Credit: Baughman et al., Science 297, 787 (2002).

Slides:



Advertisements
Similar presentations
Physics Review #1 LCHS Dr.E. A positive test charge is placed between an electron, e, and a proton, p, as shown in the diagram below. When the test charge.
Advertisements

Current Current is defined as the flow of positive charge. I = Q/t I: current in Amperes or Amps (A) Q: charge in Coulombs (C) t: time in seconds.
Multimeter Notes. MultimeterWhat is it? Two types: 1.) 2.) A device that can measure “multiple” properties of a circuit. Ammeter Voltmeter.
CLASS :- X MADE BY :- MANAS MAHAJAN
Dynamic Presentation of Key Concepts Module 2 – Part 3 Meters Filename: DPKC_Mod02_Part03.ppt.
Current and Resistance
Current, Resistance,Voltage Electric Power & Energy Series, Parallel & Combo Circuits with Ohm’s Law, Combo Circuits with Kirchoff’s Laws Review for Chapters.
Series and Parallel Circuits
Electricity Current Electricity.
Ch. 23 Series and Parallel Circuits Milbank High School.
Unit 6 Series Circuits.
Electricity Define electric potential difference Determine the change in potential energy when a charge moves between two points at different.
Electric Circuits.
Friday, February 4 th, 2011 Introducing Current and Direct Current Circuits.
Physics Review #1 LCHS Dr.E. What is the voltage? 12Ω 36V 6Ω 2Ω 2Ω.
Current Electricity. How is current produced? When a high potential is connected by a conductive material to a low potential. When a high potential is.
1. Complete the following circuit diagram to show the two light bulbs in parallel to each other, connected to the 12 V battery. 2. Marty placed a voltmeter.
Part 1 Current & Energy Transfer Electric Current.
Physics 12 Circuits 4 – Parallel Mr. Jean. The plan: Video clip of the day Series Circuits –Mini-Lab - Series Parallel Circuits:
Electric Current and Direct- Current Circuits
1 HVACR216 - Hydronics Basic Circuits and Ohms Law.
CLASS :- X MADE BY :- MANAS MAHAJAN SCHOOL :- K.V. GANESHKHIND PUNE-7
Electrical Resistance Electrical resistance is a measure of how difficult it is for electricity (electrons) to flow through a material. The units of resistance.
November 4, 2013 Topic: Electric Circuit Objectives:
Engineering Science EAB_S_127 Electricity Chapter 2.
Circuit Basics and Ohms Law. Types of Circuits There are two basic types of circuits SeriesParallel.
Current flow versus Electron flow Conventional current flows this way. Electrons flow this way.
Measuring Voltage and Current Aims Know the units of voltage and current Know how to measure voltage and current.
Physics 12 Circuits 3 – Series Mr. Jean. The plan: Video clip of the day Power Series Circuits Resistance in Series Application of Ohm’s Law.
Physics 12 Mr. Jean April 2 nd, The plan: Video clip of the day Chapter 12 & 14 Voltage Power Series Circuits Resistance in Series Application of.
Circuit Basics & Series Circuits Aim: How are circuits designed and connected?
Electricity and Circuit. Types of Electricity Static Electricity – no motion of free charges Current Electricity – motion of free charges – Direct Current.
Series and Parallel Circuits
The flow of charged particles charged particles ; through a conducting metal.
Electric Power Power is the rate that work is done or energy is transferred, that is Power = Power is measured in Watts, W.
Physics 12 Mr. Jean April 10 th, The plan: Video clip of the day Power Series Circuits Resistance in Series Application of Ohm’s Law.
 To interpret and construct electrical circuit diagrams.  To identify series and parallel arrangements of elements.  To calculate the equivalent resistance.
Meters in a Circuit Voltmeter – a device used to measure potential difference across a circuit. Connect outside the direct path of the current (parallel.
Series and Parallel Circuits
Current, Resistance,Voltage Electric Power & Energy Series, Parallel & Combo Circuits with Ohm’s Law, Combo Circuits with Kirchoff’s Laws Review for Chapters.
How do we measure current and potential difference (voltage) in a circuit? HW:
Electricity and Circuit
Measurements in Electric Circuits
through a conducting metal
Series Circuit.
Current Electricity.
EDEXCEL IGCSE PHYSICS 2-4 Electrical Resistance
Measurements in Electric Circuits
Resistors in Series and Parallel
Electric Circuits & Problem Solving!
Be able to describe what resistance is and calculate it.
Resistance Chapter 23.
ELECTRICAL CIRCUITS All you need to be an inventor is a good imagination and a pile of junk. -Thomas Edison.
Ammeter and Voltmeter.
Topic H: Electrical circuits
Series and parallel circuits
THE RESISTOR Forward characteristic Reverse characteristic Circuit.
Ammeter and Voltmeter.
IB Physics SL Y2 Friday, September 19, 2014
Series Circuits: Other examples:.
Electric Circuits IB Physics SL Y2 Friday, September 19, 2014
Series Circuits: Other examples:.
Electric Circuits AP Physics B.
Circuits Current Resistance & Ohm’s Law
Draw the symbols for the below components: Cell: Battery:
Series and Parallel Circuits
Components of an Electrical Circuit
Measuring Voltage Drop and Current
9.1 Series and Parallel Circuits
Presentation transcript:

Credit: Baughman et al., Science 297, 787 (2002)

The four point electrical probe is a very versatile device used widely in physics for the investigation of electrical phenomena. Colorado Superconductor Inc. has especially designed two four point superconducting devices from the YBa2Cu3O7 and the Bi2Sr2Ca2Cu3O10 materials for such investigations. The Complete Exploration Kit and the Super Exploration Kit contain four point electrical probes.Complete Exploration KitSuper Exploration Kit

When a simple measurement of the electrical resistance of a test sample is performed by attaching two wires to it, one inadvertently also measures the resistance of the contact point of the wires to the sample. Typically the resistance of the point of contact (called contact resistance) is far smaller than the resistance of the sample, and can thus be ignored. However, when one is measuring a very small sample resistance, especially under variable temperature conditions, the contact resistance can dominate and completely obscure changes in the resistance of the sample itself. This is the situation that exists for superconductors.

The effects of contact resistance can be eliminated with the use of a four point probe. A schematic of a four point probe is shown in figure 2 below. In this diagram, four wires (or probes) have been attached to the test sample. A constant current is made to flow the length of the sample through probes labeled 1 and 4 in the figure. This can be done using a current source or a power supply as shown. Many power supplies have a current output readout built into them. If not, an ammeter in series with this circuit can be used to obtain the value of the current. A 5 Watt power supply capable of producing up to 0.5 Amp is required for the experiments described for our superconducting devices. I

The effects of contact resistance can be eliminated with the use of a four point probe. A schematic of a four point probe is shown in figure 2 below. In this diagram, four wires (or probes) have been attached to the test sample. A constant current is made to flow the length of the sample through probes labeled 1 and 4 in the figure. This can be done using a current source or a power supply as shown. Many power supplies have a current output readout built into them. If not, an ammeter in series with this circuit can be used to obtain the value of the current. A 5 Watt power supply capable of producing up to 0.5 Amp is required for the experiments described for our superconducting devices.

If the sample has any resistance to the flow of electrical current, then there will be a drop of potential (or voltage) as the current flows along the sample, for example between the two wires (or probes) labeled 2 and 3 in the figure. The voltage drop between probes 2 and 3 can be measured by a digital voltmeter. The resistance of the sample between probes 2 and 3 is the ratio of the voltage registering on the digital voltmeter to the value of the output current of the power supply. The high impedance of the digital voltmeter minimizes the current flow through the portion of the circuit comprising the voltmeter. Thus, since there is no potential drop across the contact resistance associated with probes 2 and 3, only the resistance associated with the superconductor between probes 2 and 3 is measured.

The four point probe devices in the Complete Exploration Kit and the Super Exploration Kit are both encapsulated in rugged brass casings. On one side of the casing, the superconductor disk is visible. An aluminum end cap has been inserted on the back side of the brass casing to seal and to protect the probe connections with the superconductor. Please do not attempt to remove the end cap. A matched thermocouple has also been attached to the superconductor in this casing. This thermocouple is a type 'T'.Complete Exploration KitSuper Exploration Kit

The effects of contact resistance can be eliminated with the use of a four point probe. A schematic of a four point probe is shown in figure 2 below. In this diagram, four wires (or probes) have been attached to the test sample. A constant current is made to flow the length of the sample through probes labeled 1 and 4 in the figure. This can be done using a current source or a power supply as shown. Many power supplies have a current output readout built into them. If not, an ammeter in series with this circuit can be used to obtain the value of the current. A 5 Watt power supply capable of producing up to 0.5 Amp is required for the experiments described for our superconducting devices. If the sample has any resistance to the flow of electrical current, then there will be a drop of potential (or voltage) as the current flows along the sample, for example between the two wires (or probes) labeled 2 and 3 in the figure. The voltage drop between probes 2 and 3 can be measured by a digital voltmeter. The resistance of the sample between probes 2 and 3 is the ratio of the voltage registering on the digital voltmeter to the value of the output current of the power supply. The high impedance of the digital voltmeter minimizes the current flow through the portion of the circuit comprising the voltmeter. Thus, since there is no potential drop across the contact resistance associated with probes 2 and 3, only the resistance associated with the superconductor between probes 2 and 3 is measured. The four point probe devices in the Complete Exploration Kit and the Super Exploration Kit are both encapsulated in rugged brass casings. On one side of the casing, the superconductor disk is visible. An aluminum end cap has been inserted on the back side of the brass casing to seal and to protect the probe connections with the superconductor. Please do not attempt to remove the end cap. A matched thermocouple has also been attached to the superconductor in this casing. This thermocouple is a type 'T'.Complete Exploration KitSuper Exploration Kit