RFX-mod Programme Workshop 2009 – 20-22 January 2009 RFX-mod Diagnostic Status and Plans S.Martini on behalf of the RFX Team.

Slides:



Advertisements
Similar presentations
Ion Heating and Velocity Fluctuation Measurements in MST Sanjay Gangadhara, Darren Craig, David Ennis, Gennady Fiskel and the MST team University of Wisconsin-Madison.
Advertisements

Anomalous Ion Heating Status and Research Plan
Examples of ITER CODAC requirements for diagnostics
An Image Filtering Technique for SPIDER Visible Tomography N. Fonnesu M. Agostini, M. Brombin, R.Pasqualotto, G.Serianni 3rd PhD Event- York- 24th-26th.
Development of experimental devices to study first wall conditioning and transport phenomena in RFX-mod experiment Stefano Munaretto Università degli studi.
APS-DPP-2005-LeBlanc-1 Update on MPTS B.P. LeBlanc Princeton Plasma Physics Laboratory NSTX Results Review July 26-27, 2006 Princeton, NJ.
Soft x-ray tomography on HT-7 tokamak K.Y. Chen, L.Q. Hu, Y.M. Duan HT-7.
427 PHC.  Atomic emission spectroscopy (AES) is based upon emission of electromagnetic radiation by atoms.
Analysis of instrumental effects in HIBP equilibrium potential profile measurements on the MST-RFP Xiaolin Zhang Plasma Dynamics Lab, Rensselaer Polytechnic.
PERFORMANCE OF THE DELPHI REFRACTOMETER IN MONITORING THE RICH RADIATORS A. Filippas 1, E. Fokitis 1, S. Maltezos 1, K. Patrinos 1, and M. Davenport 2.
Physics of fusion power
13th IEA/RFP Workshop – Stockholm October 9-11, D characterization of thermal core topology changes in controlled RFX-mod QSH states A. Alfier on.
Plasma Dynamics Lab HIBP Abstract Measurements of the radial equilibrium potential profiles have been successfully obtained with a Heavy Ion Beam Probe.
A. Canton, S. Dal Bello 13 th IEA/RFP Workshop Density control in RFX-mod A. Canton, S. Dal Bello Consorzio RFX, Padova, Italy.
Physics of fusion power Lecture 8 : The tokamak continued.
HEAT TRANSPORT andCONFINEMENTin EXTRAP T2R L. Frassinetti, P.R. Brunsell, M. Cecconello, S. Menmuir and J.R. Drake.
Outline (HIBP) diagnostics in the MST-RFP Relationship of equilibrium potential measurements with plasma parameters Simulation with a finite-sized beam.
Imaging Diagnostics at the H-1 National Plasma Fusion Research Facility Left: The coherence tomography system Above: Plasma emission reconstructions compared.
49th Annual Meeting of the Division of Plasma Physics, November , 2007, Orlando, Florida Ion Temperature Measurements and Impurity Radiation in.
Prog WKS 2011 RFX-mod Diagnostic systems for 2011 campaign presented by S. Martini.
Atomic Emission Spectroscopy
D. Borba 1 21 st IAEA Fusion Energy Conference, Chengdu China 21 st October 2006 Excitation of Alfvén eigenmodes with sub-Alfvénic neutral beam ions in.
Measurements with the KSTAR Beam Emission Spectroscopy diagnostic system Máté Lampert Wigner Research Centre for Physics Hungarian Academy of Sciences.
Fast imaging of global eigenmodes in the H-1 heliac ABSTRACT We report a study of coherent plasma instabilities in the H-1 plasma using a synchronous gated.
RFX-mod Workshop – Padova, January Experimental QSH confinement and transport Fulvio Auriemma on behalf of RFX-mod team Consorzio RFX, Euratom-ENEA.
2D Position Sensitive Detector for Plasma diagnosis
Edge Neutral Density (ENDD) Diagnostic Overview Patrick Ross Monday Physics Meeting Monday, March19, 2007.
The PEPPo e - & e + polarization measurements E. Fanchini On behalf of the PEPPo collaboration POSIPOL 2012 Zeuthen 4-6 September E. Fanchini -Posipol.
Profile Measurement of HSX Plasma Using Thomson Scattering K. Zhai, F.S.B. Anderson, J. Canik, K. Likin, K. J. Willis, D.T. Anderson, HSX Plasma Laboratory,
XP NSTX Results Review Beam Modulation Effects on Ion Power Balance XP 737 P.W.Ross.
NEW COMMENTS TO ILC BEAM ENERGY MEASUREMENTS BASED ON SYNCHROTRON RADIATION FROM MAGNETIC SPECTROMETER E.Syresin, B. Zalikhanov-DLNP, JINR R. Makarov-MSU.
Correlation Analysis of Electrostatic Fluctuation between Central and End Cells in GAMMA 10 Y. Miyata, M. Yoshikawa, F. Yaguchi, M. Ichimura, T. Murakami.
The principle of SAMI and some results in MAST 1. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui, , China 2. Culham Centre.
PROTO-SPHERA Diagnostics PROTO-SPHERA WORKSHOP Frascati March 18-19, 2002.
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
RFX-mod Programme Workshop 2009 – January 2009 Scaling and validation plans Paolo Franz, Monica Spolaore.
Introduction to Plasma- Surface Interactions Lecture 3 Atomic and Molecular Processes.
Experimental set-up for on the bench tests Abstract Modeling of processes in the MCP PMT Timing and Cross-Talk Properties of BURLE/Photonis Multi-Channel.
14 Oct. 2009, S. Masuzaki 1/18 Edge Heat Transport in the Helical Divertor Configuration in LHD S. Masuzaki, M. Kobayashi, T. Murase, T. Morisaki, N. Ohyabu,
Pellet Charge Exchange Measurement in LHD & ITER ITPA Tohoku Univ. Tetsuo Ozaki, P.Goncharov, E.Veschev 1), N.Tamura, K.Sato, D.Kalinina and.
Brent Stratton for the NCSX Team Princeton Plasma Physics Laboratory Oak Ridge National Laboratory NCSX Program Advisory Committee Meeting #8 Princeton.
Study of NSTX Electron Density and Magnetic Field Fluctuation using the FIReTIP System K.C. Lee, C.W. Domier, M. Johnson, N.C. Luhmann, Jr. University.
Gregory ClarkeTechnological Plasmas Research Group Time resolved diagnostics for pulsed magnetron plasmas.
Updates On THE Optical Emission Spectroscopy AND Thomson Scattering Investigations on the Helicon Plasma Experiment (HPX)* *Supported by U.S. DEPS Grant.
HT-7 ASIPP The Influence of Neutral Particles on Edge Turbulence and Confinement in the HT-7 Tokamak Mei Song, B. N. Wan, G. S. Xu, B. L. Ling, C. F. Li.
Objectives Much better spatial resolution Velocity space discrimination W. Heidbrink, M. Van Zeeland, J. Yu FIDA Imaging Proposal.
RFX-mod programme workshop, January 2009 Scenario and operational issues for high current L. Zanotto, R. Cavazzana, S. Dal Bello, F. Milani.
RF source, volume and caesiated extraction simulations (e-dump)
Comparison between X-ray measurements with the GEM detector and EFIT calculations Danilo Pacella Present address: JHU, Baltimore, MD Permanent address:
T. Bolzonella – 9 February 2011 – RFX-mod programme workshop TF1: Physics integration for high performance RFP Proposals and discussion T. Bolzonella,
Solenoid Free Plasma Start-up Mid-Run Summary (FY 2008) R. Raman and D. Mueller Univ. of Wash. / PPPL 16 April 2008, PPPL 1 Supported by Office of Science.
Edge Turbulence in High Density Ohmic Plasmas on NSTX K.M. Williams, S.J. Zweben, J. Boedo, R. Maingi, C.E. Bush NSTX XP Presentation Draft 5/25/06.
1 Progress of the Thomson Scattering Experiment on HSX K. Zhai, F.S.B. Anderson, D.T. Anderson HSX Plasma Laboratory, UW-Madison Bill Mason PSL, UW-Madison,
47th Annual Meeting of the Division of Plasma Physics, October 24-28, 2005, Denver, Colorado ECE spectrum of HSX plasma at 0.5 T K.M.Likin, H.J.Lu, D.T.Anderson,
1 NSTX EXPERIMENTAL PROPOSAL - OP-XP-712 Title: HHFW Power Balance Optimization at High B Field J. Hosea, R. Bell, S. Bernabei, L. Delgado-Aparicio, S.
Scaling experiments of perturbative impurity transport in NSTX D. Stutman, M. Finkenthal Johns Hopkins University J. Menard, E. Synakowski, B. Leblanc,R.
APS, 44th Annual Meeting of the Division of Plasma Physics November 11-15, 2002; Orlando, Florida Hard X-ray Diagnostics in the HSX A. E. Abdou, A. F.
Initial Results from the Scintillator Fast Lost Ion Probe D. Darrow NSTX Physics Meeting February 28, 2005.
Simulation of Turbulence in FTU M. Romanelli, M De Benedetti, A Thyagaraja* *UKAEA, Culham Sciance Centre, UK Associazione.
Upgrade of the HSX Thomson Scattering System HSX TS upgrade requirement K. Zhai, F. S. B. Anderson, D. T. Anderson, C. Clark, HSX Plasma Laboratory, Univ.
Neutral beam ion loss measurement and modeling for NSTX D. S. Darrow Princeton Plasma Physics Laboratory American Physical Society, Division of Plasma.
52nd Annual Meeting of the Division of Plasma Physics, November 8 – November 12, 2010, Chicago, IL Development of Laser Blow-Off Impurity Injection Experiments.
Fast 2-D Tangential Imaging of Edge Turbulence: Neon Mantle (draft XP) R. J. Maqueda, S. J. Zweben, J. Strachan C. Bush, D. Stutman, V. Soukhanovskii Goal:
= 2·10 18 m -3 T e (0) = 0.4 keV ECH and ECE on HSX Stellarator K.M.Likin, A.F.Almagri, D.T.Anderson, F.S.B.Anderson, C.Deng 1, C.W.Domier 2, R.W.Harvey.
Zhouqian, Wan baonian and spectroscopy team
Experiments at LCLS wavelength: 0.62 nm (2 keV)
Status of Equatorial CXRS System Development
First Experiments Testing the Working Hypothesis in HSX:
Review of spectroscopic diagnostic at COMPASS tokamak
Visible Doppler Spectrometer for Edge Toroidal Rotation
Presentation transcript:

RFX-mod Programme Workshop 2009 – January 2009 RFX-mod Diagnostic Status and Plans S.Martini on behalf of the RFX Team

RFX-mod Programme Workshop 2009 – January 2009 IntroductionIntroduction 2008 “new entries”2008 “new entries” 2009 plans2009 plans ConclusionsConclusions

RFX-mod Programme Workshop 2009 – January 2009 RFX Achievements 2008 FIR polarimeter operational and providing data New measurements: edge T e and n e from He lines intensity ratio, impurity injection by laser Blow-off, q-profile from H pellets ablation cloud desorption diagnostic edge Thomson scattering

RFX-mod Programme Workshop 2009 – January 2009 Scope Reconstuction of B Θ profile by measurements of faraday angle. Details channels FIR radiation at μm Measurements range between 5° and 10° Time resolution 1÷3 ms Measure Faraday angles with error < 10% Future plans Installation completed during spring 2008 Measure of the magnetic axis position B Θ profile computed by Abel inversion Equilibrium computed using polarimetric measurements as constraints First polarimeter measurement in RFX-mod F. Auriemma, M. Brombin, A. Canton, E. Zilli

RFX-mod Programme Workshop 2009 – January 2009 FIR polarimeter chord layout 6 vertical chords (5 active) chord name h [m] ch ch ch ch ch ch FIR radiation: =118.8  m ch2ch3ch4ch5ch6ch1

RFX-mod Programme Workshop 2009 – January 2009 Sample polarimeter measurements high current & density #25570 MODEL:  &p n e $ [1-(r/a) 15 ] measurements

RFX-mod Programme Workshop 2009 – January 2009 Polarimeter summary first faraday rotation measurements on 5 calibrated chords in high current RFX-mod discharges...to do: residual oscillations at the end of the pulse automatic calibration procedure enhancing and stabilizing FIR laser output power 1 broken beam splitting grid new beam splitting system with quartz platesbetter beams alignment installation chord #1

RFX-mod Programme Workshop 2009 – January 2009 Thermal Helium Beam (THB) A He atomic beam injected into plasma and 3 of its emission lines (at 667.8, and nm ) observed. Light collected from 8 different radial positions, 0 to 35 mm with a spatial resolution of 5 mm. A spectrograph is used as polychromator. The lines can be observed by: a CCD with a time resolution of ~100 µs, 3 multianode PMTs for a resolution up to 10 µs.

RFX-mod Programme Workshop 2009 – January 2009 Thermal Helium Beam (THB) An example of results obtained using THB with CCD cameras: time evolution of edge radial profiles of T e, n e and P e. At the end of 2008 PMTs have been installed. After calibration and tests, first plasma signals have been collected.

RFX-mod Programme Workshop 2009 – January 2009 Laser Blow-Off (LBO) Same laser used for edge Thomson scattering and LBO, with a beam splitter allowing the simultaneous activation. First injections carried out ablating a Ni target, a well- suited impurity for transport studies in RFX-mod plasma. Different target thickness and optic configurations tested to optimize the Ni ablation.

RFX-mod Programme Workshop 2009 – January 2009 Sample: LBO inside QSH Island Shot #24073 at 1.2 MA. Top: line integrated SXR brightness. Centre: T e by double filter diagnostic. Bottom: dominant mode m=1,n=-7 and secondary mode m=1,n=-11 -> Ni entered inside hot structure. LBO provide Ni source inside QSH island, allowing the study of impurity transport. Lines Ni XVII and Ni XVIII (249 & 292 Å) observed, together with SXR emissivity increase

RFX-mod Programme Workshop 2009 – January 2009 q profile from pellet ablation cloud Using new fast CMOS camera, first safety factor profile, q(r), measurements in RFX- mod by observing ablation cloud of H pellets. Cloud angle has been measured

RFX-mod Programme Workshop 2009 – January 2009 q profile from pellet ablation cloud First measurements prove the possibility to measure q(r). Spatial resolution and accuracy to improve with Li pellet injector thanks to lower pellet speed and more elongated cloud. profiles agree with toroidal equilibrium model

RFX-mod Programme Workshop 2009 – January 2009 DESOrption diagnostic To seek better density control during operation, new diagnostic, DESO, implemented A series of dummy openings before each RFX-mod shot improves piezo valves flow reproducibility. By processing time evolution of in-vessel pressure, DESO computes both total number of particles supplied by the valve system and total number of particles outgassed from wall and extracted by pumping system.

RFX-mod Programme Workshop 2009 – January 2009 DESOrption diagnostic DESO measurements, coupled to other diagnostics data (masses of injected pellets, mass spectrometer measurements of particles removed from wall during He GDC’s), allows to compute 3 parameters :  Des% Desorption Factor -> ratio between particles extracted after pulse end and total ones fuelled.  DeltaPart Number of particles left in the wall after each shot -> difference between total fuelled particles and outgassed ones (in case of He GDC extracted particles are subtracted),  TotPart -> total number of particles stored in the wall since last baking or boronization procedure, computed as sum of DeltaPart for all shots since last wall conditioning.

RFX-mod Programme Workshop 2009 – January 2009 DESOrption diagnostic Des% describes wall capability to absorb particles in each shot. Correlates to I/N values more than TotPart: a non-absorbing wall (Des%>100%) forces I/N to 2  Am, corresponding to maximum sustainable n e. Conversely, DeltaPart behavior shows that more particles are stored in the wall at each shot, i.e. an effective way to prevent wall particle accumulation has not yet been found.

RFX-mod Programme Workshop 2009 – January 2009 Edge Thomson Scattering Single pulse ruby laser 694nm, 30ns at FWHM) focused on a 3mm pin-hole in vacuum. Sapphire lens & prism deflect beam by 30° and image the pin-hole in vacuum vessel. A camera lens (f=83mm / F#1.2) collects light at ~150° from 16 positions over  =1mm fibers: 12 scattering volumes for Te, ∼ 10mm resolution; 4 measuring points for detecting background plasma light. The entrance port hosts the input system & the collection window  stable alignment. Fibers are arranged in a 4x4 pattern and fed into a 4 spectral channels spectrometer. An Intensified CCD (ICCD) acquires the Thomson and the Background signal

RFX-mod Programme Workshop 2009 – January 2009 Edge Thomson Scattering Example of measure Red: edge Ts Blue : closest main Ts profile #25119,n 8E19 Done: acquisition has shifted from CCD camera to fast APD Status: able to measure for n> 3 x Fiber coupling and optics rearrange should shift limit to 1 x To reach lower limits a mechanical modification needed (to overcome vignetting of external channels)

RFX-mod Programme Workshop 2009 – January plans Acquiring new diagnostics in order to : Improve fundamental data set (NPA) Supplement operation of NBI on loan from TPE-RX (FILD). Enhance analysis capability at high current (Li NB diagnostic) Completion / development 2008 activities

RFX-mod Programme Workshop 2009 – January 2009 A Neutral Particle Analyser (NPA), based on re-ionization and magnetic deflection has been borrowed from the Max Planck Institute in Greifswald 22 channels analyse the ion (H,D) distribution function in the keV energy range. T i measurement from NPA

RFX-mod Programme Workshop 2009 – January 2009 T i measurement from NPA the 11 (H) channels of NPA system will be used to measure T i and detect fast ion tails. Fast data acquisition will allow 50  s count windows. Data will be analyzed using Monte Carlo codes simulating neutrals production inside the plasma: utilize modified Nené code, originally developed to reconstruct particle source term in transport simulations.

RFX-mod Programme Workshop 2009 – January 2009 Fast Ion Losses Diagnostic (FILD) To supplement high power NBI injector on loan from TPE-RX, a fast-ion diagnostic will study losses due to instabilities dedicated to a feasibility study to identify the best solution between:  Magnetic collimator spectrometer  Faraday cup collector

RFX-mod Programme Workshop 2009 – January 2009 FILD Top and side view of collimator. Gyroradius (energy) of the particle determines how far from the aperture it strikes the scintillator (left). Pitch angle determines where it strikes along the orthogonal dimension (right).

RFX-mod Programme Workshop 2009 – January 2009 FILD FILD realized with a Faraday cup collector: Charged particles penetrate through a stack of conducting foils, separated by insulating foils. Depending on their energy, they pass a number of foils before being stopped, thus causing a current signal.

RFX-mod Programme Workshop 2009 – January 2009 Lithium neutral beam diagnostic A 35 keV Li beam with current of 1 mA will penetrate the plasma up to n e ~2·10 19 m -3. n e profile obtained from intensity of selected spectral Li lines measured by a CCD camera and an array of 16 avalanche detectors 1. n e profile with high spatial resolution and bandwidth of 100 Hz 2. n e fluctuation at 16 radial positions up to 500 kHz.

RFX-mod Programme Workshop 2009 – January 2009 Collection optics (left) and poloidal section (right) for TEXTOR Lithium beam diagnostic Lithium neutral beam diagnostic

RFX-mod Programme Workshop 2009 – January 2009 Completion / further development 2008 activities Upgrade of the Diagnostic Neutral Beam Injector CXRS affected by high background due to natural charge exchange processes, particularly in outer plasma region. Maximization of optical throughput in 2008 did not increase signal enough to disentangle active CX component from dominating passive one. =>To increase the active CX emission, an upgrade of the beam performance is called for. Best solution is to decrease beam divergence with new extraction and acceleration grids. This will increase the beam current density, and favor both MSE and CXRS measurements.

RFX-mod Programme Workshop 2009 – January 2009 Diagnostic Neutral Beam: T i measurements Increased optical etendue insufficient: CX signal still dominated by passive component. Simulations (Von Hellermann code) suggested looking at O VIII rather than C VI. Yet monitoring O VIII 6068 Å with highly luminous high resolution spectrometer yielded no active CX signal. Passive O VIII core plasma emission provided T i evaluation, although uncertainties on transport coefficients and measurement geometry do not permit to exactly define radial measuring position: at high density T i ~T e, at intermediate n e T i ~ 50% T e,, while at low n e O emission too low for Doppler broadening evaluations. MST experience suggests using UV emission lines (larger effective CX cross sections) -> Calculation of such lines added in simulations and new diagnostic layout being designed, to compensate for optical fibers losses.

RFX-mod Programme Workshop 2009 – January 2009 Diagnostic Neutral Beam: B t measurements Hα measurements provided a weak beam emission signal that will be used for a first attempt to estimate B t in the center. However the weakness of the signal confirms need to restore injector current at least to original value( 2.5 equivalent A) and that smaller beam divergence should be sought for, possibly by changing the extraction grids.

RFX-mod Programme Workshop 2009 – January 2009 Completion/further development 2008 activities Microwave reflectometer After successfull commissioning of first band, installation of the other 4 bands planned for Soft X-Ray (SXR) diagnostics New horizontal SXR camera Various mechanical parts have been built and will be completed in Most electronics purchased and tested. The diagnostic will be installed on RFX in the first part of SXR Multifilter Supplies the core Te by two-foil technique. Planned to upgrade from 4 to 6 channels with an improved chord layout. Tomography vacuum and control system The new vacuum system and control computer will be installed in the first shutdown of 2009.

RFX-mod Programme Workshop 2009 – January 2009 Completion/further development 2008 activities Edge measurements Temperature and density profile from thermal He beam A first set-up, consisting of a spectrometer coupled to a CCD camera, gave T e and n e in with a time response of 80 ms at 3 radial positions. The spectrometer will be modified to accomodate 3 slits coupled to photomultipliers for a time response up to 2 MHz, suitable for T e and n e fluctuations measurements Fast insertable pneumatic system for edge probes Following the feasibility study performed during year 2008, the system will be developed in Arcless power supply for ion saturation measurement Following the design activity performed in year 2008, the construction and test of the new power supply will be carried out.

RFX-mod Programme Workshop 2009 – January 2009 Microwave Reflectometer Ka band (26  40 GHz, n e : 0.9  2·10 19 m 3 ), installed. First measurements show strong reflection when the n e > critical value : (f pe 2 = e 2 n e /(4     m e ) > f mw 2 ) Signal post-processing to extract physical information in preparation. Other 4 bands in 2009 to get fast time evolution of a 5- point density profile

RFX-mod Programme Workshop 2009 – January 2009 Upgrade of triple Langmuir probe In addition to temperature, plasma density and potential measurements added. Measurement circuit rebuilt => range of temperature measurement doubled. System for protecting circuits from plasma arcs tested and installed. New acquisition system based on optical fibers: sampling frequency increased to 5 MHz. Effect of magnetizing winding currents (up to 50 kA) on optical transmitters reduced by positioning close to vacuum vessel.

RFX-mod Programme Workshop 2009 – January 2009 impurity pellet injector Injector characteristics Pellet speed: 50÷200 m/s Pellet size: Ø0.5÷2 mm x 1÷3 mm Magazine: 30 pellets Material: Li, C, B Aims Measurement of the pitch of the magnetic field lines Transport studies First wall conditioning

RFX-mod Programme Workshop 2009 – January 2009 Impurity pellet injector Interface to RFX-mod designed and ordered. Important preparation activities completed:  Lithium handling and pellet preparation tools have developed  Tests done to determine vacuum pumping requirements to limit driver gas injection into RFX-mod.  Sabot loading parts re-design improved launch system reliability and reduced running manpower requirements. Injector to be installed in early 2009.

RFX-mod Programme Workshop 2009 – January 2009 New horizontal SXR camera Most of the electronics (acquisition) purchased; 2 prototype amplifiers tested, defining the final version of the amplification stage. The various parts of the diagnostic have been built but the final on RFX-mod will occur in 2009

RFX-mod Programme Workshop 2009 – January 2009 Completion/further development 2008 activities Impurity pellet injector Due to delay in designing injector/machine interface, injector will be mounted in beginning of It will be used with Lithium for wall conditioning and for magnetic pitch angle measurements using the new fast CMOS camera. Impurity transport studies will be also performed.

RFX-mod Programme Workshop 2009 – January 2009 RFX-mod diagnostics present & future Physical quantity nene CO 2 interferometer 84 point/10 pulse Thomson scattering 12 point edge T. scattering Microwave reflectometer TeTe 84 point/ 10 pulse Thomson scattering Spectroscopy (line intensity ratio) SXR two-filter monitor (4 chords) 12 point edge Thomson scattering SXR two-filter tomography TiTi Multichannel spectrometer Diagnostic Neutral Beam CXRS Magnetic deflection NPA Impurities & flows Multichannel visible–UV spectrometer Flat-field survey spectrometer Vacuum CTV spectrometer Interference filter array Grazing incidence spectrometer SXR–bolometric tomography Multilayer filters SXR spectrometer laser Blow-Off Solid pellet injector Diagnostic Neutral Beam CXRS Internal BMagnetic probes FIR polarimeter Q profile from H pellets + CMOS fast camera Fast insertable probbes Solid pellet injector+ CMOS fast camera

RFX-mod Programme Workshop 2009 – January 2009 RFX-mod diagnostics present & future Physical quantity Fluctuations & Turbulence SXR tomography Electrical probe arrays CO 2 interferometer GPI Microwave reflectometer FIR polarimeter Edge plasmaTriple Langmuir probe U-probe ISIS Gundestrup probe GPI edge T e & n e from He line intensity ratio Plasma-Wall Int. / influxes Surface collector and erosion probes Interference filter array CCD cameras with interference filters H  monitors CMOS fast camera

RFX-mod Programme Workshop 2009 – January 2009 Conclusions Some interesting new diagnostics became fully operational in 2008 Others made progress and should be available before summer 2009 This makes the diagnostic data set reacher and should entice more challenging experimental proposal for the RFX-mod experimental program Developement work continues and “new entries” are expected also for next year