S Demehri 1, M.K Kalra 2, M.L Steigner 1, F.J Rybicki 1, M.J. Lang, 3, S.G Silverman 1. 1.Department of Radiology, Brigham & Women's Hospital, Harvard.

Slides:



Advertisements
Similar presentations
Dr.Bandar Al Hubaishy Urology Department KAUH
Advertisements

Example: In a heart study the systolic blood pressure was measured for 24 men aged 25 and for 30 men aged 40. Do these data show sufficient evidence to.
Improved Conspicuity of Abdominal Lesions with Single-Source Dual-Energy MDCT Hadassah Hebrew University Medical Center Jerusalem, Israel Ruth Eliahou.
RELIABILITY Reliability refers to the consistency of a test or measurement. Reliability studies Test-retest reliability Equipment and/or procedures Intra-
IMAGE QUALITY.
Dr. Mohamed Bingabr University of Central Oklahoma
Epidemiologic Methods- Fall Course Administration Format –Lectures: Tuesdays 8:15 am, except for Dec. 10 at 1:30 pm –Small Group Sections: Tuesdays.
RAD309 Patient Dose.
NC HPS Meeting 10/18-19/2001 Boone, NC Recent Advances in CT Technology and Issues of CT Dosimetry T. Yoshizumi 1,2, M. Sarder 1, R. Reiman 1,2, E. Paulson.
1 Physics Testing for Performance Based Protocol version 3.0 (Now based on ACRIN 6678) QIBA Group 1C.
PET/CT Working Group Update Jayashree Kalpathy-Cramer Sandy Napel.
IMAGE QUALITY NOISE LINEARITY CROSS-FIELD UNIFORMITY IMAGE ARTIFACTS.
Volumetric Measurement of Tumors David F. Yankelevitz, MD.
Intermediate methods in observational epidemiology 2008 Quality Assurance and Quality Control.
Lotte Verbunt Investigation of leaf positioning accuracy of two types of Siemens MLCs making use of an EPID.
Evaluating Hypotheses
Archiving Experiments Based on Radiological Images Fred Prior, Ph.D. Mallinckrodt Institute of Radiology Washington University School of Medicine.
Lehrstuhl für Informatik 2 Gabriella Kókai: Maschine Learning 1 Evaluating Hypotheses.
Lean Body Mass Assessment: Interpretations of Computed Tomography
Seeram Chapter 11: Image Quality
CT Quality Control for CT Scanners. Quality Control in CT A good idea? Yes Required for accreditation? Sometimes Improves image quality? Sometimes Depends.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) May 6, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
V. Rouillard  Introduction to measurement and statistical analysis ASSESSING EXPERIMENTAL DATA : ERRORS Remember: no measurement is perfect – errors.
M. Reddy, A. Livorine, R. Naini, H. Sucharew, A. Vagal
Epidemiologic Methods. Definitions of Epidemiology The study of the distribution and determinants (causes) of disease –e.g. cardiovascular epidemiology.
Meta Imaging Solutions Patient centered innovations Introduces:
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) December 23, 2009 CT Cross-platform Sizing of Phantom Lesions Quantitative Imaging Biomarker Alliance.
Evaluation of the Performance of the Fast Scanning Platform of an OCT System Malcolm Heard 1, Miguel Herrera 1, Geoffrey Ibbott 1 1 Department of Radiation.
Incidental diagnosis of diseases on un- enhanced helical computed tomography performed for ureteric colic Author: Nazim A Ahmad1, M Hammad Ather*1 and.
Strategies for Reducing Radiation Dose in CT. Source: IMV Medical Information division 2004 CT Census.
ESTIMATION. STATISTICAL INFERENCE It is the procedure where inference about a population is made on the basis of the results obtained from a sample drawn.
PREDICTION OF CHEMICAL COMPOSITION OF URINARY CALCULI IN-VIVO BASED ON COMPUTED TOMOGRAPHY ATTENUATION VALUES Abstract Id: IRIA
CT physics and instrumentation
Low Dose Head Computed Tomography Protocol for Evaluation of Non-traumatic Emergencies in Children Rishi Mhapsekar, MD Marilyn J. Siegel, MD Robert McKinstry.
Computed Tomography Q & A
1 Inter-observer Agreement of The Response To Therapy AssessmentInter-observer Agreement of The Response To Therapy Assessment in Advanced Lung Cancer.
Lab 3b: Distribution of the mean
January 27, Epidemiology 1/685 pediatric admissions Lower incidence than adults Higher crystal formation inhibitors in urine M>F Most common stones.
IAEA International Atomic Energy Agency Optimization of Protection in Computed Tomography (CT)-What can radiographers do? IAEA Regional Training Course.
QIBA CT Volumetrics - Cross-Platform Study (Group 1C) March 18, 2009 Interclinic Comparison of CT Volumetry Quantitative Imaging Biomarker Alliance.
APPLICATION OF INDIVIDUALIZED BAYESIAN UREA KINETIC MODELING TO PEDIATRIC HEMODIALYSIS Olivera Marsenic, Athena Zuppa, Jeffrey S. Barrett, Marc Pfister.
3D sequence MRI in the assessment of meniscofemoral and ligament lesions of the knee MA.Chaabouni,A.Daghfous, A.Ben Othman,L.Rezgui Marhoul Radiology departement.
MEASUREMENTS OF RADIATION DOSES IN MULTISLICES COMPUTED TOMOGRAPHY EXAMINATIONS A. ELMAHDI*, A. SULIEMAN *Presenting author 1 Sudan Atomic Energy Commission,
CT QUALITY MANAGEMENT. SPATIAL RESOLUTION CONTRAST RESOLUTION NOISE IMAGE ARTIFACTS RADIATION DOSE.
Part No...., Module No....Lesson No
Sample Size Determination
Quality Assurance.
The PET/CT Working Group: CT Segmentation Challenge Informatics Issues Multi-site algorithm comparison Task: CT-based lung nodule segmentation.
1 Physics Testing for Performance Based Protocol version 2.1 QIBA Group 1C.
Quality Control Bushong Chapter 10.
CT ANGIOGRAPHY Dr Mohamed El Safwany, MD. Intended learning outcome The student should learn at the end of this lecture CT IMAGE OF THE BLOOD VESSEL OPACIFIED.
Impact of Contrast Media Concentration and kVp settings on Image Quality in CT Angiography of the Intracranial Vessels Birgitta Ramgren MD Roger Siemund.
3. Populations and samples Yun, Hyuk Jin. Populations Objects, or events, or procedures, or observations A population is thus an aggregate of creatures,
Computed Tomography Computed Tomography is the most significant development in radiology in the past 40 years. MRI and Ultrasound are also significant.
Purpose The CT examination is first tool to detect brain ICH or skull bone fracture. But the skull fontanel and suture is developing in infant and child,
Novel method of 3D-assisted quantitative assessment of orbital volume using an open-source software platform 1 Victor Bong-Hang Shyu, M.D., 1 Chih- hao.
Wednesday Case of the Day History: CT pulmonary angiography (image shown) was performed on a 24-year-old female patient with pleuritic chest pain and increased.
Development of elements of 3D planning program for radiotherapy Graphical editor options  automated enclose of contour  correction of intersections 
Automated airway evaluation system for multi-slice computed tomography using airway lumen diameter, airway wall thickness and broncho-arterial ratio B.
CT Multi-Slice CT.
Sample Size Determination
Radiological Sciences Department Ph.D., Paris-Sud 11 University
CT dose optimization software synergy – A clinical perspective
Henderson JM, Moslim MA, Knox MK, Cowan NC
Physics Testing for ACRIN 6678 Protocol version 3.0 QIBA Group 1C
David J. Brenner, Maria A. Georgsson  Gastroenterology 
Role of dual energy spectral computed tomography in characterization of hepatocellular carcinoma: Initial experience from a tertiary liver care institute 
The accuracy of computed tomography central luminal line measurements in quantifying stent graft migration  Andrew England, MSc, Marta García-Fiñana,
The use of 80 kV versus 100 kV in pulmonary CT angiography: An evaluation of the impact on radiation dose and image quality on two CT scanners  A. Rusandu,
Presentation transcript:

S Demehri 1, M.K Kalra 2, M.L Steigner 1, F.J Rybicki 1, M.J. Lang, 3, S.G Silverman 1. 1.Department of Radiology, Brigham & Women's Hospital, Harvard Medical School 2.Department of Radiology, Massachusetts General Hospital, Harvard Medical School 3.Department of Biological Engineering, Massachusetts Institute of Technology 4. Presented RSNA 2009 Novel CT-based Method for Determining Urinary Stone Volume: Phantom and Clinical Studies

Why Stone Volume? Urolithiasis : chronic and largely recurrent disease Urolithiasis : chronic and largely recurrent disease CT used to depict size, number, and CT used to depict size, number, and location of urinary calculi to assess metabolic activity: Stone growth or new stone formation in one year Stone growth or new stone formation in one year Stone size has been typically described using maximal axial diameter, which is a poor indicator of stone volumeStone size has been typically described using maximal axial diameter, which is a poor indicator of stone volume

Attenuation Threshold-based CT Methods Attenuation threshold-based CT methods can quantify Attenuation threshold-based CT methods can quantify volume of calcium in the coronary arteries : Coronary calcium score Such methods could be applied both at diagnosis and follow-up of urinary calculi to determine if medical therapy is necessary, and to monitor the success of medical treatment. Such methods could be applied both at diagnosis and follow-up of urinary calculi to determine if medical therapy is necessary, and to monitor the success of medical treatment. In this project, we described fixed (FTM) and variable (VTM) attenuation-threshold based methods for quantification of volume of urinary stones

Material & Methods: Gold Standard for Stone Volume Thirty six calcium oxalate stones were obtained from a human stone bank (de-identified samples). Thirty six calcium oxalate stones were obtained from a human stone bank (de-identified samples). Gold standard for stone volumes : Gold standard for stone volumes : Fluid- displacement technique With repeated measurements of a flask mass filled with double-distilled water, the standard error of this method was estimated to be 4 mm 3. With repeated measurements of a flask mass filled with double-distilled water, the standard error of this method was estimated to be 4 mm 3.

Material & Methods: Phantom Experiment Stones embedded in ground meat (approximately 30 HU) and placed in dosimetric holes in abdominal slices of Alderson-Rando Phantom. Stones embedded in ground meat (approximately 30 HU) and placed in dosimetric holes in abdominal slices of Alderson-Rando Phantom. Phantom was scanned using a CT protocol (120 kVp, 200 mAs) in our clinical practice for patients with acute flank pain Phantom was scanned using a CT protocol (120 kVp, 200 mAs) in our clinical practice for patients with acute flank pain

Material & Methods: Phantom Experiment All images reconstructed at 0.6, 1, and 3 mm thick sections with no overlap. All images reconstructed at 0.6, 1, and 3 mm thick sections with no overlap. The phantom rescanned using lower tube currents (150, 100, and 50 mAs; other parameters held constant) and tube potentials (80 and 100 kVp maintaining a constant CTDI). The phantom rescanned using lower tube currents (150, 100, and 50 mAs; other parameters held constant) and tube potentials (80 and 100 kVp maintaining a constant CTDI).

Material & Methods: Phantom Experiment Open source software (OsiriX, Mac OS X Version 3.3.2) used to segment the urinary stones. Open source software (OsiriX, Mac OS X Version 3.3.2) used to segment the urinary stones. Using FTM, stones were segmented using two fixed attenuation thresholds: Using FTM, stones were segmented using two fixed attenuation thresholds: HU (the threshold used to determine coronary calcium volume) HU i.e., attenuation value equal to half of the mean attenuation of all stones (1150+/-290, mean+/- SD). Using VTM, stones segmented using individual attenuation-thresholds equal to half of the attenuation of each stone. Using VTM, stones segmented using individual attenuation-thresholds equal to half of the attenuation of each stone.

Material & Methods: Clinical Study-Interobserver Agreement A retrospective study in 17 patients (M/F=1.6, mean age=55) after IRB-approval with urinary calculi. A retrospective study in 17 patients (M/F=1.6, mean age=55) after IRB-approval with urinary calculi. Two independent observers measured the maximum axial diameter of urinary stones stone volumes using both the FTM and the VTM. Two independent observers measured the maximum axial diameter of urinary stones stone volumes using both the FTM and the VTM.

Material & Methods: Statistical Analysis Normalized (%) Bland-Altman analysis used to evaluate the mean difference (i.e., bias) and standard deviation of difference (i.e., precision) between each CT method and the gold standard Normalized (%) Bland-Altman analysis used to evaluate the mean difference (i.e., bias) and standard deviation of difference (i.e., precision) between each CT method and the gold standard To examine the effect of CT parameters (section thickness, mAs, and kVp) on the accuracy and precision of the stone volume measurements: one- way analysis of variance (ANOVA). To examine the effect of CT parameters (section thickness, mAs, and kVp) on the accuracy and precision of the stone volume measurements: one- way analysis of variance (ANOVA). To estimate interobserver agreement: Bland-Altman limits of agreement for the paired measurements for each method. To estimate interobserver agreement: Bland-Altman limits of agreement for the paired measurements for each method.

Normalized Bland-Altman Difference Plot CT– derived Stone Volume Measurement Using FTM, Threshold Level at 130 HU Measurements compared with the volume measurement using fluid displacement technique, the gold standard.

FTM with Threshold Level at 575 HU- Half of the Mean Attenuation of All Stones

VTM- Threshold Level Set at the Half of the Attenuation of Each Stone

a b c Fixed (FTM) and Variable (VTM) threshold methods in phantom study. Using FTM, with segmentation threshold is set at 130 HU (as in coronary calcium score) (a) and at 575 HU (b), respectively. Using VTM (c) with segmentation threshold set at 699 HU (half of the stone attenuation (1398 HU)). The gold standard stone volume was mm mm mm mm 3

a b c The stone volume was measured using variable threshold method (VTM) in 0.6 mm (a), 1 mm (b), and 3 mm (c) section widths. The stone volume using fluid displacement technique as gold standard was 4.1 mm mm mm 3 9 mm 3

Study Limitations Phantom study was limited to calcium oxalate stones Phantom study was limited to calcium oxalate stones Imaging of stone in phantom is an idealized clinical scenario ie., no motion, no radio-opaque surrounding structure (e.g., nephrostomy tube) Imaging of stone in phantom is an idealized clinical scenario ie., no motion, no radio-opaque surrounding structure (e.g., nephrostomy tube) In phantom study, the observer was blinded to gold standard stone volume but not the CT parameters. In phantom study, the observer was blinded to gold standard stone volume but not the CT parameters. The gold standard, has measurement error which could affect the bias and precision of CT based measurements. The gold standard, has measurement error which could affect the bias and precision of CT based measurements.

Novel CT-based Stone Volume Measurement Attenuation threshold-based CT method can accurately and precisely quantify urinary stone volumesAttenuation threshold-based CT method can accurately and precisely quantify urinary stone volumes Individually-derived attenuation-thresholds are superior to fixed thresholdsIndividually-derived attenuation-thresholds are superior to fixed thresholds Thinner collimations yield more accurate volume measurementThinner collimations yield more accurate volume measurement Measurements can be performed using low radiation dose CT protocolsMeasurements can be performed using low radiation dose CT protocols

“The sum of each stone’s volume could be used to derive a cumulative stone volume or “stone score” (akin to coronary calcium score), which may help the radiologist obtain an accurate and precise method of quantifying individual as well as cumulative stone burden and metabolic activity. “

Thank you