Qualified Partner Program RJ45 Cords Felice Guarna, Training Program Manager Wetzikon, Dec. 2005.

Slides:



Advertisements
Similar presentations
Cabling system components
Advertisements

BOSE® link – Music Throughout Your Home
Multi-Drop Sealed Connector System Introduction Fully sealed to IP66 & 67, the Multi-Drop Sealed Connector System uses cable-pierce technology to offer.
+ Straight-Through Cable Construction Lab 4. + Data Transmission In data transmission system, the transmission medium is the physical path between transmitter.
HIL Connector An introduction to the new HIL wire-to-wire, crimp style connector series.
Electronics. Solid snap together electronic connectors.
JWPF Connector Wire –to-Wire Wire –to-Board
Qualified Partner Program Installation Cables Felice Guarna, Training Program Manager Wetzikon, Dec
Qualified Partner Program R&M FO patch panels for LAN applications Felice Guarna, Training Program Manager Wetzikon, January 2006.
Qualified Partner Program FO Terminal Outlets Felice Guarna, Training Program Manager Wetzikon, September 2005.
TIA-1005 (Proposed by TR-42.9) Industrial Cabling Standard Pete Lockhart Anixter Manufacturing IT Forum Cleveland, Ohio May 20-21, 2008.
Infrastructure and components. Cable The cable and components used in structured cabling systems is defined in the standards –EIA/TIA 568 x There are.
VS Compact Applications Enrique Rodriguez Head of Product Management Distribution Systems.
Patent Pending The strong link for data networks WHAT IS OUR SOLUTION? RJ45 Plug Boot Cable 2 Plastic Optical Fibres ( POF) Our Solution:
111 © 2002, Cisco Systems, Inc. All rights reserved. Trim out phase steps Cutting cables to length Labeling cables Dressing cables Terminating cables Installing.
NETWORK DESIGN Customer requirements Network topologies Cable choice Hardware TSB 75 TSB72.
Data Center Global Telecommunications Cabling Standards Landscape and Latest Developments Jonathan Jew - J&M Consultants, Inc. Chair TIA TR-42.6 Telecom.
Qualified Partner Program R&Mfreenet fiber - LAN F.O. installation cable Felice Guarna, Training Program Manager Wetzikon, January 2006.
1 Fiber Optics FIBER OPTIC PATCH PANELS. 2 Fiber Optics Just like our copper cable plant the fiber cable plant incorporates many of the same hardware.
Guide to Network Cabling Fundamentals
Cabling Systems NEWLINK ARE YOU READY FOR THE… TECHNOLOGY RACE?
Die Cast – Nickel Die Cast – Black Metalized Plastic Black Plastic Grey Plastic Plastic - Assorted Colors –Available only on 972 Series.
Qualified Partner Program R&M RJ45 Connectors Felice Guarna, Training Program Manager Wetzikon, Dec
1 Project # 2 Steve Klesper Tom Ondick Garry Meadows Aaron Hurt Tim Wade.
Copper Solutions. Nexans Cabling Solutions 04 September LANmark5 EVO Based LANmark 6 EVO Based Screened & Unscreened LANmark 6A EVO Based, Screened.
PAL WIRE-TO-WIRE CONNECTOR SERIES Purpose: To introduce the PAL wire-to-wire connector series.
Electrical Safety in Construction. Objectives In this course, we will discuss the following: Common electrical hazards Standards relating to those hazards.
Crossover Cable Construction
HORIZONTAL SUBSYSTEM. CABLING SYSTEM Horizontal Subsystem The Horizontal cabling subsystem is the part of the Signamax Cabling System that extends from.
Copper Media Describe the specifications and performances of different types of cable. Describe coaxial cable and its advantages and disadvantages over.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
سليمان صلاح أبوطير عمر جهاد الحايك محمد كمال المدهون رشدي أديب حميد محمد نهيل العثماني محمد أسعد أبوالكاس فاطمة طاهر لولو فاطمة طاهر لولو.
Module 3: Networking Media Safe Handling and User of a Multimeter Voltage Measurement Resistance Measurement Series Circuits 3.1.9a.
ANSI/TIA-568-C Generic Telecommunications Cabling APPROVED: FEBRUARY 2, 2009 This template can be used as a starter file for presenting training.
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
SIGNAMAX CABLING SYSTEM COMPONENTS. TRANSMISSION MEDIA Twisted Pair.
Page 1 - © Richard L. Goldman RJ-45 Termination ©Richard L. Goldman June17, 2002.
CABLING SYSTEM ADMINISTRATION. Administration Concept.
SIGNAMAX WARRANTY SYSTEM. Signamax Warranty Types Signamax Connectivity Systems offers its customers a versatile system of component and system warranties.
Qualified Partner Program Outlets
INTRUSION ALARM TECHNOLOGY
CABLING SYSTEM INSTALLATION. Installation Quality The quality of installation is the most serious problem in implementation of the telecommunications.
© Cisco Systems, Inc. All rights reserved. Cisco Public ITE PC v4.1 Chapter5 1 Computer Networks.
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
Cabling Systems NEWLINK ARE YOU READY FOR THE TECHNOLOGY RACE ?
Boosting a Car Battery Cables should have sufficient length (12-16-ft) with #6 gage stranded wire and well-designed clips. Follow the proper sequence of.
COPPER AND FIBER REVIEW
XMA Connector Purpose: Objectives: Content:
TELECOMMUNICATIONS SPACES
Charging Cart Instruction & User Manual EnTrans Technology Co., Ltd.
Legrand Cabling System LCS
SIGNAMAX CABLING SYSTEM. Signamax Cabling System The Signamax Cabling System Design Principles and Installation Practices are based on the requirements.
NETWORKING MEDIA b Shielded twisted-pair - 2 pair, 150 ohm b unshielded-twisted pair - 4 pair, 100 ohm b fiber optic cable - 2 fibers b coaxial cable -
VisiPatch 110 System VisiPatch. VisiPatch System - Key Features.
This courseware is copyrighted © 2016 gtslearning. No part of this courseware or any training material supplied by gtslearning International Limited to.
AT&T Cabling Systems AT&T CopperLine November 2014.
SERVICE TRAINING EXPERT ALPHASTAR 1132 © MAO-SE-TC 1132_SE_EX_Handout_EN_12_  Collision protection switch  Collision protection switch retrofit.
D40ML Series – Magnetic Locking RFID Safety Interlock Switches
Lecture 2 unit 1.
COMMUNICATION SYSTEMS IN BUILDINGS/CAMPUSES
What is wrong with these plugs? L N E L N E L N E.
ETHERNET CABLE TYLER THORNBURG LTEC STRIPPING AND CUTTING First you will need to strip the wire. I used scissors to cut off the rubber around.
For prices please contact us
How to wire Ethernet Cables
JWPS Connector Wire-to-wire and Wire-to-board
Mains Plug Wiring: Brown lead Live Blue Lead Neutral
Ethernet Cable Local Area Networks.
LAN Cabling CCNA Instructor Training Course October 12-17, 2009
LESSON NO:11 Network Cabling Making connections with Cat5 Way cool! SMI-Lecturar Samreen Javed.
Presentation transcript:

Qualified Partner Program RJ45 Cords Felice Guarna, Training Program Manager Wetzikon, Dec. 2005

Cords 2 Dec Rj45 cords The generic name CORDS defines a flexible cable, terminated with 2 Rj45 plugs. Depending on its function and the position it has in the cabling system, the cord assumes different name:  Patch cords  Work area cord  Equipment cord  Consolidation point cord Generic Cabling System Standards define for each function a set of rules

Cords 3 Dec  Patch cords (generally flexible cable)  Used to cross connect- limited in length- max 5m generally flexible cable  Work area cord (generally flexible cable)  Used to connect Equipment to TO- length up to 20m  Equipment cord (generally flexible cable)  Used to connect Active components in the Rack- limited to 5m max.  Consolidation point cord (generally flexible cable but could be solid)  Used to connect T.O. or M.U.T.O. to Consolidation Point – part of Permanent Link design- max length not specified but calculated according to formula in the Standard Rj45 cords

Cords 4 Dec RJ45 cords R&Mfreenet system offer different lines of cords:  Cat. 5e patch cords (CLASSICsystem)- - IDC plug  Cat. 6 patch cords (STARsystem) – IDC plug  R&Mfreenet Customised patch cords – IDC plug  Commercial line – pierced contact

Cords 5 Dec RJ45 patch cords (not Commercial line)  All R&Mfreenet cords are designed, manufactured and tested according to latest Cabling Standards. They fulfil the requirements of class D (classic) or E (star) according to latest ISO/IEC and EN as well as TIA/EIA.  Except Commercial Line, R&Mfreenet Cords are manufactured using R&Mfreenet Cat. 6 plug and proper category (Cat. 5e and Cat. 6) flexible cable. Cat. 6 plug Cat. 5e flexible cable Cat. 6 flexible cable Cat 5e (Classic System) Cat 6 (Star System)

Cords 6 Dec RJ45 patch cords Features  All cords by R&Mfreenet are supporting Gigabit Ethernet.  Patented Pair Crossover design will assure consistency of NEXT and RL performances.  Pairs on double layer increases separation of conductors and reduces NEXT.  100% stringent testing and superior peformance will assure R&Mfreenet cords will outperform limits of the Standards for their Class.  Support all R&Mfreenet security features. Recommended wiring Pin assignment of RJ45 plugs 1 8 1

Cords 7 Dec RJ45 R&Mfreenet cords Colored replaceable Clip Special strain relief assuring Bending radius on 360° Plastic housing color defines Class: Transparent Class D Blue Class E Optional Labeling area

Cords 8 Dec RJ45 R&Mfreenet cords Features  8 Color clips.  Cord available in U/UTP and SF/UTP flexible cable, LS0H and LSFR0H respectively.  Class D U/UTP Cords available in PVC also.  UL/CSA approved  Screened Cords available with ground bonded on both plugs or on one plug only.  Cords ready to be used on safe Lock  Available in lengths of 0.5 up to 20 m

Cords 9 Dec RJ45 Cat. 6 cords Features  Every single patch cord is tested for transmission performance (RL + Next) and marked with quality stamp.  Can be used for Cat. 5e applications (fully backwards compatible).  New strain relief concept to maintain cord geometry and reduce RL.

Cords 10 Dec Accessories (not for commercial line)  Safety clip for patch cords Prevents accidental disconnections  Data safety locks Prevents wrong connections by means of mechanical keying.

Cords 11 Dec R&M „Commercial cords“  Only the standard assortment is available ( No Customized versions)  Not in R&Mfreenet catalogue  Not supporting R&Mfreenet Security system  All Patch cords are real Cat.5e (2002)  All Patch cords have modified booth to preserve cable geometry  R&Mfreenet label  R&Mfreenet design  R&Mfreenet quality  R&Mfreenet warranty

Cords 12 Dec Color coding for ALL R&M cords  The color coding can be snapped onto the strain relieves within seconds. In case of cord change, color clip is quickly exchanged. Opening allows quick insertion/removal on strain relief Colour coding clips