Manual Density Business Today

Slides:



Advertisements
Similar presentations
Heating, Ventilation, and Air-Conditioning (HVAC) Systems
Advertisements

FLOW measurements.
Refrigerators.
General System Maintenance BUS 4 COMPONENT FLOW.PPT
HVAC523 Soldering.
Ice. Pure and Simple ™ Welcome to the Ice-O-Matic ® on-line training modules.
Installation. Indoor Unit Installation Typical Installation.
Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160 Feb
STEP 1 IN THE ROAD TO UNDERSTANDING CHEMISTRY Measurements & Ratios.
BASICS OF HVAC Ivy Tech Community College. Definitions – Page 862 HVAC systems are made up of the mechanical equipment such as the furnace, air conditioner,
Air Finned Heat Exchanger for Mechanical Seal EXPERT ENGINEERING – MUMBAI, INDIA Air Finned Heat Exchanger for Mechanical Seals - having immense potential.
DR-2000 Customer Benefits Security; Tamper resistant programming protects your customer and you! Low maintenance, long battery life & long squeeze tube.
Reservoirs Covered in Ch. 5 of Vickers Text
HVACR312 - Refrigeration Metering Devices.
Manual Kinematic Viscosity Bath Tamson TV12
Installation and Initial Start Up by Martin Noska, Service Engineer, Aftersales & Service.
Hydraulics.
Experiment (2) Specific gravity determination
Selection of measuring instruments
Kern Method of SHELL-AND-TUBE HEAT EXCHANGER Analysis
Evaporators For Air Conditioning
Fuel Oil Systems Fuel Oil Systems consist of: Storage Tanks Pumps
STEAM HEATING.
Hydraulics For The Long Term
Lease Automatic Custody Transfer
The Cooling System.
AIR QUANTITY REQUIRED TO TRANSFER HEAT IN A FORCED AIR SYSTEM In all four mechanical systems considered, the transfer of heat, either by taking it out.
Learning, our way Examples of bad installation. CONTENT Installation related examples Installation related examples Application related examples Application.
Experiment 7. Thermal Expansivity by Dilatometry and Pycnometry The dilatometer and pycnometer used in this experiment are illustrated here. The dila-
Plan 2 – Dead-end Seal Chamber Optional Jacket
INTRODUCTION Definition:
Installation. Indoor Unit Installation Typical Installation.
T H E U N I N T E R R U P T I B L E P O W E R P R O V I D E R SineWave - Installation rules.
Batteries The purpose of the battery is to act as a reservoir for storing electricity.
Air Handler Terminology
Mercury Spill Response Instrumentation. Mercury Vapor Analyzers Jerome 431-X MVA (gold film) Lumex 915+ MVA (Atomic Absorption) Jerome J405 MVA.
Types of thermometer Fa-2 Science project.
Manual Kinematic Viscosity Bath Tamson TV12LT Viscosity Business Today Testing kerosene Testing diesel Testing lubricants Testing fuel oils Testing.
The Refrigeration Process
Polymer Nanofibers from Recycling of Waste Expanded Polystyrene Research at The University Of Akron C. Shin and G. G. Chase Polymer Nanofibers from Recycling.
Viscosity Business Today
Flammable and Combustible Liquids. Introduction !The two primary hazards associated with flammable and combustible liquids are explosion and fire !Safe.
Experiment 1 Basic Laboratory Techniques Parts A, D, E, and an Unknown
Examination Procedures Goods Sold by Volume
Warm-Up Name the following lab equipment:. General Lab Equipment Different experiments require different types of equipment. Even though experiments differ,
Oil Bath Safety. Oil Bath Use Safety first  Always wear protective eye-wear and gloves.  Do not set the oil-bath temperature.
Viscosity of Bitumen ASTM D2170, EN 12595, ASTM D2171, IP 222, EN 12596, AASHTOT 202 Rev 1.01.
Chapter 39 Cooling System Fundamentals.
EVAPORATION EVAPORATION By: Dr. Tahseen Ismail By: Dr. Tahseen Ismail.
General Laboratory Techniques Dry Lab Chemistry 1105.
2016/6/181 ISO 6540 ISO 6540 (first edition 1980) International Standard Maize – Determination of moisture content (on milled grains and on whole grains.
Flammable Liquids Directorate of Training and Education
EuroCave Cellar Conditioner CL-C. EuroCave cellar conditioners have been designed to preserve your wine in a perfect environment, guaranteeing minimum.
Identification of Substances by Physical Properties.
Viscosity of Bitumen ASTM D2170, EN 12595, ASTM D2171, IP 222, EN 12596, AASHTOT 202 Rev 1.03.
UNICO INVERTER DC. UNICO INVERTER DC UNICO INVERTER DC The first INVERTER technology based heat pump without external unit on the market The new product.
ARAC/H/F Air-cooled water chillers, free-cooling chillers and heat pumps Range: kW.
Chromatography- TLC & HPLC
Thermoforming Process
Manual Set-Up for Density by Hydrometer Method 1.10
ME390 Automotive Mechanics
Hot Water Systems Cylinders and Systems.
SCITEQ End closure series
Presentation transcript:

Manual Set-Up for Density by Hydrometer Method ASTM D1298, D287, D6822 and IP160

Manual Density Business Today The reference method for national metrological institutes and calibration labs. Density of crude oil is difficult to measure automatically and manual measurement is often necessary. Density by hydrometer method is referee method in case of dispute with automatic density meter. Done by labs which run a lot of different sample types at different temperatures.

Content of Presentation The Method ASTM standard D1298* ASTM D1298 Setup Alternative Devices Unit Installation and Preparing *We describe the ASTM D1298 method in this presentation, but our set-up can also be used for ASTM D287 and ASTM D6822. 3

The Method Covers the laboratory determination using a glass hydrometer, of the density, relative density (specific gravity), or API gravity of crude petroleum, petroleum products, or mixtures of petroleum and nonpetroleum products normally handled as liquids, and having a Reid vapor pressure of 101.325 kPa (14.696 psi) or less. Values are measured on a hydrometer at either the reference temperature or at another convenient temperature. 4

The Method Standard Standards ASTM D287, ASTM D1298, ASTM D6822, IP160. The standard describes the manual measurement of density by hydrometer method. (ASTM D6822 describes the thermo hydrometer method). The sample is brought to a specified temperature and a test portion is transferred to a hydrometer cylinder that has been brought to approximately the same temperature. The appropriate hydrometer, also at a similar temperature, is lowered into the test portion and allowed to settle. The hydrometer cylinder and its contents are placed in a constant temperature bath to avoid excessive temperature variation during the test. After temperature equilibrium has been reached, the hydrometer scale is read, and the temperature of the sample is taken. The observed hydrometer reading is reduced to the reference temperature by means of the Petroleum Measurement Tables. 5

The Method Bath Temperature Use a bath with a constant temperature. Temperature should stay within  0.25C of the test temperature. The temperature measuring device is a glass thermometer. Tamson advises ASTM 12C thermometer with a range from -20°C up to +102°C, reference number 25T0911. 6

The Method Hydrometer Hydrometers, of glass, graduated in units of density, relative density, or API gravity as required, conforming to specification E100 or ISO649-1. Hydrometer cylinder, clear glass, plastic (see 6.3.1), or metal. The inside diameter of the cylinder shall be at least 25 mm greater than the outside diameter of the hydrometer and the height shall be such that the appropriate hydrometer floats in the test portion with at least 25 mm clearance between the bottom of the hydrometer and the bottom of the cylinder. 7

Tamson Set-up for D1298 Small footprint. Temperature range. Extremely stable. Heating & cooling. Three positions (six optional). Excellent view of hydrometer. Easy drainage and cleaning. 8

D1298 Set-up Small Footprint Length 36 cm Heigth 80 cm Heigth 57 cm Length 46 mm Width 32 cm Width 27 cm Important: TLC15-5 can be placed to the left side, right side or behind the D1298 set-up. It can even be placed under the workbench. The TLC15-5 has to be placed in a well ventilated area. Air circulation has to be enabled by 30 cm of free space at all sides. 9

D1298 Set-up Temperature Range The TLC15-5 circulator pumps a flow through the double walls of the glass cylinders. Temperature range of TLC15-5 is from -15°C up to +60°C, optional range is from -15°C up to +150°C. This range is much wider than with automatic density devices. Minimum temperature of D1298 set-up approx. +5°C. Maximum temperature depends on the temperature range of TLC15-5, maximum is +150ºC. You can test the density of your sample precisely at the exact temperature. No need for petroleum measurement tables and thus the risk for wrong calculations. 10

D1298 Set-up Extremely Stable ASTM D1298 states that temperature should stay within  0.25C of the test temperature. Our setup easily meets this requirement. Stability @ 15°C 11

D1298 Set-up Extremely Stable ASTM D1298 states that temperature should stay within  0.25C of the test temperature. Our setup easily meets this requirement. Stability @ 20°C 12

D1298 Set-up Extremely Stable ASTM D1298 states that temperature should stay within  0.25C of the test temperature. Our setup easily meets this requirement. Stability @ 5°C Stability @ 60ºC 13

D1298 Set-up Heating & Cooling One of the main advantages of our set-up is that you can use it at different temperatures for different type of samples. When testing at different temperatures quick cooling and heating is important. From ambient to 60ºC only takes 40 minutes. 14

D1298 Set-up Heating & Cooling From 20ºC to 5ºC only takes 70 minutes. 15

D1298 Set-up Three positions (six optional) Setup can be used with three hydrometers at the same time. Optional an additional mounting rack with cylinders can be added to have six positions in total. Spare part number is 00T1260. Six positions set-up shows similar result in stability and heating & cooling capacity. 16

D1298 Set-up Excellent view of hydrometer Conventional systems are using some kind of a thermostatic bath with hydrometers cylinders. Part of the hydrometer cylinders are blocked by the lid of the bath. So, part of the hydrometer can not be read. 17

D1298 Set-up Excellent view of hydrometer Our set-up is using a tripod in which the hydrometer cylinders are mounted. Due to the design, you will have a clear view of the hydrometer cylinder. So, you can easily read the complete hydrometer. 18

D1298 Set-up Easy drainage and cleaning After the sample has been tested, the sample can be easily removed by using the drain. Cylinder can be cleaned with a solvent. In case a portion of the sample is spilled, the tray can be removed and cleaned. Work bench will not get dirty. 19

D1298 Set-up Easy drainage and cleaning TLC15 can be drained by using the drain at the backside of the apparatus. Overflow outlet standard installed. 20

Alternative Devices TC16 + D1298 Set-up When customer is always testing above ambient temperature, e.g. @ 50ºC, and 100ºC. With TC16 temperature range up to +250ºC. 21

Alternative Devices TV2500 When customer is always testing above ambient temperature, e.g. @ 40ºC or 100ºC. Range from ambient up to 120ºC. Can be used with three hydrometer cylinders. Partnumber hydrometer cylinder is DCP-1298-002. Part number for cover with three * Ø 61 mm is 03T2119. Advantage of this TV2500 is that the bath can also be used for kinematic viscosity measurements conforming to ASTM D445. 22

Alternative Devices TV2500 + TLC10-3 Same set-up as in previous sheet. Additional TLC10-3 cooling circulator which can be connected to the cooiling coil of the TV2500. Due to TLC10-3 the range for density measurements will be from +5°C up to 120°C. Set-up can be used for kinematic viscosity & density measurements. 23

Installation Unpack the set-up from the box and remove packing materials. Put the cylinders in the tripod. Connect the silicon tubing which has already been pre cut. Wall outlets should be properly grounded and provide clean power with minimum electrical noise. Be sure to check the power requirements (230V/50Hz, 230V/60Hz, 115V/60Hz) marked on the tag plate at the back side of the bath. Make sure to use the proper bath medium for each operating temperature. Takes approx. 20 minutes to install the set-up.

Maintenance Regularly check the apparatus and condenser unit for dust. Remove dust with a vacuum cleaner. Replace bath fluid regularly in order to keep the cylinders clean.