Chapter 16 Assessment of Hemodynamic Pressures

Slides:



Advertisements
Similar presentations
Sharon /Penny. 1.Review indications for the use of PA catheter with heart failure patients. 2.The difference of the four major types of PA catheters.
Advertisements

Hemodynamic Monitoring
SWAN GANZ CATHETERS The flow-directed balloon-tipped pulmonary artery catheter (PAC) right heart catheter.
Chapter 15a Blood Flow and the Control of Blood Pressure.
Advanced Nursing Concepts Part 1: Hemodynamic Monitoring
Introduction To The Cardiovascular System Chapter 12: Anatomy and Histology.
Arterial Catheters Systemic arterial blood pressure is most accurately measured by placing a catheter directly into a peripheral artery. Peripheral arterial.
CVP AND PCWP MONITORING Dr RANDEEP SINGH DHALIWAL MODERATED BY Dr HARSH MADHOK
Cardioanaesthesia. Coronary artery disease O 2 delivery Coronary blood flow = directly related to coronary perfusion pressure (CPP) CPP = aortic diastolic.
Pulmonary Artery Catheter
5/24/ HEMODYNAMIC MONITORING. OBJECTIVE 5/24/ Describe the three attributes of circulating blood and their relationships. 2. Identify types.
HEMODYNAMIC MONITORING NUR 351/352 PROFESSOR DIANE E. WHITE RN MS CCRN PhD (c)
Pulmonary artery Balloon (swan Ganz)
CENTRAL VENOUS PRESSURE LEARNING OUTCOMES By the end of this session the student should be able to : Explain the indications for a patient requiring.
MAP = CO * TPR CO = SV * HR SV = EDV - ESV
Cardiogenic Shock and Hemodynamics. Outline Overview of shock – Hemodynamic Parameters – PA catheter, complications – Differentiating Types of Shock Cardiogenic.
Chapter 15 Assessment of Cardiac Output
The Recording of Jugular Venous & Carotid Arterial Pulses.
Pressure, Flow, and Resistance Understanding the relationship among pressure, flow and resistance can help you understand how cardiac output and vascular.
Hemodynamic Monitoring and Transthoracic Lines
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
MODULE F – HEMODYNAMIC MONITORING. Topics to be Covered Cardiac Output Determinants of Stroke Volume Hemodynamic Measurements Pulmonary Artery Catheterization.
Chapter: 38 Pulmonary Circulation, Pulmonary Edema, Pleural Fluid
CENTRAL LINES AND ARTERIAL LINES
Hemodynamics Is defined as the study of the forces involved in blood circulation. Hemodynamic monitoring is used to assess cardiovascular function in the.
Cardiovascular System Assessments
Hemodynamic Monitoring By Nancy Jenkins RN,MSN. What is Hemodynamic Monitoring? It is measuring the pressures in the heart.
CONCEPTS OF NORMAL HEMODYNAMICS AND SHOCK
Indication and contra-indications for cardiac catheterization
Chapter 67 Nursing Management: Shock, Systemic Inflammatory Response Syndrome, and Multiple Organ Dysfunction Syndrome.
1 © 2013 Cengage Learning. All Rights Reserved. May not be copied, scanned, or duplicated, in whole or in part, except for use as permitted in a license.
Focus on Hemodynamic Monitoring and Circulatory Assist Devices
1 Arterial Lines Set Up & Monitoring Union Hospital Emergency Department.
Hemodynamic Monitoring
Chapter 19: Functions of the Blood Vessels Chapter 19: Functions of the Blood Vessels.
Echocardiography in ICU Michel Slama AmiensFrance LEVEL 1 basic LEVEL 2: advanced.
Cardiogenic Shock Dr. Belal Hijji, RN, PhD October 12 & 15, 2011.
CHAPTER 6 DR. CARLOS ORTIZ BIO-208
EDU2HBS Human Body Systems 1 Cardiovascular System.
Definition and Classification of Shock
Copyright © 2008 Lippincott Williams & Wilkins. 1 Assessment of Cardiovascular Function Hemodynamic Monitoring.
Copyright © 2008 Thomson Delmar Learning CHAPTER 15 Hemodynamic Measurements.
Chapter 9 Heart. Review of Structure and Function The heart is divided into the systemic (left) and pulmonary (right) systems –The pulmonary system has.
HEMODYNAMIC MONITORING: The Fundamentals
Intra-Aortic Balloon Pump What it is and what it does
Heart  Pericardium  Cardiac muscle  Chambers  Valves  Cardiac vessels  Conduction system.
Venous Pressure 1.
CVS Monitoring in Shock
RESPIRATORY 221 WEEK 3 PULMONARY BLOOD FLOW. Vascular System  Two Systems : Each have its own reservoir, pump and set of vessels  Pulmonary Circulation.
SHOCK. SHOCK Shock is a critical condition that results from inadequate tissue delivery of O2 and nutrients to meet tissue metabolic demand. Shock does.
Chapter 19: Functions of the Blood Vessels Chapter 19: Functions of the Blood Vessels.
Elsevier items and derived items © 2008, 2004 by Mosby, Inc., an affiliate of Elsevier Inc. Chapter 12 The Circulatory System Dr. Allan Ayella.
Hemodynamic Monitoring John Nation RN, MSN Thanks to Nancy Jenkins.
Assessment of the Cardiovascular System p
Arterial Blood Pressure(ABP) Arterial Blood Pressure(ABP) Central Venous Pressure(CVP) Central Venous Pressure(CVP) Pulmonary Artery Pressure(PAP) Pulmonary.
Cardiac Cycle- 1 Mechanical events, Volume & Pressure changes in cardiac chambers & the great vessels during the cardiac cycle.
HEMODYNAMIC MONITORING
HEMODYNAMIC MONITORING
Pulmonary Artery Pressure Monitoring
Physiology of Circulation
SHOCK.
Objectives Describe the cardiovascular monitoring techniques used in the care of critically ill patients and how to interpret the results of hemodynamic.
9/11/2018 Basic principles of advanced hemodynamic monitoring in anesthesia and ICU Marta Zawadzka 1 1.
Cardiac Cath NUR 422.
Cardiac Output O2 Saturation Capillary Refill
Physical principles of hemodynamic and bioreology
Nursing Care of Patients in Shock
Definition and Classification of Shock
Chapter 46 – Circulatory & Respiratory Systems
INVASIVE PRESSURE MONITORING
Presentation transcript:

Chapter 16 Assessment of Hemodynamic Pressures

Learning Objectives After reading this chapter you will be able to: Describe the following regarding arterial cannulation: Indications for placing an A line Catheter; common insertion sites Procedure for placement of the catheter Interpretation of arterial pressure waveforms Pressures measured and their interpretation Potential complications

Learning Objectives Describe the following regarding central venous pressure (CVP) monitoring: Indications for placing a CVP catheter Catheter; insertion sites Procedure for placement of the catheter Interpretation of the CVP waveform Interpretation of pressures measured Relationship of CVP to left and right ventricular function Potential complications

Learning Objectives Describe the following regarding pulmonary artery (PA) pressure monitoring: Indications for placing a PA catheter Catheter; insertion sites Procedure for placement of the catheter Interpretation of PA waveforms Interpretation of pressures measured

Learning Objectives (cont’d) Relationship between PA diastolic pressure and pulmonary capillary wedge pressure (PCWP) How to obtain an accurate PCWP reading Relationship between transmural pressure and PCWP Effect of positive end-expiratory pressure on PCWP measurements Complications of using the PA catheter

Introduction Hemodynamic monitoring is performed to: Evaluate intravascular fluid volume Evaluate cardiac function Evaluate vascular function Identify sudden changes in the patient’s hemodynamic status Invasive monitoring is needed to obtain an accurate evaluation of hemodynamics

Arterial Pressure Monitoring Indications In patients with severe hypotension or hypertension In patients who may need frequent arterial blood gas assessment Patients in shock or respiratory failure are candidates for placement of an arterial line

Placement of the Arterial Line Most often placed in the radial artery This site is readily accessible and has collateral circulation This site is easy to monitor for bleeding or other complications The femoral artery is less affected by vasoconstriction but more difficult to monitor for bleeding

Arterial Pressure Waveforms The arterial pressure wave should have a clear upstroke on the left A dicrotic notch on the downstroke on the right The dicrotic notch represents aortic valve closure

Arterial Pressure Waveforms (cont’d)

Arterial Pressure Waveforms (cont’d)

Interpretation of Arterial Pressures Normal = 120/80 mm Hg Hypertension = >160/90 mm Hg Hypotension = <90/60 mm Hg Arterial pressure is only a general sign of circulatory status Hypotension is often a late sign of low cardiac output

Interpretation of Arterial Pressures (cont’d) Hypotension is caused by: Low blood volume Poor cardiac function Low vascular resistance A low diastolic pressure can compromise coronary artery perfusion

Interpretation of Arterial Pressures (cont’d) Hypertension is caused by: Excessive contraction of the left ventricle Vasoconstriction Administration of vasopressors Sympathetic stimulation (as occurs with fear and stress)

Interpretation of Arterial Pressures (cont’d) Pulse pressure: difference between systolic and diastolic pressures Normal is 30 to 40 mm Hg A low pulse pressure is common when stroke volume is low Mean arterial pressure (MAP) is normally 80 to 100 mm Hg MAP <60 mm Hg compromises function of vital organs

Complications of Continuous Arterial Pressure Monitoring Ischemia Occurs with embolism, thrombus, or arterial spasm Can result in tissue necrosis if not recognized rapidly Hemorrhage Occurs if line becomes disconnected Infection

Monitoring CVP Indications To assess circulating blood volume and filling pressures of the heart To assess right ventricular function Patients who have had major surgery or trauma need a CVP catheter Patients with pulmonary edema often benefit from CVP monitoring

CVP Catheters and Insertion Sites Most popular catheter is 7 French with a triple lumen The triple lumen allows infusion of medications and a port from which to obtain blood samples The internal jugular is a popular site for insertion of the catheter

CVP Waveforms Reflects the pressures in the right atrium Normal waveforms have three waves: “a”, “c”, and “v” “a” wave occurs with atrial contraction “c” wave occurs with movement of AV valve back toward the atrium during systole “v” occurs with atrial filling during systole

CVP Waveforms (cont’d)

Respiratory Influence on CVP Waveforms Spontaneous inspiratory efforts cause CVP to decrease and are seen on the waveform Positive pressure breaths cause the CVP to increase CVP monitoring during mechanical ventilation requires brief disconnection of the ventilator unless PEEP is being applied

Methods of Measuring CVP Transducer system CVP reported in mm Hg More accurate and provides a waveform Water monometer Reported in cm H2O Inexpensive Easy to use

Interpretation of CVP Causes of increased CVP Fluid overload Right/left heart failure Pulmonary hypertension Tricuspid valve stenosis Pulmonary embolism Increased venous return

Interpretation of CVP (cont’d) Causes of decreased CVP Reduced circulating blood volume Vasodilation (reduced venous return) Leaks in the pressure system Spontaneous inspiration

Complications of CVP Monitoring During placement Bleeding Pneumothorax Over time Infection (main potential problem) Embolus Air embolus

Pulmonary Artery Pressure Monitoring Developed to allow better evaluation of left ventricular function Allows assessment of: Left ventricular filling pressure Pulmonary vascular resistance Arteriovenous oxygen difference Mixed venous oxygen levels

Indications for PA Pressure Monitoring Indications not well defined Research shows many complications and may be of limited benefit Today PA catheter is placed on a case-by-case basis taking into consideration patient’s condition and staff qualifications

Indications for PA Pressure Monitoring (cont’d) Conditions for using the catheter Severe cardiogenic pulmonary edema Patients with ARDS who are hemodynamically unstable In patients who have had major thoracic surgery Patients with septic or severe cardiogenic shock

Catheters and Insertion Sites

Catheters and Insertion Sites (cont’d) The PA catheter has multiple lumens and is balloon tipped The balloon is used to float the catheter in place and to measure left ventricular filling pressures Most common sites for insertion include the subclavian and internal jugular veins

Insertion of the Catheter Catheter is floated through the right side of the heart and into the pulmonary artery Once it wedges into place, balloon is deflated Distinctive waveforms seen as catheter passes through the right atrium, right ventricle, pulmonary artery, and into the wedge position

PA Pressure Waveforms

Interpretation PA systolic pressure (20-30 mm Hg) Increases with high pulmonary vascular resistance Decreases with poor right heart function and pulmonary vasodilation PA diastolic pressure (8-15 mm Hg) Normally reflects left heart filling pressures Does not reflect left heart filling pressures when pulmonary vascular resistance elevated

Interpretation (cont’d) Wedge pressure Normally 4 to 12 mm Hg Must be interpreted in light of the patient’s medical history (history of MI will cause a stiff left ventricle and lead to higher pressures) Elevates with left heart failure or mitral stenosis Decreases with hypovolemia

Obtaining an Accurate Wedge Pressure Requires careful calibration of equipment Measure at end exhalation Catheter tip must be in West zone III where blood flow is continuous Low blood volume and high alveolar pressures can cause wedge pressure readings to be inaccurate

Complications of PA Monitoring During cannulation hemothorax, pneumothorax, and damage to blood vessels are possible Dysrhythmias can occur as catheter passes through the heart and during monitoring Catheter source of infection, thrombus, embolism, bleeding, and hematoma Pulmonary infarction possible

Summary Hemodynamic monitoring common in the ICU to identify cardiovascular problems and to measure the effects of therapies Continuous monitoring of arterial pressure, CVP, and PA pressures available Placement of catheter and its continuous use have potentially serious complications A risk/reward assessment must be done