Feb. 7, 2007First GLAST symposium1 Measuring the PSF and the energy resolution with the GLAST-LAT Calibration Unit Ph. Bruel on behalf of the beam test.

Slides:



Advertisements
Similar presentations
Update on Beamtest 06 CU PSF study C. Cecchi S. Germani M. Pepe Università di Perugia and INFN Gamma-ray Large Area Space Telescope Beam Test Worksop II.
Advertisements

Antonis Leisos KM3NeT Collaboration Meeting the calibration principle using atmospheric showers the calibration principle using atmospheric showers Monte.
New results from the CHORUS Neutrino Oscillation Experiment Pasquale Migliozzi CERN XXIX International Conference on High Energy Physics UBC, Vancouver,
Status of DHCAL Slice Test Data Analysis Lei Xia ANL-HEP All results preliminary.
Reconstruction neutral decay modes (E391) Doroshenko M.(KEK) E391 collaboration Outlines: Data summary Analysis strategy Reconstruction K3p,K2p,Kgg decays.
27 th June 2008Johannes Albrecht, BEACH 2008 Johannes Albrecht Physikalisches Institut Universität Heidelberg on behalf of the LHCb Collaboration The LHCb.
GLAST LAT Project Calibration & Analysis Meeting - August 29, 2005 Benoît Lott Gamma-ray Large Area Space Telescope Response of the GLAST LAT Calorimeter.
GLAST LAT ProjectIA Workshop 6 – Feb28,2006 Preliminary Studies on the dependence of Arrival Time distributions in the LAT using CAL Low Energy Trigger.
GLAST LAT ProjectCU Beam Test 11/8/2005 L. Latronico1 Glast LAT Calibration Unit Beam Test at CERN Overview of Tasks 11/8/2005.
A.Chekhtman1 GLAST LAT ProjectCalibration and Analysis group meeting, April, 3, 2006 CAL on-orbit calibration with protons. Alexandre Chekhtman NRL/GMU.
The performance of LHCf calorimeter was tested at CERN SPS in For electron of GeV, the energy resolution is < 5% and the position resolution.
GLAST LAT Project Instrument Analysis Workshop 5 – 05/08/29 F. Piron & E. Nuss (IN2P3/LPTA – Montpellier) 1 Comprehensive review of CAL calibrations Gamma-ray.
1 May 27, 2005 Comparison tower A data and Montecarlo OVERVIEW Comparison of MC (EM- v 4r060302p18 ) and tower A data using the “baseline” run (Run )
In order to acquire the full physics potential of the LHC, the ATLAS electromagnetic calorimeter must be able to efficiently identify photons and electrons.
GLAST LAT Project Test Beam Meeting, June 6, 2006 S. Funk 1/6 PS Positron Simulations Stefan Funk June 6, 2006.
Tracker Reconstruction SoftwarePerformance Review, Oct 16, 2002 Summary of Core “Performance Review” for TkrRecon How do we know the Tracking is working?
Cosmic Rays Data Analysis with CMS-ECAL Mattia Fumagalli (Università di Milano Bicocca) CIAO!
GLAST LAT ProjectBeam Test Meeting 1/21/2006 L. Latronico1 Beam test activity in Italy Integration & test activities –1x1 tower completed and under test.
Michele Faucci Giannelli TILC09, Tsukuba, 18 April 2009 SiW Electromagnetic Calorimeter Testbeam results.
Preliminary comparison of ATLAS Combined test-beam data with G4: pions in calorimetric system Andrea Dotti, Per Johansson Physics Validation of LHC Simulation.
PERFORMANCE OF THE MACRO LIMITED STREAMER TUBES IN DRIFT MODE FOR MEASUREMENTS OF MUON ENERGY - Use of the MACRO limited streamer tubes in drift mode -Use.
Preliminary Study of CC-Inclusive Events in the P0D using Global Reconstruction Rajarshi Das (w/ Walter Toki) Nu-Mu Prelim. Meeting Dec 2010 CSU.
Large Magnetic Calorimeters Anselmo Cervera Villanueva University of Geneva (Switzerland) in a Nufact Nufact04 (Osaka, 1/8/2004)
Marco Delmastro 23/02/2006 Status of LAr EM performance andmeasurements fro CTB1 Status of LAr EM performance and measurements for CTB Overview Data -
Event Reconstruction in SiD02 with a Dual Readout Calorimeter Detector Geometry EM Calibration Cerenkov/Scintillator Correction Jet Reconstruction Performance.
CALICE Digital Hadron Calorimeter: Calibration and Response to Pions and Positrons International Workshop on Future Linear Colliders LCWS 2013 November.
A.Chekhtman1 GLAST LAT ProjectInstrument Analysis meeting, February, 27, 2006 CAL features and idiosyncrasies. Alexandre Chekhtman NRL/GMU Gamma-ray Large.
Aa GLAST Particle Astrophysics Collaboration Instrument Managed and Integrated at SLAC/Stanford University The Gamma-ray Large Area Space Telescope (GLAST)
Results from particle beam tests of the ATLAS liquid argon endcap calorimeters Beam test setup Signal reconstruction Response to electrons  Electromagnetic.
Gamma-ray Large Area Space Telescope 15th INTERNATIONAL WORKSHOP ON VERTEX DETECTORS September , 2006 Perugia, Italy GLAST Silicon Tracker beam.
CBM ECAL simulation status Prokudin Mikhail ITEP.
Calorimeter in front of MUCh Mikhail Prokudin. Overview ► Geometry and acceptance ► Reconstruction procedure  Cluster finder algorithms  Preliminary.
Test beam preliminary results D. Di Filippo, P. Massarotti, T. Spadaro.
1 The CALICE experiment at MTBF (FNAL) summary of a fruitful test beam experiment Erika Garutti (DESY) On behalf of CALICE.
Min-DHCAL: Measurements with Pions Benjamin Freund and José Repond Argonne National Laboratory CALICE Collaboration Meeting Max-Planck-Institute, Munich.
CALOR April Algorithms for the DØ Calorimeter Sophie Trincaz-Duvoid LPNHE – PARIS VI for the DØ collaboration  Calorimeter short description.
Status of the hadronic cross section (small angle) Federico Nguyen February 22 nd 2005  the 2002 data sample and available MC sets  trigger efficiency.
GLAST LAT Project CU Beam Test Workshop 3/20/2006 C. Sgro’, L. Baldini, J. Bregeon1 Glast LAT Calibration Unit Beam Test Status Report on Online Monitor.
5-9 June 2006Erika Garutti - CALOR CALICE scintillator HCAL commissioning experience and test beam program Erika Garutti On behalf of the CALICE.
(s)T3B Update – Calibration and Temperature Corrections AHCAL meeting– December 13 th 2011 – Hamburg Christian Soldner Max-Planck-Institute for Physics.
Nantes — 2008, July Analysis of results from EmCal beam test at CERN PS (and SPS) energies P. La Rocca & F. Riggi University & INFN Catania University.
D 0 reconstruction: 15 AGeV – 25 AGeV – 35 AGeV M.Deveaux, C.Dritsa, F.Rami IPHC Strasbourg / GSI Darmstadt Outline Motivation Simulation Tools Results.
LHCf Detectors Sampling Calorimeter W 44 r.l, 1.6λ I Scintilator x 16 Layers Position Detector Scifi x 4 (Arm#1) Scilicon Tracker x 4(Arm#2) Detector size.
06/2006I.Larin PrimEx Collaboration meeting  0 analysis.
David Silvermyr Lund University for the PHENIX Collaboration Early global event results using the PHENIX Pad Chambers at RHIC.
Test Beam Results on the ATLAS Electromagnetic Calorimeters Lucia Di Ciaccio – LAPP Annecy (on behalf of the ATLAS LAr Group) OUTLINE Description of the.
Régis Lefèvre (LPC Clermont-Ferrand - France)ATLAS Physics Workshop - Lund - September 2001 In situ jet energy calibration General considerations The different.
1 Study of Data from the GLAST Balloon Prototype Based on a Geant4 Simulator Tsunefumi Mizuno February 22, Geant4 Work Shop The GLAST Satellite.
Feb. 3, 2007IFC meeting1 Beam test report Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope.
Paolo Massarotti Kaon meeting March 2007  ±  X    X  Time measurement use neutral vertex only in order to obtain a completely independent.
M. Martemianov, ITEP, October 2003 Analysis of ratio BR(K     0 )/BR(K    ) M. Martemianov V. Kulikov Motivation Selection and cuts Trigger efficiency.
Higgs Recoil Mass Measurement and ZH Cross Section Tim Barklow, Awatif Belymam SLAC Feb 24, 2009.
David Lange Lawrence Livermore National Laboratory
Report of GLAST Balloon Flight October Annual meeting of Astronomical Society of Japan T. Mizuno and other GLAST Balloon Team
HARPO Analysis.
GLAST Large Area Telescope:
Jin Huang Los Alamos National Lab
5% The CMS all silicon tracker simulation
STAR Geometry and Detectors
Gamma-ray Large Area Space Telescope
Charged Particle Multiplicity in DIS
Imaging crystals with TKR
Mini Tower Preliminary Results
The LHCb Level 1 trigger LHC Symposium, October 27, 2001
Michele Faucci Giannelli
J/Y Simulations for Trigger
CR Photon Working Group
Studies of the Time over Threshold
Overview of Beam Test Benoit, Ronaldo and Eduardo Nov 8 , 2005 thanks to Steve and Bill for helping to consolidate all the information.
Presentation transcript:

Feb. 7, 2007First GLAST symposium1 Measuring the PSF and the energy resolution with the GLAST-LAT Calibration Unit Ph. Bruel on behalf of the beam test working group Gamma-ray Large Area Space Telescope

Feb. 7, 2007First GLAST symposium2 Measuring the PSF and the energy resolution Data/Simulation agreement and the LAT analysis Beam tests at CERN (PS and SPS) –Tracker and PSF –Calorimeter and energy resolution Conclusions

Feb. 7, 2007First GLAST symposium3 Data/simulation agreement and analysis Event processing steps : –Trigger and On Board Filter –Reconstruction algorithms –Classification trees ( -> IRFs and Background rejection ) Example 1 : PSF –Tracks, vertices are reconstructed –Using not only tkr variables, the classification tree gives : The best estimate of the incoming direction of the gamma A quality variable used to select the best measured gammas Example 2 : Energy resolution –3 energy reconstruction algorithms -> 3 estimates –Using not only cal variables, the classification tree gives : The best estimate of the energy of the gamma A quality variable used to select the best measured gammas The calibration unit is different from the LAT –We can not apply directly and simply the classification tree analysis –But we can compare between data and MC the PSF of each direction estimate The energy resolution of each energy estimate

Feb. 7, 2007First GLAST symposium4 Dealing with a huge phase space… 1700 runs, 94M events, 330 configurations (particle, energy, angle, impact position) For PSF and energy resolution analysis : gammas (->2.5 GeV), electrons (5->280 GeV)

Feb. 7, 2007First GLAST symposium5 Mass simulation Simulation of the beam upstream the CU (Geant4) –Trigger/veto scintillators & cerenkov –Electron tagger at PS LAT simulation (GLEAM-Geant4) Automatic generation of the run configuration –Allowing the best comparison Efficient processing through the pipeline at SLAC Geant4 optimization –Simulation parameters –Physics lists

Feb. 7, 2007First GLAST symposium6 Tracker (work in progress…) 10-20% more hits in data than in MC Effect almost independent of particle, E Clusters are well reproduced by MC More secondary particles / preshower ? –Lower range cuts in Geant4 : no effect –Testing low energy processes –The calorimeter should say if there is extra material upstream the CU Hit multiplicity for gammas (0.5 to 2.5 GeV) Hit multiplicity for 100 GeV electrons Cluster-axis distance for 20 GeV electrons

Feb. 7, 2007First GLAST symposium7 Tracker (work in progress…) Preliminary PSF results for events with 1 vertex and 2 tracks shows a good agreement between data and the simulation This not yet the PSF from the IRFs (i.e after signal selection and background rejection) <- 68% PSF 95% ->

Feb. 7, 2007First GLAST symposium8 Calorimeter (work in progress…) Importance of quality/fiducial cuts Raw energy : 10% more energy in data for electrons at SPS

Feb. 7, 2007First GLAST symposium9 Calorimeter (work in progress…) The beam tests allow us to fully understand the electronics of the calorimeter –High rates –Cross-talk –Non linearity The 10% energy excess at high energy is mainly due to calibration issues –2diodes x 2gains : 4 ranges from 1 MeV -> 70 GeV –Ground calibration : muon peak at 11 MeV –CERN data allow a complete check of our procedure to extrapolate the energy scale from 11 MeV up to 70 GeV

Feb. 7, 2007First GLAST symposium10 Calorimeter (work in progress…) Very good agreement at PS energies Thanks to the electron tagger, we can measure the energy resolution from 50 MeV up to 2.5 GeV After naive calibration correction, very good agreement at SPS energies 280 GeV electrons at 30 deg

Feb. 7, 2007First GLAST symposium11 Conclusions A huge amount of good quality data to ensure that our simulation well reproduces the data through the LAT very large phase space Data reprocessing and mass simulation are fast and easy Ongoing tests to understand the current low-level disagreements The preliminary results show that PSF and energy resolution are well reproduced by the simulation