Lecture 1 PRACTICE TEST Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Slides:



Advertisements
Similar presentations
Ch 18 – Let There Be Light Ch 19 – Spectrophotometry: Instruments and Applications.
Advertisements

Spectrophotometers and Concentration Assays
Spectroscopy Lecture 4 Ahmad Razali Bin Ishak Department of Environmental Health Faculty of Health Sciences UiTM Puncak Alam.
Non-Instrumental Methods
Wavelength, Frequency, and Energy Practice Problems
Atomic Absorption and Atomic Fluorescence Spectrometry Wang-yingte Department of Chemistry
AAS and FES (Ch 9, 7th e, WMDS)
Atomic Absorption Spectroscopy AAS Comparatively easy to use Low maintenance Low consumables Good for measuring one element at a time. Comparatively easy.
Atomic Absorption Spectrometry Dr AKM Shafiqul Islam University Malaysia Perlis.
HL Chemistry - Option A: Modern Analytical Chemistry ATOMIC ABSORPTION SPECTROSCOPY.
1 Molecular Luminescence Spectroscopy Lecture 31.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
What is Spectroscopy? The study of molecular structure and dynamics through the absorption, emission and scattering of light.
Chapter Eleven Ultraviolet-Visible Spectrophotometry
Spectrophotometry Chapter 17, Harris
Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh
Atomic Absorption Spectroscopy (AAS)
Introduction to Spectrophotometry
Lecture 3 INFRARED SPECTROMETRY
Lecture 5. UV-VIS Spectroscopy. Ultraviolet and Visible Absorption Spectroscopy When matter absorbs electromagnetic radiation in the domain ranging from.
Spectroscopy (continued) Last time we discussed what spectroscopy was, and how we could use the interaction of light with atoms and molecules to measure.
Lecture 2b. Electromagnetic Spectrum Visible range: = nm Ultraviolet: = nm Low energyHigh energy.
Non-Instrumental Methods
Introduction to Instrumental Analysis - Spectrophotometry
Common types of spectroscopy
 PART Requirements for Spectroscopic Techniques for Polymers 1. High resolution 2. High sensitivity (>1%) 3. High selectivity between molecular.
Infrared Spectroscopy
1 University of Petra Faculty of Science & Arts Department of Chemistry Seminar I.R Spectroscopy By Firas Al-ouzeh Supervisor : Nuha I. Swidan Summer 2007.
Advanced Spectroscopy 3. Infrared Spectroscopy. Revision 1.What molecular or structural features give rise to absorption of infrared (IR) radiation? covalent.
Chapter 26 Molecular Absorption Spectrometry Molecular spectroscopic methods are among the most widely used of all instrumental analytical methods. Molecular.
SPECTROPHOTOMETRY. Determines concentration of a substance in solution by Measures light absorbed by solution at a specific wavelength by using spectrophotometer.
CHAPTER 15 APPLYING MOLECULAR AND ATOMIC SPECTROSCOPIC METHODS: SHEDDING MORE LIGHT ON THE SUBJECT Introduction to Analytical Chemistry.
Fluorometric determination of riboflavin
UV-Vis Absorption Spectroscopy
Spectrophotometry: An Analytical Tool
Chapter 13 An Introduction to Ultraviolet- Visible Molecular Absorption Spectrometry.
Chapter 12 Infrared Spectroscopy Jo Blackburn Richland College, Dallas, TX Dallas County Community College District  2006,  Prentice Hall Organic Chemistry,
Spectrophotometers and Concentration Assays
Beers Law for a Single Component Sample I0I0 A = Absorbance = - log 10 I I / I 0 b = Optical path length c = Solution Concentration (M/L) ε = Molar Absorptivity.
The iron content of runoff from a banana ranch is a necessary analytical parameter to analyze. A 25.0mL sample of the runoff was acidified with HNO3 and.
Spectrophotometry.
Spectrofuorometer lab. 1. Fluorescence spectroscopy or (spectrofluorometry) Is a type of electromagnetic spectroscopy which analyzes fluorescence from.
Asa Arjoon U6 Chemistry Presentation on Visible and Ultraviolet Spectroscopy Name : Form : Subject :
Introduction to Spectrochemical Methods
Visible Spectroscopy Electromagnetic Radiation: Light & Color.
Spectrophotometer.
ATOMIC ABSORPTION SPECTROSCOPY (AAS) Atomization: It is the conversion of molecules to their component atoms in gaseous state using a source of heat (flame).
Lecture 7 Mass Spectrometry UV/Vis Spectroscopy
UV SPECTROSCOPY Absorption spectra.
Summary: (Last lecture) Absorption spectroscopy definition electromagnetic spectroscopy matter absorption spectroscopy fundamental terms (transmittance,
Photometry.
Fluorometric determination of riboflavin
Chapter 13 & 14 CHM 411 Spring 2013 Suroviec. I. UV-Vis molecular absorption.
Absorption Spectroscopy CHEM 251 Week of November 1 st, 2010 Alexis Patanarut.
Atomic Absorption Spectroscopy.  Qualitative test for metals in solution  Can also be used for coloured lights  This emission of light is called an.
11 Instrumental Analysis Tutorial By the end of this session the student should be able to: 1.Use mathematical formulae to calculate absorbance,
Spectrophotometry at a Glance
An introduction to Spectrometric Methods. Spectroscopy Definition Spectroscopy is a general term for the science that deal with the interactions of various.
Spectrophotometers and Concentration Assays Chapter 7.
Absorption Spectroscopy
11 Instrumental Analysis Tutorial Use mathematical formulae to calculate absorbance, transmittance of a sample and wave parameters. Determine factors.
Non-Instrumental Methods
Estimation of analyte concentration on the basis of light absorption
Spectrophotometer Dr . S. Jayakumar.
Molecular Absorption Spectroscopy
Lecture 2b Beer’s Lambert Law.
Analytical methods Prepared By Dr. Biswajit Saha.
Light and Matter Main Concept:
SPECTROPHOTOMETRY Applied Chemistry.
Beer's- Lambert Law and Standard Curves of concentrations
Presentation transcript:

Lecture 1 PRACTICE TEST Copyright ©The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

The active agent in common household bleach is Sodium hypochlorite The active agent in common household bleach is Sodium hypochlorite. Calculate the pH of 0.15M NaOCl solution (Ka HOCl = 3.0 x 10-8 ) MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE

MULTIPLE CHOICE Which of the following is false? Visible photons carry more energy than infrared photons. Microwave photons carry more energy than infrared photons. Ultraviolet photons carry more energy than visible photons. X-ray photons carry more energy than microwave photons. MULTIPLE CHOICE

MULTIPLE CHOICE A D2 arc lamp is the most widely used source of visible photons. is the most widely used source of ultraviolet photons. is the most widely used infrared source. has a continuous output spanning the ultraviolet and visible ranges. MULTIPLE CHOICE

MULTIPLE CHOICE Double beam spectrometers employ an optical chopper or beam director to alternate the source beam between the reference and sample compartments. usually employ a motor drive to move the dispersive element in the monochromator. automatically correct for changes in source output with wavelength. All of the above. MULTIPLE CHOICE

MULTIPLE CHOICE Which of the following is true? If an analysis is accurate, it must also be precise. A precise analytical measurement will always have a small relative standard deviation. If an analysis is reproducible, it will be accurate. None of the above. MULTIPLE CHOICE

Sketch a calibration curve generated using the method of standard additions. Name one advantage offered by the method of standard addition over a conventional analysis. SHORT ANSWERS

In a ultraviolet-visible spectrometer, why is the sample placed after the monochromator? SHORT ANSWERS

Compute the energy in joules of a photon whose wavelength is 321 nm SHORT ANSWERS

List five of the six numerical criteria for selecting analytical methods. SHORT ANSWERS

How does absorption and emission of radiation by atoms differ from that absorbed and emitted by molecules. Comment on the absorption spectrum of an atomic vapor versus a molecular vapor. SHORT ANSWERS

Compare and contrast continuum and lines sources Compare and contrast continuum and lines sources. Give at least one example of each. MULTIPLE CHOICE

What is a laser? What are the advantages of using lasers as spectroscoptic sources. MULTIPLE CHOICE

How many fundamental modes of vibration are predicted for methane (CH4)? Diagram one vibrational mode that you would expect to not be IR active. MULTIPLE CHOICE

Sketch a diagram of a single beam UV-VIS spectrophotometer Sketch a diagram of a single beam UV-VIS spectrophotometer. Label the parts.

Describe the basic difference between atomic emission and atomic absorption spectroscopy.

Carbon monoxide (CO) can be determined at trace levels using IR absorption spectrophotometry. Using a 100.0-cm pathlength gas cell, a standard containing 10.0 ppm CO gave an absorbance of 0.050 at 2170 cm-1. Calculate the concentration (ppm) of a gas sample. PROBLEM SOLVING

Molar absorptivity data for the cobalt and nickel complexes with 2,3-quinoxalinedithiol are: A 0.425 g sample was dissolved and diluted to 50 mL. A 25.0 mL aliquot was treated to eliminate interferences; after addition of 2,3-quinaxalinedithiol, the volume was adjusted to 50.0 mL. This solution has absorbance of 0.446 at 510 nm and 0.326 at 656nm. Calculate the ppm of Ni and Co in the sample. , nm  (Ni)  (Co) 510 nm 5520 36400 656 nm 17500 1240

Li was determined by atomic emission with the method of standard addition. Prepare a standard addition graph to find the concentration of Li. The standard contained 1.62 g Li/mL. Unknown, mL Standard, mL Final Volume, mL Emission intensity 10.0 0.00 100.0 309 5.00 452 10.00 600 15.00 765 20.00 906 SAMPLE PROBLEM