Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.

Slides:



Advertisements
Similar presentations
Scintillator Tile Hadronic Calorimeter Prototype (analog or semidigital) M.Danilov ITEP(Moscow) CALICE Collaboration LCWS04, Paris.
Advertisements

Sci-Fi tracker for IT replacement 1 Lausanne 9. December 2010.
New test result of MPPC M.Taguchi(kyoto).
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
6mm 【 Development of Readout Electronics for MPPC 】 We report the read out electronics of MPPC( Multi-Pixel Photon Counter ). MPPC is a new photodetector.
Photon detection Visible or near-visible wavelengths
Characterization of Silicon Photomultipliers for beam loss monitors Lee Liverpool University weekly meeting.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
GLD Calorimeter Status Oct 学術創成会議 S. Uozumi Shinshu University FJPPL meeting held at the end of September. Preparation underway toward the ECAL.
Reports from DESY Satoru Uozumi (Staying at DESY during Nov 11 – 25) Nov-21 GLDCAL Japan-Korea meeting.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
Fast Detectors for Medical and Particle Physics Applications Wilfried Vogel Hamamatsu Photonics France March 8, 2007.
MPPC Radiation Hardness (gamma-ray & neutron) Satoru Uozumi, Kobe University for Toshinori Ikuno, Hideki Yamazaki, and all the ScECAL group Knowing radiation.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
Light Calibration System (LCS) Temperature & Voltage Dependence Option 2: Optical system Option 2: LED driver Calibration of the Hadronic Calorimeter Prototype.
Future Beam Test Plans of the GLD Calorimeter Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
Study of the Multi-Pixel Photon Counter for ILC calorimeter Satoru Uozumi (Kobe University) Atami Introduction of ILC and MPPC The MPPC performance.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)
Scintillator ECAL for ILC for Calorimeter Review DESY May2007 Tohru Takeshita (CALICE-Shinshu) Idea implementation current status future mile stones.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Development and Study of the Multi Pixel Photon Counter
GLD-CAL and MPPC Based on talks by T. Takeshita and H. K. Kawagoe / Kobe-U 2005-Sep-16 MPPC
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) Feb Beijing Introduction Basic performances Future.
R&D status of the Scintillator- strip based ECAL for the ILD Oct LCWS14 Belgrade Satoru Uozumi (KNU) For the CALICE collaboration Scintillator strips.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
Performance of SiPM Ryuhei Nakamura (Kobe Univ.) GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) Contents ・ Introduction ・ Test results.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Development of Multi-Pixel Photon Counters and readout electronics Makoto Taguchi High Energy Group.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
1 SiPM studies: Highlighting current equipment and immediate plans Lee BLM Quasar working group.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
Prospects to Use Silicon Photomultipliers for the Astroparticle Physics Experiments EUSO and MAGIC A. Nepomuk Otte Max-Planck-Institut für Physik München.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
Fumihiko Ukegawa University of Tsukuba, Japan 6th Joint Korea-Japan ScEcal Meeting September 3, 2010 Kobe University Photo-sensor studies.
Short report on MPPC gain monitoring system S. Uozumi Jun ScECAL meeting At the FNAL BT, having the gain monitoring system for all the channel.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
Beta-ray test for strip scintillator readout MPPC GLD Cal group KEK 06/2/28 (Tue) Niigata university Sayaka IBA.
Performance of Scintillator-Strip Electromagnetic Calorimeter for the ILC experiment Satoru Uozumi (Kobe University) for the CALICE collaboration Mar 12.
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Future Beam Test Plans of the Calorimeter Group Aug 学術創成会議 Satoru Uozumi (Shinshu) for the GLD calorimeter group We are planning to have two beam.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
Progress report on SiPM development and its applications
New Study for SiPMs Performance in High Electric Field Environment
ScECAL+AHCAL+TCMT Combined Beam FNAL
R&D of MPPC for T2K experiment
R&D of MPPC in kyoto M.taguchi.
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction Basic performances and Variation among 800 MPPCs Response curve & Recovery time Summary & Plans

High Gain (10 5 ~10 6 ) Good Photon Detection Efficiency (~15% with 1600 pixel) Compact (package size ~ a few mm) Low Cost Insensitive to magnetic field High dark noise (order of 100 kHz) Input vs output is non-linear ~ 1 mm Depletion region ~ 2  m Substrate substrate p + p-p- Guard ring n - Al conductor p+p+ n+n+ Si Resistor V bias The Multi Pixel Photon Counter (MPPC) - A Geiger-mode avalanche photo-diode - We are testing 1600 pixel MPPC (S MK) for the Scintillator-ECAL readout.

Required performance for the Calorimeter Gain: ~ Best to have 10 6, at least 10 5 Dynamic range: capable to measure ~1000 p.e. –MPPC is non-linear device –Number of pixels and shape of response curve are important Photon detection efficiency enough to distinguish MIP signal Dark noise rate : < 1 MHz good uniformity, small cross-talk Timing Resolution ~ 1 nsec – Necessary for bunch ID, slow neutron separation Stable against bias voltage / temperature / time No influence with 3 T magnetic field Radiation hardness

30 o C 25 o C 20 o C 15 o C 10 o C 0 o C -20 o C –C … Pixel capacity –V 0 … Breakdown voltage 30 o C 25 o C 20 o C 15 o C 10 o C 0 o C -20 o C Gain, Dark Noise Rate, Cross-talk 30 o C 25 o C 20 o C 15 o C 10 o C 0 o C -20 o C Basic performances are almost OK. Further improvements is still ongoing. Over-voltage

Breakdown voltage (V) Pixel capacitance (pF) Variation of Gain over 800 MPPCs Number of MPPCs Device-by-device variation is less than a few %.  No need for further selection or categorization on massive use ! Just need a small tuning of operation voltages. Variation ~ 0.45 V Variation < 4% 800 MPPCs have been measured MPPCs : Dec All measured MPPCs : Feb … Measured after soldered to flat cable.

Dec/06 Feb/07 with flat cable Over-voltage = V bias – V 0 (V) Variation of Dark Noise over 800 MPPCs Noise Rate (kHz) Noise rate is far less than 1 MHz with all the samples. Device-by-device variation is order of ~10 %.

Photon Detection Efficiency MPPC 0.5 mm  hole PMT LED WLSF ~ 16 % Measured by njecting same light pulse into both MPPC and PMT, and comparing light yield. MPPC PMT The 1600-pixel MPPC has comparable P.D.E. with normal photomultipliers (15~20%).

1600 pixel Response curve (simulation) The MPPC is a non-linear device. Response to input light can be theoretically calculated as : However observed response curve has quite different shape. One pixel fire the signal twice due to quick recovery ? Saturation effect Measured Response curve (with charge Integrate ADC)

Recovery Time Measurement MPPC delay LED Inject strong laser (width=52 ps) into the MPPC After delay of  t, inject strong LED light pulse and measure MPPC pulse height. Compare the MPPC output for the LED pulse between with and without the first laser pulse. tt Black … MPPC output for Laser pulse Green … MPPC output for LED pulse Red … Laser + LED Blue … (Laser+LED) - Laser Ratio of Blue / Green shows recovery fraction. Delay  t (sec) Oscilloscope view

Recovery Time Result The curve is fit with a function t D : dead time  : recovery time Delay Recovery fraction (%) V bias (V)  (nsec) t D (nsec) Recovery time of the 1600-pixel MPPC is measured to be 4 ns. Shape does not depend on bias voltage.

Response Curve Response curves taken with various width of LED light pulses Linearity is not limited by number of pixels thanks to quick recovery ! No significant influence from changing bias voltage. Time structure of the light pulse gives large effects in non-linear region. Knowing time structure of input light is important. 8 ns 16 ns 24 ns w = 50 ns 24 ns 8 ns 16 ns 1600 PMT LED w

Summary We are testing the 1600-pixel MPPC for the GLD calorimeter. Measured performance is almost sufficient for the requirement –Comparable gain / P.D.E. with photomultipliers. –Low noise rate (~100kHz) comparing with SiPMs. Variation of gain and noise rate among 800 samples are small enough (<10%). We already entered to a stage of practical application (see SCECAL beam test talk by Daniel) Study of the response curve is currently underway. Plans Establish method to correct for saturation effect with strip scintillators. Study robustness, long-term stability, radiation hardness, magnetic field tolerance, timing resolution. Continue to improve the MPPC (temperature dependence, cross-talk, etc…) collaborating with Hamamatsu.

Backups

Sampling calorimeter with Pb/W - scintillator sandwich structure with WLSF readout Particle Flow Algorithm (PFA) needs particle separation in the calorimeter Fine granularity with strip/tile scintillator Huge number of readout channels –~10M (ECAL) + 4M (HCAL) ! –10K for muon detector Used inside 3 Tesla solenoid Need a new photon sensor which is compact and low-cost, and has enough performance. The GLD Calorimeter

Excellent photon counting ability 0,1,2,3,4,5,6,7,... Photoelectrons ! 1 photoelectron 2 photoelectrons 4 mm 1.3 mm Side 3 mm Front

PhotomultiplierMPPC Gain~ ~10 6 Photon Detection Eff.0.1 ~ 0.2~0.2 for 1600 pix. MPPC Responsefast Photon countingYesGreat Bias voltage~ 1000 V~ 70 V SizeSmallCompact B fieldSensitiveInsensitive CostVery expensive !Not very expensive Dynamic rangeGoodDetermined by # of pixels Long-term StabilityGoodUnknown Robustnessdecent Unknown, presumably good Noise (fake signal by thermions) QuietNoisy (order of 100 kHz) The MPPC has lots of advantages The MPPC is a promising photon sensor, and feasible for the GLD Calorimeter readout !

If you are interested in the MPPC … Yes, now you can buy it ! Number of pixels Sensor size1 x 1 mm 2 Nominal Bias Volt V77 10 V Gain (x 10 5 ) Noise Rate (kHz) Photon Detection Efficiency 65 %50 %25 % Temperature dependence (  V 0 /  T) 50 mV / o C Hamamatsu is starting to deliver the MPPC. See following page for more information: 0_26.html (Numbers from HPK catalog)

Temperature dependence of V 0  V 0 /  T = (56.0 ± 0.1) mV/ o C

Noise rate (kHz ) Cross-talk probability Bias voltage (V) Cross-talk = NR(>1.5p.e.) NR(>0.5p.e.) >0.5 p.e. >1.5 p.e. Noise Rate, Cross-talk

MPPC mass measurement Shaper & Amp MPPC board ADC Bias voltage source Thermostatic chamber (kept at 15 o C) Blue LED DiscriScaler MPPC

Noise rate (kHz) Cross-talk probability Error bars mean variation (RMS) over 400 MPPCs 39% 27% 23% 21% 23% 30% RMS/Mean=60% 70% 48% 59% 63% 58% 47% RMS/Mean=27% Variation of Noise Rate, Cross talk over 400 MPPCs Bias voltage (V)

Photon Detection Efficiency by Hamamatsu