1 Aging Study for SiD Hcal and Muon System RPCs (University Linear Collider Detector R&D, project 6.19) Changgo Lu, W. Sands, K. T. McDonald, A.J.S. Smith.

Slides:



Advertisements
Similar presentations
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
Advertisements

Development of high rate RPCs Lei Xia Argonne National Laboratory.
Prototyping and study of Glass Spark Chamber detectors B.Satyanarayana TIFR, Mumbai.
1 Sep. 19, 2006Changguo Lu, Princeton University Induced signal in RPC, Configuration of the double gap RPC and Grouping of the strips Changguo Lu Princeton.
1 Dayabay RPC Detector Zhang Jiawen Outline  Motivation  RPC introduce  RPC for Daya Bay  Efficiency and noise  Module structure  Module.
Status of the LHCb RPC detector Changes with respect to Note cm strips instead of 3 cm (cost optimization) All gaps same size (standardization)
1Daya Bay RPC HV FDR 6/17/2008 RPC HV cable pick-up noise issue C. Lu, Princeton University (6/17/2008)
ARNAB BANERJEE Variable Energy Cyclotron Centre, India.
1 Humidity Effect on the RPC Changguo Lu Princeton University 10/1/2007.
1 April 7, 2009 C. Lu Monitoring the RPC Gas Mixture with a Gas Chromatograph C. Lu Princeton University.
RPC Update José Repond Argonne National Laboratory American Working Group On Linear Collider Calorimetry 16 September 2003 What’s new since Cornell…
June 6, 2001US Japan Meeting e + e - Collider Detector R&D Status Report to US Japan Committee Daniel Marlow Princeton University June 5, 2001.
Plan for MRPC Production Yongjie Sun Center of Particle Science and Technology University of Science and Technology of China.
1 March 27, 2007 IHEP RPC Bakelite Resistivity in-Situ Test Results and Strip Plane Considerations W. Sands, C. Lu and K. McDonald Princeton University.
1 August 26, 2006Changguo Lu, Princeton University Daya Bay Collaboration Meeting, IHEP, Beijing, 8/26-27, 2006 R&D for Daya Bay RPC system Changguo Lu.
1 Daya Bay collaboration meeting, IHEP, Beijing, Aug. 1-3, 2007 Test OPERA gas mixture on IHEP RPC w/ 8m long strip C. Lu Princeton University.
Daya Bay Muon Subsystem Review, 7/28-29/2007, IHEP, Beijing RPC Assembly Changguo Lu, Kirk McDonald, Bill Sands Princeton University (July 28, 2007)
ATLAS RPC: Cosmic Ray Teststand at INFN Lecce G. Chiodini, M. Bianco, E. Brambilla, G. Cataldi, R. Coluccia, P. Creti, G. Fiore, R. Gerardi, E. Gorini,
1 December 17, 2007 Visit Bakelite manufacture – Li Shen Wood Product Inc. Jiawen Zhang, IHEP Changguo Lu, Princeton University.
1 Daya Bay Collaboration Meeting, IHEP, Beijing, 8/1-3/2007 RPC aging concern Changguo Lu Princeton University Daya Bay Collaboration Meeting IHEP, Beijing,
Davide Piccolo - INFN NapoliSIENA maggio 2004 Production and Quality control of RPCs for the CMS muon barrel system Davide Piccolo – INFN Napoli.
Proposal for high sensitive measurements of 238 U and 232 Th with NAA Ezio Previtali INFN Sez. Milano Milano-Bicocca University ILIAS: JRA1 3rd General.
Results from development of Glass RPCs for INO detector
Development and study of Glass Resistive Plate Chambers Satyanarayana Bheesette Roll number: Supervisors Prof Raghava Varma, IIT Bombay Prof Naba.
1 August 18, 2005 ALCPG Workshop, Snowmass, August 14-27, 2005 Changguo Lu, Princeton University RPC experience: Belle, BaBar and BESIII Cited from “Resistive.
Status of INO detector R&D B.Satyanarayana TIFR, Mumbai.
PHENIX RPC in China Li Ye Shouyang Hu Xiaomei LI China Institute of Atomic Energy
The Progress of PHENIX RPC Production in China Shouyang HU Xiaomei LI Shouyang HU Xiaomei LI Science and Technology on Nuclear Data Laboratory China Institute.
Jiawen Zhang, IHEP, 2008, April 10, frascati Status of BEPCII/BESIII and Physics preparation Jiawen Zhang 2008/4/7—10 , PHIPSI08, Frascati.
Tariq J. Solaija, NCP Forward RPC EDR, Tariq Solaija Forward RPC EDR The Standard RPC for low  regions Tariq J. Solaija National Centre for.
On aging problem of glass Resistive Plate Chambers India-based Neutrino Observatory (INO) collaboration JIGSAW.
Muon Detector Jiawen ZHANG Introduction The Detector Choices Simulation The structure and detector design The Expected performance Schedule.
Daya Bay Muon Subsystem Review, 7/28-29/2007, IHEP, Beijing Muon System PMT Cable Routing Kirk McDonald Princeton University (July 28, 2007)
RPC Development in Beijing and Potential for NO A Tianchi Zhao University of Washington May 16, 2005.
RPC R&D status in Bucharest (JRA12-I3HP) Mihai Petrovici - CBM-Meeting, GSI, March 1,2006 Short history SMSMGRPC – Glaverbel Glass Prototype –Construction.
Optimization of the Resistive Plate Chamber operation with a closed loop gas system at the Large Hadron Collider experiments M. Capeans, I. Glushkov, R.
RPC detection rate capability ≈ 1/ρ Float-Glass ( Ω-cm) RPC rate capability < Bakelite( Ω-cm) one. New kind of doped glass was developed.
1 Test on RPC Veto Detector Model —— Anticoincidence Detector for Daya Bay Neutrino Exp. Speaker: Jiawen Zhang 5 June 2006.
Design of a readout system for RPCs Olu Amoda2 The LODEN Group The group is an association of Fermilab scientists who teamed up to build a cosmic ray.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
Status summary of RPC R&D for INO ICAL detector B.Satyanarayana, TIFR, Mumbai Satyajit Jena, IIT Bombay, Powai For INO Collaboration.
Gap Production for Upscope of the Endcap RPCs Sung Keun Park Korea Detector Laboratory Korea University February 5, 2010 Workshop on the Forward CMS RPC.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
Update on DHCAL and RPC progress Lei Xia ANL - HEP.
Results from the CMS-RPC tests at CERN Gamma Irradiation Facility Roberto Guida CMS-RPC (Bari, Beijing, Napoli, Pavia, Sofia) Seoul, October 2005.
C.Gustavino, june 4th 2004, Hamburg XPC Status report VETO status report Glass RPC R&D Outline:
Marcello Abbrescia Muon general meeting, Mon 29-Apr p. 1 R&D on improved RPCs for phase 2 upgrade M. Abbrescia on behalf of the RPC upgrade group.
Marcello Abbrescia RPCs for CMS during Phase II RPC rate capability M. Abbrescia, The dynamic behaviour of Resistive Plate Chambers, NIM A 533 (2004) 7–10.
Study of glass properties as electrod for RPC
1 Analysis of Small RPC DHCAL Prototype Data (noise and cosmic ray) LCWA09, Albuquerque, New Mexico Friday, October 02, 2009 Qingmin Zhang HEP Division,
For 2016 RPCWorkshop 1 Charge Distribution dependency on gap thickness of CMS endcap RPC Sung Park, KODEL, Korea Univ On behalf of the CMS RPC group 1.
WP 13 Task Develop a complete system of large size RPC (single- gap/multi-gap) with timing capability better than few hundreds ps. This includes.
Chamber mechanics Chamber mechanics Production in China Peking University Group – 20 Aug
DEVELOPMENT OF MULTI-GAP RESISTIVE PLATE CHAMBER(MRPC) FOR MEDICAL IMAGING Arnab Banerjee 1, Arindam Roy 1, Saikat Biswas 1,2*, Subhasis Chattopadhyay.
Performance and Aging Studies of BaBar RPC’s Henry R. Band University of Wisconsin for the BaBar IFR-RPC group RPC 2005 VIII Workshop.
Final results from an extensive aging test on bakelite Resistive Plate Chambers Stefano de Capua University of Rome II “Tor Vergata” and INFN.
1 Work report ( ) Haoqi Lu IHEP Neutrino group
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
The 6th ACFA Workshop on Physics and Detector at Linear Collider, TIFR, Mumbai, December 15-17, Development of RPCs for INO B.Satyanarayana TIFR,
XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering.
CMS – RPC GIF++ G. Pugliese on behalf of the RPC Collaboration 1.
R & D Status report on INO Naba K Mondal Tata Institute of Fundamental Research Tata Institute of Fundamental Research Mumbai, India.
Operation, performance and upgrade of the CMS Resistive Plate Chamber system at LHC Marcello Abbrescia Physics Department - University of Bari & INFN,
A proposal to equip the high eta muon stations with High Rate GRPC
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
RPC built a new plastic (peek doped with CB)
Han Jifeng BESIII MUON GROUP IHEP, CAS
BESIII RPC Detector Jiawen Zhang
STAR TOF MRPC Mass Production & Q.C. (USTC)
Presentation transcript:

1 Aging Study for SiD Hcal and Muon System RPCs (University Linear Collider Detector R&D, project 6.19) Changgo Lu, W. Sands, K. T. McDonald, A.J.S. Smith Princeton University February 15, 2010

2 Outline Review of the main motivation. Where we are standing after 6 months?  Set up a cosmic ray trigger array;  Finished second round of aging test, confirmed the aging phenomena from the first round test, on which we proposed this R&D project;  Purchased a Nikon microscope;  Microscope study of the aged RPC inner surface and Bakelite samples exposed to HF vapor; Plan for next 6 months and additional two years of the R&D.  Develop new variant Bakelite to improve the resistance to HF vapor.

3 Review: original motivation of project 6.19 Address aging issues in RPCs built from the new type of Bakelite developed by the BESIII Muon group of IHEP (Beijing) and Gaonengkedi, Inc. (Beijing) for use in the BES III and Daya Bay Muon Systems; RPCs using this material have achieved acceptable dark noise rates without Linseed oil coating, but aging effects have not been thoroughly studied - there is no published report available on this topic; A preliminary study of Daya Bay Muon System RPCs has indicated a significant aging effect that must be understood and mitigated prior to use of this technology for SiD; In the longer-term, a collaboration with IHEP and Gaonengkedi will lead to develop new variants of Bakelite that are more resistant to aging.

4 Where do we stand after 6 months of working? 16 strip scintillation counter trigger array for cosmic ray test set up and operating Assembled 5 BESIII-type aging test RPCs; Finished second round aging test for these chambers; Purchased a Nikon microscope to study surface morphology before and after the aging; Verified the aging test results from the first round of aging test — w/o oil coating BESIII-type RPC is vulnerable to HF attack; Developing new variant Bakelite electrode based on our aging test results; Preparing for third round of aging test with new RPCs made out of new-type Bakelite electrodes.

5 What we have done: Test set-up Upper trigger array (x and y, 4 for each). Bottom trigger array (x and y, 4 for each). Copper plates, Co-60 source sits on. Aging test RPCs.

6 Evolution of test RPC’s efficiency 38 (97) days are equivalent to 2.2 (5.6) years of cosmic ray run. Day 97 Day 38 Day 0 Aging dose: 1 month ~ 21 months of normal cosmic ray operation. Oiled RPC BES RPC #4 (unoiled) BES RPC #8 (unoiled)

7 Aged RPC inner surface RPC#4RPC#6 RPC#7 RPC#8 Opened the aged RPCs we can see very dense sparking marks populated all over the inner surface. RPC#8 has much smaller size sparking marks. The microscope images of the inner surface are shown in the following slides. Sparking marks Small sparking marks, display slide in larger scale will see them.

8 Microscope study: aged RPC inner surface 100 pixels scale bar equals 0.16mm in length. RPC#4 sparking spot RPC#6 sparking spotRPC#7 corroded surface RPC#8 less corroded surface

9 Future plan: Develop variant Bakelite We now know the oil coating can protect the Bakelite surface from HF attack. Based on this observed fact our Chinese collaborator is developing new techniques to integrate this coating into the Bakelite production procedure. We have obtained some small sample pieces. The surface smoothness is not as good as ordinary Bakelite, it certainly needs further improvement. We are also developing mirror quality surface Bakelite sheet. The existing production facility in Hebei China can produce such Bakelite, but more expensive. The goal of this R&D is lower the cost, make it affordable. Another by-product from this R&D is thin Bakelite sheet. We have produced 0.33mm thick Bakelite sheet, which has good potential application for making double gap RPC and mRPC. 2mm Bakelite 0.45mm Bakelite Thin Bakelite sheet

10 Future plan: 3-d round of aging test 5 new RPCs that made out of new variant Bakelite have been assembled, their initial performance has been checked. The new Bakelite used different resin, which mixes Linseed oil into normal resin. Preliminary test shows its resistance to HF is somewhat better than original BESIII Bakelite. Aging test on these RPCs will tell us if this technique works. At the same time our Chinese collaborators will develop more variant Bakelite. It could be a long learning process, through try and error we’ll find our best solution.