On aging problem of glass Resistive Plate Chambers India-based Neutrino Observatory (INO) collaboration JIGSAW.

Slides:



Advertisements
Similar presentations
Cosmic Ray Test of INO RPC Stack M. Bhuyan 1, V.M. Datar 2, S.D. Kalmani 1, S.M. Lahamge 1, N.K. Mondal 1, P. Nagaraj 1, S. Pal 1, L.V. Reddy, A. Redij.
Advertisements

Glass Resistive plate chambers for muon Detection
COSMIC RAY MUON DETECTION USING SCINTILLATION COUNTER AND WAVELENGTH SHIFTING FIBERS ARUNODAYA BHATTACHARYA VSRP-2009,TIFR,MUMBAI 6/7/09.
National Symposium on Science & Technology of Glass/Glass-Ceramics (NSGC-06), Bhabha Atomic Research Centre, Mumbai, INDIA, September 15-16, 2006 Introduction.
Development of high rate RPCs Lei Xia Argonne National Laboratory.
Prototyping and study of Glass Spark Chamber detectors B.Satyanarayana TIFR, Mumbai.
Aging, High Rate and Shielding L. Lopes Lip-Coimbra.
1 Sep. 19, 2006Changguo Lu, Princeton University Induced signal in RPC, Configuration of the double gap RPC and Grouping of the strips Changguo Lu Princeton.
Resistive Plate Chambers for CMS (Pre-assembly Jobs done at BARC) Archana Sharma, Suman B.Beri P.U, Chandigarh & L.M.Pant BARC, Mumbai.
Gas Avalanche (%) Streamer (%) Maximum (%) Volume (L) Density (g/L) Weight (Kg) R134a , Isobutane , SF.
M. Bhuyan 1, V.M. Datar 2, S.D. Kalmani 1, S.M. Lahamge 1, S. Mohammed 3, N.K. Mondal 1, P. Nagaraj 1, A. Redij 1, D. Samuel 1, M.N. Saraf 1, B. Satyanarayana.
1 Dayabay RPC Detector Zhang Jiawen Outline  Motivation  RPC introduce  RPC for Daya Bay  Efficiency and noise  Module structure  Module.
ARNAB BANERJEE Variable Energy Cyclotron Centre, India.
HCAL with Resistive Plate Chambers José Repond Argonne National Laboratory Presented at the Chicago Linear Collider Workshop January 7-9, 2002.
INDIA-BASED NEUTRINO OBSERVATORY (INO) STATUS REPORT Naba K Mondal Tata Institute of Fundamental Research Mumbai, India NUFACT Scoping Study Meeting at.
ATLAS RPC: Cosmic Ray Teststand at INFN Lecce G. Chiodini, M. Bianco, E. Brambilla, G. Cataldi, R. Coluccia, P. Creti, G. Fiore, R. Gerardi, E. Gorini,
1 Daya Bay Collaboration Meeting, IHEP, Beijing, 8/1-3/2007 RPC aging concern Changguo Lu Princeton University Daya Bay Collaboration Meeting IHEP, Beijing,
STATUS OF INDIA-BASED NEUTRINO OBSERVATORY (INO) Naba K Mondal Tata Institute of Fundamental Research Tata Institute of Fundamental Research Mumbai, India.
RPC (Resistive Plate Chamber)
Characterization And Testing Of 2m X 2m Glass Resistive Plate Chamber Mohammed Salim M Aligarh Muslim University.
Results from development of Glass RPCs for INO detector
Development and study of Glass Resistive Plate Chambers Satyanarayana Bheesette Roll number: Supervisors Prof Raghava Varma, IIT Bombay Prof Naba.
Naba K Mondal, TIFR, Mumbai ICAL ( conceptual) INO Peak at Bodi West Hills Prototype ICAL at VECC 2mX2m RPC Test Stand at TIFR ASIC for RPC designed at.
Status of INO detector R&D B.Satyanarayana TIFR, Mumbai.
November 5, 2004V.Ammosov ITEP-Moscow, Russian CBM meeting 1 IHEP possible participation in CBM TOF system Vladimir Ammosov Institute for High Energy Physics.
PHENIX RPC in China Li Ye Shouyang Hu Xiaomei LI China Institute of Atomic Energy
RPC STATUS AT PANJAB UNIVERSITY Panjab University, Chandigarh India-CMS Meeting, 28 th July, 2011.
Glass Resistive Plate Chambers
LRT2004 Sudbury, December 2004Igor G. Irastorza, CEA Saclay NOSTOS: a spherical TPC to detect low energy neutrinos Igor G. Irastorza CEA/Saclay NOSTOS.
2 Atmospheric Neutrinos Atmospheric neutrino detector at Kolar Gold Field –1965.
India-based Neutrino Collaboration(INO), INDIA1 B.S.Acharya, Sudeshna Banerjee, P.N.Bhat, S.R.Dugad, P.Ghosh, K.S.Gothe, S.K.Gupta, S.D.Kalmani, N. Krishnan,
1 Results on glass timing RPC aging P. Fonte LIP/ISEC Coimbra, Portugal. 15 October 2002 GSI Darmstadt/Germany.
1 Aging Study for SiD Hcal and Muon System RPCs (University Linear Collider Detector R&D, project 6.19) Changgo Lu, W. Sands, K. T. McDonald, A.J.S. Smith.
Prototypes of high rate MRPC for CBM TOF Jingbo Wang Department of Engineering Physics, Tsinghua University, Beijing, China RPC-2010-Darmstadt, Germany.
RPCs of BESIII Muon Identifier  BESIII and muon identifier  R&D  Mass production  Installation Zhang Qingmin Advisor: Zhang Jiawen.
Status summary of RPC R&D for INO ICAL detector B.Satyanarayana, TIFR, Mumbai Satyajit Jena, IIT Bombay, Powai For INO Collaboration.
Gap Production for Upscope of the Endcap RPCs Sung Keun Park Korea Detector Laboratory Korea University February 5, 2010 Workshop on the Forward CMS RPC.
Andrea Di Simone Andrea Di Simone – INFN Roma2 Andrea Di Simone CERN PH/ATC and INFN-CNAF On behalf of ATLAS RPC groups: Lecce, Napoli, Protvino, Roma2.
Proposer: B.Satyanarayana Mentor: Prof Naba K Mondal
Neutrinos are tiny, neutral, elementary particles which interact with matter via the “weak force”. The Sun produces over two hundred trillion trillion.
July 8, 2003V.Ammosov GSI, CBM meeting1 RPC TOF system for HARP experiment (Applicability for CBM) Vladimir Ammosov Institute for High Energy Physics Protvino.
CBM Collaboration Meeting, GSI Experimental features of strip-RPCs Motivation FOPIs Multistrip-Multigap-RPCs Results Conclusions.
Ion signals with R134a and R134 in a parallel plate proportional counter Edwin Norbeck, J. E. Olson, Y. Onel University of Iowa For Sec. DH-3 of DNP06.
Peter Shanahan – Fermilab Neutrino Scattering Experiment meeting March 14, RPCs in a NuMI Environment Introduction to RPCs Principles of operation.
Test results of Multi-gap RPC Test Chambers for a Digital HCAL  Geometrical design  Test setup  Signal: avalanche mode and streamer mode  Comparison.
Ion signals with R134a and R134 in a parallel plate proportional counter Y. Onel, E. Norbeck, J. E. Olson University of Iowa For HCAL meeting at Fermilab.
Water vapour contamination in the gas mixtures plays the main role in the GRPC ageing [5], and must be kept at the level of hundred ppm or below. To control.
Marcello Abbrescia RPCs for CMS during Phase II RPC rate capability M. Abbrescia, The dynamic behaviour of Resistive Plate Chambers, NIM A 533 (2004) 7–10.
The Proposed India-based Neutrino Observatory (INO) Naba K Mondal Tata Institute of Fundamental Research Indian meet on linear collider Indore, April,
Test on installed RPCs with the gas mixture. Preliminary results. Alessandro Paoloni on behalf of the OPERA RPC Group (Bologna, LNF, LNGS, Napoli, Padova,
Study of glass properties as electrod for RPC
Study of gas mixture containing SF6 for the OPERA RPCs A.Paoloni, A. Mengucci (LNF)
1 Analysis of Small RPC DHCAL Prototype Data (noise and cosmic ray) LCWA09, Albuquerque, New Mexico Friday, October 02, 2009 Qingmin Zhang HEP Division,
On-line gas mixing and multi-channel distribution system S.D.Kalmani, N.K.Mondal, B.Satyanarayana, P.Verma Tata Institute of Fundamental Research, Mumbai,
Final results from an extensive aging test on bakelite Resistive Plate Chambers Stefano de Capua University of Rome II “Tor Vergata” and INFN.
RPCs with Ar-CO2 mix G. Aielli; R.Cardarelli; A. Zerbini For the ATLAS ROMA2 group.
Long-term environmental effects on the ARGO-YBJ RPC array studied with the Detector Control System P. CAMARRI 1, R. CARDARELLI 1, L. PALUMMO 1, C. VIGORITO.
The 6th ACFA Workshop on Physics and Detector at Linear Collider, TIFR, Mumbai, December 15-17, Development of RPCs for INO B.Satyanarayana TIFR,
XI Workshop on Resistive Plate Chambers and Related Detectors, INFN, 5-10 February, Aging test of high rate MRPC Wang Yi Department of Engineering.
Satyanarayana Bheesette Tata Institute of Fundamental Research, Mumbai, INDIA (For INO Collaboration) INO: India-based Neutrino Observatory ICAL: (Magnetised)
R & D Status report on INO Naba K Mondal Tata Institute of Fundamental Research Tata Institute of Fundamental Research Mumbai, India.
SIMULATION STUDIES ON THE EFFECT OF SF 6 IN THE RPC GAS MIXTURE Mohammed Salim, Aligarh Muslim University, INDIA Presented by Satyanarayana Bheesette,
Operation, performance and upgrade of the CMS Resistive Plate Chamber system at LHC Marcello Abbrescia Physics Department - University of Bari & INFN,
Study on Surface Asperities
Sensitivity of Hybrid Resistive Plate Chambers to Low-Energy Neutrons
Preliminary results on optimization of gas flow rate for RPCs
India-based Neutrino Observatory (INO)
A LARGE ATMOSPHERIC NEUTRINO DETECTOR USING RESISTIVE PLATE CHAMBERS
B.Satyanarayana, TIFR, Mumbai For INO Collaboration
Development of Resistive Plate Chamber for charge particle detection
Presentation transcript:

On aging problem of glass Resistive Plate Chambers India-based Neutrino Observatory (INO) collaboration JIGSAW Joint Indo-German School And Workshop 2007 on Neutrinos in Physics, Astrophysics and Cosmology February 2007, Mumbai, India Introduction India-based Neutrino Observatory (INO) collaboration is proposing a large magnetized iron tracking calorimeter of total weight 50 kton using atmospheric neutrinos as source[1]. The proposed detector will have a modular structure of lateral size 48 m X 16 m and will consist of a stack of 140 layers of 6cm thick iron plates interleaved with 2.5 cm gaps to house RPC detector layers. A total of RPCs of dimension 2m X 2m will be needed for his experiment. Shown in Fig. 1 is the INO detector concept. RPC R&D effort Several single gap (2 mm) glass RPCs of area 30 cm X 30 cm as well as a few of larger size 120 cm X 90 cm were built and tested. The V-I characteristics of these detectors were studied. The noise rate was found to be a reliable way of monitoring the stability of the RPC. Streamer plateau efficiencies of over 90% for various gas mixtures have been obtained for minimum ionizing particles as seen from Fig. 2. For all these studies, while Argon fraction in the gas mixture was kept at 30%, R134a and Iso-butane were added to the rest of 70%. Further studies on aging We have tried operating the RPCs in lower gain avalanche mode by the changing the gas to two-component mixture of Freon (R134a) and Iso-butane in the ratio of 95.5:4.5. This didn’t result in drastic improvement with regard to the aging of the chamber. Shown in Fig. 11 is a efficiency monitor for about last 10 days of a RPC before getting damaged. Fig. 1 INO detector concept Fig. 2 Plateau characteristics for different gas mixtures References 1.INO Collaboration, Interim Project Report, Volume 1, INO/2005/01 2.H.Sakai et al, Study of the effect of water vapour on resistive plate chamber with glass electrodes, NIM A, 484, , Carlo Gustavino, Use of Glass RPC for underground experiments: status and perspectives, ASET Colloquium, TIFR, T.Kubo et al, AFM pictures of the surfaces of glass RPC electrodes damaged by water vapour contamination, OCU- HEP, Measurements of the charge linearity and time response of the RPC as a function of applied HV have been made. The typical time resolution, , of the RPC when operated in the HV plateau is about 1.2 nsec(Fig 3). The cross talk between the adjacent pickup strips is found to be less than 6%. Fig. 3 Time resolution in streamer mode Infrastructure development A gas system capable of mixing and distributing four gases was developed (Figs. 4 and 5). The gas is usually mixed in a buffer cylinder and flown from there into the RPC under test. Alumina based moister filter and dust filters are mounted on the gas system’s output line. RPC test system consisting of a scintillator paddle based Cosmic ray telescope as well as a NIM/CAMAC based DAQ system was also developed(Fig. 6). Various RPC assembly and QC jigs were also developed. Fig. 4 4-component gas mixing systemFig. 5 Schematic of gas mixing systemFig. 6 Cosmic ray telescope and DAQ system Aging problem The first encounter we had with the aging problem was when we operated the RPC, results of which are shown in Figs 2 and 3, continuously for a few months. We had noticed that its efficiency dropped suddenly, while the noise rate and chamber current have shot up. The chamber couldn’t be revived. The problem was identical to that reported in the literature[2,3]. The chamber was broke open and the inner surfaces of the electrodes were scanned under Atomic Force Microscope (AFM) [4] and Scanning Electron Microscope (SEM). Shown in Fig. 7 are pictures of two (anode and cathode) damaged electrode and raw glass surfaces. Fig. 7 AFM scans of damaged electrodes and raw glass The SEM images of the same damaged electrode and a raw glass are shown in Fig 8. Fig. 8 SEM scans of damaged electrode and raw glass Element analysis was also performed again both on damaged electrode and raw glass sample, results of which are shown in Fig 9 and the inset tables. The structures shown in the AFM and SEM scans were found to be rich in Fluorine confirming the reasoning that Freon (R134a) gas contaminated with moister forms Hydro Fluoride (HF), which actually damages the RPC. Fig. 9 Element analysis results of damaged electrode and raw glass ElementAtomic% Oxygen28.45 Fluorine40.31 Sodium11.82 Magnesium2.00 Silicon17.41 ElementAtomic% Oxygen64.19 Fluorine4.17 Sodium6.29 Magnesium2.11 Silicon23.25 Following the recipe suggested by H.Sakai et al [2], i.e purging the damaged chamber by pure Argon bubbled through 25% Ammonia solution for 24 hours without electric field, we could recover the efficiency and brought down noise rate. In Fig. 10, we show the recovery characteristics of this chamber. However, the chamber didn’t sustain the recovery for long time later. Conclusions We have successfully developed and built many small and large area glass RPC prototypes. We have obtained results which are consistent with those reported in the literature. We are however, currently facing a serious problem with regard to their sudden aging after continuous operation. The problem was observed both with the streamer and avalanche mode of operation. We have made some preliminary measurements for the moister levels in the gas mixture that we use and found that the moister levels weren’t high. We have also installed moister filters on the gas lines, but found that that it didn’t solve the problem. We are currently working on better monitoring of moister levels using in-situ sensors, monitoring of various ambient parameters such as temperature, relative humidity and barometric pressure as well as trying with different glasses for electrodes etc. Recovery of a damaged RPC Fig. 14 Recovery characteristics of a damaged RPC Fig. 10 AFM scans of damaged electrode and after wiping it clean The structures on the damaged electrodes were found to loose deposits on the electrodes rather than permanent damaged regions on the glass. This was demonstrated by the AFM images shown in Fig. 10. On the left plate, we have shown the damaged surface, while on the right, we show the same sample which was wiped clean by a dry rough tissue paper. Fig. 11 Efficiency history of a RPC getting damaged Shown in Fig. 12 are the noise rate history of the RPC and its individual strip rates. We see from the plot on the right, that the increase in the noise rate is not a local phenomenon. Fig. 13 Noise rate and individual strip rate history Fig. 12 Streamer size history of the RPC A parameter called streamer size has been devised and was monitored during long term tests of the RPC. The streamer size indicates the fraction of single strip hits for a cosmic ray muon trigger to its sum with the adjacent strips. We find that the streamer size parameter increases monotonically with time, indicating that the size of region which is getting damaged is also increasing. This is ultimately leading to a run a way condition.