Finnish Custom Lab., Pekka Ravio

Slides:



Advertisements
Similar presentations
Measurement of Gas Concentrations by Mass Spectrometers Günter Peter, N. Müller, W. Neff, Bled April 2012 Quadrupole Mass Spectrometers are gas-specific.
Advertisements

Introducing AnalyzerPro. Chapter 1: Qualitative Analysis.
Protein Quantitation II: Multiple Reaction Monitoring
Improvements in Mass Spectrometry for Life Science Research – Does Agilent Have the Answer? Ashley Sage PhD.
1 The world leader in serving science Proprietary & Confidential WiSIM DIA Method Set-up Orbitrap Fusion MS MS Instrument Control Software v.1.1 SP1.
Welcome! Mass Spectrometry meets Cheminformatics Tobias Kind and Julie Leary UC Davis Course 7: Concepts for LC-MS Class website: CHE Spring 2008.
Mass spectrometry in organic chemistry
TOF Analysis of Bay Water surrounding the Battleship Texas Presented at: SETAC 2013 South Regional Conference Work By: Sue D’Antonio, Joan Stevens, Andre.
Advanced Higher Unit 3 Mass Spectrometry. Mass spectrometry can be used to determine the accurate molecular mass and structural features of an organic.
Pesticide screening LC-QTOF, Agilent. National Food Institute, Technical University of Denmark Disposition National Food Institute –EURL –NRL –Personale.
How Can Orbitrap Technology Help My Food Safety Analysis?
How to identify peptides October 2013 Gustavo de Souza IMM, OUS.
Sangtae Kim Ph.D. candidate University of California, San Diego
LC/MS WORKSHOP IOWA STATE UNIVERSITY Kamel Harrata  Instrument Description  Data Acquisition  Data Processing.
FIGURE 5. Plot of peptide charge state ratios. Quality Control Concept Figure 6 shows a concept for the implementation of quality control as system suitability.
Chemalys September 2009 Chemalys Jan Nordin Chemalys Massworks Extend the Limits of Your LC/MS-System Brukermøte i Massespektrometri 27 mai 2010.
<Instant Notes, D. Kealey & P.J. Haines>
Evaluated Reference MS/MS Spectra Libraries Current and Future NIST Programs.
Tryptic digestion Proteomics Workflow for Gel-based and LC-coupled Mass Spectrometry Protein or peptide pre-fractionation is a prerequisite for the reduction.
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Karl Clauser Proteomics and Biomarker Discovery Taming Errors for Peptides with Post-Translational Modifications Bioinformatics for MS Interest Group ASMS.
Collision-based methods: Electron-based methods: Primary methods for dissociating peptides Collision-based methods: Ion trap collisional activation.
1 Ion Information and Elemental Patterns Chapter 6 (Hoffmann & Stroobant) Chapter 1 (Johnstone and Rose, 1996)
Organic Mass Spectrometry
Q-Exactive LC-MS. TurboFlow technology - Special columns - Complex valving - Extra pump UHPLC -Fast separation -Best separation.
Orbitrap Technology: New Frontiers in Pesticide Residue Analysis
Proteomics and Biomarker Discovery “Research-grade” Targeted Proteomics Assay Development: PRMs for PTM Studies with Skyline or, “How I learned to ditch.
Common parameters At the beginning one need to set up the parameters.
A Phospho-Peptide Spectrum Library for Improved Targeted Assays Barbara Frewen 1, Scott Peterman 1, John Sinclair 2, Claus Jorgensen 2, Amol Prakash 1,
Mass spectroscopy – learning objectives Outline the early developments in mass spectrometry. Outline the use of mass spectrometry in the determination.
Untargeted Metabolomics: Tandem LC-MSMS. Column and Flow Rate Selection Insert Barnes table for flow rates and sensitivity gain. Reverse Phase and Normal.
MS Calibration for Protein Profiles We need calibration for –Accurate mass value Mass error: (Measured Mass – Theoretical Mass) X 10 6 ppm Theoretical.
MS Intro. MS requires gas-phase ions, why? MS uses magnetic and electric fields to control the path of a compound based on mass to charge ratio (m/z)
Temple University MASS SPECTROMETRY FURTHER INVESTIGATIONS Ilyana Mushaeva and Amber Moscato Department of Electrical and Computer Engineering Temple University.
Finding a Needle in a Haystack: Using High Resolution Mass Spectrometry in Targeted and Non Targeted Searching for Food Contaminants Erik Verschuuren.
Multiple flavors of mass analyzers Single MS (peptide fingerprinting): Identifies m/z of peptide only Peptide id’d by comparison to database, of predicted.
Methods for LTQ Orbitrap A Guided Tour with Examples
Secondary Ion Mass Spectrometry A look at SIMS and Surface Analysis.
Analysis of Aerosols Produced From Pyrolysis of Natural Products
Mass Spectrometry Quantitative Mass Spectrometry
Salamanca, March 16th 2010 Participants: Laboratori de Proteomica-HUVH Servicio de Proteómica-CNB-CSIC Participants: Laboratori de Proteomica-HUVH Servicio.
Metabolomics MS and Data Analysis PCB 5530 Tom Niehaus Fall 2015.
Objectives 4 Identify the meaning of software maintenance and it’s importance in the project life cycle 4 Understand why maintenance is needed.
SUPPLEMENTARY FIGURE LEGENDS Figure S1. Sample glycopeptide fragmentation. MS2 scans of the fragmentation of the triply charged glycopeptide at m/z =
Chem. 133 – 4/26 Lecture. Announcements Return graded quiz and additional problem Lab – Lab report deadlines (2:4 – Thursday) Today’s Lecture – Mass Spectrometry.
LTQ Orbitrap Series: Calibration, Tuning, Operations
Constructing high resolution consensus spectra for a peptide library
The world leader in serving science For Research Use Only. Not for use in diagnostic procedures Quantitative Analysis of 4 Immunosuppressant Drugs in Whole.
CU-Boulder Central Analytical Lab Mass Spectrometry Core Facility JSCBB C1B90 Jeremy Balsbaugh & Thomas Lee.
DIA Method Design, Data Acquisition, and Assessment
Objective  To develop methods for analysis of compounds in organic aerosol particles Why is this important?  Environmental impact  Alternative fuels.
Introduction to Liquid Phase Mass Spectrometry
Quantitation using Pseudo-Isobaric Tags (QuPIT) and Quantitation using Pseudo-isobaric Amino acids in Cell culture (QuPAC) Parimal Samir Andrew J. Link.
Data independent acquisition methods for metabolomics Stephen Tate, Ron Bonner AB SCIEX, 71 Four Valley Drive, Concord, ON, L4K 4V8 Canada A high resolution.
Target Analyses in Parallel Reaction Monitoring Mode (PRM)
MS Libraries for Forensics: DART-MS and GC-MS
Accelerating Research in Life Sciences
For Forensic Toxicology use Only
Detection of 3-methylmethcathinone and its metabolites 3-methylephedrine and 3- methylnorephedrine in pubic hair samples by liquid chromatography–high.
Organic Chemistry Lesson 18 Mass spectrometry.
Proteomic, Metabolomic and Lipidomic Research Capability at ICH and ION UCL Metabolomics.
PROTOCOL OPTIMIZATION
Systems Medicine Automated Real-Time Quality Control of LC-MS Metabolomics Data: QC4Metabolomics stanstrup.github.io.
Presentation Title NEMC 2018 Dale Walker, Bruce Quimby Agilent
Schematic of MS1 filtering.
Shotgun Proteomics in Neuroscience
Top-down analysis of intact bovine carbonic anhydrase II by LTQ Orbitrap Velos. Top-down analysis of intact bovine carbonic anhydrase II by LTQ Orbitrap.
Compound is first vaporized and converted into ions, which are then separated and detected. Electron Impact (EI) Mass Spectrometry 1.
Presentation transcript:

Finnish Custom Lab., Pekka Ravio Experiences on developing a screening method for Orbitrap mass spectrometer Esitys käsittelee kemiallista kvalitatiivista orgaanista analytiikkaa tänä päivänä nestekromatografia-massaspektrometrian näkökulmasta. 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Orbitrap Elite ETD Hankinta: olemassa olevasta 15 vuotta vanhasta ioniloukusta > ioniloukku-orbiloukkuun >> hinta >> FIMEAn mukaan tulo Laitteen osien kuvaus: neste – interface –ioniloukku – orbiloukku - ETD 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Orbitrap Elite ETD: schematic Toimintaperiaatteen ero verrattuna moneen muuhun massaspektrometriin: analysoidaan ionipaketteja, ei jatkuvaa ionivirtaa Sähkösumutus interface – kaksiosainen ioniloukku – korkea paine loukussa erilaiset operaatiot – matalapaineloukusta skannataan – omat detektorit – C-trap - Orbitrap toimintaperiaate – HCD cell - ETD

Finnish Custom Lab., Pekka Ravio Pesticide residues screening with Orbitrap Elite Primary instrumental parameters to choose: 1. Mass resolution 15 000, 30 000, 60 000, 120 000 or 240 000 (at m/z 400) 2. Fragmention technique In-source CID, ion trap, HCD all ion fragmentation 3. Collision energy 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Measurement Alternating scanning Full scan, mass range 130 – 900 amu All ion fragmentation in-source CID, mass range 80-900 amu, collision energy 45 V Cycle time around 0.5 s (R = 60 000) > 15 or more scans over UPLC peak External mass calibration 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Alternating scan run, full scan – in source CID scan Zoom 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio EUPT-SM06 2014, pepper + around 30 pestisides Furathiocarb, C18H26N2O5S, M+1 383.16352 383.16287 ∆ m =1,6 ppm Full scan C10H11O2S 195.0474, ∆ m = 4.1 ppm In-source CID 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Screening tests at the moment against a database and MS/MS library only, no validation with pesticide standards Database bought and collected from literature, 450 compounds Data processing software TraceFinder 3.2 Processing against database and MS/MS spectral library (bought) 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Tullilaboratorio, Pekka Ravio Details in compound database 18.3.2015 Tullilaboratorio, Pekka Ravio

Tullilaboratorio, Pekka Ravio TraceFinder processing parameters 18.3.2015 Tullilaboratorio, Pekka Ravio

Finnish Custom Lab., Pekka Ravio Processing with TraceFinder software 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Finding correct fragments ” fragment soup” + library search in-source CID scan 0.019 mg/kg fenhexamid in raspberry Mass resolution 60 000 Fenhexamid MS/MS-library spectra 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Tullilaboratorio, Pekka Ravio Evaluating isotopic pattern, red=meas., blue=theor. Fenhexamid 0,019 mg/kg 18.3.2015 Tullilaboratorio, Pekka Ravio

Tullilaboratorio, Pekka Ravio Screening results, EUPT-SM06 18.3.2015 Tullilaboratorio, Pekka Ravio

Tullilaboratorio, Pekka Ravio Screening results EUPT-SM07 18.3.2015 Tullilaboratorio, Pekka Ravio

Finnish Custom Lab., Pekka Ravio Conclusions Orbitrap Elite Easy to use Stable mass calibration Same mass calibration may be used 1- 3 days (error < 3 ppm) All ion fragmentation with HCD-cell would be nice Data processing with TraceFinder 3.2 Visual outlook very informative Should be able to use several collision energies 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio Principle how the isotopic pattern is evaluated is unclear Overall conclusions Encouraging results All depends on the database A lot of work to build up the database, ”fine tune” it and ”fine tune” the processing parameters + MS/MS library The more compounds you have in database, the more false positives you get The software needs some upgrading and better manuals 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio

Finnish Custom Lab., Pekka Ravio ”Our newest weapon” Customs moneydog Massi Thank You 11. NPRW 1.-2.6.2015, Tallinn Finnish Custom Lab., Pekka Ravio