SmartMQn Motor Horner APG, LLC September 9, 2008.

Slides:



Advertisements
Similar presentations
Yokogawa Network Solutions Presents:
Advertisements

Variable Frequency Drives Bypass Options
سیستم آلارم دیجیتالی مجهز به ثبات خطا
Inputs: Digital and 4 configurable for Digital or 10 bit Analog Outputs:4 - 8 amp Relays or 700ma Transistors (1 PWM) 4 Line by 18 Character fully.
MIFII DIGITAL FEEDER PROTECTION A Cost Effective Protection Solution for Overcurrent Protection at Any Voltage Level GE Multilin
TPP-TCOMM-17/29/05#1TeleComm™ Control Panels TPP-TCOMM-17/29/05#1.
TG-EL-D5 Preferred Instruments Multi-Tank Gauge D5 Overview.
Multi-DNC Data Collection/Monitoring
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
1 Rev /02 Modular Construction Dual/Redundant CPU/Power Supply Support TCP/IP Communication Protocol 4096 Camera by 512 Monitor Switching English.
Digital video security systems 2 Multi-functional CCTV Management System The Most Complete Integrated Digital CCTV Management System.
FP5000 Refer to for the latest information on this constantly evolving productwww.eatonelectrical.com.
SYMAP-BC SYMAP-BC.
CSX Product Familiarisation Presentation to Audience - 15 September 2006.
Slide 1 / 35 P&T - GPS - Training PhB - 01_TECH_TeSys_U_controller_ en 06/2004 Presentation of the range Composition of the controller  Control base 
Applying Wireless in Legacy Systems
G GE Power Management MMII Intelligent MCC Controller.
1 PCA2 On-load Protection Condition Analyser. 2 PCA2 online testing concept Concept introduction: PCA2 is a new system test approach intended to save.
Chapter 8 Output Modules.
MIG II DIGITAL FEEDER PROTECTION
Chapter 7 SYSTEM PROTECTION
MP-3000 Motor Protection.
DEMONSTRATION FOR SIGMA DATA ACQUISITION MODULES Tempatron Ltd Data Measurements Division Darwin Close Reading RG2 0TB UK T : +44 (0) F :
G GE Power Management 369 Motor Management Relay.
Workflow Based Tools Simplifying All Job Functions.
G650 Generator Protection & Control System
Looking for a more powerful circuit monitor?
© 2006, ZTE Corporation. All rights reserved.   E300 Series Mini-type Integrated Universal Inverter.
GML-3 GPRS BASED METER AND LOGGER THREE PHASE METER WITH INBUILT DATA LOGGER © Embuilt Technologies Visit us at Or For.
ASAB New Additions Extended Bypass Models Ethernet Modules Remote Control Panel.
Operator Panel and Programmable Logic Controller.
NetVuze Precision Network Meter standalone, easy to use, networked with data logging.
Electrical Distribution Training
Need to enhance your network?
Electrical Distribution Training
The PAX Lite: PAX quality at a great low price.. PAX Lite Series Indication and Setpoint Control Simple field set-up Perfect the low-cost meter users.
Product range/ALPHA-E-0001-tri-20/04/03 ALPHA Micro Controllers A single multi-functional unit instead of multiple components ALPHA / ALPHA XL Products/ALPHA.
3-Phase Submersible Motor Control
Envision Application Examples Horner APG, LLC February 26, 2008.
Strategy for transition from products to solutions.
Motor. What Does it Do? Monitors three phase motors for a number of current, temperature, estimated power and timing parameters. Provides motor protection.
Cscape EnvisionRV Horner APG, LLC. EnvisionRV - What Does it Do? Allows viewing and interacting with remote OCS controllers. The PC displays screens that.
Franklin Electric - The Company You Trust Deep Down Provides The Ultimate Protection for Your Pump & Motor! Franklin SubMonitor.
OCS Remote Viewer Release 0.12 March 21, 2007 Confidential.
Envision Tutorial Horner APG, LLC July 18, Introduction The Cscape Remote Viewer allows remote interaction with the user interface on Horner OCS.
World Leaders in Combustion Management Solutions Remote Monitoring & Data Logging C.E.M.S I/O Modules DTI Autoflame Training,
Cscape EnvisionFX Horner APG, LLC March 7, EnvisionFX - What Does it Do? Graphical interface allows easy transfers of data to and from the PC and.
Water Horner APG, LLC June 4, What is SmartMQn Water? SmartMQn Water is a packaged monitoring solution that uses sophisticated and easy to use preconfigured.
Cscape 8.6 August 2008 Horner APG. New Workbench Features - New Model – XL6.
Energy Family Power Meter Energy Energy Plus & Energy Pro.
SmartMQn Motor Protective Functions Ken Jannotta Jr. Horner APG, LLC.
1 Industrial Systems BUS2000 Busbar Differential Protection System Differential overcurrent system with percentage restraint protection.
Alarm units AL 175 NT and Aeon Gold For small, medium and large power range.
G GE Power Management 269Plus Motor Management Relay.
AEON 4000 Including the SMPS 4000 rectifier and the AEON Gold Alarm & Monitoring Unit.
The Quality Control Company Quanti TM product series “Simplicity is the ultimate sophistication” - Leonardo da Vinci.
Altivar 32 So slim, So smart!
PROPRIETARY INFORMATION - © 2015 WOODWARD, INC. PAGE 1 HighPROTEC-2 MRI4-2 Feeder Relay Sales presentation 2015/08/10.
HighPROTEC-2 MRA4-2 Directional Feeder Relay Sales presentation
Intellisys System Manager Intellisys Energy Optimizer
HighPROTEC-2 MRMV4-2 Motor protection relay with voltage measurement Sales presentation 2015/08/10.
SGC-250 Synchronous Generator Controller
HighPROTEC-2 MRM4-2 Motor Protection Relay Sales presentation
HighPROTEC-2 MCDTV4-2 Transformer Protection with differential Sales presentation 2015/08/10.
GROUND-FAULT GROUND-CHECK MONITOR
FEEDER PROTECTION UNIT
MPU-16A / FPU-16 TEST UNIT TUTORIAL
HighPROTEC-2 MRDT4-2 Transformer Protection with differential Sales presentation 2015/08/10.
Integrated gateway-server
Presentation transcript:

SmartMQn Motor Horner APG, LLC September 9, 2008

SmartMqn Concept Horner Control Technology Applications pre-programmed by industry experts Configurable by end users with no PLC experience Packaged with everything to get started

What Does it Do? Monitors three phase motors for a number of current, temperature and timing parameters. Provides motor protection functions. Provides real-time and historical data of motor parameters. Optional local and remote start / stop control of the motor. Real-time and historical data displayed on a graphical user interface. Connectivity on serial, CAN and optional wireless, modem, Ethernet and cellular.

What are the Advantages? All in one solution – optionally includes the panel, 3 motor CTs and the controller Easy to use and install Powerful trending and data logging – up to 2 gigs of local data storage Advanced connectivity Built-in graphical user interface Optional remote monitoring capabilities

Monitored Parameters Phase and Ground current –A,B,C,Gnd Phase Amps –Average Amps –A,B,C,Gnd % of Full Load Current –Average % of Full Load Current Protection function accumulators –Thermal (TOC - calculated) –Thermal (PTC - measured) –Starts/Hr Motor run-time (Hours)

Protection Start Sequence Completion (ANSI 48) Starts-per-hour / Minutes-per-start protection (ANSI 66) Under-load current detection (ANSI 37) Overload current detection (or jam detection) Unbalanced current detection (ANSI 46) Stall detection (ANSI 50) Timed over-current (ANSI 51) Ground fault current detection (ANSI 50G) External Protection (ANSI 94) PTC Protection (ANSI 49) Circuit Breaker Monitor

Main Screen Operation The main screens shows critical information. Press one of the four soft keys to get more details. Alarms Motor Stats Motor State Trending

Monitoring / Logging Real-time trends of all currents. Historical trends before a trip showing the last 100 seconds, 16.5 minutes and last 16.5 hours. PTC Temperature trend. Data logging of phase currents, ground current, average current and PTC happens every 10 seconds to removable media. Data is logged in CSV format that can be read by Microsoft Excel or a variety of data analysis tools. Alarms and protection trips are also recorded with time and date stamps and recordings of currents and temperatures.

Inputs and Outputs Two auxiliary multifunction NO contacts Dedicated Alarm output NO contact (monitor mode) Dedicated NO/NC Latching Trip output (monitor mode) Configurable Single and Dual coil control outputs (controller mode) Three multifunction inputs Dedicated 52 contact input Trip reset (UI, terminal or network)

Connectivity Modbus Slave and CsCAN CAN Built-in Optional Ethernet Optional Radio Modem Optional Land Line Modem Optional Cellular Modem

PC Monitoring Compatible with Envision RV for remote viewing of the SmartMQn Motor panel locally or anywhere in the world (may require optional comm add-on). Compatible with Envision FX for transfer of data logging files from the SmartMQn Motor to a PC.

Data Example Alarms and Trips are stored in CSV format that can directly be opened in Excel.

Data Example Data is plotted with a couple of clicks in Excel.

Ordering Available with or without the panel package (includes panel, power supply, circuit breaker and wiring block). Includes three motor CTs supporting 50, 450 and 1000 Amp loads. Optional Communication Add-ons Part NumberDescription HS-MNXM-005Motor Monitor industry solution with three 50A CTs. Includes HE-XE102, 5A Circuit Breaker, 24V 1.5A Power Supply HS-MNXM-045Motor Monitor industry solution with three 450A CTs. Includes HE-XE102, 5A Circuit Breaker, 24V 1.5A Power Supply HS-MNXM-100Motor Monitor industry solution with three 1000A CTs. Includes HE-XE102, 5A Circuit Breaker, 24V 1.5A Power Supply HS-MPXM-005Motor Monitor industry solution with three 50A CTs. No Panel HS-MPXM-045Motor Monitor industry solution with three 450A CTs. No Panel HS-MPXM-100Motor Monitor industry solution with three 1000A CTs. No Panel Communication Option HE-XEC 10/100 Ethernet option kit - field installable. Kit includes all parts necessary for internal installation within the XLe case, including a deeper plastic back cover adapted for Ethernet operation.

Inputs and Outputs - Details Configurable Inputs for: –External protection functions (2) –Start / Stop –52A – circuitbreaker sense –Reset - (trip, alarm, etc) –Remote - switch control to remote point Configurable Outputs for: –Auxiliary outputs (2) controlled by network –Run / Stop indications –R+A - Run with flash if alarm present –S+T - Stop with flash if trip present –Block Start - typically used with dual coil contactor Outputs Assigned based on Configuration: –Alarm / Trip –Pulse Trip - Stop relay is pulsed –Latch - Circuit is made on RUN and broken on STOP or TRIP. –Pulse On / Off Pulsed on run / stop or trip commands