Chem. 231 – 2/18 Lecture. Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after.

Slides:



Advertisements
Similar presentations
Chem. 231 – 3/4 Lecture. Announcements I Set 1 Lab Reports –Both Lab Reports due 3/13 –Only one of the lab reports needs to be detailed, the other can.
Advertisements

Primary Standards Is a highly purified compound that serves as a reference material in all volumetric and titrimetric methods. It must be: –1) Highly pure,
Gas Chromatography.
Instrumental Analysis
CHEM 213 Instrumental Analysis
Calibration methods Chemistry 243.
Quantification – Concepts and Integration
Chromatographic Process Provides the analyte transport. Immobile phase. Mixture of components dispersed in the mobile phase.
CHEMISTRY ANALYTICAL CHEMISTRY Fall
REAL TIME PCR ………A step forward in medicine
© 2014 Carl Lund, all rights reserved A First Course on Kinetics and Reaction Engineering Class 15.
Calibration Methods Introduction
Chem. 31 – 4/15 Lecture. Announcements I Exam 2 – Hope to have graded by next Monday Lab Reports –AA report now due Monday, 4/20 (best to try to complete.
Chem. 231 – 2/4 Lecture. Announcements I Homework Set 1 is due 2/6 New Set will be available 2/6 (hopefully) which will be due 2 weeks later Quiz 1 on.
Chem. 133 – 5/14 Lecture. Announcements I Lab Stuff Pass out Peer Review Assignments See Term Project Handout for Format of Poster Today should be check.
Chem. 31 – 4/8 Lecture. Announcements I Exam 2 – Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (up to and including retention.
Chem. 31 – 4/6 Lecture. Announcements I Exam 2 – Next Monday –Covering Ch. 6 (topics since exam 1), 7, 8-1, 17, and parts of 22 (parts in today’s lecture.
Chem. 133 – 5/5 Lecture. Announcements Lab Report 2.4 due Thursday – can turn in today for reduction of late penalties Term Project Progress Report –
Chem. 133 – 5/7 Lecture. Announcements I Exam 3 on Tuesday (will give summary of material to know later) Format will be similar to other exams I will.
Basic Questions Regarding All Analytical & Instrumental Methods (p 17-18) What accuracy and precision are required? How much sample do I have available,
Chromatographic detectors for Liquid Chromatography.
Chem. 31 – 2/18 Lecture. Announcements Turn in AP1.2 Quiz today Exam 1 coming up (1 week from next Monday) Today’s Lecture –Chapter 4 Material Calibration.
Chromatography II: HPLC
CALIBRATION METHODS.
Chem. 31 – 2/2 Lecture. Announcements Due Wednesday –Turn in corrected diagnostic quiz –HW Set 1.1 – just additional problem Quiz on Wednesday (covering.
Handling Data and Figures of Merit Data comes in different formats time Histograms Lists But…. Can contain the same information about quality What is meant.
Chem. 231 – 4/8 Lecture. Announcements Set 1 Lab Reports –hand back Set 2 Lab Reports –Due 4/10 Final Exam – April 15 th Future Mondays (after 4/15) –Set.
The following minimum specified ranges should be considered: Drug substance or a finished (drug) product 80 to 120 % of the test concentration Content.
1.1 General description - Sample dissolved in and transported by a mobile phase - Some components in sample interact more strongly with stationary phase.
Quantitative Chemical Analysis Seventh Edition Quantitative Chemical Analysis Seventh Edition Chapter 0 The Analytical Process Copyright © 2007 by W. H.
Chem. 231 – 1/28 Lecture. Introduction Goals of Course Discussion of More Practical Aspects of Separation Science Provide Specific Lab Training in Use.
Chem. 31 – 9/23 Lecture Guest Lecture Dr. Roy Dixon.
Chem. 31 – 9/21 Lecture Guest Lecture Dr. Roy Dixon.
Chem. 230 – 9/23 Lecture.
DEVELOPMENT OF A RP-HPLC METHOD FOR THE DETERMINATION OF METFORMIN IN HUMAN PLASMA.
Quality Assurance How do you know your results are correct? How confident are you?
CALIBRATION METHODS. For many analytical techniques, we need to evaluate the response of the unknown sample against the responses of a set of standards.
Data Analysis: Quantitative Statements about Instrument and Method Performance.
Data Analysis and Presentation Chapter 5- Calibration Methods and Quality Assurance EXCEL – How To Do 1- least squares and linear calibration curve/function.
HPLC – High Performance Liquid Chromatography
Validation Defination Establishing documentary evidence which provides a high degree of assurance that specification process will consistently produce.
Introduction to Chromatography. Introduction Chromatography permit the scientist to separate closely related components of complex mixtures. In all chromatographic.
Chem. 231 – 2/11 Lecture.
HPLC.
Lecture 10 ANALYTICAL METHOD DEVELOPMENT AND VALIDATION IN HPLC AND GC. Lecture 10 – Chromatography, Dr. Rasha Hanafi 1© Dr. Rasha Hanafi, GUC.
Lecture 8 Peak Parameters and Quantitative chromatography
Chem. 133 – 5/3 Lecture. Announcements Lab – Term Project Progress Report Due Today – Last Assignments: Term Project Poster and Peer Review Grading (Friday,
Instrumental Analysis (I) HPLC Tutorial 8. Graded presentation Students in groups of 4-5 individuals are asked to prepare a presentation (weight=5% of.
Chem. 31 – 6/13 Lecture. Announcements I Pipet and Buret Calibration Lab Report Due Quiz and Homework Returned in Lab Exam 1 on Thursday –Will cover material.
EQUIPMENT and METHOD VALIDATION
Art PowerPoints Harris: Quantitative Chemical Analysis, Eight Edition CHAPTER 05: QUALITY ASSURANCE AND CALIBRATION METHODS.
Chem. 133 – 5/2 Lecture.
Chem. 133 – 5/9 Lecture.
Chem. 133 – 4/27 Lecture.
Chem. 133 – 5/11 Lecture.
Internal Standard method (experiment lab-4)
Chem. 31 – 9/20 Lecture.
Automation of Solid Phase Extraction Column Chromatographic Cleanup
Automation of Sample Preparation for Trace Analysis Haibin Wan
Quantitative Gas Chromatography
Chem. 31 – 11/1 Lecture.
Chem. 31 – 10/30 Lecture.
Chem. 31 – 11/13 Lecture.
Solid Phase Extraction Optimization Experiment
HPLC.
Chem. 133 – 5/4 Lecture.
Chromatography Daheeya Alenazi.
How to quantify substances in a mixture using gas chromatography
Darrell Clinton and H. Dorota Inerowicz Purdue University
High performance liquid chromatography (HPLC)
Presentation transcript:

Chem. 231 – 2/18 Lecture

Announcements Set 2 Homework – Due Wednesday Quiz 2 – Next Monday Set 1 Labs –should be switching instruments today (or after today) –HPLC – instructions on setting up sequence for more efficient use of time Extraction Labs –SPE/HPLC lab completed (hand out) –I hope to have SPME/GC lab ready soon

HPLC – Using Sequences Demo showed how to analyze samples, one sample at a time Using autosampler to run a sequence is useful to: –run multiple samples in a defined way (e.g. calibration standards after method optimization is done) –run samples while doing other work (preparing GC lab samples or going home) –if left running unattended, must use working “Exit” program

HPLC – Using Sequences Sequences will be kept in Sequence Folder

HPLC – Using Sequences Start a new sequence

HPLC – Using Sequences Sequence Parameters and Table Need Setting

HPLC – Using Sequences Sequence Parameters gives: Data Location and names Shut down can be set here (but we have done this using an Exit program)

HPLC – Using Sequences Sequence Table gives: –auto sampler location/sample name –method –No. injections per sample –Info if using ChemStation Calibration Add Exit method on last line to shut down

Questions I On extractions, low performance LC, and integration 1.Fatty acids are being trapped using a C18 SPE column and then analyzed by HPLC with a C18 column (both under acidic conditions). The elution order observed on the column is: C12, C16:1, C14, C18:2, C16, C18:1, C18. Efficiency tests with C14 show 98% recovery. Will all other fatty acids be retained with similar recovery? If not, which will have a risk of reduced recover? 2.Furans are recovered on a diol type SPE cartridge out of transformer oil diluted in hexane. They are eluted using 50% methanol, 50% water. They are then analyzed using reversed phase HPLC. How can you use the HPLC elution order to predict poor trapping or elution efficiency on the SPE cartridge. 3.If in the SPE analysis in question 2, the chemist forgot to wash the SPE cartridge with hexane after sample application, what would be the consequence?

Questions II On extractions, low performance LC, and integration 1.Under which of the following conditions would you want to use low performance LC? a) separation of chemically similar natural products from a plant sample to obtain mg quantities b) separation of mg quantities of reaction products from chemically dissimilar reactants and side products c) analysis of ng quantities of pesticides from food samples d) separation of  g quantities of reaction products from chemically dissimilar reactants and side products 2.When is it important to set the integration criteria carefully to distinguish between noise and peaks? a) when peaks have small signal to noise ratios b) when many peaks overlap c) when peak width changes over the chromatogram

Questions III On extractions, low performance LC, and integration Looking at the chromatogram to the right, and integrated as shown a) Which peak has the largest percent integration error? b) Is the true area for this peak larger or smaller? A B

Quantitation in Chromatography Levels of Detection and Quantification Limit of Detection (LOD): –minimum detectable signal can be defined as S/N peak-to-peak = 2 to 3.3σ –minimum detectable concentration = concentration needed to get S/N peak-to-peak = 2 or S/σ = 3.3 –Calculate as 2N/m where m = slope in peak height vs. conc. calibration plot –Minimum detectable quantity = (minimum detectable conc.)(injection volume) Limit of Quantification (LOQ): –Calculated in similar fashion as LOD –Lowest concentration to give an “reasonable” conc. (e.g. can be “auto-integrated” using software) –Typically 5∙LOD

Quantitation in Chromatography LOD/LOQ example For LOD and LOQ calculations, the peak height must be used as signal (not peak area) Determine the LODs and LOQ for the following example. Determine it for the 4.6 min peak if the concentration is 0.4 ng μL -1. Use the 3.3 and 2N LOD defintions.

Quantitation in Chromatography Calibration Software for Calculations –Instrument Software (e.g. ChemStation) typical method used in industry requires setting up all work before running standards often allows checks of calibration quality before running samples –Excel we will use here for a number of reasons (only have to learn one software program, example spreadsheets often available in texts, more data processing flexibility)

Quantitation in Chromatography Calibration Calibration Methods – using Excel –External Standard – linear calibration Standards prepared Standards and Samples analyzed on same day Use Excel spreadsheet in HW Set 1, problem 3 as an example Also, see p of Miller and p of Harris (Quantitative Chemical Analysis) for examples –Non-linear Calibration With some detectors (S – FPD and ELSD) or when operating at high concentrations, non-linear calibration curves are needed Mostly can use Y = a + bx + cx 2 (2 nd order polynomial fit) or power fit (logY = b + mlogC or Y = 10 b C m ) methods Statistics to find uncertainty is much more complex

Quantitation in Chromatography Calibration Example of Power Fit –Data for maltoheptaose (7 glucoses linked together) run with HPLC-CAD –Linear fit appears not bad, but also not good –Power fit shows clear non-linear exponent

Quantitation in Chromatography Calibration Calibration Methods – using Excel –Internal Standard See p of Miller and p of Harris Text Needed for GC with manual injection Best results when external calibration plot is replaced with area ratio vs. conc. ratio –Surrogate Standard Method See p of Miller Used when no standard is available Will only work when response is predictable (e.g. NPD with known #N atoms in surrogate standard and unknown) Predictable means either same response or same response on some basis (area/#Ns per molecule in above example) Concentration A X /A S Conc. X (constant conc. S)

Quantitation One Question 1.A scientist is using GC-NPD to quantitate hydrocarbons. The NPD is expected to generate equal peak areas for equal numbers of nitrogen in a sample. Determine the concentrations of compounds X and Y based on the calibration standard (pyridine). CompoundC5H5NC5H5NX = C 6 H 6 N 2 Y = C 8 H 10 N 4 O 2 Area Conc. (ug mL -1 ) 10.0??