Pad Characterization Update Caprice Gray Nov. 9, 2006 Cabot Microelectronics Aurora, IL.

Slides:



Advertisements
Similar presentations
Adjusting a Microscope 1Center components on optic axis 2Focus objective 3Focus condenser 4Adjust illumination lamp voltage (intensity) iris diaphragm.
Advertisements

ANALYSIS OF THE LIGHT WEIGHT DEFLECTOMETER IN-SITU STRESS AND STRAIN
QR Code Recognition Based On Image Processing
Verification of specifications and aptitude for short-range applications of the Kinect v2 depth sensor Cecilia Chen, Cornell University Lewis’ Educational.
Dept. of Mechanical Engineering, IISc
Effects of Pad Properties on Cu Dishing During CMP Caprice Gray PhD Student, Mechanical Engineering Tufts University, Medford, MA Intel Intern Presentation.
Spectroscopic Ellipsometry University of Texas at El Paso Lynn Santiago Dr. Elizabeth Gardner Chem 5369.
RMS VISION SYSTEMS Innovative Solutions for the Semiconductor Industry Application Note: CD Measurement for FET Features NGS 3500 Advanced Metrology System.
SEM Magnification Calibration. Magnification Errors Proper calibration of the SEM scans (magnification) is primary to metrology. SEM Magnification requires.
October 13, 2006 Kyushu Institute of Technology Kyushu Institute of Technology Prof. Keiichi Kimura Keiichi Kimura, Katsuya Nagayama, Yosuke Inatsu, Panart.
ABRF meeting 09 Light Microscopy Research Group. Why are there no standards? Imaging was largely an ultrastructure tool Digital imaging only common in.
Pore Detection in Small Diameter Bores The University of Michigan, Ann Arbor NSF Engineering Research Center for Reconfigurable Manufacturing Systems.
Instantaneous Fluid Film Imaging in Chemical Mechanical Planarization Daniel Apone, Caprice Gray, Chris Rogers, Vincent P. Manno, Chris Barns, Mansour.
Uncertainty considerations for the calibration of transfer standard radiation thermometers Graham Machin, NPL.
Motion Tracking. Image Processing and Computer Vision: 82 Introduction Finding how objects have moved in an image sequence Movement in space Movement.
Micro PIV  An optical diagnostic technique for microfluidics (e.g. MEMS, biological tissues, inkjet printer head) Requirements: Measure instantaneously.
Friction on a Bowed Violin String Fayette Shaw May 8, 2002.
MULTIPLE MOVING OBJECTS TRACKING FOR VIDEO SURVEILLANCE SYSTEMS.
CMP FtF 9 Nov 06 Friction Updates 1.Last FtF Past issues & solutions 2.Latest data CoF vs. slurry dilution CoF vs. rotation rate Fz vs. slurry dilution.
Research Results Overview Review of former work on instantaneous fluid film thickness measurements Review of former work on instantaneous fluid film thickness.
1 An Analysis of Potential 450 mm Chemical-Mechanical Planarization Tool Scaling Questions L. Borucki, A. Philipossian, Araca Incorporated M. Goldstein,
NA62 Gigatracker Working Group Meeting 2 February 2010 Massimiliano Fiorini CERN.
D EDICATED S PECTROPHOTOMETER F OR L OCALIZED T RANSMITTANCE A ND R EFLECTANCE M EASUREMENTS Laetitia ABEL-TIBERINI, Frédéric LEMARQUIS, Michel LEQUIME.
Forensic Instrumentation
1/20 Obtaining Shape from Scanning Electron Microscope Using Hopfield Neural Network Yuji Iwahori 1, Haruki Kawanaka 1, Shinji Fukui 2 and Kenji Funahashi.
Introduction Chemical mechanical polishing (CMP) is a widely used technique for the planarization of metal and dielectric films to accomplish multilevel.
Examination of some key CMP input parameters on slurry fluid mechanics PI: Chris Rogers Researchers: Jonathan Coppeta Chris Duska Jeremy Javidi Samuel.
Resident Categorical Course
Principal Investigator: Chris Rogers
Vasilios Aris Morikis Dan DeLahunta Dr. Hyle Park, Ph.D.
In-Situ Measurements for Chemical Mechanical Polishing James Vlahakis Caprice Gray CMP-MIC February 20, 2006.
SRC/Sematech Engineering Research Center for Environmentally Benign Semiconductor Manufacturing 1 Micromachined Shear Sensors for in situ Characterization.
Display of Motion & Doppler Ultrasound
The Effect of Wafer Shape in Chemical Mechanical Planarization Researcher: Joseph Lu Principal Investigator: Chris Rogers Corporate Sponsors: Cabot Corporation.
Three Dimensional Photonic Crystals Corey Ulmer. Outline What are Photonic Crystals/Why Important? How They Work Manufacturing Challenges Manufacturing.
Advanced semiconductor detectors of neutrons
INSTANTANEOUS IN-SITU IMAGING OF SLURRY FILM THICKNESS DURING CMP Caprice Gray, Daniel Apone, Chris Rogers, Vincent P. Manno, Chris Barns, Mansour Moinpour,
work for PID in Novosibirsk E.A.Kravchenko Budker INP, Novosibirsk.
CMP Modeling – Current Status Goal is to develop a comprehensive CMP model that complements experimental program Begin with hydrodynamic slurry flow model.
Ultrasound Physics Reflections & Attenuation ‘97.
Chapter 5 Multi-Cue 3D Model- Based Object Tracking Geoffrey Taylor Lindsay Kleeman Intelligent Robotics Research Centre (IRRC) Department of Electrical.
Lidar+Radar ice cloud remote sensing within CLOUDNET. D.Donovan, G-J Zadelhof (KNMI) and the CLOUDNET team With outside contributions from… Z. Wang (NASA/GSFC)
Bubble Bouncing on Solid/Free Surfaces M.R. Brady, D.P. Telionis – Engineering Science and Mechanics P.P. Vlachos – Mechanical Engineering R.-H. Yoon,
Charge Collection and Trapping in Epitaxial Silicon Detectors after Neutron-Irradiation Thomas Pöhlsen, Julian Becker, Eckhart Fretwurst, Robert Klanner,
Chemical Techniques and Developments Mechanical Planarization.
Final Design Review. Outline Brief review of the project Surface photography Conclusions about polishing Methods used to measure surface area and polish.
CMP at Tufts Dan Apone. Issue #1 Cameras had had enough Random dots on images So old that to fix them would require all new internals New cameras researched.
Speed Sensor Calibration
Questions/Problems on SEM microcharacterization Explain why Field Emission Gun (FEG) SEM is preferred in SEM? How is a contrast generated in an SEM? What.
Andrew Chang, David Dornfeld
Extreme Ultraviolet Polarimetry Utilizing High-Order Harmonics Nicholas Herrick, Nicole Brimhall, Justin Peatross Brigham Young University.
Acoustic and Thermal Methods in Detecting Endpoint during Chemical Mechanical Polishing of Metal Overlay for Nanoscale Integrated Circuits Manufacturing.
Measurements of Intense Proton Beams using Optical Transition Radiation Vic Scarpine, Fermilab TIPP 2011 Chicago, IL June 10, 2011.
CMP consumable: Pad Classes of Pad.
Roller Coaster Speed Sensor Calibration. Lab Safety  Do not stand on chairs, or sit or stand on the tables  Know the location of the first-aid kit 
Signal and Image Processing Lab
Presentation Outline Introduction to Chapman Instruments
Caprice Gray MRS Spring Meeting San Francisco, CA March 30, 2005
IncuCyte Training Calibrations and Troubleshooting
Brian Tang and Duane Boning MIT Microsystems Technology Laboratories
Summary of experience with Tevatron synchrotron light diagnostics
Optical Coherence Tomography
Speed Sensor Calibration
Droplet Dynamics of a Flowing Emulsion System in a Narrow Channel
Andrew Chang, David Dornfeld
Section 9: CMP EE143 – Ali Javey.
Acoustic Emission Sensing for Chemical Mechanical Polishing (CMP)
Beam Test Results for the CMS Forward Pixel Detector
Jianfeng Luo and David A. Dornfeld
Jianfeng Luo, David Dornfeld
Presentation transcript:

Pad Characterization Update Caprice Gray Nov. 9, 2006 Cabot Microelectronics Aurora, IL

Outline Review where we were last time Non-DELIF imaging DELIF Contact detection feasibility and preliminary results Thesis Outline DELIF Modeling Experimental Outline Questions/Issue that should be resolved before proceeding forward

Last Meeting Accomplishments Set up beam splitter aligner Replace poor quality optical filters with high quality filters Determined the source of ratio drift by modeling intensity sources for each camera

Source of Ratio Drift Calibration for all previous data sets that show ratio drift. All Components the cameras actually measure Primary Source of ratio drift Experimentally Determined Constants New Ratio Calculation Determined by drift

Imaging Benchmarks: SEM Imaged in 3 regions of a used pad 1.Edge of wafer track (most glazed region) 2.Outside Wafer track (no glazing) 3.Center of wafer track (less glazing)

Imaging Benchmarks: SEM Outside of wafer track Edge of wafer track Center of wafer track In a groove Center of wafer track

Imaging Benchmarks: SEM SEM Image Highest Quality DELIF –depth

Imaging Benchmarks: Confocal Microscopy Similar to DELIF Resolution (scale bar = 160  m) Zoomed image of a pore, a cross section near the pad surface (scale bar = 40  m)

Imaging Benchmarks: Confocal Microscopy 24 images are taken every 2 mm Video start at the deepest layer and progresses to the surface

Rohm and Haas Pad-Wafer Contact Study Confocal Reflectance Interference Contrast Microscopy Images are taken through sapphire. –No slurry –Static Imaging region < 1 mm 2 –Asperity Contact ~ 50  m 2 Pads studied: –IC1000 –VP3000 –Politex –Experimental Tested 0-6 psi, contact 0-6%, experimental contact ~ 20%

DELIF for Contact 360,000+ pixels  2% ~ 7200 pixels 50  m 2 ~ 7-8 pixels (6.7  m 2 /pixel) –Focus must be really good –We are at the resolution limit for our system At this resolution, we are seeing contact region intensity smoothing Data for static DELIF on CMC D100

CMC D100 Imaging Issues Experiment: 50 consecutive static images Image drift correction was nearly 100% of signal Focus is difficult because R a >DOF –Must carefully focus at tops of pixels –Out of focus light bleeds into pixels that are in focus

CMC D100 Imaging Issues D100 Emission FX9 Emission

Thesis Outline Introduction –Why are we looking for pad-wafer contact in CMP –Literature review of experimental pad-wafer contact measurements –Project Goal = detect in-situ pad-wafer contact Methods –What is DELIF, and why use it –System model and calibration techniques –Hardware description –System limitations –Image Acquisition and Processing In-Situ Detection of Pad/Wafer Contact with DELIF during CMP

Thesis Outline Experimental Outline –Description of variables and responses –Post acquisition image interpretation (histogram analysis, etc.) Results and Discussion –Comparison on contact on hard vs. soft pads –Static measurements vs. dynamic measurements –Pressure variation effect on contact % –Relate results to previously studied pad-wafer contact measurements Conclusions –Summary of Experimental results –Contribution of results to current understanding of CMP –Could this technique be expanded to study multiple polishing pad types?

DELIF Modeling Goals –Examine how comparable our actual system is to current DELIF models –Verify our linear calibration technique (Ratio Intensity  Fluid layer thickness) Results –slurry particles  quadratic calibration –As slurry particle concentration  0, calibration  linear Old Model Current System

Experimental Outline Finish Tweaking Optics to get repeatable static data Identify 2 types of polishing pads that will work optically with our system. –Similar R a ~ 4-6  m –High and Low bulk modulus Proceed to DOE –Possible Variables: pressure, pad/wafer velocity, pad type, slurry dilution, pH –Responses: Contact area %, Contact area size, friction signature?

Open Questions Which 2 pads should I focus my study on and will I have a steady supply of them? Does slurry dilution matter? –Accurate depth measurements or minimize chatter? Should I continue to search for a static contact measurement benchmarking technique, or just use (the limited) data from literature? Which experimental variables should I concentrate on? –My variable preferences: pad modulus, pad-wafer speed, down-force