SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry;

Slides:



Advertisements
Similar presentations
of Single-Type-Column 3D silicon detectors
Advertisements

New developments of Silicon Photomultipliers (for PET systems)
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Fiberless Coupled Tiles for a High Granularity Scintillator-SiPM Calorimeter Rick Salcido Northern Illinois University November 14, 2009 Prairie Section.
Charge collection studies on heavily diodes from RD50 multiplication run G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Introduction on SiPM devices
Photon detection Visible or near-visible wavelengths
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
H.-G. Moser Max-Planck-Institut for Physics, Munich CALOR 06 Chicago June 5-9, 2006 Silicon Photomultiplier, a new device for low light level photon detection.
Charge collection studies on heavily diodes from RD50 multiplication run (update) G. Kramberger, V. Cindro, I. Mandić, M. Mikuž Ϯ, M. Milovanović, M. Zavrtanik.
Options for Dual-Readout Calorimetry in the 4 th Concept * (Light-Emitting) Active Media * (Photon-Sensing) Detectors * (Time-Domain) Signal Processing.
11 th RD50 Workshop, CERN Nov Results with thin and standard p-type detectors after heavy neutron irradiation G. Casse.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Evaluation of Silicon Photomultiplier Arrays for the GlueX Barrel Calorimeter Carl Zorn Radiation Detector & Medical Imaging Group Jefferson Laboratory,
MPPC Radiation Hardness (gamma-ray & neutron) Satoru Uozumi, Kobe University for Toshinori Ikuno, Hideki Yamazaki, and all the ScECAL group Knowing radiation.
C. Piemonte 1 Development of SiPMs a FBK-irst C.Piemonte FBK – Fondazione Bruno Kessler, Trento, Italy
Detector development and physics studies in high energy physics experiments Shashikant Dugad Department of High Energy Physics Review, 3-9 Jan 2008.
Salvatore Tudisco The new generation of SPAD Single Photon Avalanche Diodes arrays I Workshop on Photon Detection - Perugia 2007 LNS LNS.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
Silicon Photomultipliers and other advanced silicon sensors The INFN MEMS project R. Battiston INFN Perugia March 12th 2007.
Photodetection EDIT Internal photoelectric effect in Si Band gap (T=300K) = 1.12 eV (~1100 nm) More than 1 photoelectron can be created by light in silicon.
Fully depleted MAPS: Pegasus and MIMOSA 33 Maciej Kachel, Wojciech Duliński PICSEL group, IPHC Strasbourg 1 For low energy X-ray applications.
Summary of CMS 3D pixel sensors R&D Enver Alagoz 1 On behalf of CMS 3D collaboration 1 Physics Department, Purdue University, West Lafayette, IN
June 1-5, Santa Fe N. M. Vertex Ultra-fast Silicon Detectors June 3, 2015 Abe Seiden UC Santa Cruz.
An e.m. calorimeter on the Moon surface R.Battiston, M.T.Brunetti, F. Cervelli, C.Fidani MoonCal.
SiPM technology at FBK C. Piemonte
CERN, November 2005 Claudio Piemonte RD50 workshop Claudio Piemonte a, Maurizio Boscardin a, Alberto Pozza a, Sabina Ronchin a, Nicola Zorzi a, Gian-Franco.
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
1/14 Characterization of P-type Silicon Detectors Irradiated with Neutrons M.Miñano 1, J.P.Balbuena 2, C. García 1, S.González 1, C.Lacasta 1, V.Lacuesta.
10 th Pisa Meeting on Advanced Detectors, Isola d’Elba, May 2006 Development of the first prototypes of Silicon Photomultiplier at ITC-irst N. Dinu, R.
28 June 2007G. Pauletta: ALCPG Tests of IRST SiPMs G. Pauletta Univ. & I.N.F.N. Udine Outline 1.IRST SiPMs : baseline characteristics 2.first application.
9 th “Trento” Workshop on Advanced Silicon Radiation Detectors Genova, February 26-28, 2014 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica.
TCT measurements with SCP slim edge strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko.
1 CPTA Center for Prospective Technologies & Aparatus ©2009 – Photonique SA (DMC) APD-Pixel Photo-Diodes for Frontier Detector Systems - GSI Darmstadt.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
December Status of MRS photodiodes ND280 Convener’s Meeting, 9 June 2006 Yury Kudenko INR, Moscow.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
ICT 1 SINTEF Edge-On Sensor with Active Edge Fabricated by 3D-Technology T. E. Hansen 1), N. Ahmed 1), A. Ferber 2) 1) SINTEF MiNaLab 2) SINTEF Optical.
Charge Multiplication Properties in Highly Irradiated Thin Epitaxial Silicon Diodes Jörn Lange, Julian Becker, Eckhart Fretwurst, Robert Klanner, Gunnar.
Giulio Pellegrini 27th RD50 Workshop (CERN) 2-4 December 2015 Centro Nacional de MicroelectrónicaInstituto de Microelectrónica de Barcelona 1 Status of.
FBK 3D CMS pixel sensors preliminary lab measurements E. Alagoz 1, A. Krzywda 1, D. Bortoletto 1, I. Shipsey 1, G. Bolla 1, and G. F. Dalla Betta 2, M.
Characterization of 3D and planar Si diodes with different neutron converter materials R. Mendicino, M. Dalla Palma, M. Boscardin, S. Ronchin, G.-F. Dalla.
Claudio Piemonte Firenze, oct RESMDD 04 Simulation, design, and manufacturing tests of single-type column 3D silicon detectors Claudio Piemonte.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Silicon Photomultiplier Development at GRAPES-3 K.C.Ravindran T.I.F.R, OOTY WAPP 2010 Worshop On behalf of GRAPES-3 Collaboration.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
TCT measurements with strip detectors Igor Mandić 1, Vladimir Cindro 1, Andrej Gorišek 1, Gregor Kramberger 1, Marko Milovanović 1, Marko Mikuž 1,2, Marko.
Study of the Radiation Damage of Hamamatsu Silicon Photo Multipliers Wander Baldini Istituto Nazionale di Fisica Nucleare and Universita’ degli Studi di.
Investigation of the effects of thickness, pitch and manufacturer on charge multiplication properties of highly irradiated n-in-p FZ silicon strips A.
TCT measurements of HV-CMOS test structures irradiated with neutrons I. Mandić 1, G. Kramberger 1, V. Cindro 1, A. Gorišek 1, B. Hiti 1, M. Mikuž 1,2,
IFR Detector R&D status
Characterization and modelling of signal dynamics in 3D-DDTC detectors
Scintillation Detectors in High Energy Physics
First production of Ultra-Fast Silicon Detectors at FBK
Frontier Detectors for Frontier Physics
Graeme Stewarta, R. Batesa, G. Pellegrinib, G. Krambergerc, M
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
ILC Detector Activities in Korea
HCAL – SiPM upgrade requirements
Overview on calorimetry R&D for FACTOR (Messina/Trieste/Udine approach) (V. Bonvicini et al.) A. Penzo (June 4, 2008)
Igor Mandić1, Vladimir Cindro1, Gregor Kramberger1 and Marko Mikuž1,2
Presentation transcript:

SIPMs: Italy Team Report SiPMs development at FBK-irst started in 2005 as collaboration with INFN ( * ) for: - tracking with sci-fi; - PET; - TOF; - calorimetry; - muon counters. ( * ) Pisa, Bari, Bologna, Messina, Perugia, Roma, Trento,Trieste, Udine INFN Aldo Penzo, INFN-Trieste HCAL Working group, CMS Upgrade Workshop FNAL, 19 Nov 2008 Trieste Ljublijana Legnaro TrentoUdine

Summary of multiple contributions Valter Bonvicini - The INFN R&D FACTOR Claudio Piemonte - Development of SiPMs at FBK-irst Arjan Heering - Requirements of SiPMs for CMS HCAL upgrades Adam Para - Photodectors for dual readout calorimetry: characterization and testing of SiPMT's Aldo Penzo - Calorimetry R&D in FACTOR Dalla Torre - Single photon detectors for Cherenkov Imaging Valter Bonvicini - Preliminary results on SiPM irradiation tests Giovanni Pauletta - SiPM characterization and applications; past and future test activities at FNAL

FACTOR Project Within FBK/irst - INFN agreement, a (3-year) project (FACTOR) aims at establishing SiPMs as choice devices for (dual) readout of (compensating) hadron calorimeters. FBK-IRST has long-standing collaboration with INFN in the fields of: –Radiation-hard Si detectors (for SLHC) –use of oxigen-rich substrates: DOFZ substrates Cz/MCz substrates (M agnetic Czochralski) Epitaxial substrates –use of p-type substrates –Integration of Si detectors and (front-end) circuits on the same substrate –3D detectors [Walter Bonvicini et al.: Messina, Roma, Trieste, Udine + FBK/irst]

ITC-IRST (Trento) ITC (Now Fondazione Bruno Kessler ) – IRST is a public research and technology Institute, working since 1994 on the development and on the production od semiconductor devices for research and applications. It has a fully equipped Microfabrication Laboratory in which silicon devices are built. - Ion Implanter - Furnaces - Litho (Mask Aligner ) - Dry&Wet Etching - Sputtering &Evaporator - On line inspection - Dicing

Activity of SRD group Development and production of Si radiation detectors. Expertise covers the main aspects of the development: TCAD simulation CAD design Fabrication Device testing

Previous/current products Double-sided strip detectors: –Area:7.5x4.2cm2 –Orthogonal or inclined strips on 2 sides –DC- or AC-coupled – “in spec” devices fabricated for AMS and ALICE ( ) Pixel detectors: –MEDIPIX (thick 1.5mm), 170x170/55x55  m 2 –ALICE (200  m) 400x50  m 2

3D Si Detectors See S. Parker et al., NIM A395 (1997) Short distance electrodes n e p:  low depletion voltage  short charge collection distance column type n column type p Wafer surface Substrate type n extremely fast and radiation resistant Ionising trackelectrons holes (carriers generated along the track are collected almost simoultaneously) Electrodes are columns penetrating into the bulk

3D Si Detector Project FBK-irst and INFN-Trieste (L. Bosisio et al.) Collaboration for tests: – Ljubljana – UC Santa Cruz – INFN-Genova (ATLAS Pixel) – CERN (ALICE Pixel) Applications of this technology in other devices: – ‘throughout holes” transfer signals to back face (ex.SiPM) – planar detectors with “active edge’ (ex. imaging X-rays) n+ diffusion contact metal oxide hole SEM pictures of 3D devices Col. depth 180  m Col. width 10  m

SiPM IRST technology Substrate: p-type epitaxial 2) Very thin n+ layer 3) Polysilicon quenching resistance 4) Anti-reflective coating optimized for ~420nm n+n+ p Shallow-Junction SiPM p+ subst.  epi n+ Drift region High field region p guard region [C. Piemonte: “A new Silicon Photomultiplier structure for blue light detection” NIMA 568 (2006) ]

Configuration on Si wafer First production run (2005) square SiPMs with area: - 1x1mm 2,2x2mm 2 - 3x3mm 2, 4x4mm 2 - circular SiPMs - linear arrays of SiPMs: - 1x8, 1x16, 1x32 - 4x4 matrix of SiPMs Main block Wafer Second production run

Characteristics of FBK-irst SiPMs Fill factor: 40x40  m 2 => ~ 40% 50x50  m 2 => ~ 50% 100x100  m 2 => ~ 76% 1x1mm 2 2x2mm 2 3x3mm 2 (3600 cells) 4x4mm 2 (6400 cells) Geometries: Circular: diameter 1.2mm diameter 2.8mm

Tests performed at FBK I-V measurement – fast test to verify functionality and uniformity of the properties Functional characterization in dark – for a complete characterization of the output signal and noise properties (signal shape, gain, dark count, optical cross-talk, after-pulse) Photo-detection efficiency C. Piemonte et al. “Characterization of the first prototypes of SiPM fabricated at ITC-irst” IEEE TNS, February 2007

Leakage current: mainly due to surface generation at the micro-diode periphery Static characteristic (I-V) Breakdown voltage Breakdown current: determined by dark events Very useful fast test. Gives info about: - Device functionality - Breakdown voltage - (Dark rate)x(Gain) uniformity - Quenching resistance (from forward I-V) Reverse I-V Performed on several thousands of devices at wafer level

Dark signals are exactly equal to photo-generated signals functional measurements in dark give a complete picture of the SiPM functioning Signal properties – NO amplifier Thanks to the large gain it is possible to connect the SiPM directly to the scope V BIAS SiPM 50  Digital Scope SiPM: 1x1mm 2 Cell: 50x50  m 2

15 Pulse gen. Laser Pulse area = charge histogram collection SiPM ~ns 1p.e pedestal. Excellent cell uniformity Linear gain Signal properties – NO amplifier

s = single d = double pulses a = after-pulse V BIAS SiPM 50  Digital Scope Pulses at the scope. Av 100x Signal properties – with amplifier A voltage amplifier allows an easier characterization, but attention must be paid when determining the gain

Microcell functionality measurements measurements with RWTH, Aachen and Josef Stefan, Ljublijana

Pencil LED scan Measurement of the microcells with 5  m

Uniformity map

4x4mm 2 Signal shape 1mm 2 SiPM 16 x Dark Count of 1mm 2 SiPM -15C -25C -15C -25C Gain Dark count 4x4mm 2 SiPM - 50x50  m 2 cell

Same conclusions as for the previous device: Excellent cell response uniformity over the entire device (6400 cells) Width of peaks dominated by electronic noise 28.6V 29.2V 29.6V T=-25C Vbd=27.6V Charge spectra when illuminating the device with short light pulses

Each of the above curves represents the dark count rate as a function of the counting discriminator threshold. Different curves correspond to different bias voltages. Dark counts were also measured as a function of temperature. Dark counts vs discrim. threshold

Photo-detection efficiency

 V=2V 2.5V 3.5V 3V 4V QE vs Wavelength long : low PDE because low QE short : low PDE because avalanche triggered by holes Measured on a diode Reduced by small epi thickness Reduced by ARC Area efficiency ~ 20% PDE=QE*Pt*Ae QE=quantum eff. P t =avalanche prob. A e =area eff. PDE

Comparison of PDE From Arjan in Trieste, 3 June 2008 HB,HE,HO HF

Activities at Trieste-Udine The FACTOR collaboration is interested in the development of the device and in its optimization for application to: Present application interests: – Calorimetry with fiber-based optical readout – Large – area scintillator – based muon counters –Scintillating fiber – based tracking – future space experiments for detection of UHECR –FEL studies and instrumentation – future large – area, ground – based x-ray telescopes Action Plan: –comparative studies for detailed understanding of device characteristics –Application tests –Optimization of properties as a function of application

First year FACTOR 2007: mainly dedicated to device characterization and test: Comparison of SiPM characteristics produced by different manufacturers; Measurements of SiPM characteristics as a function of T; Irradiation of the devices and study of radiation damage effects; Tests with SiPMs coupled to wls fibers for scintillator read-out. Energy and time resolution measurements; Study of optimal packaging, electronics placement, etc. At the moment, we are performing tests on SiPMs from 3 different sources: Forimtech (MRS): – 1 mm2 in TO18 - P  560 nm µcells  43x43 µm2 Photonique (MRS): – “GR sensitive” - 1 mm2 in TO µcells ~ 43x43 µm2 – “Blue sensitive” - 1 mm2 in TO µcells ~ 43x43 µm2 – “Blue sensitive” mm2 on PCB µcells ~ 50x50 µm2 – “Blue enhanced” – 9 mm2 in TO5 – 8100 µcells ~ 33x33 µm2 IRST (polysilicon), 1 mm2 - P  420 nm (devices from 2nd and 3rd batch) – 625 µcells, 40x40 µm2

Fast Amplifier Amplifier used for fast characterization of SiPMs: Agilent ABA GHz RFIC Amplifier (economic, compact, internally 50-Ω matched, gain ~ 20 dB)

Amplifier Characterization Temperature dependence: Measurements performed with the DUT in a climatic chamber (with humidity control) The amplifier was outside the chamber, connected via a special 18 GHz ft 50  cable. Timing characteristics can be studied

Test Setup at INFN Lab

Present Tasks SiPM Development –Comparative device characterization (ISRT, Hamamatsu, Formitech) –Development (in collaboration with IRST) –Optimization of packaging & (fast!) preamplification Irradiation studies (so far on 24 SiPM's) –FBK-irst, Hamamatsu Photonique, Formitech INFN Legnaro Labs (50 – 500 krad) IJS reactor, Ljubljana (~4.8 x n/cm 2 ) Application Studies –Large area muon counters (FNAL) –Calorimetry with optical readout (FNAL/CERN/Frascati) –Scintillator-based fine-grained hodoscopes (CERN) Preliminary study of Scint. Strips viewed by IRST SiPM at the FNAL test beam (prototype of muon detector/tail catcher for ILC)

Test at Frascati Electron beam with a Cherenkov calorimeter counting multiplicity

Test beam at CERN Test beam at CERN (May/June 2008) with the MICE experiment: 8 extruded scintillator bars (1.5x1.9x19 cm3) with wls fibers, read out by SiPMs (IRST and Hamamatsu), all other bars of the MICE calorimeter read out by MAPMT. An ad hoc mechanical receptacle was realized to couple and align the fibers with the SiPMs and test them in a 2 GeV positron beam Frontend electronics: VA64TAP3.1 +LS64 by Gamma Medica-IDEAS; trigger signals sampled by an Altera with a 320 MHz clock

Mice detector A small fraction of the prototype fibers are readout with SiPM. The SiPM receptacle is visible to the right

The SiPM response Correlation MAPMT vs SiPM amplitude Pulse-height plot of the SiPM obtained selecting good events on the MAPM side

Radiation studies Systematic campaign this year: study resistance to radiation effects of SiPMs produced by different manufacturers –Objective: study both surface and bulk damage in the devices –Types of radiation used: X-rays (up to 50 keV) and neutrons –Measurement strategy: I-V characterization, dark count and gain before and after irradiations, annealing studies –24 devices from FBK-irst, Photonique (CPTA) and Hamamatsu irradiated so far; further irradiations are foreseen in the next weeks X-rays: INFN National Laboratories of Legnaro (LNL), X-ray tube (W target), Vmax = 50 kV, dose rate measured with calibrated Si p-i-n diodes Neutrons: Nuclear Reactor of the Institute Josef Stefan of Ljubljana (Slo), max power ~ 250 kW, very high fluence achievable INFN Legnaro Labs (50, 100 and 150 krad); INFN Legnaro Labs (300 and 500 krad); IJS reactor, Ljubljana (fluence ~ 4.8 x n/cm -2 );

Irradiation studies (so far on 24 SiPM's) INFN Legnaro Labs (50 – 500 krad) IJS reactor, Ljubljana (~4.8 x n/cm 2 ) –(spectrum ?) –Very preliminarly: –With 300 krad X-rays, HPK DC increase by 20 – 25 –FBK by –With 500 krad, HPK by 36-40, FBK by –With 4.8 x n/cm 2, HPK DC increase by 45-60, FBK by (See next page)

Other measurements and estimates See: T. Matsumura (June 29, 2007) International Workshop on new photon-detectors (PD07) (Kobe University) Neutron ≈ Proton Proton ≈ 100 x X-ray

Triga 3 reactor JSL

Magnetic field resistance “Investigation of a Solid-state Photodetector”, NIM A 545: (2005). “Effects of a strong magnetic field on LED, extruded scintillator and MRS photodiode”, NIM A553: (2005) (Vishnu V. Zutshi)

SiPM for HF? PMT fake signals in HF: show-stopper? SiPM useful but: Radiation hard? Small dimensions? Dinamic range? Consider matrix of 4x4 mm 2 FBK SiPM –To cover 2.4 cm diameter PMT window ~130 GeV up to few TeV!

SiPM matrix… …if 1 SiPM costs ≤10$ … … not out of question?