Project 1: Hospitality Design
The Essentials of Egress
INTD 51 human environments building code. building codes deal with almost every area of building planning, design & construction they are very complex.
Picking up from last week…. Fire stair layout Fire stair layout Due October 18 th Due October 18 th Assignment #1.
Chapter 5 ID 234 Building Codes Fire Resistant Materials and Assemblies.
ID 234 Building Codes Fall 2012 Means of Egress Chapter 4.
BUILDING CODES AND ADA/TAS. BUILDING CODES - EGRESS.
OSHA Office of Training and Education 1 Walking-Working Surfaces.
ID 234 Building Codes Fall 2012 Vertical Components of Egress.
Codes.
Codes and costing construction + materials II. Building Code (780 CMR) Building Code (780 CMR) Accessibility Code (521 CMR) Accessibility Code (521 CMR)
1 Ideas Board “Inspiration From Those Who Have Inspired”
Means of Egress Chapter 3 Part 1: Stairs ID 234 Building Codes
ID 234 Building Codes Fall 2011 Means of Egress Chapter 3, part II.
Chapter 4 ID 234 Building Codes Fall 2011 Means of Egress.
Fire Safety By Alicia Civile and Alexandra Fernandez ASSIGNMENT 4.
Work Area Method Level 3 Alterations – Chapter 9 prescribes requirements. 50% of Building Area Rule.
Mayor’s Office on Disability City and County of San Francisco Discussion of Common Design and Construction Errors.
Exercise #2 (part 2) Based on what you read in Chapter 4, determine if the corridors and exit doors meet the requirements for egress width, according to.
OSHA Office of Training & Education
2009 IBC Egress Issues in Commercial Buildings, May 25, 2011
2015 NSBOA code updates Part 9 and Part 3.
Means of Egress Chapter 3 Part 1: Stairs ID 234 Building Codes
Q1. Name one function of a stairs?
Chapter 2 Building Occupancy
GCSE Construction & The Built Environment
ARCHITECTURAL SAFETY FEATURES –Exit Separations –Continuation of Exit Stairs from lower to upper floors –Discharge from Exits FIRE PROTECTION FEATURES.
Straight run stairs A stairway that has no turns..
Building standards Mr. Da Silva.
LIFT,ESCALATOR AND MOVING WALKS
Presentation transcript:

Means of Egress Part 3 Chapter 4

Exit Accesses: portion of means of egress that leads to an exit. Doors Stairs Ramps Corridors Aisles & Accessways

Exit Accesses: portion of means of egress that leads to an exit. Doors: 32” clear inside width (36” door) Swings in direction of travel, but cannot reduce stir landing dimensions or corridor width by more than 7” when fully open Increase swing of door Create an alcove Enlarge the landing Possibly use sliding door Must meet ADA guidelines Less than 50 occupants – door can swing into the space Thresholds must be same elevation as finished floor or within ½” Transition must be beveled if between ¼” and ½” (ADA, ICC/ANSI)

Exit Accesses: portion of means of egress that leads to an exit. Stairs: Exit access stairs are not the same as exit stairs Exit access stairs: located when one tenant is located on multiple floors of a building or when there is a mezzanine within a space All stairs must meet a set of code requirements Treads & risers Top & bottom landings Handrails Typically required on both sides, and extend beyond the top & bottom of the stairway with an un-interrupted grip Guards Railings used to prevent people from falling off when there are changes in elevation (over 30”) Typically 42” high – must be mounted at required height for a handrail

Exit Accesses: portion of means of egress that leads to an exit. Ramps: Slope ratio: maximum ratio = 1:12 1 unit vertical distance to 12 units horizontal distance 36” wide, typically, measured to inside of handrail Handrail & guard requirements are similar to stairs Width & clearance requirements are similar to corridors Landings: allow for 60” turn-around Typically required every rise of 30”

Exit Accesses: portion of means of egress that leads to an exit. Corridors: required to be enclosed 44” width minimum, but is dependant on codes for specific occupancy classification/load

Exit Accesses: portion of means of egress that leads to an exit. Aisles & Aisle Accessways: created by furniture or equipment Moveable or fixed seating/furniture

Exits: Located at the end of an exit access, it is fully enclosed & rated. Exterior Exit Door Exit Stairs Most common type of exit – must be constructed of rated assemblies Doors must swing in direction of exit discharge Horizontal Exits Protected exit to a safe area of refuge – no change in level Exit Passageways Type of horizontal passage or corridor that provides the same level of protection as an exit stair

Areas of Refuge Where one or more people can wait safely for assistance during an emergency Required to be enclosed by fire and/or smoke partitions Most common requirement: one space for every 200 occupants Typically 30” x 48” If using NFPA & LSC: areas of refuge are not required if building is sprinklered If using IBC: all buildings are required to have an accessible means of egress Sometimes the jurisdiction of a project includes the requirement of both the IBC and LSC – you may have to consult with a code official

Exit Discharge: part of a means of egress that connects an exit with a public way. Main Lobby Foyer or Vestibule Discharge Corridor Egress Court Small Alley or Sidewalk

Means of Egress Capacity Number of Exits Refer to Tables in textbook & previous lectures 2. Exit Widths Refer to Table 1005.1 and additional requirements (on next slide) 3. Arrangement of Exits Half-diagonal rule, travel distance, dead-end corridors, common path of travel 4. Signage Exit signs & other signs

Means of Egress Capacity: Exit Widths Minimum clear door widths: Inside dim of 32”(standard 36” door) Maximum door widths: No more than 48” per door leaf (must spec more than one door) More than one exit: Can affect width of exit access (OL /# of exits) Minimum exit discharge widths: Exit discharge width cannot be less than width of the exit it leads from Minimum corridor widths: Never less than 36”, typical minimum is 44”-48” Exiting from basement: Ground floor OL is increased to reflect basement OL to allow for exiting Minimum horizontal exit sizes: Horizontal areas of refuge must be large enough to hold own occupants plus those from the “fire side” Unobstructed paths: Non-structural wall applications <1/2”, wall sconces & other devices <4”, doors <7” 50 percent rule: Expected loss of any one exit location cannot reduce the total capacity of the exit width by more than 50% Aisles & aisle accessways: 36”-44” minimum width

Signage Exit signs Typically required whenever a floor or space has two or more exits Must be located at doors of all stair enclosures, exit passageways, horizontal exits, all exterior exit doors, & any space where the direction of egress in unclear Typically, no point within the exit access can be more than 100’ from the nearest visible sign Refer to building codes, LSC, ADA, and NFPA 170