Lanzo Safety Lancet Copyright©2003~2011 by GMMC All Rights Reserved The integrated single-use safety lancet.

Slides:



Advertisements
Similar presentations
Credit Card Organizer Alex Jury David Turner EN100 Spring 2006.
Advertisements

What you need to know about ASPIJECT ® & local dental anaesthesia Quality you can Feel! ASPIJECT.
Ceiling Lift Inservice. WE’RE THE COMPANY THAT BRINGS YOU… Ceiling Lifts.
Finger stick blood collection into Microtainer®. Universal precautions Assume that all human blood is potentially infectious for HIV, hepatitis, and other.
SOL-CARE ® Luer Lock Safety Syringe. SOL-MILLENNIUM Medical introduces the new SOL-CARE ® luer lock safety syringe, a product of the SOL-CARE® safety.
Training Slides Clinical Employees. Sharps Injury Prevention Where do You fit into the puzzle of sharps safety????
DBS preparation from finger stick blood in Microtainer®
Module 3: Marking out and Hand Tools
Fingerstick Procedure
THE M-9 9MM SERVICE PISTOL
Preventing Back Injuries: Home Health Care Workers
KENTAMED Radio B is a cutting-edge technology 4MHz radiofrequency surgery unit. It combines the well-known tissue spearing effects of the radiofrequency.
111 LESSON 7 How to give an injection with Sayana Press.
Naloxone formulation update
Always practice proper hand hygiene and change gloves between each person. Label each individual piece of equipment with the resident’s name to prevent.
Module 8: Blood Collection – Finger Prick
Infection Prevention in Point of Care Testing. Point of Care Testing (POCT) Diagnostic testing at or near the site of patient care Uses portable handheld.
Nova Stat Strip Update.
Emergency care for Musculoskeletal system. The Skeletal System The Musculoskeletal system consists of: - Bones (skeleton) - Joints - Cartilages - Ligaments.
Page 1 of 28 Modular Instruments for Suction and Irrigation Versatile and Precise Presentation Suction- and Irrigation Systems presents:
2.01 Patient and Healthcare Professional Safety Considerations
Laboratory Training for Field Epidemiologists Best infection control measures for sampling venous and capillary blood WHO intermediate recommendations.
Starting a Peripheral IV Principles of IV Therapy BSN336 Lab.
Best Infection Control Practices for ID, SC, and IM Injections Recommendations of the SIGN Working Group on Best Practices Geneva, October 2000 SIGN.
Different Types of Blood Glucose Devices Accu-Chek Active LifeScan OneTouch UltraSmart Bayer's Contour.
Fingerstick Blood Collection into a Microtainer for PNG
Industrial Automation
BLOOD GLUCOSE MEASUREMENT Mary Clynes, Colleen O’Neill and Sara Raftery Chapter 19.
Gail Vanairsdale Global Clinical Education Manager Enlite Sensor Insertion.
Administration of Vaccine via Intramuscular Route
Fingerstick Proficiency Training. Overview  Fingerstick waiver form  Background presentation  Universal Precautions  Demo  Participants do 5 sticks.
Chapter 16 Body Mechanics
111 LESSON 2 What is Uniject ™ ? Uniject is a trademark of BD.
QUALITY ASSURANCE GUIDELINES HONWANI F.J Q.A ON RAPID HIV TESTING 10 AUGUST 2010.
COPYRIGHT SILCA SpA 2007 Bravo ProfessionalSilca S.p.A. Bravo Professional.
All sizes commonly used are all sizes commonly used are available (9 sizes and lengths) available (9 sizes and lengths) w/ and w/o infusion port w/ and.
Quality Reliable Safe July 2007 Medical Devices Division Features and Benefits Combiguard II® High Pressure Irrigation Splash Guard Combiport® Wound Irrigation.
Electronic Injector for use with most standard and prefilled syringes Copyright© September 2015.
 Collecting and Testing Specimens Copyright © 2012 by Mosby, an imprint of Elsevier Inc. All rights reserved.
Copyright © 2008 Delmar Learning. All rights reserved. Unit 15 Patient Safety and Positioning.
Barcode Technology in healthcare Nowadays, published reports illustrate high rates of medical error (adverse events) and the increasing costs of healthcare.
Blood Specimen Collection
Bravo Maxima.
for use with most standard and prefilled syringes
CutMATE 2. CutMATE 2 Place specimen in the cassette Simple as…1, 2 , 3… Hold specimen in the forceps Separate specimen Place specimen in the cassette.
Copyright © 2008 Delmar Learning. All rights reserved. Unit 19 Pulse and Respiration.
Copyright © 2007 by Saunders, Inc., an imprint of Elsevier Inc. Assisting in Phlebotomy Chapter 52.
Intravenous cannulation
Chapter 28 Collecting and Testing Specimens All items and derived items © 2015, 2011 by Mosby, Inc., an imprint of Elsevier Inc. All rights reserved.
Body Mechanics LEQ: How does using proper body mechanics prevent injury in the healthcare setting?
MSHA’s Guide to Equipment Guarding U.S. Department of Labor Mine Safety and Health Administration Other Training Material OT 3 Revised 2000.
© 2016 Cengage Learning ®. All Rights Reserved. May not be scanned, copied or duplicated, or posted to a publicly accessible website, in whole or in part.
L’Docile GERMANY Island Gate © 2014 Blood Glucose Monitoring System Blood Glucose Monitoring System.
Biodegradable Polymer Lancet “PINNIX Light” with Less Pain without Secondary Infection At O-Links Co., Ltd. (The manufacturer’s authorized agent)
Diabetes and Insurance.  Knowledge of available resources.  Establish open communication with an Endocrinologist.  Know how to advocate for specific.
Basics of Medical Equipment Lecture 5
SOFT TISSUE INJURIES.
Medication Dosage and Administration
Safer Sharps Our New Products
Self-injection Instructions
Pier 85: Field-ready hospital waste
Acti-Lance Safety Lancet
Department of Electrical Engineering
This figure shows a tail pulley with an inadequate guard
Body Mechanics Healthcare Professional Safety
Lab8: Fatigue Testing Machine
Lab8: Fatigue Testing Machine
13 Vital Signs and Monitoring Devices.
Non-Clinical Employees
Presentation transcript:

Lanzo Safety Lancet Copyright©2003~2011 by GMMC All Rights Reserved The integrated single-use safety lancet

CONTENTS Introduction How To Use Application Lanzo General Lancets Lanzo Lancing Device Characteristics

Designed for both healthcare professionals and patients Avoiding cross-contamination Pressure Activated Type Very ergonomic design Much less painful penetration Easy and simple to use Introduction

The non slip pattern Easy to hold and press down The used lancet cannot be reloaded! Safe Unique and distinguished design Less Painful - Never rechargeable - Needle retracts automatically Characteristics - Body for both right-hander & left hander - The non slip pattern on the cap - Eliminating vibration and wobbling - Minimized pain

Characteristics Why Lanzo Safety Lancet is less painful? 1.During the penetration, the needle moves along the four rails situated on each slide. This assists linear tracking of needle without wobbling and vibration. 2.The needle never hits the end of housing to avoid vibration when the lancet is fired. 0.5mm gap is created to prevent the needle from striking the end of the housing. Thereby preventing vibration when the lancet is fired. 3.The needle shaft is guided by a spring that keeps the needle steady when it is fired. It helps the direct motion of spring and it keeps the needle from wobbling and vibration. 0.5mm

Comparison chart of needle GMMCKorea “A”China “A”US “A”Japan “A” Shape Grinding ExcellentFairToo sharpVery excellentVery good Cleansin g Very goodFair ExcellentVery good Electro- polishing ExcellentAverage ExcellentGood Injection GoodAverageFairExcellent Retentio n Reasonable, but Sometimes, it is taken off when twisted Not protruded, not taken off ExcellentVery good Pain Less painPainfulVery painfulLess pain Q.A. Very goodAverageVery good Excellent Characteristics

Product survey including sampling test on Lanzo Safety Lancet Characteristics AgeSexRemarkUltra thin ( ㎕ ) Pain Lite ( ㎕ ) Pain Normal ( ㎕ ) Pain 47M Thick skin1Really less pain5Less pain32Less pain 47M Normal1Really less pain5Less pain35Little pain 31F Thin skin1Really less pain10Less pain35Little pain 47F Thin skin7Really less pain20Less pain35Little pain 49F Thick skin5Really less pain9Less pain22Less pain 51F Normal2Really less pain7Less pain25Little pain 51F Normal2Really less pain10Less pain20Little pain 50F Normal5Really less pain13Less pain15Little pain 32M Normal1Really less pain7Less pain35Little pain 37F Thin skin3Really less pain10Less pain35Little pain Testing place : GMMC head-office in South Korea Testing date : June 9 th 2011

How to use 1. Twist off the protective lancet cap.2. Position the lancet and press it firmly against the puncture site. 3. Gently apply intermittent pressure to the puncture site to obtain sufficient blood.

Super Normal Lite Ultra thin Application : blood glucose monitoring, HbA1c, Cholesterol Application Application : blood glucose monitoring Application : blood glucose monitoring, HbA1c, Cholesterol Application : blood glucose monitoring Application : Blood glucose monitoring system, HbA1c Cholesterol, Haemoglobin (Hgb),TG, Dignostic kit tests, other POCT tests 1 – 5 ㎕ 5 – 20 ㎕ 10 – 35 ㎕ 10 – 50 ㎕ 5 – 30 ㎕ Comfort

Working with most lancing device Reliable and comfortable lancet Ultra Smooth Tri-bevel point Lanzo General Lancet Overall Length : 26mm Point of Diameter : 3.4mm+-0.2mm 21G, 23G, 25G, 26G 28G, 30G 3 years sterile validation

SAFE Ejection of used lancet Less Painful Linear tracking reduces the pain COMFORTABLE Working with most lancets including BD lancets EFFICIENT 5 Levels of gentle skin penetration SAFE Ejection of used lancet Less Painful Linear tracking reduces the pain COMFORTABLE Working with most lancets including BD lancets EFFICIENT 5 Levels of gentle skin penetration Lanzo Lancing Device