UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA DALE E. HOUCK MECHANICAL OPTION.

Slides:



Advertisements
Similar presentations
DOUG BOSWELL MECHANICAL OPTION APRIL 16, 2008 Temple University Tyler School of Art.
Advertisements

Kevin Edstrom Mechanical Option 2011 Senior Thesis April 12 th, 2011 Georgetown University New Science Center Washington, DC.
Introduction Enthalpy Wheel
Chilled Beam Presentation
The Hearst Tower 959 Eighth Avenue New York, NY
STEM Center Delaware County Community College – Media, PA Thesis Final Presentation Dan Saxton Mechanical Option.
Sustainable solutions in engineering Introduction of Building Industry in BC Presented by: Philip Fung, M.Sc., P.Eng., LEED AP Tony Tang, P.Eng., LEED.
Energy in Focus Energy Savings with Water Based Systems By Maija Virta Specialist of Indoor Environment Technology.
Sustainable Design & Construction at Yale University July 2009.
Active beams versus VAV with Reheat Analysis of May 2013 ASHRAE Journal article Ken Loudermilk Vice President, Technology & Developement.
Jacksonville, FL The Pennsylvania State University Department of Architectural Engineering Zachary Polovchik Mechanical Option Advisor – Dustin Eplee Duval.
WESTINGHOUSE ELECTRIC NUCLEAR ENGINEERING HEADQUARTERS DANIEL AUGHENBAUGH - MECHANICAL OPTION Westinghouse Nuclear Engineering Headquarters Daniel Aughenbaugh.
Houston Independent School District James A. Berry Elementary School PROJECT PROFILE PROJECT HIGHLIGHTS Berry Elementary is an environmental sciences magnet.
Coppin State University Physical Education Complex Kaylee Damico – Mechanical Option April 12 th, 2011 Presentation Outline Project Team Project Overview.
Integration of Mechanical System Redesign Geothermal Heat Pump Redesign Wesley S. Lawson Architectural Engineering Mechanical Option Pennsylvania State.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Bowie State University Fine and Performing Arts Center Zachary Lippert Faculty Advisor: Dr. Stephen Treado.
The Edward St. John Student Center Zachary Haupt Faculty Advisor: Dr. William Bahnfleth 11 April 2011.
BEM CLASS 5 Building Thermodynamics – 2 Air-conditioning Load Calculation – latent heat, solar and internal gains.
Saavedra Gehlhausen Architects Title: text size 36 pt. Text size 28 pt. Karl J. Jacobs Center for Science and Math.
LEED New Construction & Major Renovations Rating System
DEA Clandestine Laboratory Training Center Penn State University Architectural Engineering Mechanical Option David M. Potchak.
Technology and Engineering Development (TED) Building Thomas Jefferson National Accelerator Facility Newport News, VA David Blum | Mechanical Option Dustin.
CENTRAL HIGH SCHOOL Central High School MID-ATLANTIC REGION ADAM BROWN MECHANICAL OPTION SPRING 2014 Introduction Existing Mechanical System Thesis Proposal.
Presentation Outline Introduction System Optimization Analysis Acoustical Breadth Conclusion Acknowledgements Questions Thesis Final Presentation Army.
Foothill College & Space Science Center Bill Kelly Viron Energy Services (510) ext 13,
The New RLPS Architects Office Building Lancaster, PA Brice Ohl – Mechanical Option Presented on 4/10/13.
SENIOR THESIS PRESENTATION
Best Practices in Overall Sustainable Design Cal State University, Long Beach - Liberal Arts 2, 3 and 4 Renovation Presented By:Mark Zakhour,, CASp, LEED.
Solar Panels are Solar power is the conversion of sunlight into electricity.
Brian Ault – Mechanical OptionSpring 2008 Senior ThesisBarshinger Life Science & Philosophy Ann & Richard Barshinger Life Science & Philosophy Building.
Architectural Engineering Mechanical Option Ft. Detrick Defense Medical Logistics Center Building Systems Redesign April 16, 2008 Senior Thesis Presentation.
Green Modifications Suburban Wellness Center Germantown, Maryland Cory J. Abramowicz.
Ray & Joan Kroc Corps Community Center Mathias Kehoe | Mechanical Option April 09, 2012.
NRUCFC Headquarters Building Sterling, VA Architectural Engineering Senior Thesis Margaret McNamara | Mechanical Option Advisor | Dr. Stephen Treado.
University Ridge at E ast Stroudsburg University Matthew Carr Spring 2007 Mechanical Option Faculty Advisor: Dr. Freihaut.
Paul Roberts Senior Thesis 2010 Construction Management.
The Health Care Center Dauphin County, PA Ken Lorenz Penn State University Architectural Engineering Construction Management April 17, 2007.
Bronx School for Law Government & Justice Yulien Wong Mechanical Option 2006 Senior Thesis Bronx, New York.
Tri-Valley Jr./Sr. High School Hegins, PA Senior Thesis, Spring 2004 Studying The Feasibility of a Dedicated Outdoor Air System.
Whitman-Hanson Regional High School Energy Efficient Systems: HVAC All fans and pumps are VFD controlled with fully reactive controls Condensing gas-fired.
Spring 2007 Senior Thesis Justin D. Schultz Mechanical Option The Hauptman-Woodward Medical Research Institute Dedicated Outdoor Air Applications at the.
The American Recovery and Reinvestment Act: A NIH Overview.
APPELL LIFE SCIENCES York College of Pennsylvania Joshua Martz | Dr. Srebric | April 11, 2011 Image Courtesy of RLPS, Ltd.
University of Maryland’s Gossett Field House College Park, MD Jason Borowski Architectural Engineering Mechanical Option Pennsylvania State University.
Greenbriar East Elementary School Fairfax, Virginia Michelle L. Siano Mechanical Option Spring 2005 Senior Thesis.
Straumann USA 60 Minuteman Road Andover, MA Kevin Kaufman Mechanical Option The Pennsylvania State University Architectural Engineering.
Building Systems Integration - Energy and Cost Analysis The Milton Hershey School New Supply Center Justin Bem AE Senior Thesis – Spring 2007 Mechanical.
Malory J. Faust ∙ Mechanical Option ∙ Senior Thesis 2007.
Twin Rivers Elementary/Intermediate of McKeesport Area School District Tessa Bauman Mechanical Option Technical Consultant: Laura Miller 1600 Cornell St.,
Britt Kern Mechanical Option Advisor: Dr. Treado Hunter’s Point South School Queens, New York.
Jesse A. Fisher Mechanical Option Spring 2005 Riverpark Corporate Center, Phase 1 Salt Lake City, Utah.
Hamot Women’s Hospital Erie, PA Michael Galleher Mechanical Option l AE-Senior Thesis l April 12, 2011 l Advisor Dr. Jelena Srebric.
The New Student Housing Building at The Mount St. Mary’s University Emmitsburg, Maryland Erik Shearer Mechanical Option Advisor: Dr. Srebric Spring 2007.
J. david maino the pennsylvania state university architectural engineering lighting/electrical.
The importance of process in high performance building design.
NOLAN JAMES AMOS Dr. William Bahnfleth, Faculty Consultant architectural engineering senior thesis mechanical option PHOENIXVILLE EARLY LEARNING CENTER.
Manoa Elementary School Amanda Cronauer Faculty Advisor: Dr. William Bahnfleth 14 April 2010.
Michael Reilly, Jr. – Mechanical Option Advisor – James Freihaut, PhD & Dustin Eplee The Pennsylvania State University Nassau Community College Life Sciences.
Derek Sitosky Lighting/Electrical von Liebig Center for Science.
Objectives of a Green Building
ENVIROCENTER PHASE II JESSUP, MD
David Anderson Mechanical Option
Grunenwald Science and Technology Building
Acterna Headquarters John M Sekel, EIT Germantown, Maryland
Biobehavioral Health Building, University Park, PA
LONGWOOD AT OAKMONT HEALTHCARE CENTER
The Ed Roberts Campus Berkeley, CA Introduction Existing Systems
INNOVATION lab MEP MECHANICAL/ELECTRICAL/PLUMBING :
Professor of Architectural Engineering College of Engineering
Presentation transcript:

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA DALE E. HOUCK MECHANICAL OPTION

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA DALE E. HOUCK MECHANICAL OPTION PROJECT SUMMARY EXISTING CONDITIONS DEPTH STUDIES SUSTAINABILITY BREADTH STUDIES CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA INTRODUCTION PROJECT SUMMARY INTRODUCTION PROJECT SUMMARY EXISTING CONDITIONS DEPTH WORK BREADTH WORK CONCLUSIONS OWNER ARCHITECTS AND ENGINEERS CONSTRUCTION MANAGER SITE/CIVIL ENGINEER LANDSCAPE ARCHITECT THE UNIVERSITY OF SCRANTON EINHORN YAFFEE PRESCOTT A&E, P.C. QUANDEL ENTERPRISES, INC. CECO ASSOC, INC. M.L. BAIRD & CO. PROGRAM 150,000 SF NEW CONSTRUCTION 50,000 SF RENOVATIONS 4 FULL FLOORS, PARTIAL GROUND FLOOR CONSTRUCTION: MAY 2009 – FALL 2011 $73 MILLION GMP CONTRACT DEPARTMENTS OF BIOLOGY, CHEMISTRY, COMPUTING SCIENCES, PHYSICS, ELECTRICAL ENGINEERING, AND MATHEMATICS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA INTRODUCTION PROJECT SUMMARY Architecture Designed according to principles of project kaleidoscope Encourages interdisciplinary collaboration Modern design of new construction seamlessly integrates with renovation of existing structure INTRODUCTION PROJECT SUMMARY EXISTING CONDITIONS DEPTH WORK BREADTH WORK CONCLUSIONS DESIGNED FOR LEED SILVER CERTIFICATION STONE FAÇADE SUPPLIED BY LOCAL QUARRY RECYCLED MATERIALS CONSTRUCTION WASTE MANAGEMENT EFFICIENT LIGHTING AND MECHANICAL SYSTEMS EFFICIENT WATER FIXTURES

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA EXISTING CONDITIONS AIR SIDE INTRODUCTION EXISTING CONDITIONS AIRSIDE WATERSIDE DEPTH WORK BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA EXISTING CONDITIONS AIR HANDLING UNITS VARIABLE AIR VOLUME SUPPLY FANS ENTHALPY WHEELS VARIABLE FREQUENCY DRIVE FANS AIR SIDE INTRODUCTION EXISTING CONDITIONS AIRSIDE WATERSIDE DEPTH WORK BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA EXISTING CONDITIONS WATER SIDE INTRODUCTION EXISTING CONDITIONS AIRSIDE WATERSIDE DEPTH WORK BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA EXISTING CONDITIONS WATER SIDE INTRODUCTION EXISTING CONDITIONS AIRSIDE WATERSIDE DEPTH WORK BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH HEAT RECOVERY WHEEL INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS EXISTING ENTHALPY WHEEL TRANSFERS LATENT AND SENSIBLE HEAT BETWEEN EXHAUST AND SUPPLY AIR

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH HEAT RECOVERY WHEEL INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS EXISTING ENTHALPY WHEEL TRANSFERS LATENT AND SENSIBLE HEAT BETWEEN EXHAUST AND SUPPLY AIR ADDITION OF SENSIBLE WHEEL ELIMINATES NEED FOR HEATING COIL

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH HEAT RECOVERY WHEEL INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH HEAT RECOVERY WHEEL INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS FIRST COST: + $400,000 ENERGY SAVINGS: $45,000/YEAR SIMPLE PAYBACK PERIOD: 8-9 YEARS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH CHILLED BEAMS INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH CHILLED BEAMS INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS FIRST COST: +207,200 ENERGY SAVINGS: $75,000/YEAR SIMPLE PAYBACK PERIOD: 3-5 YEARS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH TRADITIONAL VAV SYSTEM INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS POOR ENERGY USE POOR USE OF PLENUM SPACE UNKNOWN VENTILATION PERFORMANCE

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH TRADITIONAL VAV SYSTEM INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT DEPTH TRADITIONAL VAV SYSTEM INTRODUCTION EXISTING CONDITIONS DEPTH WORK SENSIBLE WHEEL CHILLED BEAMS VAV SYSTEM BREADTH WORK CONCLUSIONS FIRST COST: COMPARABLE TO EXISTING SYSTEM ENERGY COST INCREASE: $200,000/YEAR POOR INDOOR AIR QUALITY INCREASED MECHANICAL SPACE

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH LIGHT SHELVES INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH LIGHT SHELVES INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH LIGHT SHELVES INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH SOLAR PANELS INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH SOLAR PANELS INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH SOLAR PANELS INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS 900 SF 10 KW SOLAR ARRAY: INITIAL COST: $90,000 ENERGY SAVINGS: $1,066/YEAR SIMPLE PAYBACK PERIOD: 90 YEARS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA PROJECT BREADTH RAINWATER COLLECTION INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK LIGHT SHELVES SOLAR PANELS RAINWATER REUSE CONCLUSIONS 11,000 SF ROOF AREA FIRST COST: $437,500 UTILITY SAVINGS: $2,750/YEAR SIMPLE PAYBACK PERIOD: 160 YEARS

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA CONCLUSIONS INTRODUCTION EXISTING CONDITIONS DEPTH WORK BREADTH WORK CONCLUSIONS HEAT RECOVERY WHEELS GOOD OPTION CHILLED BEAMS UNCERTAINTY OF LATENT LOADS VAV SYSTEM OUTPERFORMED IN INITIAL AND ANNUAL COST LIGHT SHELVES SUBJECT TO PLENUM SPACE SOLAR PANELS NOT ECONOMICALLY VIABLE RAINWATER COLLECTION NOT ECONOMICALLY VIABLE

UNIFIED SCIENCE CENTER THE UNIVERSITY OF SCRANTON SCRANTON, PA QUESTIONS?