In this experiment, C 60 was photoionized with single photons with specified energies between the energy range of 37 to 160eV. The photons used came from.

Slides:



Advertisements
Similar presentations
Applications of the Motion of Charged Particles in a Magnetic Field AP Physics C Montwood High School R. Casao.
Advertisements

General Characteristics of Gas Detectors
Production of X-rays (1)
Molecular Bonds Molecular Spectra Molecules and Solids CHAPTER 10 Molecules and Solids Johannes Diderik van der Waals (1837 – 1923) “You little molecule!”
Page 1 Wave / Particle Duality PART I Electrons as discrete Particles. –Measurement of e (oil-drop expt.) and e/m (e-beam expt.). Photons as discrete Particles.
Early Quantum Theory and Models of the Atom
2. The Particle-like Properties Of Electromagnetic Radiation
X-ray: the inverse of photoelectricity
Electromagnetic Radiation
Magnetic Fields Magnetic Field Forces on a Charged Particle Magnetic Field Lines Crossed Fields and Hall Effect Circulating Charged Particles Cyclotrons.
The Phase-Resolved Spectra of the Crab Pulsar Jianjun Jia Jan 3, 2006.
Mass Spectrometry Introduction:
Mass Spectrometry The substance being analyzed (solid or liquid) is injected into the mass spectrometer and vaporized at elevated temperature and reduced.
Atomic Mass is not a whole number
Reflectivity Measurements of Critical Materials for the LUX Dark Matter Experiment Theory My experiment was a cyclic process involving software, engineering,
What are the 3 ways heat can be transferred? Radiation: transfer by electromagnetic waves. Conduction: transfer by molecular collisions. Convection: transfer.
Classical vs Quantum Mechanics Rutherford’s model of the atom: electrons orbiting around a dense, massive positive nucleus Expected to be able to use classical.
Counting Cosmic Rays through the passage of matter By Edwin Antillon.
Forward Detectors and Measurement of Proton-Antiproton Collision Rates by Zachary Einzig, Mentor Michele Gallinaro INTRODUCTION THE DETECTORS EXPERIMENTAL.
Photoelectron Spectroscopy Lecture 7 – instrumental details –Photon sources –Experimental resolution and sensitivity –Electron kinetic energy and resolution.
Light as a Particle. Objectives  Define a quantum  Calculate the energy of a photon  Relate photon energy to wavelength and frequency of EMR.
Stopping Power The linear stopping power S for charged particles in a given absorber is simply defined as the differential energy loss for that particle.
TOF Mass Spectrometer &
Chapter 8 – Mass Spectrometry. Mass Spectrometry The mass spectrometer can be used for: – Quantitative analysis – as a sophisticated and very sensitive.
Electrons Inside The Atom Ionization and Excitation Franck-Hertz Experiment Energy Levels and Spectra Photoelectric Effect.
 How does the wavelength of a light beam and the size of a slit it is going through control the amount of diffraction? DO WORK STOP.
Fig Linear relationships of H,C,N,O and S heavy isotope contents to  values. Large natural abundance  variations from to +100o/oo correspond.
A Comparison of a Mean Field Theoretic Approach to Ferromagnetism with Experimental Results Patrick Yarbrough- Department of Physics and Engineering The.
Understanding mass spectroscopy. Mass spectroscopy is a very powerful analytical tool that can provide information on the molecular mass of a compound,
TOPIC D: SPECTROMETRY AND SPECTROSCOPY. Mass spectrometry is used to detect isotopes. mass spectrometer uses an ionizing beam of electrons to analyze.
Multiple Photoionization of C 60 K. A. Barger, R. Wehlitz, and P. Juranic.
The Origin and Nature of Light. Honors Project Deadlines Sorry about the confusion!! Project Proposal Deadline: Thursday March 1 st 2007 Project Submission.
Frank Hertz Experiment
Introduction to Plasma- Surface Interactions Lecture 3 Atomic and Molecular Processes.
Properties of cathode rays
Mechanisms of Radio Wave Emission How different mechanisms create Radio Waves that are detectable by Radio Telescopesdifferent mechanisms.
INF380 - Proteomics-51 INF380 – Proteomics Chapter 5 – Fundamentals of Mass Spectrometry Mass spectrometry (MS) is used for measuring the mass-to-charge.
1 The Quantum Mechanical Model of the Atom Chapter 7.
Starter: Spec links 1.06–1.10. Green pens out! Spec links 1.06–1.10.
28.3 THE BOHR THEORY OF HYDROGEN At the beginning of the 20th century, scientists were puzzled by the failure of classical physics to explain the characteristics.
Chapter 7 Lecture Lecture Presentation Chapter 7 The Quantum- Mechanical Model of the Atom Sherril Soman Grand Valley State University © 2014 Pearson Education,
Photoluminescence and Photocurrent in a Blue LED Ben Stroup & Timothy Gfroerer, Davidson College, Davidson, NC Yong Zhang, University of North Carolina.
Copyright © 2010 Pearson Education, Inc. Lecture Outline Chapter 2 Light and Matter.
The Nature of Light: Its Wave Nature Light is a form of made of perpendicular waves, one for the electric field and one for the magnetic field All electromagnetic.
LIGHT and MATTER Chapters 11 & 12. Originally performed by Young (1801) to demonstrate the wave-nature of light. Has now been done with electrons, neutrons,
3.1 Matter and Energy Kinetic Theory of Matter: – All matter is made of atoms – Atoms always in motion; hotter = faster, faster = hotter – Heavier particles.
1 EFFECT OF EXITING PHOTON INELASTIC SCATTERING IN PHOTOIONIZATION OF ATOMS V.A. Kilin, R.Yu. Kilin Tomsk Polytechnic University.
Calorimeter Impedance Study K. A. Barger, M. A. Lindeman, and L. E. Rocks.
Mass Spectrometry Relative atomic masses and the mass of individual isotopes can be determined using a mass spectrometer. The principle behind mass spectrometry.
Mass Spectrograph Physics Chapter 27 B. Mass spectrograph Adapted CRT/Thomson tube used to form and accelerate charged particles and measure their deflection.
Physics 213 General Physics Lecture Exam 3 Results Average = 141 points.
Instrumental Analysis
Change of State MATTER Chapter 5. Change of State A CHANGE OF STATE occurs if a material changes from one state to another because ENERGY is either GIVEN.
The Mechanisms of Electromagnetic Emissions
The Electromagnetic Spectrum
© 2017 Pearson Education, Inc.
Starter Complete the quiz and hand in..
Quantum Mechanics Reference: Concepts of Modern Physics “A. Beiser”
Mass Spectronomer.
Radiation Detectors : Detection actually means measurement of the radiation with its energy content and other related properties. The detection system.
Atomic Physics & Quantum Effects
Radiation in the Atmosphere
PHOTOELECTRIC EFFECT hhhhh 12/4/2018.
Chapter 27 Early Quantum Theory
Chapter 23 Electric Potential.
Quantum Mechanical Treatment of The Optical Properties
Interaction of Electromagnetic Radiation with Matter
Interaction of Radiation with Matter
Atomic & Nuclear Physics
Radar Detection of Lightning
Presentation transcript:

In this experiment, C 60 was photoionized with single photons with specified energies between the energy range of 37 to 160eV. The photons used came from synchrotron radiation that occurs when charged particles are accelerated in a magnetic field. The source of this radiation was the Aladdin electron storage ring at the Synchrotron Radiation Center (SRC) in Stoughton, Wisconsin. When these C 60 molecules are ionized near threshold energies, the electrons that are emitted will leave the C 60 relatively slowly compared to the ones ionized at higher energies. The threshold energy is just the minimum energy required to ionize the particle. When two or more electrons are emitted with different kinetic energies, coulomb dipole interactions may occur. As a result, the electron with the greatest momentum “sees” the positively ionized C 60 and the e - with less momentum as a dipole. These interactions can cause oscillations in the C /C cross section ratio. The ionization cross section is a measure of the probability that the particle will become ionized. In past experiments, this oscillating behavior was observed in beryllium and lithium close to threshold. However, past experiments on ionization C 60 do not show this oscillating behavior. This might be the result of large error bars and insufficient data in those experiments. In order to measure the ionization cross section of C 60, a ion time-of-flight (TOF) spectrometer was used, schematic shown in figure 1. The time-of-flight spectrometer measures the time a particle takes to travel down the drift tube. The time is proportional to the mass-to-charge ratio of the particle. This can be seen by analyzing the force acting on the system. Force is equal to mass times acceleration which is also equal to the electric field times the charge of the particle. The acceleration of the particle is given by: This means that if all the particles have the same mass, as in the case of the C 60, then the greater the charge the faster the particle. By comparing these times, the charge state can be determined. Once the travel time of the ionized C 60 is measured, the data is used to create a spectrum of the events, like the one shown in figure 2. Each channel corresponds to a different travel time down the drift tube which can be used to calculate the energy and the level of ionization of each particle. The data from spectra were then plotted as ratios of the integrated peak areas, shown in figure 4. This figure shows that the ionization ratios do not behave linearly and that they change with photon energy. To analyze this nonlinear behavior, a smooth polynomial curve was subtracted from the data. Once this was done, the oscillating behavior, which is believed to be due to coulomb dipole interactions, became apparent and is shown in figure 5. Multiple Photoionization of Carbon-60 K. A. Barger, P. Juranic, and R. Wehlitz University of Wisconsin-Madison, Synchrotron Radiation Center Figure 1: Schematic diagram of experimental setup. The C 60 in the oven are heated to ~ 310°C. At this temperature, the C 60 will sublimate and turn into a gas. The C 60 will then enter the interaction region where photons enter perpendicular to the plane of the schematic shown above. Once the C 60 becomes ionized, it is accelerated by an electric field created between PP and EP. This will cause the ions to travel down the drift tube. The drift tube and the MCP makeup the TOF spectrometer. From the C 60 travel time, the mass to charge ratio can be determined. Figure modified from R. Wehlitz, D. Lukić, C. Koncz, and I. A. Sellin, Rev. Sci. Instrum. 73, (2002). Abstract: In this experiment, C 60 clusters were ionized using synchrotron radiation. The relative photoionization cross section of the C 60 was studied using photons with specified energies range from 37 to 160eV. The 1+ to 3+ charge states were investigated as a function of energy using a time-of-flight mass spectrometer. From this information, the relative ionization cross sections can be studied for each charge state. The current theoretical models available for predicting the relative ionization cross sections are not valid for molecules or for energies that are greater then a few eV above threshold energy. The photoionization cross section for C 60 has not been closely studied until now and the data collected in this experiment can be used as benchmark data to find a model for the C 60 molecules’ relative cross sections. The results show that relative ionization cross sections do not change linearly, and oscillations in its size occur with the change in photon energy. This research is still being continued at higher energies to determine when the oscillations discontinue. Figure 3: Photograph of the experimental equipment used. This figure shows the Time-of-Flight spectrometer, the oven where the C 60 is placed, the filters used to filter out second-order light, the Condenser plate that is cooled by liquid nitrogen, and the beam line which leads to the source of the photons. Figure 4: The ratio of the ionization charge states of the C / C as a function of excess energy. The excess energy is the energy of the photons with the double-ionization threshold energy subtracted. The threshold energy used here is 19.02eV, the amount of energy required to doubly ionize C 60. Each data point corresponds to a spectrum like the one shown in figure 2. This figure shows that the behavior of the C / C ratio does not behave linearly as the photon energy increases. The non linear behavior of this graph is analyzed in figure 5. Figure by R. Wehlitz, used with permission. Figure 2: This spectrum was taken using photons at an energy of 154eV and with the oven set to a temperature of 324°C. Each peak consists of ionized C molecules as a measure of the mass-to-charge ratio. The amount of time the ions travel down the drift tube is measured by the MCP. The MCB then categorizes the measured times and creates a spectrum like the one shown above. Each one of these spectra corresponds to one data point in figure 4. Filters Condenser Plate Liquid Nitrogen Oven Time-of-Flight Spectrometer Beam Line * PP - Pusher Plate MCP - Microchannel Plate EP - Extractor Plate TAC - Time to Amplitude Converter CP - Condenser plate * - Interaction Region Figure 5: This plot shows the difference between the doubly photoionized cross section data shown in figure 4 a smooth polynomial curve. The gray fit corresponds to the Coulomb Dipole Theory. This figure shows that the doubly ionized cross section of C 60 does not behave linearly but instead oscillates. The amplitude and the wavelength of this oscillations increases with photon energy. Figure by R. Wehlitz, used with permission. Acknowledgments K. A. Barger would like to thank the NSF REU program at University of Wisconsin-Madison, and the staff of the Synchrotron Radiation Center for their support. K. A. Barger would also like to thank her mentor at the SRC Ralf Wehlitz, and Pavle Juranic as well as her advisor Jim Stewart at WWU for all their help and guidance. This work is based upon research conducted at the Synchrotron Radiation Center, University of Wisconsin-Madison, which is supported by the NSF under Award No. DMR Conclusion: The Coulomb Dipole theory predicts oscillations in the ionization cross section near threshold energies. In this experiment, these oscillations where observed in the photoionization cross section ratios of C /C 60 + not only near threshold but also at energies far above. These oscillations have been found to have an increasing wavelength and amplitude between the energies of 19 to 160eV. This research is currently being continued to 300eV to determine when these oscillations discontinue. (atomic mass units/charge)