Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)

Slides:



Advertisements
Similar presentations
New test result of MPPC M.Taguchi(kyoto).
Advertisements

Comparison of 3 types of scintillator strips and 2 types of reflector films Miho NISHIYAMA Shinshu-U Light yield of 3 scintillator strips have been measured.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan 1.Introduction 2.Recent.
Study of the MPPC Performance - contents - Introduction Fundamental properties microscopic laser scan –check variation within a sensor Summary and plans.
Performance of MPPC using laser system Photon sensor KEK Niigata university, ILC calorimeter group Sayaka IBA, Hiroaki ONO, Paul.
Study of Photon Sensors using the Laser System 05/7/12 Niigata University, Japan Sayaka Iba, Editha P. Jacosalem, Hiroaki Ono, Noriko.
1 A proposal of new simple system for testing a large number of MPPC for the R&D phase of GLD calorimeter 2007/Feb/6 ACFA ILC Workshop ICEPP, University.
Scintillator based muon upgrade / BELLE Super B Factory Workshop In Hawaii Jan 2004, Honolulu, Hawaii 1.Scintillator strip option 2.Geiger photodiodes.
Yannick Geerebaert LLR Ecole Polytechnique CNRS IN2P3 Palaiseau France INGRID Meeting / March 2008 / France March 2008 status MPPC TEST LLR S.
6mm 【 Development of Readout Electronics for MPPC 】 We report the read out electronics of MPPC( Multi-Pixel Photon Counter ). MPPC is a new photodetector.
The Transverse detector is made of an array of 256 scintillating fibers coupled to Avalanche PhotoDiodes (APD). The small size of the fibers (5X5mm) results.
MPPC R&D status Kobe Univ. CALICE collaboration meeting Yuji SUDO Univ. of Tsukuba ~ contents ~ Introduction Linearity curve Recovery time.
GLD Calorimeter Status Oct 学術創成会議 S. Uozumi Shinshu University FJPPL meeting held at the end of September. Preparation underway toward the ECAL.
Selection of Silicon Photomultipliers for ILC Analogue Hadron Calorimeter Prototype Lay-out * ILC Hadron Calorimeter prototype with SiPM readout * Selection.
CALICE Meeting DESY ITEP&MEPhI status report on tile production and R&D activities Michael Danilov ITEP.
MPPC Radiation Hardness (gamma-ray & neutron) Satoru Uozumi, Kobe University for Toshinori Ikuno, Hideki Yamazaki, and all the ScECAL group Knowing radiation.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
SiPM: Development and Applications
The MPPC Study for the GLD Calorimeter Readout Introduction Measurement of basic characteristics –Gain, Noise Rate, Cross-talk Measurement of uniformity.
Scintillation hodoscope with SiPM readout for the CLAS detector S. Stepanyan (JLAB) IEEE conference, Dresden, October 21, 2008.
The Scintillator ECAL Beam Test at FNAL Adil Khan International Linear Collider Workshop 2010 LCWS10 & ILC10, Beijing, China CALICE Scintillator ECAL group.
The Scintillator ECAL Beam Test at FNAL K. Kotera, Shinshu-u, 1st October 2009 CALICE Scintillator ECAL group; Kobe University, Kyungpook University, the.
MPPC update including plastic connector T2K experiment collaboration meeting 2007/4/18 (Wed) S.Gomi T.Nakaya M.Yokoyama ( Kyoto University ) T.Nakadaira.
R&D of MPPC for T2K experiment PD07 : Photosensor Workshop /6/28 (Thu) S.Gomi T.Nakaya M.Yokoyama H.Kawamuko ( Kyoto University ) T.Nakadaira.
Study of the MPPC performance - R&D status for the GLD calorimeter readout – Nov 6-10.
Study of the Multi-Pixel Photon Counter for ILC calorimeter Satoru Uozumi (Kobe University) Atami Introduction of ILC and MPPC The MPPC performance.
MEG II 実験 液体キセノンガンマ線検出器に用いる 光検出器 MPPC の 実装に向けた最終試験 家城 佳 他 MEG II collaboration + 九大の方々.
1 SiPM Gain Test SiPM Multiple APD pixels operating at Geiger mode. Output is the sum of the outputs from all APD pixels. Advantages Compact size High.
1 NIU Integrated Readout Layer Kurt Francis NICADD Northern Illinois University March 19, 2014.
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group May 29 – Jun 4 DESY Introduction.
1 Development of Multi-Pixel Photon Counters (1) S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira, K.Yoshimura, (KEK) Oct
1 MPPC update S.Gomi, T.Nakaya, M.Yokoyama, M.Taguchi, (Kyoto University) T.Nakadaira (KEK) Nov KEK.
Development and Study of the Multi Pixel Photon Counter
Study of the MPPC for the GLD Calorimeter readout Satoru Uozumi (Shinshu University) Feb Beijing Introduction Basic performances Future.
MPPC status M.Taguchi(kyoto) T2K ND /7/7.
Development of Multi-Pixel Photon Counters(MPPC) Makoto Taguchi Kyoto University.
MPPC Saturation Corection Idea -> how to do. MPPC Gain measurement To apply saturation correction to the beam data, all MPPC are needed to be calibrated.
Performance of SiPM Ryuhei Nakamura (Kobe Univ.) GLC calorimeter group (KEK, Kobe, Konan, Niigata, Shinshu, Tsukuba) Contents ・ Introduction ・ Test results.
Status of photon sensor study at Niigata University -- SiPM and MPPC -- Photon sensor mini workshop 05/9/16 University Niigata University.
Development of Multi-Pixel Photon Counters and readout electronics Makoto Taguchi High Energy Group.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group (KNU, Kobe, Niigata, Shinshu, ICEPP.
E.Guschin (INR,Moscow) 3 May 2006Calorimeter commissioning meeting Status of PRS/SPD detector Cosmic test results Installation/tuning of monitoring system.
FSC Status and Plans Pavel Semenov IHEP, Protvino on behalf of the IHEP PANDA group PANDA Russia workshop, ITEP 27 April 2010.
Multipixel Geiger mode photo-sensors (MRS APD’s) Yury Kudenko ISS meeting, KEK, 25 January 2006 INR, Moscow.
R&D of Calorimeter using Strip/Block Scintillators with SiPM
Scintillator tile – SiPM development at ITEP Michael Danilov, ITEP CALICE Meeting, Casablanca, 23 Sep 2010.
SiPM for CBM Michael Danilov ITEP(Moscow) Muon Detector and/or Preshower CBM Meeting ITEP
DESY BT analysis - MPPC Saturation Correction - S. Uozumi Feb Sci-ECAL meeting 1.MPPC Gain Measurement (with LED data) 2.Inter-calibration of readout.
December Status of MRS photodiodes ND280 Convener’s Meeting, 9 June 2006 Yury Kudenko INR, Moscow.
Systematics on ScECAL 1 st prototype DESY Apr , CALICE Satoru Uozumi for the CALICE collaboration NIM A, 763 (2014) 278.
Performance of new MPPC Nov. 21 Korea-Japan joint meeting Takashi Maeda Hideki Yamazaki Yuji Sudo (University of Tsukuba) --- Contents ---
Jet Energy Measurement at ILC Separation of jet particles in the calorimeter is required for the PFA  Fine granular calorimeter is necessary. Particle.
The Multi-Pixel Photon Counter for the GLD Calorimeter Readout Jul Satoru Uozumi University of Tsukuba, Japan for the GLD Calorimeter.
Study and Development of the Multi-Pixel Photon Counter for the GLD Calorimeter Satoru Uozumi (Shinshu, Japan) on behalf of the GLD Calorimeter Group Oct-9.
Status of NEWCHOD E.Guschin (INR), S.Kholodenko (IHEP), Yu.Kudenko (INR), I.Mannelli (Pisa), O.Mineev (INR), V.Obraztsov (IHEP), V.Semenov(IHEP), V.Sugonyaev.
Upgrade of the MEG liquid xenon calorimeter with VUV-light sensitive large area SiPMs Kei Ieki for the MEG-II collaboration 1 II.
Development of UV-sensitive MPPC for upgrade of liquid xenon detector in MEG experiment Daisuke Kaneko, on behalf of the MEG Collaboration µ γ Liquid xenon.
Study of the MPPC for the GLD Calorimeter Readout Satoru Uozumi (Shinshu University) for the GLD Calorimeter Group Kobe Introduction Performance.
Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK) for KEKDTP photon sensor group.
M.Taguchi and T.Nobuhara(Kyoto) HPK MPPC(Multi Pixel Photon Counter) status T2K280m meeting.
Performance of 1600-pixel MPPC for the GLD Calorimeter Readout Jan. 30(Tue.) Korea-Japan Joint Shinshu Univ. Takashi Maeda ( Univ. of Tsukuba)
Development of Multi-Pixel Photon Counters (1)
Progress report on SiPM development and its applications
Characteristics of S12045(X) photon sensors for GlueX
ITEP&MEPhI status report on tile production and R&D activities
R&D of MPPC for T2K experiment
Efficiency Study of Prototype Scintillator for INGRID
MPPC for T2K Fine-Grained Detector
R&D of MPPC in kyoto M.taguchi.
The MPPC Study for the GLD Calorimeter Readout
Presentation transcript:

Development of Multi-pixel photon counters(2) M.Taguchi, T.Nakaya, M.Yokoyama, S.Gomi(kyoto) T.Nakadaira, K.Yoshimura(KEK)

Contents Application of MPPC for T2K experiment device-by-device variation of gain, noise rate Calibration method summary

precise measurement of  disappearance search for  appearance T2K experiment J-PARC Super KamioKande main goal

Application of MPPC for T2K use scintillator+wave length shifting fiber for almost all near detectors  need compact & low cost photo sensor OffAxis detector is put under 0.2T environment  need tolerance of magnetic field OffAxis detector OnAxis detector MPPC satisfy these requirements! target SK

ItemSpec.status Area1.2×1.2mm 2 HPK now working No. of pixel100/400OK gain~10 6 OK Noise rate with 0.5p.e. threshold <1MHzOK crosstalk<5%HPK now working PDE>30%/>15%OK Timing resolultion~2,3nsOK requirement from T2K ※ PDE…. without/with including the loss of light due to current package of MPPC fiber MPPC ~0.5mm 1mm

Device-by-device variation Basic performance of MPPC is almost satisfactory  next, device-by-device variation of basic performance when mass production? if variation is large, - cannot apply the same bias voltage for all MPPCs - readout electronics needs to cover more dynamic range We measured the device-by-device variation of gain, noise rate for seven 100 and 400 pixel samples which are the same types Motivation

tested samples Number of pixels Pixel pitch(μm) AreaOperating voltage Geometrical efficiency x1.0mm V64% x1.0mm V55% latest samples which was delivered at this month

device-by-device variation ~gain~ 69.4V70.4V69.4V70.4V variation 3.0×10 6 ~3.6×10 variation 9.0×10 5 ~ 1.3×10 1.0× × × × pixel 400pixel 20 ℃ different colors correspond to data at different samples

device-by-device variation ~ 0.5p.e.threshold noise rate ~ 69.4V70.4V 69.4V70.4V variation variation 100pixel 400pixel 100kHz 500kHz 100kHz 400kHz 20 ℃

device-by-device variation ~ noise rate as a function of V-V bd ~ V-V bd pixel400pixel 100kHz 500kHz 400kHz 100kHz V bd : breakdown voltage(derived by linearly extrapolating the gain-voltage curve to the point where gain becomes zero) V bd V Gain noise rate as a function of V-V bd takes the same value for different samples  variation of noise rate comes from variation of breakdown voltage 20 ℃

device-by-device variation ~breakdown voltage~ numberV bd numberV bd pixel 400pixel variation of V bd is about 1V  a bit large! we request HPK to make this variation small we are going to check the variation for ~500 samples next March 20 ℃

Calibration test Motivation Gain, PDE, crosstalk of MPPC are all sensitive to the temperature and bias voltage It is necessary to calibrate the variation of gain, PDE,crosstalk when temperature or bias voltage changes MPPC Signal ∝ Gain(T,V) x PDE(T,V) x 1-crosstalk(T,V) 1 T : temperature V : bias voltage I will present two calibration methods (explain each method later)

Set up for calibration test 1/2inch PMT cosmic-ray 1mm φfiber MPPC2(100) MPPC1(100) MPPC3(400) MPPC4(400) scintillator blue LED put scintillators in four layers inserted fibers are viewed by four MPPCs(two are 400 pixel and two are 100pixel) change temperature intentionally like 20 ℃  25 ℃ The same bias voltage (69.0V) is applied to four MPPCs two triggers(cosmic,LED) temperature chamber ※ we used old samples for this test

Calibration Method 1 gaincrosstalkPDE(MPPC)/QE(PMT) V-V bd V bd : breakdown voltage V: bias voltage gain, PDE, crosstalk are all functions of V-V bd (independent of temperature) can calibrate all parameters by monitoring only one parameter(for example, gain) different colors correspond to data at different temperatures

calibration constant= gain x PDE x MIP ADC counts 1- crosstalk 1 estimate the variation of V-V bd estimate the variation of PDE(V-V bd ),crosstalk(V-V bd ) 0p.e. 1p.e. LED trigger data measure the variation of gain Calibration Method 1 0p.e. 1p.e. LED trigger data gain V-V bd crosstalk PDE(MPPC)/QE(PMT) V-V bd

Calibration Method2 MIP ADC count ∝ gain(T,V)×PDE(T,V)× LED ADC count ∝ gain(T,V)×PDE(T,V)× 1 1- crosstalk(T,V) 1 MIP ADC count LED ADC count calibration constant = MIP ADC count LED ADC count cosmic rayLED Inject the light from LED with the same light intensity as MIP light yield

Stability of device response after calibration(100pixel) +3% -3% 20 ℃ 25 ℃ method1 +3% -3% +3% 20 ℃ 25 ℃ method2 calibration constant precision of calibration is ~3% by both methods response of other three samples is also well calibrated only the errors of MIP ADC count and gain are included hour

MPPC1(100)MPPC2(100)MPPC3(400)MPPC4(400) Method12.5%2.3%3.8%3.1% Method22.5%1.3%2.4%1.4% We need to guarantee the stability of light from LED for method 2 measure the PDE, cross-talk rate as a function of V-V bd before installation for method 1 Summary and discussion about calibration test Stability of each MPPC response after calibration in RMS/mean calibration is possible by two methods (the precision of calibration is better for method 2)

Summary use of MPPC at T2K is determined device-by-device variation among seven samples is a bit large  we request HPK to make this variation small we are going to check the variation for ~500 samples next March calibration is possible by two methods  it is necessary to test much larger number of samples

supplement

measurement of gain 0p.e. 1p.e. MPPC gain = 1p.e. charge e(1.6× ) ADC distribution blue LED

measurement of noise rate count the rate above 0.5 and 1.5p.e. threshold without external light 0.5p.e. 1.5p.e.

Basic performance ~crosstalk~ ・ Assuming 2p.e. noise is caused by crosstalk of 1p.e noise(accidental coincidence of 1p.e noise is subtracted) Cross-talk rate = Data taken by random trigger 0.5p.e. 1.5p.e.

measurement of PDE MPPC(total area 1mm 2 ) ½ inch PMT 1mmφslit MPPC x Y slit PMT The view from this side ・ only the light going through 1mmφslit is detected ・ Scan the MPPC and PMT with moving stage and search the position with maximum light yield ・ The ratio of MPPC p.e. to PMT p.e. is taken as relative PDE of MPPC to that of PMT WLS fiber blue LED

Crosstalk assume the crosstalk takes place sequentially at the same probability 1p.e. looks like: 1+(crosstalk)+(crosstalk) 2 + ‥ = correction factor of crosstalk= 1 1-crosstalk 1

setup for calibration test

MPPC(Multi pixel photon coutner) 100~1000 APD pixel in 1mm 2 Each pixel operates as Geiger mode (independent of input light) The output is a sum of all the APD signals Compact Low-cost Insensitive to the magnetic field Low bias voltage :40~75V High gain:10 5 ~10 7 MPPC characters:

Raw signal and ADC distribution

Where does the requirement to MPPC come from? ItemrequirementFrom where Area1.2x1.2mm 2 To match 1.0mm fiber No. of pixel100/400To keep dynamic range up to ~100p.e. gain~10 6 To set disc. threshold with reasonable precision Noise rate<1MHzTo reduce accidental hit to TDC crosstalk<5%To reduce the noise rate with 1.5p.e. threshold PDE>30%/>15%To keep as large PDE as that of PMT at least Timing resol.2-3nsNot so meaningful requirement