Two-Focus Fluorescence Correlation  Spectroscopy: A New Tool for Accurate and Absolute Diffusion Measurements Jörg Enderlein et al., ChemPhysChem, 8, 433–443.

Slides:



Advertisements
Similar presentations
Detection volume in confocal microscopy:
Advertisements

Introduction to Light Scattering A bulk analytical technique
Big Question: We can see rafts in Model Membranes (GUVs or Supported Lipid Bilayers, LM), but how to study in cells? Do rafts really exist in cells? Are.
Deconvolution of Laser Scanning Confocal Microscope Volumes: Empirical determination of the point spread function Eyal Bar-Kochba ENGN2500: Medical Imaging.
Origin of Simultaneous Donor- Acceptor Emission in Single Molecule of Peryleneimide- Terrylenediimide Labeled Polyphenylene Dendrimers Sergey M.Melnikov.
R. Hui Photonics for bio-imaging and bio- sensing Rongqing Hui Dept. Electrical Engineering & Computer Science, The University of Kansas, Lawrence Kansas.
TeraHertz Kerr effect in GaP crystal
Lecture 3 Kinetics of electronically excited states
Optical Tweezers F scatt F grad 1. Velocity autocorrelation function from the Langevin model kinetic property property of equilibrium fluctuations For.
Short pulses in optical microscopy Ivan Scheblykin, Chemical Physics, LU Outline: Introduction to traditional optical microscopy based on single photon.
Lecture 8: Measurement of Nanoscale forces II. What did we cover in the last lecture? The spring constant of an AFM cantilever is determined by its material.
Optical properties of single CdSe/ZnS colloidal QDs on a glass cover slip and gold colloid surface C. T. Yuan, W. C. Chou, Y. N. Chen, D. S. Chuu.
Nanoparticles Characterization: Measurement of the particles size by the PCS technique MSc. Priscyla D. Marcato Dr. Nelson Durán.
Single Photon Source for Quantum Communication Sarah Walters, Meng-Chun Hsu, Hubert Zal, Pierce Morgan.
Towards high performance LC lasers: Monitoring dye depletion, dye diffusion and helix distortion by transient fluorescence measurements J. Schmidtke, C.
Sub-diffraction-limit imaging by Stochastic Optical Reconstruction Microscopy (STORM) Michael J. Rust, Mark Bates, Xiaowei Zhuang Harvard University Published.
Study of Protein Association by Fluorescence-based Methods Kristin Michalski UWM RET Intern In association with Professor Vali Raicu.
4-1 Chap. 7 (Optical Instruments), Chap. 8 (Optical Atomic Spectroscopy) General design of optical instruments Sources of radiation Selection of wavelength.
DIC, fluorescence and confocal microscopy Department of Mechatronics GIST Yong-Gu Lee References: 1.“Fundamentals of light microscopy and electronic imaging,”
IPC Friedrich-Schiller-Universität Jena 1 6. Fluorescence Spectroscopy.
Lecture 7: Fluorescence: Polarization and FRET Bioc 5085 March 31, 2014.
Fukuoka Univ. A. Nishiyama, A. Matsuba, M. Misono Doppler-Free Two-Photon Absorption Spectroscopy of Naphthalene Assisted by an Optical Frequency Comb.
Quantitative Imaging Using imaging to analyze molecular events in living cells Ann Cowan.
Epi-illumination is form of Kohler Illumination:
Single Molecule Spectroscopy (SMS) 2010/6/9 Miyasaka Lab. Iida Atsushi.
Quantum Optics with single Nano-Objects. Outline: Introduction : nonlinear optics with single molecule Single Photon sources Photon antibunching in single.
Lasers and Optical Characterization Lab Ed Van Keuren, Changbao Ma, Kristen Perlot, David Littlejohn, John Menzel, Johnny Rogers, Mike Lavoie, Jonathan.
Scanning excitation and emission spectra I Wavelength (nm) )Scan excitation with emission set at 380 nm -λ ex,max = 280 nm 2) Scan emission.
Nanometric optical tweezers based on nanostructured substrates Miyasaka Lab. Hiroaki YAMAUCHI A. N. Grigorenko, N. W. Roberts, M. R. Dickinson & Y. Zhang.
FCS Club Sept 8 th 2006 Schwille, P., F. Meyer-Almes and R. Rigler (1997). "Dual-color fluorescence cross- correlation spectroscopy for multicomponent.
1/10 Tatsuya KUME Mechanical Engineering Center, High Energy Accelerator Research Organization (KEK) ATF2-IN2P3-KEK kick-off meeting (Oct. 10, 2006) Phase.
Pursuing the initial stages of crystal growth using dynamic light scattering (DLS) and fluorescence correlation spectroscopy (FCS) Takashi Sugiyama Miyasaka.
Fluorescence Correlation Spectroscopy
Cavity ring down spectroscopy 14 February 2012 CE 540.
Copyright © 2010 ISS, Inc. All Rights Reserved. Ewald Terpetschnig Ph.D. Newly designed Fluorescent Probes & Labels enabling Lifetime-Based Sensors Analytica.
Diffusion of CaM and CaMK-II Andrew Harrell Dr. Waxham Lab University of Texas Medical School.
Ch 10 Pages ; Lecture 24 – Introduction to Spectroscopy.
A way of understanding diffusion: Random Walk Spread of molecules from one spot is proportional to square root of time for random walk. Therefore, to go.
A. Nishiyama a, K. Nakashima b, A. Matsuba b, and M. Misono b a The University of Electro-Communications b Fukuoka University High Resolution Spectroscopy.
Tracking and Probing Single, Diffusing Molecules in Droplets Mark Arsenault, Peker Milas, Ben Gamari, Richard Buckman, Lori Goldner Biophysics Group MiniSymposium.
(Image: T. Wittman, Scripps) Principles & Practice of Light Microscopy 6 Special Techniques (FRET, FRAP, FLIP, FLIM, FCS, molecular sensors…)
Designing a Microscopy Experiment Kurt Thorn, PhD Director, Image from Susanne Rafelski, Marshall lab.
James A Germann, Brian K Canfield, Jason K King, Alexander Terekhov, Lloyd M Davis.
Date of download: 6/22/2016 Copyright © 2016 SPIE. All rights reserved. Prismless confocal total internal reflection (CTIR) microscope. 532-nm light is.
Date of download: 7/2/2016 Copyright © 2016 SPIE. All rights reserved. Simulation of the ablation cross section by a sequence of laser pulses with an ideal.
Saturation Roi Levy. Motivation To show the deference between linear and non linear spectroscopy To understand how saturation spectroscopy is been applied.
Static Light Scattering Part 2: Solute characteristics
Doppler-free two-photon absorption spectroscopy of vibronic excited states of naphthalene assisted by an optical frequency comb UNIV. of Electro-Communications.
Volume 84, Issue 6, Pages (June 2003)
Volume 104, Issue 4, Pages (February 2013)
Volume 84, Issue 5, Pages (May 2003)
Molecular Dynamics in Living Cells Observed by Fluorescence Correlation Spectroscopy with One- and Two-Photon Excitation  Petra Schwille, Ulrich Haupts,
Quantification of Membrane Protein Dynamics and Interactions in Plant Cells by Fluorescence Correlation Spectroscopy  Xiaojuan Li, Jingjing Xing, Zongbo.
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Förster Resonance Energy Transfer (FRET)
Jana Humpolíčková, Aleš Benda, Jörg Enderlein  Biophysical Journal 
Francesca Pennacchietti, Travis J. Gould, Samuel T. Hess 
Kinesin Moving through the Spotlight: Single-Motor Fluorescence Microscopy with Submillisecond Time Resolution  Sander Verbrugge, Lukas C. Kapitein, Erwin.
3D Protein Dynamics in the Cell Nucleus
Volume 81, Issue 3, Pages (September 2001)
Pulsed Interleaved Excitation
Samuel T. Hess, Watt W. Webb  Biophysical Journal 
Transverse coherence and polarization measurement of 131 nm coherent femtosecond pulses from a seeded FEL J. Schwenke, E. Mansten, F. Lindau, N. Cutic,
Characterization of the Photoconversion on Reaction of the Fluorescent Protein Kaede on the Single-Molecule Level  P.S. Dittrich, S.P. Schäfer, P. Schwille 
Norm Moulton LPS 15 October, 1999
Translational Diffusion of Fluorescent Proteins by Molecular Fourier Imaging Correlation Spectroscopy  Michael C. Fink, Kenneth V. Adair, Marina G. Guenza,
High-Pressure Fluorescence Correlation Spectroscopy
Single-Molecule Three-Color FRET
The Mobility of Phytochrome within Protonemal Tip Cells of the Moss Ceratodon purpureus, Monitored by Fluorescence Correlation Spectroscopy  Guido Böse,
Optical π phase shift created with a single-photon pulse
Presentation transcript:

Two-Focus Fluorescence Correlation  Spectroscopy: A New Tool for Accurate and Absolute Diffusion Measurements Jörg Enderlein et al., ChemPhysChem, 8, 433–443 (2007) Miyasaka Lab. Hiroaki YAMAUCHI

Contents Introduction ・Background Experimental Method ・Fluorescence Correlation Spectroscopy Experimental Method ・Experimental Setup ・Analysis Results and Discussion Summary

Background Translational diffusion of molecules in solution Stokes-Einstein relation D : Diffusion coefficient r : Stokes radius kB : Boltzmann’s constant T : Temperature h : viscosity of the medium Any change in Stokes radius will change the associated diffusion coefficient of the molecules. It is necessary to measure the diffusion coefficient with a high accuracy. (ex. For monitoring conformational changes in proteins)

Fluorescence Correlation Spectroscopy FCS setup sample excitation light fluorescence objective Laser beam Laser Detection volume DM Fluctuation of fluorescence PH DM : dichroic mirror PH : pinhole APD : avalanche photodiode 〈I〉 Intensity APD Time

Fluorescence Correlation Spectroscopy Fluctuation of fluorescence Autocorrelation function d I(t) d I(t+t) d I(tn) d I(tn+t) t t+t tn tn+t Intensity Time G (t) t <I> Fitting model N : average number of molecules tD : diffusion time w : wxy / wz tt : triplet lifetime p : fraction of dye molecules in triplet state wz wxy Diffusion Coefficient

Fluorescence Correlation Spectroscopy In the case that quenching occurs by molecular interaction kAB A B Fluorescent kBA Non-fluorescent

Fluorescence Correlation Spectroscopy Molecule Detection Function (MDF) Position-dependent probability to excite and detect a fluorescence photon from a molecule at a given position within the sample standard assumption three-dimensional Gaussian profile wz wxy However, the result of measurement is sensitively affected in experimental condition such as refractive index mismatch and excitation intensity

Experimental Setup objective lens Pulsed diode laser linearly polarized 640 nm wavelength 50 ps pulse duration Both lasers are pulsed alternately with an overall repetition rate of 40 MHz. (diameter 200mm) avalanche photodiode

Analysis constant Cross-correlation function 1 2 25ns constant Laser1 Laser2 G (t) t G (t) t G (t) t Each focus autocorrelation function Cross-correlation function

Analysis Cross-correlation function d Constant offset z y x g∞(d) : constant offset U(r) : molecule detection function (MDF) D : diffusion coefficient c : concentration of the molecules e1,2 : two factors describing the overall excitation power and detection efficiency   : unit vector along x d : lateral shift value x y z d Constant offset Ibg : the background intensity

Analysis MDF w(z) : width of Gaussian distribution k(z)/w2(z) : amplitude of Gaussian distribution lex : excitation wavelength lem : center emission wavelength n : refractive index of the immersion medium a : radius of the confocal aperture divided by magnification w0 , R0 : two (generally unknown) model parameters

Two-parameter model of the MDF Fluorescent intensity scan of a fluorescent bead Distance between adjacent scan planes is 0.5 mm. Each scan consisted of 200×200 pixels2 of 50×50 nm2 size. Total excitation power is below 1 mW per focus. W2(z) W1(z) effective radius W(z) k(z) Two-parameter model of the MDF fits amazingly well.

Viscosity-Dependent Diffusion NMR 2fFCS Agreement between the diffusion coefficient of NMR and 2fFCS Increasing refractive mismatch leads to increasing w0 and R0 2fFCS is insensitivity with refractive index mismatch.

Excitation Intensity Dependence photobleaching constant The diffusion coefficient of 2fFCS is constant up to 40 mW. The value of w0 increases with increasing excitation intensity. 2fFCS is insensitivity with optical saturation.

Summary The authors have proposed a new FCS setup and analytical method for accurate measurement of diffusion coefficients. They demonstrated that 2fFCS is robust against refractive index changes of the sample medium and optical saturation. The 2fFCS can be used as an ideal tool to study protein folding/unfolding dynamics thunks to its high accuracy in measurement of diffusion coefficient.