12. 02. 2014 Sub-percent polarization accuracy for the P2 experiment at MESA Eucard-II workshop „Spin-Optimization at Lepton accelerators“ Kurt Aulenbacher.

Slides:



Advertisements
Similar presentations
Extraction of G E n at Q 2 =1 (GeV/c) 2 by Measurements of May 1, 2011 Ge Jin University of Virginia.
Advertisements

Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky College of William and Mary, Williamsburg VA Experimental Overview The.
Measuring the Neutron and 3 He Spin Structure at Low Q 2 Vincent Sulkosky for the JLab Hall A Collaboration College of William and Mary, Williamsburg VA.
Jin Huang PhD Candidate, MIT For MENU 2010 May 31, Williamsburg.
1 First Measurement of the Structure Function b 1 on Tensor Polarized Deuteron Target at HERMES A.Nagaitsev Joint Institute for Nuclear Research, Dubna.
Patricia Aguar Bartolomé Institut für Kernphysik, Universität Mainz PSTP 2013 Workshop, Charlottesville 11th September 2013.
Patricia Aguar Bartolomé, Kurt Aulenbacher, Valery Tioukin, Jürgen Diefenbach Institut für Kernphysik, Universität Mainz PAVI’14, Syracuse, NY 17th July.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
1 Electron Beam Polarimetry for EIC/eRHIC W. Lorenzon (Michigan) Introduction Polarimetry at HERA Lessons learned from HERA Polarimetry at EIC.
EPAC June 2003 The EPAC June 2003 Questions 1. Clarify the Motivation for the Proposal. 2. How to ensure the e+ polarimeter works right away? 3. What is.
DESY PRC May 10, Beyond the One Photon Approximation in Lepton Scattering: A Definitive Experiment at DESY for J. Arrington (Argonne) D. Hasell,
K. LaihemE166 collaboration LCWS06 Bangalore March 12th 2006 The E166 experiment Development of a polarized positron source for the ILC. Karim Laihem on.
Parity Violation in Electron Scattering Emlyn Hughes SLAC DOE Review June 2, 2004 *SLAC E122 *SLAC E158 *FUTURE.
Proton polarization measurements in π° photo-production --On behalf of the Jefferson Lab Hall C GEp-III and GEp-2γ collaboration Wei Luo Lanzhou University.
AESOP: Accurate Electron Spin Optical Polarimeter Marcy L. Stutzman, Matt Poelker; Jefferson Lab Timothy J. Gay; University of Nebraska.
Precision Electron Beam Polarimetry Wolfgang Lorenzon (Michigan) SPIN 2008 Symposium 6-October 2008.
DIS 2006 TSUKUBA April 21, 2006 Alessandro Bravar Spin Dependence in Polarized Elastic Scattering in the CNI Region A. Bravar, I. Alekseev, G. Bunce, S.
Beijing, Feb 3 rd, 2007 LEPOL 1 Low Energy Positron Polarimetry for the ILC Sabine Riemann (DESY) On behalf of the LEPOL Collaboration.
20/05/06 Special requirements for Photosources operating at PV electron scattering exp. International Workshop PAVI 2006 Milos Island 20/05/2006 by Kurt.
Polarimetry of Proton Beams at RHIC A.Bazilevsky Summer Students Lectures June 17, 2010.
Beijing, Feb 3 rd, % e+ Poalarization 1 Physics with an initial positron polarisation of ≈30% Sabine Riemann (DESY)
25/07/2002G.Unal, ICHEP02 Amsterdam1 Final measurement of  ’/  by NA48 Direct CP violation in neutral kaon decays History of the  ’/  measurement by.
A study of systematic uncertainties of Compton e-detector at JLab, Hall C and its cross calibration against Moller polarimeter APS April Meeting 2014 Amrendra.
Polarimetry at the LC Source Which type of polarimetry, at which energies for LC ? Sabine Riemann (DESY), LEPOL Group International Workshop on Linear.
Compton polarimetry for EIC Jefferson Lab Compton Polarimeters.
Energy calibration at LHC J. Wenninger. Motivation In general there is not much interest for accurate knowledge of the momentum in hadron machines. 
Systematic Errors Studies in the RHIC/AGS Proton-Carbon CNI Polarimeters Andrei Poblaguev Brookhaven National Laboratory The RHIC/AGS Polarimetry Group:
The A2 recoil nucleon polarimeter  Daniel Watts University of Edinburgh, UK.
» Absolute Polarimetry of Proton Beams at RHIC« Oleg Eyser for the RHIC Polarimetry Group International Workshop on Polarized Sources, Targets and Polarimetry.
May 17, 2006Sebastian Baunack, PAVI06 The Parity Violation A4 Experiment at forward and backward angles Strange Form Factors The Mainz A4 Experiment Result.
1 Overview of Polarimetry Outline of Talk Polarized Physics Machine-Detector Interface Issues Upstream Polarimeter Downstream Polarimeter Ken Moffeit,
Polarisation monitoring Sabine Riemann, Andreas Schälicke, Andriy Ushakov (DESY) Positron Source Group Meeting, October, 2009 University of Durham.
G E p -2γ experiment and the new JLab Hall-C Focal Plane Polarimeter Mehdi Meziane The College of William & Mary - APS Meeting April 14, On behalf.
Summary of Workshop on Precision Electron Beam Polarimetry Newport News June 9-10, 2003 workshop summary by Dave Gaskell, Jefferson Lab Richard Jones,
Vina Punjabi Norfolk State University Hall A Collaboration Meeting June 10-11, 2010 GEp-V Experiment to Measure G Ep /G Mp.
Polarimetry Report Sabine Riemann on behalf of the DESY/HUB group January 24, 2008 EUROTeV Annual Meeting, Frascati.
Lecture 9: Inelastic Scattering and Excited States 2/10/2003 Inelastic scattering refers to the process in which energy is transferred to the target,
Proton Charge Form Factor Measurement E. Cisbani INFN Rome – Sanità Group and Italian National Institute of Health 113/Oct/2011E. Cisbani / Proton FF.
TENSOR POLARIZED DEUTERON BEAM AT THE NUCLOTRON Yu.K.Pilipenko, V.P.Ershov, V.V.Fimushkin, A.Yu.Isupov, L.V.Kutuzova, V.P.Ladigin, N.M.Piskunov, V.P.Vadeev,
COMPASS polarized target for Drell-Yan Michael Pesek Charles University in Prague On behalf of COMPASS PT group PSPT, Charlottesville, Virginia
The NPD  Experiment David Bowman IScientific goals IIStatus.
A. Zelenski a, G. Atoian a *, A. Bogdanov b, D.Raparia a, M.Runtso b, D. Steski a, V. Zajic a a Brookhaven National Laboratory, Upton, NY, 11973, USA b.
Fast or slow positron spin flipping Sabine Riemann (DESY) November 17, 2008 ILC08, University of Illinois - Chicago.
GEp-III in Hall C Andrew Puckett, MIT On behalf of the Jefferson Lab Hall C GEp-III Collaboration April 15, 2008.
Possibility of direct extraction of the transversitiy from polarized Drell-Yan measurement in COMPASS Transversity Drell-Yan for transverstiy transverse.
N. Poljak, FPD++ N. Poljak, U. of Zagreb.
Moller Polarimeter Q-weak: First direct measurement of the weak charge of the proton Nuruzzaman (
Single-spin asymmetry in interference fragmentation on a transversely polarized hydrogen target at HERMES Tomohiro Kobayashi Tokyo Institute of Technology.
Run Time, Mott-Schwinger, Systematics, Run plan David Bowman NPDGamma Collaboration Meeting 10/15/2010.
Inclusive cross section and single transverse-spin asymmetry of very forward neutron production at PHENIX Spin2012 in Dubna September 17 th, 2012 Yuji.
G0 Backward Angle Request: Q 2 = 0.23, 0.48 GeV 2 Main points G0 goal is to measure G E s, G M s and G A e over range of momentum transfers with best possible.
Thomas Jefferson National Accelerator Facility Operated by the Southeastern Universities Research Association for the U.S. Depart. Of Energy The Department.
RHIC pC Polarimeters in Run9: Performance and Issues A.Bazilevsky for the RHIC CNI Group Polarimetry Worshop BNL, July 31, 2009.
Thomas Jefferson National Accelerator Facility Precision Electron Beam Polarimetry Workshop - June , Jefferson Laboratory Accelerator Tools.
Overview of recent photon beam runs at CLAS CLAS12 European Workshop, Feb , Genoa, Italy Ken Livingston, University of Glasgow Tagged photons.
The Polarimeter chain for the MESA-PV experiment PAVI2011, ROME Kurt Aulenbacher for the B1,B2 and A4 collaborations at IKP Mainz.
Pb-Parity and Septum Update Presented by: Luis Mercado UMass - Amherst 12/05/2008 Thanks to Robert Michaels, Kent Pachke, Krishna Kumar, Dustin McNulty.
Status of Polarimeters and Polarized Targets: what are the plans for development of polarized targets to meet the needs of the Day 1 and future experimental.
A.P. Potylitsyn, I.S. Tropin Tomsk Polytechnic University,
University of Michigan
Accelerator Issues Raised in Hall A Parity Collaboration Meeting, April B-Team Meeting April 29, 2009.
The MESA-Project and itS electron Polarimeters
Larisa Nogach Institute of High Energy Physics, Protvino
A Precision Measurement of GEp/GMp with BLAST
Progress on J-PARC hadron physics in 2016
Special Considerations for SIDIS
Wei Luo Lanzhou University 2011 Hall C User Meeting January 14, 2011
Recent results from BLAST detector
GEp-2γ experiment (E04-019) UPDATE
Measurement of Parity-Violation in the N→△ Transition During Qweak
Presentation transcript:

Sub-percent polarization accuracy for the P2 experiment at MESA Eucard-II workshop „Spin-Optimization at Lepton accelerators“ Kurt Aulenbacher for the P2 collaboration at IKP Mainz Eucard-II workshop 1

Outline The P2 experiment at Mainz How to achieve  P/P <0.5%? The chain: DSP/Vector-Monitor/Hydro-Möller Present and future: Test-beamline and schedule Eucard-II workshop 2

P2-experiment: Accurate measurement of  W LHeC workshop Unfortunately: A~Q 2 (for Q 2 <<Mz)  This experiment is simple, but not easy: Scattering Asymmetry is ~2*10 -8 D. Becker, AIP Proceedings Vol 1563 (2013 ) Electroweak interference:  W first measured by: Prescott et al. Phys. Lett. B. 77 p.347 (1978) Asymmetry in Prescott et al. :1*10 -4 P2 is (almost) Prescott 2

P2-experiment 150  A Beamcurrent, 60cm lq. H2, Beampol: 85%.  h Data-taking Extremely high demands on control of HC-fluctuations! & High accuracy polarization measurement (  P/P=0.5% !!) LHeC workshop Precision determination of electroweak mixing angle co-motivates funding of a new Accelerator: The MESA project

MESA-Hall-1 MESA-Hall-2 Shielding Experimental Hall High power beam dump Shaft building MESA: A new accelerator at KPH-Mainz Eucard-II workshop 5 MESA -No new buildings necessary -MAMI continues separately for hadron structure exp. ~1GeV scale -MESA takes over “low energy” experiments ~100MeV scale Design of MESA machine ongoing Commisioning foreseen 2017

MESA& MAMI: existing Polarimeters Eucard-II workshop 6 A1 Möller A2 Möller Mott-Polarimeter 3.5 MeV A4 Laser-Compton: Very low asymmetry at MESA Energies!

Existing Electron-Polarimeter chain at MAMI What about Mott/Möller systematics? -A2-Möller-target: in plane magnetization: Target Polarization may cause problem -A1- Möller-target: perpendicular magnetization, saturated in 4T B-field - Möller-error sources: PTarget, acceptance corr, Levchuk effect,…  2-5 % relative error -Mott error sources: radiative corrections to analyzing power, analyzing power dilution, background,….  2-5% relative error. Eucard-II workshop 7 V. Tioukine, K. Aulenbacher, (BMBF-Spin-Management) AIP Conference Proceedings 1563, 276 (2013); doi: / PolarimeterEnergy [MeV] Pol. [%] ± (stat. only) Mott3.587,6±0.5 A1-Möller ±0.8 A1-Möller ±0.6 A2-Möller150873,2±1.8 Due to high multiplicity of error sources it will be hard to improve existing polarimeters to < 1% accuracy, 0.5% presently not realistically achievable.

MESA& experiments Eucard-II workshop PV PIT 8 NEW POLARIMETERS ARE REQUIRED!

MESA& planned Polarimeter chain Polarimeter 1: „Conventional“ Vector-Polarization-Monitor (5 MeV) PV Polarization Drift consistently observed in transverse AND longitudinal observable at the <0.5% level Photon-Transmission Asymmetry through magnetized „Compton-Absorber“ Measures: longitudinal Spin component Sketch of Mott-Polarimter with double focusing magnet spectrometers Measures: transverse Spin component P-Vector Circular polarized  ‘s: P  ~P long (to absorber ) Primary beam Mott scattered e‘s: A ~P trans

Vector Monitor capabilities Simultaneous measurement: Polarization Drift consistently observed in transverse AND longitudinal observable at the <0.5% level Stability: R. Barday et al J. Phys. Conf. Ser PEB workshop Boston 10 V. Tioukine et al. Rev. Sc. Instrum (2011 ) Dynamic Range: Demonstration of constant polarization over large interval in intensities P-Vector Circular polarized  ‘s: P  ~P long (to absorber ) Primary beam Mott scattered e‘s: A ~P trans

MESA polarimeter chain Eucard-II workshop PV 2 Minimal-invasive online polarimeter (  P/P ≤ 0.5%) „Hydro-Möller“ 3Invasive „Double-scattering-Polarimeter“ (DSP) (  P/P ≤ 0.5%) (operates at source energy) Polarimeter 1 will monitor the polarization and LINK the two other polarimeters which operate at different intensity levels 11

Why is it so difficult to obtain high accuracy ? Conventional Polarimeter : Eucard-II workshop 12 Two cases: Single spin asymmetry /double spin asymmetry

“Unconventional” Polarimeters at MESA Eucard-II workshop PV 2 Minimal-invasive online polarimeter (  P/P ≤ 0.5%) „Hydro-Möller“ 3 Invasive „Double-scattering-Polarimeter“ (DSP) (  P/P ≤ 0.5%) I „Hydro Möller“ will eliminate Problem of Target Polarization measurement and give remedy for (almost) all other systematics in Möller polarimetry II „DSP“ will eliminate the problems of determining S eff altogether III Both will be checked against each other The Promise(s):

What is Polarimeter 2: „Hydro Möller“ ? Eucard-II workshop 14

In a field gradient a force  Pulls into the strong field  Repels out of the field High rate recombination (releasing ~ 4.5 eV) at low T ?  Gas: 2-body kinematic suppression  Gas: 3-body density suppression  Surface cell walls coated with approx 50 nm of superfluid Density 1-  % polarization of the electrons  ~10 -4 Storage Cell

Hydro-Möller Chudakov&Luppov, Proceedings IEEE Trans. Nucl. Sc. 51, 1533 (2004) ~1m + measurement is non-invasive and + provides sufficient statistical accuracy at the beam current level of the PV experiment + Complete Target polarization (similar to Laser-Compton) + no Levchuk effect -: immense technical effort -: atomic trap has never seen beam Eucard-II workshop 16 „Prototype“ of atomic trap was donated to us by UVA/Don Crabb  Template for cryostate development

-Dilution refrigerator and magnet where used at BNL for Prototyping of polarized proton beam source in 1990’s - Shipped from UVA to Mainz (2011) Refrigerator unfortunately “not refurbishable” T = 300 mK of the atomic trap achieved by using a 3He/4He Dilution Refrigerator

KPH can & will build a “copy” of BNL cryostat -1K tests in mK ~30mW in Trap operational and in beam 2018 Open questions: 1.) Beam dynamics 2.) Detection System & 300mK-power req. 3.) Sustain Helium Film? 4.) Beam induced de-polarization? 5.)... After long and thourough reverse engineering &discussions with collegues from Dubna, UVA and JLAB we arrive at the following conclusions: Correlated Möller pair, 75MeV with up ~1 Cyclotron rotation in 8T field BPM‘s Steerers Feedback 150 MeV beam to PV-Exp also 1 cyclotron rot.

Systematics of extrapolated to 10000h of data taking: ~0.4ppb/10000h ~2.5ppb/10000h ~0.05ppb/10000h beam position y beam current beam angle y beam position x beam angle x beam energy Required uncertainty 0.1ppb: Really possible to improve position fluctuations in presence of strong field and short lever arms?  TEST IT

Problems of the Hydro Möller Eucard-II workshop PV 2 Minimal-invasive online polarimeter (  P/P ≤ 0.5%) „Hydro-Möller“ Is stable „Parity Quality“ operation really achievable with 8T magnet in beamline and a low energy of 150 MeV? -Longer lever arms for stabilization systems required?  Get answer now! Use 180 MeV beam from MAMI-A!

Hydro-Möller-Mock-up-magnet (3T, available). Objective: Demonstrate Parity quality while transmitting through strong field in front of P2 ! Three topics: two additional fast WEDL pairs one additional slow WEDL pair four additional XYMOs Objective: Demonstrate P2-Parity quality beam Long and short lever arms!

What about Polarimeter 3 ? Eucard-II workshop PV 3 Invasive „Double scattering“ polarimeter (  P/P ≤ 0.5%) In contrast to Polarimeter 2, this one already exists - Small device, testing possible at existing MESA-source -Double scattering Polarimeter makes S eff measurable What is the working principle?

Polarimeter 3 A.Gellrich and J.Kessler PRA (1991) Eucard-II workshop 23 The apparatus of Gellrich & Kessler is in our possesion Goal:-1 Reproduction of Kesslers claims using test source Measurements have started in summer 2013, see talk by M. Molitor

Conclusions Eucard-II workshop PV 1 Vector-Monitor-Polarimeter 2Minimal-invasive online polarimeter (  P/P ≤ 0.5%) „Hydro-Möller“ 3Double scattering polarimter (  P/P ≤ 0.5%) Ambitious polarimetry concept with probably several not yet discovered pitfalls Ambitioned MESA-Polarimetry team is at work: Thanks to: P. Aguar, M. Bruker, J. Diefenbach, T. Stengler, M. Molitor, V. Tioukine, Fruitful and continuing discussions with many people and institutions! Thanks to: V. Borisov, V. Usov (DUBNA), D. Crabb (UVA) D. Keith (JLAB), W. DeKoninck (William and Mary) and many more

More remarks DSP works at ~100keV; ideal for ‚1mA-MESA-stage-1 Targets not extremely thin (~100nm) Elimination of apparatus asymmetry depends critically on geometrical arrangement of normalization counters Apparatus calibrates S eff, but does not allow to measure S 0 Claim: Inelastic contributions do not jeopardize the accuracy! potential issues  how to use with polarized beam?  What if the two targets are NOT identical? Hopster&Abraham (1989): No problem, If a switchable polarized beam is available (|P+|=|P-|), the first target may then be treated as an auxiliary target which may be exploited for systematic cross checks Eucard-II workshop 25

HopsterAbraham/Kessler Method 5 equations with four unknowns  consistency check for apparative asymmetries!  Results achieved by Kessler were consistent <0.3% S. Mayer et al Rev. Sci. Instrum (1993) Eucard-II workshop 26

low and a high energy polarimeter cross-check: negl. depolarization due to low energy gain of MESA Monitoring, stability and cross calibration can be supported by extremely precise Mott/Compton combination. Hydro Möller + DSP may obtain  P/P <0.5 % each, Conclusion: Eucard-II workshop 27