Dr G Burt (CI), Dr R. Rimmer (Jlab), H. Wang (Jlab) & B. Hall (CI)

Slides:



Advertisements
Similar presentations
RF Cavity Module G. Gosling Dept. of Mechanical Engineering Imperial College London.
Advertisements

30 th September 2004 High Power RF Couplers James Rogers High Power RF Couplers ELSRF Daresbury Laboratory.
Accelerator Science and Technology Centre Prospects of Compact Crab Cavities for LHC Peter McIntosh LHC-CC Workshop, CERN 21 st August 2008.
Slim crab cavity development Luca Ficcadenti, Joachim Tuckmantel CERN – Geneva LHC-CC11, 5th LHC Crab Cavity Workshop.
MICE RF Cavity Design and Fabrication Update Steve Virostek Lawrence Berkeley National Laboratory MICE Collaboration Meeting October 27, 2004.
Status of the 201 MHz Cavity and Coupling Coil Module Steve Virostek Lawrence Berkeley National Laboratory MICE Video Conference March 10, 2004.
201 MHz NC RF Cavity R&D Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory WG3 at NuFact 2004 July 28, 2004.
Design of Standing-Wave Accelerator Structure
The HiLumi LHC Design Study (a sub-system of HL-LHC) is co-funded by the European Commission within the Framework Programme 7 Capacities Specific Programme,
SPX - Cavity WBS U , U , U Genfa Wu SRF Scientist Accelerator Systems Division/RF Group DOE Lehman CD-2 Review of APS-Upgrade.
201 MHz and 805 MHz Cavity Developments in MUCOOL Derun Li Center for Beam Physics Lawrence Berkeley National Laboratory Nufact 2002 Workshop, London,
Cavity design Fundamental parameters : frequency, beta, number of cells (gaps), Eacc Optimisation : R/Q, surface fields / Eacc, Qex, damping of HOMs, kloss,
Cavity package T.Saeki BCD meeting 20 Dec Cavity shape BCD: TESLA shape Pros: small wakefield, HOM thoroughly investigated single-cell: 43 MV/m.
SRF Results and Requirements Internal MLC Review Matthias Liepe1.
RFQ Thermal Analysis Scott Lawrie. Vacuum Pump Flange Vacuum Flange Coolant Manifold Cooling Pockets Milled Into Vanes Potentially Bolted Together Tuner.
201 MHz NC RF Cavity R&D for Muon Cooling Channels
NCSX Vacuum Vessel Joint Design Mike Viola PPPL July 1 st, 2003.
Zenghai Li SLAC National Accelerator Laboratory LHC-CC13 CERN, December 9-11, 2013 HOM Coupler Optimization & RF Modeling.
The design of elliptical cavities Gabriele Costanza.
Rolling Definition: The first process that is used to convert material into a finished wrought product. Thick starting stock rolled into blooms billet.
201 MHz Cavity Fabrication Update Derun Li Lawrence Berkeley National Lab MICE CM24 at RAL, UK June 1, 2009.
Advanced Energy Systems, Inc. Prototype Cavity Fabrication & Test Presented by Ilan Ben-Zvi, BNL for Michael Cole, AES.
KEK R&D for LHC Plan of 800MHz Cavity Calculation of 400MHz Cavity 16 th September 2009, LHC-CC09 at CERN K.Nakanishi.
The HiLumi LHC Design Study is included in the High Luminosity LHC project and is partly funded by the European Commission within the Framework Programme.
Development of the Room Temperature CH-DTL in the frame of the HIPPI-CARE Project Gianluigi Clemente,
1 Spoke cavities for ESS and MYRRHA G. Olry, P. Duchesne (IPN Orsay) SLHiPP-2, 3-4 May 2012, Catania.
2.1 GHz Warm RF Cavity for LEReC Binping Xiao Collider-Accelerator Department, BNL June 15, 2015 LEReC Warm Cavity Review Meeting  June 15, 2015.
1Matthias LiepeAugust 2, 2007 Future Options Matthias Liepe.
56 MHz SRF Cavity and Helium vessel Design
FNAL efforts on LHC Crab Cavity R&D (Proposals for R&D sub-tasks, resources and schedule) Nikolay Solyak.
Main features of PETS tank J. Calero, D. Carrillo, J.L. Gutiérrez, E. Rodríguez, F. Toral CERN, 17/10/2007 (I will review the present status of the PETS.
Page 1 Subashini De Silva Center for Accelerator Science Old Dominion University CAVITY II – RF-DIPOLE CAVITY TEST RESULTS LHC – CC-13, CERN December 9-11,
Compact Crab Cavity Status E. Jensen for WP4 R. Appleby, T. Baer, J. Barranco, I. Ben-Zvi, G. Burt, R. Calaga, E. Ciapala, S. Da Silva, J. Delayen, L.
Update on 201-MHz RF Cavity Construction (Plan) for MICE
DISCUSSION BCP in subassemblies or in fully assembled cavity? Silvia Verdú-Andrés | Brookhaven National Laboratory | 11 December 2015 Thanks to Mike Kelly.
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
UK-Jlab-TechX Designs for the LHC Crab Cavity Dr G Burt Lancaster University / Cockcroft Institute.
IHEP GHz 9-cell Cavity R&D Status and Plan The Third IHEP-KEK 1.3GHz SC Technology Collaboration Meeting Dec. 7-8, 2010, IHEP, Beijing GAO Jie,
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
Progress in unconventional RF structures Dr Graeme Burt Cockcroft Institute, Security Lancaster, Lancaster University.
ESS AD RETREAT 5 th December 2011, Lund “A walk down the Linac” SPOKES Sébastien Bousson IPN Orsay.
Page 1 Jean Delayen Center for Accelerator Science Old Dominion University RF Dipole Cavity Design and Plans LARP Review Fermilab, 10 June 2013.
RF Modeling of the LHC Crab Cavity Zenghai Li SLAC Zenghai Li LARP CM20 April 8-10, 2013.
7th SRF Materials Workshop FRIB SRF Cavities 7/16/12 Chris Compton.
1 SLHiPP2013 meeting – Louvain la Neuve Unité mixte de recherche CNRS-IN2P3 Université Paris-Sud Orsay cedex Tél. : Fax : +33.
PXIE RFQ Engineering Design Steve Virostek Engineering Division Lawrence Berkeley National Laboratory April 10, 2012 Project X Collaboration
Engineering of the power prototype of the ESRF HOM damped cavity* V. Serrière, J. Jacob, A. Triantafyllou, A.K. Bandyopadhyay, L. Goirand, B. Ogier * This.
Engineering Design of Raon SC Cavities Myung Ook Hyun SCL Team Myung Ook Hyun SCL Team.
704 MHz cavity design based on 704MHZ_v7.stp C. Pai
Single Spoke Resonator SSR1 Construction Status P.N.Prakash Inter-University Accelerator Centre, New Delhi, INDIA.
Page 1 Subashini De Silva Center for Accelerator Science Department of Physics, Old Dominion University and Thomas Jefferson National Accelerator Facility.
RISP SSR1 Design - `Balloon’ TRIUMF/PAVAC
Progress on Beryllium Cavity Design R. Fernow, D. Li, R. Palmer, D. Stratakis, S. Virostek as told to Michael S. Zisman Center for Beam Physics Accelerator.
A Four Rod Compact Crab Cavity for LHC Dr G Burt Lancaster University / Cockcroft Institute.
A Four Rod Compact Crab Cavity for LHC Dr C Lingwood for Dr G Burt Lancaster University / Cockcroft Institute.
Beijing Institute of Technology
Fredrik Fors Mechanical Engineering, JLab 04/22/2016
Review of options for crab cavities in LHC:
Crab – RFD prototype: Production Status Update
Hua Shi, Jinhui Chen, Lei Wang, Na Wang, Lihua Huo, Peng Liu, Yan Li
Odu/slac rf-dipole prototype
Design Fabrication and Processing Group H. Padamsee
SPS – RFD Experience and Evolution to LHC
Physics design on Injector-1 RFQ
Developments on Proposed
Double Quarter Wave Crab Cavity
Update of CLIC accelerating structure design
Case study 6 Properties and test of a Superconducting RF cavity
Implications of HOMs on Beam Dynamics at ESS
Discussion on the TDI impedance specifications
Presentation transcript:

Dr G Burt (CI), Dr R. Rimmer (Jlab), H. Wang (Jlab) & B. Hall (CI) Optimum fabrication techniques for prototyping & 4R Crab Cavity Prototyping Status Dr G Burt (CI), Dr R. Rimmer (Jlab), H. Wang (Jlab) & B. Hall (CI)

Cavity Prototype UK have some funding for a cavity prototype from the Cockroft Institute/ EUCARD. An order has been placed with Niowave for a Niobium prototype. This will be a proof of principle to show the cavity can be manufactured and cleaned and hence reach gradient. Vertical cryostat tests will be critical in verifying the cavity concept.

Some fabrication options 1. Sheet metal fabrication of ideal RF design Multiple dies for complex shapes Multiple EBW steps EBW of rods into end plate is a difficult joint, no good sightlines Modest material costs 2. Sheet metal fabrication of modified design for easier welds Offset rods makes welding easier but impedance is low Offset rods tapered inwards restores some efficiency Offset base (bump) should restore efficiency but increase Bpk? 3. Machine end plates and rods from solid Higher material costs (can mitigate with some design changes?) Higher machining costs No critical E-beam welds Better tolerances, more design flexibility (stiffeners etc.) Potential SRF benefits of “large grain” material

1. Conventional fabrication, ideal RF design Fabricate from multiple pressed sections (multiple dies) Multiple multi-axis e-beam welds (esp. rod to end plate joint) May be possible but weld development needed.

1. Conventional fabrication, ideal RF design Fabricate from multiple pressed sections (multiple dies) Multiple multi-axis e-beam welds (esp. rod to end plate joint) May be possible but weld development needed. Almost parallel weld E-beam weld line of sight

2. Conventional fabrication, modified RF design We can reduce the weld complexity by modifying the geometry. Can round the rods but this increases surface fields considerably Can offset the rods at the base and slant the rods to increase the deflecting voltage. Can reduce the fillet radii by introducing a bump but this also increases Bsurf

3. Machine end plates and rods from solid Consider to make major parts from solid Wire EDM pre-forms from ingot Machine all surfaces Add beam pipes and can This allows any material thickness or even a variable thickness. Also stiffeners can easily be added. This will also allow fine detail to be added to avoid multipactor (like the ridges suggested by SLAC for the 800 MHz elliptical cavity) However a substantial lump of Nb ingot is required (£50k worth)

3. Alternative fab, slightly modified RF design Rod profile can be reduced to allow both base plates to be wire etched from a single block of niobium. This saves the amount of Nb required by 20%. Clearance of 2mm between both rods to allow wire EDM.

Wire EDM cutting to separate the electrode blocks

Modified Rod Shape E Abs Reduced tip size leads to a 10% increase in peak surface electric field. Original design Reduced profile Emax @3MV 32.0 MV/m 35.9 MV/m Bmax @3MV 60.5 mT 60.1 mT Transverse R/Q 915 Ohms 963 Ohms B Abs Original Reduced profile

Fabrication of CC-A2 Cavity by CNC Machining Cut fixture plate machined fixture base RRR>250 large grain Nb ingor EDM wire cut Nb template Machine outside surface Machine inside surface with 30um unfinished Milling tool head for last inner finish Machine inner surface on the base Finished first half with 4mm wall thickness Match to other Al model half Outside finish of first half EDM wire cut Nb template for Y WG

Options for fabrication Ideal RF shape, minimum material Many parts, complex welds Option 2: Near ideal shape, easier welds Increased Bpk? Option 3: Ideal or near-ideal RF shape More design options (stiffeners, variable wall thickness, etc.) Higher material and machining costs Possible benefits of large grain material (Q etc.) Other options?

Cavity construction (without couplers) Beam-pipe (rolled) Rods and baseplate machined in one piece from large grain Nb. Shell (rolled)

High pressure rise It is important we can clean all parts of the cavity. Adding ports for demountable couplers also allows access for high pressure rise. We have also added two small ports to allow the water to drain from the base plates.

Additional heating on the ports The lengths of each port has to be carefully chosen to avoid excessive additional losses at the flanges which will make it impossible to measure the Qo of the cavity when testing 50 mm is sufficient for our cavity

Deformation due to pressure Solidworks Simulation Xpress was used to look at the deformation of the cavity under vacuum. Different wall thickness are simulated.

Deformation of the outer can The outer can is sucked in at the edges. This effect could be reduced by bending the outer can or adding ridges. Weak point could be used for tuning the cavity.

Deformation of the outer can The rods bend inwards slightly and expand transversely. The displacement is relatively small (for a reasonable thickness) and has little effect on frequency.

Pressure sensitivity The outer can needs a thickness of at least 3 mm in order to minimise the pressure sensitivity to below 100 Hz/Torr. This is a relatively small dependance and is due to the fact that the frequency is dependant on the cavity length and the cavity is quite stiff to longitudinal pressure.

Microphonics studies FEM studies have begun looking at microphonics. Initially looked at individual components and then progressed into full cavity simulations.

Outer Can Vibration Transverse mode is at a much higher frequency (25 kHz). First vibration mode is a breathing mode. Frequency variation with wall thickness was studied in ANSYS for a cylindrical can. The resonant frequency is between 500-800 Hz for a realistic wall thickness.

Inner Rod Vibration As a starting point conical rods have been studied. The first mechanical resonance is a transverse mode (1.5 kHz). Frequency is only weakly related to wall thickness. Breathing mode also found at 2 kHz

Tuning fork mode As the baseplate has some give, the frequency of the rod vibration is much lower (450 Hz) when we model the full cavity With a 4 mm wall thickness all resonances are pushed up above 450 Hz.

Conclusions Nb 4R Crab cavity prototype order has been placed. The rods will be machined out of a solid Nb ingot. Rod profile modified to allow both sections to be made from a single ingot. 4 mm wall thickness seems appropriate based on microphonics and pressure sensitivity calculations. Machining the rods allows a variable thickness to be used if required. The outer can has several ports to allow additional HPR.