Introduction The importance of method validation

Slides:



Advertisements
Similar presentations
Tsimillis, K.: Accreditation or Certification for Laboratories?© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality.
Advertisements

Supplementary Training Modules on Good Manufacturing Practices
Quality is a Lousy Idea-
Analytical Method Development and Validation
Instrumental Analysis
1 Method Selection and Development l Initial Considerations n What does the method need to do? 3 What analyte/s need to be assayed? 3 What range or concentration.
Copyright Alan Rowley Associates Steps to an Accurate Result Select a method and validate it as suitable for the purpose envisaged. Establish that.
PHARM 462 PART / /31 Good Manufacturing Practices (GMP) VALIDATION of ANALYTICAL TEST METHODS.
World Health Organization
Accreditation & Validation
Dr Samah Kotb Lecturer of Biochemistry 1 CLS 432 Dr. Samah Kotb Nasr El-deen Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Nasr.
Quality Assurance.
Validation of Analytical Methods
Assuring the Quality of Test and Calibration Results - ISO/IEC – 5.9
Supplementary Training Modules on Good Manufacturing Practice
Types of experimental error
Short Course on Introduction to Meteorological Instrumentation and Observations Techniques QA and QC Procedures Short Course on Introduction to Meteorological.
Technical requirements  Sampling  Analysis  Reporting of the results.
Validation of analytical methods
ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES
QUALITY CONTROL OF PHYSICO-Chemical METHODS Introduction :Validation توثيق المصدوقية.
Lecture 7 Analytical Quality Control
Validation of Analytical Method
Laboratory Validation of Analytical Methods
Dr. Michael Scheutwinkel
Good Laboratory Practice
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 P. HoulgateAssessment of Test Kits in Terms.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
Analytical considerations
Introduction to Analytical Chemistry Dr M. Abd-Elhakeem Faculty of Biotechnology General Chemistry Lecture 7.
Author: TitelKaus, R., Nagel, T.: Calibration and Detection Limits© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality.
Quality WHAT IS QUALITY
American Association for Laboratory Accreditation Practical Solutions to Traceability and Uncertainty in Accreditation Presented to CITAC-NCSLI Joint Workshop.
How to Select a Test Method Marlene Moore Advanced Systems, Inc. June 15, 2010.
Chapter 5 Errors In Chemical Analyses Mean, arithmetic mean, and average (x) are synonyms for the quantity obtained by dividing the sum of replicate measurements.
Measurement Uncertainty Information in
Quality Control Lecture 5
Laboratory QA/QC An Overview.
Wenclawiak, B.: Glossary of Analytical Chemistry Terms© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance.
Koch, M.: Control Charts© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training.
Quality Assurance How do you know your results are correct? How confident are you?
Williams, A.: Measurement Uncertainty© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical.
5. Quality Assurance and Calibration Quality assurance is We do to get the right answer for our purpose. Have Sufficient accuracy and precision to support.
Biochemistry Clinical practice CLS 432 Dr. Samah Kotb Lecturer of Biochemistry 2015 Introduction to Quality Control.
Quality control & Statistics. Definition: it is the science of gathering, analyzing, interpreting and representing data. Example: introduction a new test.
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Metrology for Chemical Analysis
B. Neidhart, W. Wegscheider (Eds.): Quality in Chemical Measurements © Springer-Verlag Berlin Heidelberg 2000 W. WegscheiderValidation: an Example 1 Learning.
BME 353 – BIOMEDICAL MEASUREMENTS AND INSTRUMENTATION MEASUREMENT PRINCIPLES.
Wenclawiak, B.: Fit for Purpose – A Customers View© Springer-Verlag Berlin Heidelberg 2003 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in.
Industrial Technology Institute Test Method Validation & Verification H.P.P.S.Somasiri Principal Research Scientist / SDD-QAD /QM Industrial Technology.
LECTURE 13 QUALITY ASSURANCE METHOD VALIDATION
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
SEMINAR ON PRESENTED BY BRAHMABHATT BANSARI K. M. PHARM PART DEPARTMENT OF PHARMACEUTICS AND PHARMACEUTICAL TECHNOLGY L. M. COLLEGE OF PHARMACY.
Chapter 5 Quality Assurance and
EQUIPMENT and METHOD VALIDATION
Establishing by the laboratory of the functional requirements for uncertainty of measurements of each examination procedure Ioannis Sitaras.
means to “TO CHECK OR PROVE THE VALIDITY OF” According to FDA – “ The goal of validation is to establish a documented evidence which provides a high degree.
Method Validation-where do I start?
Challenges in Method Validation – A Regulatory Laboratory Perspective
Quality is a Lousy Idea-
World Health Organization
Practical clinical chemistry
Quality is a Lousy Idea-
This teaching material has been made freely available by the KEMRI-Wellcome Trust (Kilifi, Kenya). You can freely download,
Analytical Method Validation
METHOD VALIDATION: AN ESSENTIAL COMPONENT OF THE MEASUREMENT PROCESS
Chapter 5 Quality Assurance and Calibration Methods
ANALYTICAL METHOD VALIDATION
World Health Organization
Presentation transcript:

Validation of Analytical Methods Evsevios Hadjicostas In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Introduction The importance of method validation Use of the information in this chapter Who should be aware of this chapter In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Contents The whats, whys, whens and hows of method validation The method performance parameters How to use validated methods In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

What is Method Validation? Method validation is the process of proving that an analytical method is acceptable for its intended purpose In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

What is Method Validation? Method performance parameters are determined using equipment that is: Within specification Working correctly Adequately calibrated Competent operators Method validation and method development In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Why is Method Validation Necessary? To increase the value of test results To justify customer’s trust To trace criminals To prove what we claim is true Examples To value goods for trade purposes To support health care To check the quality of drinking water In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

The Professional Duty of the Analytical Chemist To increase reliability of laboratory results To increase trust of laboratory customers To prove the truth In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

When should Methods be Validated New method development Revision of established methods When established methods are used in different laboratories/different analysts etc. QC indicates method changes Comparison of methods In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated Who Carries out Method Validation (I) Validation in a group of laboratories Collaborative studies Inter-laboratory comparisons In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated Who Carries out Method Validation (II) Validation in a single laboratory Comparisons with CRMs Comparisons with other methods that are validated In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated The Analytical Requirement (I) What are the analytes of interest? What are the expected concentration levels? Are there any interferences? How was the sampling done? In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated The Analytical Requirement (II) Which method is the most suitable? What degree of validation is required? How the method will be used? In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated Method Development The one extreme: few sketchy ideas The other extreme: minor changes In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated To What Degree Validation is Required Time and cost constrains Customers’ requirements Existing experience Compatibility with other similar methods In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated What Degree of Validation is Required Category of the method Action Interlaboratory tested Precision, trueness Interlaboratory tested but it applies with different material, different instrument Precision, trueness, limit of detection, selectivity Established but not tested Many From bibliography, with reference to performance characteristics From bibliography, without reference to performance characteristics In-house method Full validation In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

How should Methods be Validated What to Check (Performance Characteristics) Selectivity/Specificity Limit of Detection Limit of Quantitation Linearity Accuracy Trueness Sensitivity Ruggedness (or Robustness) Recovery In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Identity and Selectivity/Specificity Identity: Signal to be attributed to the analyte GLC (change column/polarity), GC/MS, Infra-red Selectivity: The ability of the method to determine accurately the analyte of interest in the presence of other components in a sample matrix under the stated conditions of the test. Specificity is a state of perfect selectivity In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Identity and Selectivity/Specificity Confirmation versus repeatability Confirmation: Measure by more than one technique Repeatability: Measure several times by one technique In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Identity and Selectivity/Specificity How to establish selectivity: Compare the response of the analyte in a test mixture with the response of a solution containing only the analyte. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Identity and Selectivity/Specificity The procedure to establish selectivity: Analyze samples and reference materials Assess the ability of the methods to confirm identity and measure the analyte Choose the more appropriate method. Analyze samples Examine the effect of interferences In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Limit of Detection (LoD) LoD:The lowest concentration of analyte in a sample that can be detected LoD = B+3S0 or 0+3S0 (for fortified samples; typically, three times the noise level) B=Blank S0=standard deviation of 10 measurements In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Expression of the LoD Analyze 10 independent sample blanks and get the mean sample blank value (B) or 10 independent sample blanks fortified at lowest acceptable concentration. Express LoD as the analyte concentration corresponding to B+3s or 0+3s (s being the sample standard deviation). In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Limit of Quantitation (LoQ) The Limit of Quantitation is the content which is equal or grader than the lowest concentration point on the calibration curve (i.e. what level can be measured) LoQ = B+10S0 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Limit of Detection (LoD) Limit of Quantitation (LoQ) Graphical method Six measurements in 3 concentration levels Std.dev. for each one level S=f(C) S0=intercept LoD = 3S0 Signal to Noise ratio S/N=3 (for the LoD) Signal to Noise ratio S/N=10 (for the LoQ) In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Linearity and Working Range The ability of the method to obtain test results which are proportional to the concentration of the analyte In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Linearity and Working Range Correlation coefficient, sufficient when r2 > 0.99 or 0.98 for very low concentrations Criterion No 1: R=kCn logR=nlogC+logk, LogR=f(logC), n=slope 1.1n0.9 (R:Response of the blank, k sens.,C conc, n coeff.) Criterion No 2: Response of the sample minus the response of the blank divided by the concentration as a function of the concentration value In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Regression Line, r2 Visual inspection is required In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Accuracy / Trueness Accuracy: the closeness of a result to a true value (=trueness+precision). Trueness:The closeness of agreement between the average value obtained from a large set of test results and an accepted reference value. Precision:how close results are to one another In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Good Accuracy Good Precision Good Precision Bad Accuracy Good Accuracy Bad Precision In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Using Certified Reference Materials Using RM or In-house materials Using Reference methods Single sample Many samples Via Interlaboratory study Using injected samples In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Using Certified Reference Materials Six analyses, then calculate the μ-2s < < μ+2s μ the certified value of CRM In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Using RM or In-house material the average of 10 measurements μ the “true” value of RM If texp<ttheor. For v=n-1, no statistically significant differance In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Using Reference methods Single sample our own method, Nx, x-bar reference method, Ny, y-bar Condition: texpttheor. and Fexp<Ftheor. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Many samples Analysed with our own method: x1,x2,..,xn Analysed with referee method: μ1,μ2,..,μn Condition: texp<ttheor. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Via Interlaboratory study In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Determination of Trueness Using injected samples Injection of a known quantity of a substance in a real sample determination of the recovery Cfrt: concentration determined in fortified sample Cunf: concentration determined in unfortified sample Cadd: concentration of fortification In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Interpretation of Bias Measured value (laboratory mean) True value Total bias Interlaboratory mean Laboratory bias Method bias In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Precision The closeness of agreement between independent test results obtained under stipulated conditions. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Precision Precision under repeatability conditions: Same method on identical test items, in the same laboratory,by the same operator, using the same equipment, within short time intervals Precision under reproducibility conditions Same method on identical test items, in different laboratories, with different operators, using different equipment. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Intermediate Precision Repeatability conditions and Reproducibility Conditions are extreme cases Intermediate cases are most frequent Same laboratory - different operators Same laboratory - different equipment etc ISO 5725 In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Evaluation of Precision 10 samples for each conc.under r,R, within lab R Standard Deviation R=3s (99%confidence, 15 days) Determination in pairs under r,R, within lab R Std. Dev. between two single determinations a-b, the difference between the values, d, the number of pairs In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Precision Repeatability limit Reproducibility limit In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Sensitivity The change in the response of a measuring instrument divided by the corresponding change in the stimulus In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Ruggedness and Robustness Intra-laboratory study to check changes due to environmental and/or operating conditions Usually it is part of method development Deliberate changes in Temperature Reagents ( e.g. different batches) Extraction time Composition in the sample etc In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

The Tools of Validation Blanks Reagent blanks Sample blanks Samples/test materials Fortified materials/solutions Spiked materials Incurred materials Independently characterized materials Measurement standards Reference materials Certified Reference materials Statistics Replication In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Using Validated Methods Make yourself familiar with the new method Make necessary preparations before you start working Analyze only an optimum number of samples Re-validate as appropriate In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Validation and Quality Control Internal QC QC samples and the use of control charts Warning and action limits QC samples to be within limits Realistic limits on the control chart Various types of blanks to correct the response Replicate analysis to check changes in precision Blind analysis to check precision Standards and chemical calibrants to check the stability of the response In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Validation and Quality Control External QC Proficiency testing Monitor of laboratory performance Highlight reproducibility Monitor of traceability Recognized by accreditation bodies PT results as means of checking QA In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Documentation of Validated Methods Documentation of the validation procedure Clear and unambiguous implementation Consistency during application Large uncertainty contribution if inadequately documented methods Information to be easily understood by everyone using the method In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

The Method Documentation Protocol Update & Review Summary Title Scope Warning & Safety precautions Definitions Principle Reagents & Materials Apparatus and equipment Sampling and samples Calibration Quality Control Procedure Calculation Reporting procedures including expression of results Normative references Appendix on method validation Appendix on measurement uncertainty In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Interpretation of Validation Data Validation data to give answers and solutions to customer’s problems Analyst’s access to the validation data The analytical chemist as a technical advisor Interpretation of the measurement uncertainty of results Legal and forensic contexts When reporting the results Either to correct for bias or to acknowledge bias “Not detected” statement to be accompanied by the detection limit Expression of uncertainties In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Summary The analytical method as a measurement tool Validation and revalidation Correct use of validation data Validation data as a measure of the method performance In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching

Where to Get More Information http://www.eurachem.ul.pt The Fitness for purpose of analytical methods, Eurachem Guide ISO 5725 –1986 (E), Precision of Test Methods - Determination of repeatability and reproducibility for a standard test method by interlaboratory tests. In: Wenclawiak, Koch, Hadjicostas (eds.) Quality Assurance in Analytical Chemistry – Training and Teaching